Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM LINES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Radiation damage study of POCO ZXF-5Q graphite for neutrino production targets using 4.5 MeV helium ions

To address the challenges of increased beam power and target survivability associated with next-generation particle production beam lines, high dose, high-energy proton beam conditions are simulated using irradiation from low-energy ion beams. A low-energy ion irradiation study of POCO ZXF-5Q graphite under conditions similar to those of the NuMI NT-02 neutrino production target at the Fermi National Accelerator Laboratory is reported. Helium ion irradiation was performed at 100 ∘ C to a maximum damage level of 0.9 displacements per atom (DPA). Irradiation induced hardening, swelling of the irradiated region, inter-plane lattice expansion, and intraplane lattice contraction with increasing ion fluence was observed using micromechanical (nanoindentation, atomic force microscopy) and electron microscopy (high-resolution imaging, selected area diffraction) characterization. Similar changes were also observed in post irradiation examination of the NT-02 target indicating that ion irradiation can be a valuable tool for estimating radiation damage in proton beam targets. Caution must be exercised though, because the hardening, lattice alteration, and swelling occur to different magnitudes for a given damage level. The observed hardening and embrittlement were greater for ion irradiated graphite. For He ion irradiated samples the lattice spacing changes were smaller at low damage levels (78% less expansion and 71% less contraction at 0.1 DPA) and larger at high damage levels (38% more expansion and 5% more contraction at 0.9 DPA) relative to that observed in the NT-02 target. The magnitude of swelling was 8.5× greater under ion irradiation which is influenced by the differing damage gradients and inclusion of implanted He ions in the region of interest.

43 PARTICLE ACCELERATORS↗

The electron cyclotron resonance ion source with arc-shaped coils concept (invited)

The main limitation to further improve the performance of ECR ion sources is set by the magnet technology related to the multipole magnet field used for the closed minimum-B structure. The JYFL ion source group has sought different approaches to improve the strength of the minimum-B structure required for the production of highly charged ion beams. It was found out that such a configuration can be realized with arc shaped coils. The first prototype, electron cyclotron resonance ion source with arc-shaped coils (ARC-ECRIS), was constructed and tested at JYFL in 2006. It was confirmed that such an ion source can be used for the production of highly charged ion beams. Regardless of several cost-driven compromises such as extraction mirror ratio of 1.05-1.2, microwave frequency of 6.4 GHz, and beam line with limited capacity, Ar{sup 4+} beam intensity of up to 2 {mu}A was measured. Subsequent design study has shown that the ARC-ECRIS operating at the microwave frequency above 40 GHz could be constructed. This specific design would be based on NbTi-wires and it fulfills the experimental magnetic field scaling laws. In this article, the ARC-ECRIS concept and its potential applications will be described.

43 PARTICLE ACCELERATORS↗

Ground motion improvements in SPEAR3

SPEAR3 is a third-generation synchrotron light source storage ring, about 234 meters in circumference. To meet the beam stability requirement, our goal is to ultimately achieve an orbit variation (relative to the photon beam lines) of less than 10% of the beam size, which is about 1 micron in the vertical plane. Hydrostatic leveling system (HLS) measurements show that the height of the SPEAR3 tunnel floor can vary by tens of microns daily without thermal insulation improvements. We present an analysis of the HLS data that shows that adding thermal insulation to the concrete walls of the storage ring tunnel dramatically decreased diurnal tunnel floor motion.

43 PARTICLE ACCELERATORS↗

Kilovoltage energy imaging with a radiotherapy linac with a continuously variable energy range

Purpose: In this paper, the effect on image quality of significantly reducing the primary electron energy of a radiotherapy accelerator is investigated using a novel waveguide test piece. The waveguide contains a novel variable coupling device (rotovane), allowing for a wide continuously variable energy range of between 1.4 and 9 MeV suitable for both imaging and therapy.Method: Imaging at linac accelerating potentials close to 1 MV was investigated experimentally and via Monte Carlo simulations. An imaging beam line was designed, and planar and cone beam computed tomography images were obtained to enable qualitative and quantitative comparisons with kilovoltage and megavoltage imaging systems. The imaging beam had an electron energy of 1.4 MeV, which was incident on a water cooled electron window consisting of stainless steel, a 5 mm carbon electron absorber and 2.5 mm aluminium filtration. Images were acquired with an amorphous silicon detector sensitive to diagnostic x-ray energies. Results: The x-ray beam had an average energy of 220 keV and half value layer of 5.9 mm of copper. Cone beam CT images with the same contrast to noise ratio as a gantry mounted kilovoltage imaging system were obtained with doses as low as 2 cGy. This dose is equivalent to a single 6 MV portal image. While 12 times higher than a 100 kVp CBCT system (Elekta XVI), this dose is 140 times lower than a 6 MV cone beam imaging system and 6 times lower than previously published LowZ imaging beams operating at higher (4-5 MeV) energies. Conclusions: The novel coupling device provides for a wide range of electron energies that are suitable for kilovoltage quality imaging and therapy. The imaging system provides high contrast images from the therapy portal at low dose, approaching that of gantry mounted kilovoltage x-ray systems. Additionally, the system provides low dose imaging directly from the therapy portal, potentially allowing for target tracking during radiotherapy treatment. There is the scope with such a tuneable system for further energy reduction and subsequent improvement in image quality.

43 PARTICLE ACCELERATORS↗

FRIB Transition to User Operations, Power Ramp Up, and Upgrade Perspectives

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. During the first 12 months of user operations, the FRIB accelerator complex delivered 5250 beam hours, including 1528 hours to nine science experiments conducted with primary beams of 36Ar, 48Ca, 70Zn, 82Se, 124Xe, and 198Pt at beam energies >200 MeV/u; 2724 hours for beam developments, studies, and tuning; and 998 hours to industrial users and non-scientific programs using the FRIB Single Event Effect (FSEE) beam line. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on FRIB status and progress since SRF2021, emphasizing lessons learned during the transition from beam commissioning to machine operations, challenges and resolutions for the power ramp-up, progress with accelerator improvements, and R&D for the energy upgrade.

43 PARTICLE ACCELERATORS↗

Status and Plans for a Superconducting RF Accelerator Test Facility at Fermilab

The Advanced Superconducting Test Accelerator (ASTA) is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration section consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beam lines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of generating a 750 MeV electron beam with ILC beam intensity. An expansion of this facility was recently completed that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. Two new buildings were also constructed adjacent to the ASTA facility to house a new cryogenic plant and multiple superconducting RF (SRF) cryomodule test stands. In addition to testing accelerator components, this facility will be used to test RF power systems, instrumentation, and control systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

43 PARTICLE ACCELERATORS↗

The DarkLight Experiment at the JLab FEL

DarkLight will study the production of gauge bosons associated with Dark Forces theories in the scattering of 100 MeV electrons on proton a target. DarkLight is a spectrometer to measure all the final state particles in e^- +p --> e^- +p + e^- + e^+. QED allows this process and the invariant mass distribution of the e+e- pair is a continuum from nearly zero to nearly the electron beam energy. Dark Forces theories, which allow the dark matter mass scale to be over 1 TeV, predict a gauge boson A' in the mass range of 10-1,000 MeV and decays to an electron-positron pair with an invariant mass of mA'. We aim to search for this process using the 100 MeV, 10 mA electron beam at the JLab Free Electron Laser impinging on a hydrogen target with a 10^19cm^?2 density. The resulting luminosity of 6×10^35/cm^2-s gives the experiment enough sensitivity to probe A' couplings of 10?9a. DarkLight is unique in its design to detect all four particles in the final state. The leptons will be measured in a large high-rate TPC and a silicon sensor will measure the protons. A 0.5 T solenoidal magnetic field provides the momentum resolution and focuses the copious Moeller scattering background down the beam line, away from the detectors. A first beam test has shown the FEL beam is compatible with the target design and that the hall backgrounds are manageable. The experiment has been approved by Jefferson Lab for first running in 2017.

Fisher, Peter↗

Initial Emittance Measurements of the Fermilab Linac Beam Using the MTA Beamline

The MTA beam line has been specifically designed to facilitate measurements of the Fermilab Linac beam emittance and properties utilizing a long, 10m, element-free straight. Linac beam is extracted downstream of the 400-MeV electrostatic chopper located in the Booster injection line. This chopper cannot be utilized for MTA beam, and therefore the entire Linac beam pulse is directed into the MTA beamline. Pulse length manipulation is provided by the 750-keV electrostatic chopper at the upstream end of the Linac and, using this device, beam can be delivered from 8 μsec up to the full 50 μsec Linac pulse length. The 10 m emittance measurement straight exploits and begins at the 12' shield wall that separates the MTA Experimental Hall and beamline stub from the Linac enclosure. A quadrupole triplet has been installed upstream of the shield wall in order to focus a large, 1.5-2' (~95% width) beam through the shield wall and onto a profile monitor located at the exit of the shielding. Another profile monitor has been installed upstream of the shield wall, ~5 m upstream of the central, or focal-point monitor. With the triplet, a small, 0.2-0.5' spot size was produced for the initial measurement reported here. As will be shown in this report, a small, approximate beam waist located near a center profile monitor reduces the number of unknown linear optical parameters to two Courant-Snyder parameters, β and ε, since, α, or the rotation of the phase ellipse can be determined by propagating the beam envelope from this waist (using the simple linear transfer matrix that describes a drift).

43 PARTICLE ACCELERATORS↗

Measurement of the density profile of pure and seeded molecular beams by femtosecond ion imaging

Here, we report on femtosecond ion imaging experiments to measure the density profile of a pulsed supersonic molecular beam. Ion images are measured for both a molecular beam and bulk gas under identical experimental conditions via femtosecond multiphoton ionization of Xe atoms. We report the density profile of the molecular beam, and the measured absolute density is compared with theoretical calculations of the centre line beam density. Subsequently, we discuss reasons accounting for the differences between measurements and calculations and propose that strong skimmer interference is the most probable cause for the differences. Furthermore, we report on experiments measuring the centre line density of seeded supersonic beams. The femtosecond ion images show that seeding the heavy Xe atom at low relative seed fractions (1%-10%) in a light carrier gas like Ne results in strong relative enhancements of up to two orders of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The cyclotron laboratory and the RFQ accelerator in Bern

Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

07 ISOTOPE AND RADIATION SOURCES↗

Beam properties and stability of a flattening-filter free 7 MV beam--An overview

Purpose: Several works have recently focused on flattening-filter-free (FFF) beams of linear accelerators of various companies (in particular, Varian and Elekta), but no overview as yet exists for the flattening-filter free 7XU beam (Siemens Artiste). Methods: Dosimetric properties of the 7XU beam were measured in May and September 2011. We present depth dose curves and beam profiles, output factors, and MLC transmission and assess the stability of the measurements. The 7XU beam was commissioned in the Pinnacle Superscript-Three treatment planning system (TPS), and modeling results including the spectrum are presented. Results: The percent depth dose curve of the 7XU beam is similar to the flat 6X beam line, with a slightly smaller surface dose. The beam profiles show the characteristic shape of flattening-filter free beams, with deviations between measurements of generally less than 1%. The output factors of the 7XU beam decrease more slowly than for the 6X beam. The MLC transmission is comparable but slightly less for the 7XU beam. The 7XU beam can be adequately modeled by the Pinnacle Superscript-Three TPS, with successful dosimetric verification. The spectrum of the 7XU beam has lower photon fluence up to approximately 2.5 MeV and higher fluence beyond, with a slightly higher mean energy. Conclusions: The 7XU beam has been commissioned for clinical use after successful modeling, stability checks, and dosimetric verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contextual modeling and Bayesian Optimization for Improved Injection at the Fermilab Booster

The Fermilab accelerator complex delivers high-intensity proton beams to serve the lab’s neutrino, muon, and fixed-target programs. A normal-conducting Linac accelerates H− beam to 400 MeV and injects into the Booster rapid cycling synchrotron via charge exchange, which accelerates protons to 8 GeV. Injection from the Linac into the Booster is a critical area for high-power performance of the Fermilab proton complex. The Booster is a high-intensity proton ring with extreme space-charge forces which necessitates precise control over the beam losses through the acceleration cycle. The main challenge for the reliability of Booster performance is compensating for drifting conditions in the beam from the Linac, which can drift daily in energy by up to O(1) MeV w.r.t. design. Drifts in Linac orbit and energy must be corrected to match the Booster, while simultaneously accommodating interdependent drifts in transverse and longitudinal beam quality. Operationally, compensation for these changes is addressed by manual tuning of the Linac output energy and/or Booster acceptance, which can be inefficient and time-consuming. This works describes contextual Bayesian Optimization for injection tuning that takes into account the state of Linac beam via information from instrumentation in the injection line (Beam position monitors (BPMs), beam loss monitors (BLMs), wire scanners for transverse profiles (WSs)), as well as RF cavity setting parameters from the Linac.

Sharankova, R. [Fermilab] (ORCID:000000027014593X)↗

Mechanical Design of a High Energy Beam Absorber for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab

A high energy beam absorber has been built for the Advanced Superconducting Test Accelerator (ASTA) at Fermilab. In the facility's initial configuration, an electron beam will be accelerated through 3 TTF-type or ILC-type SRF cryomodules to an energy of 750MeV. The electron beam will be directed to one of multiple downstream experimental and diagnostic beam lines and then deposited in one of two beam absorbers. The facility is designed to accommodate up to 6 cryomodules, which would produce a 75kW beam at 1.5GeV; this is the driving design condition for the beam absorbers. The beam absorbers consist of water-cooled graphite, aluminum and copper layers contained in a helium-filled enclosure. This paper describes the mechanical implementation of the beam absorbers, with a focus on thermal design and analysis. The potential for radiation-induced degradation of the graphite is discussed.

43 PARTICLE ACCELERATORS↗

Experimental results of beryllium exposed to intense high energy proton beam pulses

Beryllium is extensively used in various accelerator beam lines and target facilities as a material for beam windows, and to a lesser extent, as secondary particle production targets. With increasing beam intensities of future accelerator facilities, it is critical to understand the response of beryllium under extreme conditions to reliably operate these components as well as avoid compromising particle production efficiency by limiting beam parameters. As a result, an exploratory experiment at CERN’s HiRadMat facility was carried out to take advantage of the test facility’s tunable high intensity proton beam to probe and investigate the damage mechanisms of several beryllium grades. The test matrix consisted of multiple arrays of thin discs of varying thicknesses as well as cylinders, each exposed to increasing beam intensities. This paper outlines the experimental measurements, as well as findings from Post-Irradiation-Examination (PIE) work where different imaging techniques were used to analyze and compare surface evolution and microstructural response of the test matrix specimens.

43 PARTICLE ACCELERATORS↗

Impact of High Energy νe (ν¯e) Events on NOvA Oscillation Sensitivities

NOvA is a two detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. It is primarily designed to constraint neutrino oscillation parameters using muon neutrino (anti-neutrino) disappearance data and electron neutrino (anti-neutrino) appearance data. NOvA detects neutrinos from Fermilab’s Neutrinos at Main Injector (NuMI) beam-line. The un-oscillated muon neutrino and beam $\nu_e$ events are observed by the NOvA Near Detector (ND), which is 100m underground and at a distance of 1km from the beam source. The Far Detector (FD), situated 809 km away from the ND, is in Ash River, MN, USA, and observes $\nu_\mu$ and $\nu_e$ events after oscillations. Traditionally, NOvA has used $\nu_e$ events in the energy range 1 < E < 4 GeV for 3-flavor neutrino oscillation analyses to constraint the neutrino oscillation parameters. In this study we looked at the impact of including high-energy neutrino events with energies up to 12 GeV in the analysis with the aim of constraining the beam electron neutrino/antineutrino background events. Event count predictions after adding this high-energy sample events and latest three flavor oscillation results of the NOvA experiment are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of the nature of the confinement in the GlueX experiment

Confinement is a fundamental property of quantum chromodynamics (QCD) associated with the unique role of the gluonic field responsible for binding quarks in hadrons. Understanding the role of gluons in the confinement of quarks is one of the most tantalizing topics in modern particle physics to be explored. The new experiment GlueX has been recently constructed at Jefferson Lab. The experiment was designed to search for hybrid mesons with exotic quantum numbers using a beam of linearly polarized photons incident on a liquid hydrogen target. The spectrum of these states and their mass splitting from normal mesons may yield information on confinement. In addition, these observations in combination with detailed chromodynamics calculations such as on the Lattice can provide important tests for our understanding of the role of gluons. The production of exotic mesons is expected to be enhanced in p interactions, where the experimental data is very limited. We present the description of the GlueX detector, beam line, and first results of the commissioning with photon beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beams (LAMFI-USP) by the {sup 10}B(p,αγ({sup 7}Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 10{sup 16} at/cm{sup 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗