Optics of the NIFS negative ion source test stand by infrared calorimetry and numerical modelling

At National Institute for Fusion Science (NIFS), a multi-ampere negative ion source is used to support the R&D on H{sup −} production, extraction, and acceleration. In this contribution, we study the characteristics of the acceleration system of this source, in order to characterize the beam optics at different operational conditions. A dedicated experimental campaign was carried out at NIFS, using as main diagnostic the infra-red imaging of the beam profiles. The experimental measurements are also compared with 3D numerical simulations, in order to validate the codes and to assess their degree of reliability. The simulations show a satisfactory agreement with the experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion beam emittance from an ECRIS

Simulation of ion beam extraction from an Electron Cyclotron Resonance Ion Source (ECRIS) is a fully 3 dimensional problem, even if the extraction geometry has cylindrical symmetry. Because of the strong magnetic flux density, not only the electrons are magnetized but also the Larmor radius of ions is much smaller than the geometrical dimension of the plasma chamber (Ø 64 × 179 mm). If we assume that the influence of collisions is small on the path of particles, we can do particle tracking through the plasma if the initial coordinates of particles are known. We generated starting coordinates of plasma ions by simulation of the plasma electrons, accelerated stochastically by the 14.5 GHz radio frequency power fed to the plasma. With that we were able to investigate the influence of different electron energies on the extracted beam. Using these assumptions, we can reproduce the experimental results obtained 10 years ago, where we monitored the beam profile with the help of viewing targets. Additionally, methods have been developed to investigate arbitrary 2D cuts of the 6D phase space. To this date, we are able to discuss full 4D information. Currently, we extend our analysis tool towards 5D and 6D, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications

Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ~ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The straw tracking detector for the Fermilab Muon g-2 Experiment

The Muon g-2 Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of (110 ± 20) μm, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strong-field QED limitations on TeV-class plasma wakefield accelerators

We demonstrate that quantum and classical radiation effects can become non-negligible for TeV-class beams propagating through plasma channels typical of staged plasma accelerators. Although the quantum nonlinearity parameter χ e remains small under currently envisioned experimental conditions, the cumulative influence of radiation over long acceleration distances can lead to significant modifications to the beam’s energy spread, emittance, and polarization. Our analytic models, validated by particle-in-cell simulations, highlight that for standard Gaussian beams, the orbit-induced energy spread dominates over quantum stochastic effects but can be mitigated by tailoring the beam profile, for example, through ring-shaped transverse distributions. In regimes where the radiation reaction approaches the accelerating force, the emittance may be cooled, forming distinctive ring-shaped phase-space structures. Finally, we analyze the influence of the radiation effect on spin transport inside the wakefield. These findings underscore the importance of considering both classical and quantum radiation dynamics in the design and optimization of future high-intensity plasma accelerators.

accelerator↗

SU-F-T-232: Monthly Quality Assurance in External Beam Radiation Therapy Using a Single System

Purpose: Monthly quality assurance (QA) is time consuming for external beam radiation therapy, taking as long as 6–8 hours for each machine. It is due to the use and setup of multiple devices for different QA procedures. We have developed a single system with rotational capability for the measurement of both optical light and radiation which significantly reduces the time spent on Monthly QA. Methods: A single system using mirrors, a phosphor screen and a CCD camera is housed on a cylindrical motor so that it can rotate 360 degrees. For monthly QA, the system is placed on the patient couch of the medical accelerator with the plane of the phosphor screen at isocenter for all measurements. For optical QA such as optical distance indicator, room laser and light field, the optical image is collected directly with the camera. For radiation QA such as beam profile, MLC speed, picket-fence test, collimator rotation, table rotation and gantry rotation, a brass build-up plate is attached to the top of the phosphor screen. Two brass plates with islands of different thickness were designed for photon energy and electron energy constancy checks. Flex map, distortion map and uniformity map were developed to calibrate the motor bearing, camera/lens distortion, and the phosphor screen’s measured response across the field. Results: Following the TG142 guidelines for monthly QA with our system, the overall run time is reduced from 6–8 hours to 1.5 hours. Our system’s rotating design allows for quick testing of the gantry radiation isocenter test that is also independent of the sag of the gantry and the EPID. Conclusion: Our system significantly shortens the time needed for monthly QA by unifying the tests with a single system. Future work will be focused on extending the technology to Brachytherapy, IMRT and proton therapy QAs. This work is funded in part by a sponsor research grant from JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

07 ISOTOPE AND RADIATION SOURCES↗

High-speed volumetric imaging of formaldehyde in a lifted turbulent jet flame using an acousto-optic deflector

The development of high-speed volumetric laser-induced fluorescence measurements of formaldehyde (CH 2 O-LIF) using a pulse-burst laser operated at a repetition rate of 100 kHz is presented here. A novel laser scanning system employing an acousto-optic deflector (AOD) enables quasi-4D CH 2 O-LIF imaging at a scan frequency of 10 kHz. The diagnostic capability of time-resolved volumetric imaging is demonstrated in a partially premixed DME/air lifted turbulent jet flame near the flame base. Simultaneous imaging of laser beam profiles is performed to account for the laser pulse energy fluctuation and laser sheet inhomogeneity. With the accurate registration of laser sheet positions, the volumetric reconstruction of CH 2 O-LIF signals is performed within a detection volume of 17.3 × 11.9 × 2.3 mm 3 with an average out-of-plane spatial resolution of 250μm. A surface detection algorithm with adaptive thresholding is used to determine the global maximum intensity gradient by calculating gradient percentiles. The flame topology characteristics are investigated by evaluating the 3D curvatures of CH 2 O surfaces. Curvatures calculated using 2D data systematically underestimate the full 3D curvature due to the lack of out-of-plane information. The inner surfaces near the turbulent fuel jet exhibit higher probabilities of large mean curvature than the outer surfaces. The saddle and cylindrical structures are dominant on both the inner and outer surfaces and the elliptic structures occur with lower probability. The results suggest that the damping of turbulent fluctuations by the temperature increase through the CH 2 O region reduces the curvature, but the local structure topology remains self-similar.

42 ENGINEERING↗

Evolution of the beam-width parameter of zeroth-order Bessel–Gaussian beams in collisional plasma with density ripple

In the present paper, we have investigated the self-focusing of zeroth-order Bessel–Gaussian beams in collisional plasma with density ripple. Based on Wentzel–Kramers–Brillouin and the paraxial ray approximations, the nonlinear differential equation governing the evolution of beam-width parameter is evaluated. The variation of beam-width parameter with propagation distance is examined for different values of ripple wave number and beam parameters. From our study, it is seen that stronger self-focusing is obtained when the density ripple is important. The results corresponding to Gaussian beams are deduced from this work as a particular case.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of light polarization in photonic nanojet

Illumination plays a key role in getting high resolution imaging. Photonic nanojet is a new lighting system. Since the transverse beam width of the nanojet can reach λ/3, photonic nanojet is usually considered to be the key point for the explanation of the high-resolution microsphere assisted microscopy. However, the polarization of photonic nanojet are usually out of attention. In this work, we investigate the photonic nanojets formed by illuminating a dielectric microcylinder by two plane waves with different linear polarizations. The influences of wavelength and refractive index contrast between the microcylinder and its surrounding, and the cases illuminated by the Gaussian beam are also studied. Numerical results demonstrate that the TM polarization can generate a wider nanojet waist than the TE polarization, and this is produced by the longitudinal component of the TM-polarization illumination. When the Gaussian beam width becomes larger than diameter of the cylinder, the nanojet waists become smaller than that obtained by the cylinder under a plane wave. At last, the reason why the TE polarization has a thinner nanojet waist is given, it is related to the longitudinal component making light transmission far away from optical axis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-flux plasma exposure of ultra-fine grain tungsten

Here we examine the response of an ultra-fine grained (UFG) tungsten material to high-flux deuterium plasma exposure. UFG tungsten has received considerable interest as a possible plasma-facing material in magnetic confinement fusion devices, in large part because of its improved resistance to neutron damage. However, optimization of the material in this manner may lead to trade-offs in other properties. Moreover, we address two aspects of the problem in this work: (a) how high-flux plasmas modify the structure of the exposed surface, and (b) how hydrogen isotopes become trapped within the material. The specific UFG tungsten considered here contains 100 nm-width Ti dispersoids (1 wt%) that limit the growth of the W grains to a median size of 960 nm. Metal impurities (Fe, Cr) as well as O were identified within the dispersoids; these species were absent from the W matrix. To simulate relevant particle bombardment conditions, we exposed specimens of the W-Ti material to low energy (100 eV), high-flux (> 10 22 m -2 s -1 ) deuterium plasmas in the PISCES-A facility at the University of California, San Diego. To explore different temperature-dependent trapping mechanisms, we considered a range of exposure temperatures between 200 °C and 500 °C. For comparison, we also exposed reference specimens of conventional powder metallurgy warm-rolled and ITER-grade tungsten at 300 °C. Post-mortem focused ion beam profiling and atomic force microscopy of the UFG tungsten revealed no evidence of near-surface bubbles containing high pressure D2 gas, a common surface degradation mechanism associated with plasma exposure. Thermal desorption spectrometry indicated moderately higher trapping of D in the material compared with the reference specimens, though still within the spread of values for different tungsten grades found in the literature database. Finally, for the criteria considered here, these results do not indicate any significant obstacles to the potential use of UFG tungsten as a plasma-facing material, although further experimental work is needed to assess material response to transient events and high plasma fluence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Multiple Coulomb scattering in acrylic of a 221.3 MeV therapeutic proton beam

Measurements of multiple Coulomb scattering (MCS) distributions for 221.3 MeV therapeutic protons are presented using a novel detector system comprised of a thin scintillator, a pellicle mirror, and a digital camera. The MCS distributions were characterized for three acrylic phantoms of varying lengths and for two biological density-equivalent phantoms simulating bone and muscle. Additionally, beam profiles were measured across an energy range of 80.3–221.3 MeV in 20 MeV increments. The observed energy dependence of the photon yields is consistent with the tabulated stopping power values. Finally, the experimental results are benchmarked against Geant4 simulations, demonstrating consistent agreement and validating the capability of the detector system for radiology measurements.

Digital camera↗

Characterization of flowing liquid films as a regenerating plasma mirror for high repetition-rate laser contrast enhancement

In this paper, we characterize a high repetition-rate regenerating plasma mirror produced by the thin film of liquid formed when two laminar streams collide. The use of a flowing liquid film is inexpensive and the interaction surface refreshes automatically, avoiding buildup of on-target debris. The composition of the liquid material and the relative angle of the film-generating nozzles was optimized for this application. Spectra measured in reflection from a water-based plasma mirror showed a blue shift but an optical reflectivity of up to 30%. The thickness of the film was found to be of the order of 2 μm, and the stability of the reflected spot was ≈1 mrad. The reflected beam profile was highly distorted but stable. Further optimization of the nozzles to affect the fluid flow should enable significant improvements in control of the fluid films and increase in the reflectivity of these mirrors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution

Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Perfect X-ray focusing via fitting corrective glasses to aberrated optics

Due to their short wavelength, X-rays can in principle be focused down to a few nanometres and below. At the same time, it is this short wavelength that puts stringent requirements on X-ray optics and their metrology. Both are limited by today’s technology. In this work, we present accurate at wavelength measurements of residual aberrations of a refractive X-ray lens using ptychography to manufacture a corrective phase plate. Together with the fitted phase plate the optics shows diffraction-limited performance, generating a nearly Gaussian beam profile with a Strehl ratio above 0.8. As a result, this scheme can be applied to any other focusing optics, thus solving the X-ray optical problem at synchrotron radiation sources and X-ray free-electron lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially dispersive circular photogalvanic effect in a Weyl semimetal

Weyl semimetals (WSMs) are gapless topological states of matter with broken inversion and/or time reversal symmetry. WSMs can support a circulating photocurrent when illuminated by circularly polarized light at normal incidence. Here, we report a spatially dispersive circular photogalvanic effect (s-CPGE) in a WSM that occurs with a spatially varying beam profile. Our analysis shows that the s-CPGE is controlled by a symmetry selection rule combined with asymmetric carrier excitation and relaxation dynamics. By evaluating the s-CPGE for a minimal model of a WSM, a frequency-dependent scaling behaviour of the photocurrent is obtained. Wavelength-dependent measurements from the visible to mid-infrared range show evidence of Berry curvature singularities and band inversion in the s-CPGE response. Here, we present the s-CPGE as a promising spectroscopic probe for topological band properties, with the potential for controlling photoresponse by patterning optical fields on topological materials to store, manipulate and transmit information.

36 MATERIALS SCIENCE↗

New aspects of longitudinal instabilities in electron storage rings

Here, novel features of the longitudinal instability of a single electron bunch circulating in a low-emittance electron storage ring are discussed. Measurements and numerical simulations, performed both in time and frequency domain, show a non-monotonic increase of the electron beam energy spread as a function of single bunch current, characterized by the presence of local minima and maxima, where a local minimum of the energy spread is interpreted as a higher-order microwave instability threshold. It is also shown that thresholds related to the same zero-intensity bunch length depend linearly on the accelerating radio frequency voltage. The observed intensity-dependent features of the energy spread, confirmed by measurements with two independent diagnostics methods, i.e. horizontal beam profile measurements by a synchrotron light monitor and photon energy spectrum measurements of undulator radiation, are given a theoretical interpretation by applying a novel eigenvalue analysis based on the linearized Vlasov equation.

43 PARTICLE ACCELERATORS↗

Optimizing microfluidic flow cell geometry for in situ resonant soft X-ray characterization of molecular nanostructures

Liquid-phase resonant soft X-ray scattering (LP-RSoXS) is an emerging label-free technique to probe chemically resolved nanostructures of molecular or hybrid materials in liquid environments. Still, quantitative analysis is hindered by the pressure-induced deformation of thin silicon nitride (SiN) membranes used as windows in microfluidic flow cells, which attenuates the signal in nonlinear ways, making experimental optimization difficult. Here, in this work, we directly characterize this deformation under experimental conditions for a variety of cell configurations. We use this to develop a predictive model that combines transmission effects of SiN bowing, incident X-ray beam profiles, and material-dependent resonant scattering cross sections to simulate the effective scattering intensity at the detector across the carbon K-edge. Maps of the total signal across the flow cell window reveal that increasing the window width and polymer concentration shifts the anisotropic intensity distributions from the center toward the edges of the window. It was determined that an optimal SiN thickness of 50 nm, with a window aperture of 104 μm, maximizes the total signal for typical solute concentrations and energies across the carbon K-edge. Our results overturn the assumption that corner regions dominate the scattering signal, offering explicit design guidelines for maximizing LP-RSoXS signals and significantly advancing the quantitative application of this technique to the characterization of molecular and hybrid nanostructured materials in liquids.

Grabner, Devin [Washington State Univ., Pullman, W↗