Accelerator electron beam current and electron energy measuring device with negligible beam interference during accelerator operation
In the laser ion source (LIS) at the Brookhaven National Laboratory (BNL), a solenoid is used to guide the laser ablation plasma and modulate the extracted beam current. Many types of ion species are guided. In some cases, the plasma plume is injected into the solenoid away from the solenoidal axis. To investigate the effects of the solenoid on the beam extracted from the plasma that has different properties, the beam current was measured in the setup of the LIS at the BNL. The beam current of Li, Al, Si, Fe, and Au increased when the magnetic field was applied. For most of the species the peak current and the total charge within a single beam pulse increased around 10 times with a magnetic field less than 100 G. In addition, for some species the rate of increase of the peak currents became smaller when the magnetic flux densities were larger than certain values depending on the species. In this case, the current waveforms were distorted. At the same magnetic field value, the field was more effective on lighter species than on heavier ones. When plasma was injected offset from the axis of the solenoid, peak current and total charge became half of those without offset. The experimental data are useful for the operation of the LIS at the BNL.
SuperB aims at the construction of a very high luminosity (10{sup 36} cm{sup -2} s{sup -1}) asymmetric e{sup +}e{sup -} Flavour Factory, with possible location at the campus of the University of Rome Tor Vergata, near the INFN Frascati National Laboratory. In this paper the basic principles of the design and details on the lattice are given. SuperB is a new machine that can exploit novel very promising design approaches: (1) large Piwinski angle scheme will allow for peak luminosity of the order of 10{sup 36} cm{sup -2} s{sup -1}, well beyond the current state-of-the-art, without a significant increase in beam currents or shorter bunch lengths; (2) 'crab waist' sextupoles will be used for suppression of dangerous resonances; (3) the low beam currents design presents reduced detector and background problems, and affordable operating costs; (4) a polarized electron beam can produce polarized {tau} leptons, opening an entirely new realm of exploration in lepton flavor physics. SuperB studies are already proving useful to the accelerator and particle physics communities. The principle of operation is being tested at DAFNE. The baseline lattice, based on the reuse of all PEP-II hardware, fits in the Tor Vergata University campus site, near Frascati. A CDR is being reviewed by an International Review Committee, chaired by J. Dainton (UK). A Technical Design Report will be prepared to be ready by beginning of 2010.
The upgrade of the diagnostic neutral beam injector RUDI in 2010 was performed to increase the beam density at the focal plane in accordance with the requirements of charge-exchange recombination spectroscopy diagnostics. A new focusing ion-optical system (IOS) with slit beamlets and an enlarged aperture was optimized for 50% higher nominal beam current and reduced angular divergence with respect to the previous multi-aperture IOS version. The upgraded injector provides the beam current up to 3 A, the measured beam divergence in the direction along the slits is 0.35 deg. Additionally, the plasma generator was modified to extend the beam pulse to 8 s.
In the framework of the future project FAIR several upgrade programs and construction of new facilities are in progress such as the U{sup 4+} upgrade for the existing high current injector and the new 70 MeV proton injector. For both injectors solenoids in the low energy beam transport section are foreseen to inject the beam into the following rf accelerator. The paper presents beam quality measurements of high current ion beams behind a solenoid using a slit-grid emittance measurement device, viewing targets, and a pepper pot measurement device at the high current test bench at GSI.
A solar cell on a wafer of multicrystalline silicon containing grain boundaries was studied by the induced-current method. The sample was scanned by an electron beam and by a laser beam at two wavelengths (980 and 635 nm). The recorded induced-current maps were aligned by means of a specially developed code, that enabled to analyze the same part of the grain boundary for three types of measurements. Optimization of the residual between simulated induced-current profiles and those obtained experimentally yielded quantitative estimates of the characteristics of a sample and its defects: the diffusion length of minority carriers and recombination velocity at the grain boundary.
We report values of minority carrier diffusion length in n-type 6H SiC measured using a planar Electron Beam Induced Current (EBIC) method. Values of hole diffusion length in defect free regions of n-type 6H SiC, with a doping concentration of 1.7El7 1/cu cm, ranged from 1.46 microns to 0.68 microns. We next introduce a novel variation of the planar method used above. This 'planar mapping' technique measured diffusion length along a linescan creating a map of diffusion length versus position. This map is then overlaid onto the EBIC image of the corresponding linescan, allowing direct visualization of the effect of defects on minority carrier diffusion length. Measurements of the above n-type 6H SiC resulted in values of hole diffusion length ranging from 1.2 micron in defect free regions to below 0.1 gm at the center of large defects. In addition, measurements on p-type 6H SiC resulted in electron diffusion lengths ranging from 1.42 micron to 0.8 micron.
Design of an electron source of triode type is described, which produces a radial converging electron beam employed for modification of the outer surface of fuel element claddings. Experimental investigations of the source showed that beam current magnitude, efficiency of beam focusing to the target, stability of source operation, and beam pulse duration become worse when the target diameter drops below certain values. A method for the calculation of the source operation was developed. Calculations showed that the reason of worse source operation is the initial angular spread of electrons when the target diameter is small. Because of the angular spread a part of electrons passes by the target and oscillates between the target and cathode. The space charge of the oscillating electrons lowers the emission current magnitude and leads to the formation of a virtual cathode in the grid-target gap despite the fact that the emission beam current is less than the limiting one. Formation of a virtual cathode is a reason for the unstable source operation and restriction of the beam pulse duration. Recommendations for the improvement of the source design are suggested.
The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed-neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. The accelerator system is fed by an RF-driven, multicusp, H - ion source which nominally provides pulsed beam currents of 50-60 mA (1ms, 60Hz). This report provides a discussion of ongoing design improvements to the SNS ion source and Low Energy Beam Transport (LEBT) as well as diagnostic upgrades undertaken since the previous ICIS conference. These improvements include (i) simple mechanical modifications to the source outlet aperture which resulted in dramatically increased extracted beam current and comparable or lower emittance at similar beam currents, (ii) design improvements to the LEBT chopper target which will enable full power beam-dumping during physics studies, (iii) refinement of the SNS Allison emittance scanner that has enabled the first reliable LEBT beam measurements at full beam power (65kV, 50-100mA, 1ms, 60Hz) on the SNS ion source test stand and (iv) the implementation of a thermal imaging camera for the monitoring the LEBT electrode temperatures. (v) The design of an advanced Cs system, capable of more efficient Cs utilization with significantly lower Cs losses from the source is also presented. Mechanical details, computational simulations and experimental results are discussed within the context of these improvements.
A complex chaotic dynamics in a gyrotron was experimentally observed under conditions of high supercriticality corresponding to 1000–1500-fold excess of the beam current parameter over the starting value. At electron beam currents typical of gyrotron test setups, this excess has been achieved by a transition to excitation of the lowest mode of a cylindrical waveguide. Chaotic generation regimes were observed in a 33 GHz frequency range with a spectral width of 500 MHz and record narrow relative width below 1.5% These results imply considerable progress in comparison to previous experiments with gyrotron type devices and are in good agreement with theoretical analysis based on a system of averaged evolution equations derived with allowance for finiteness of the transit time of electrons via the interaction space.
Extreme ultraviolet (EUV) spectra of highly charged iron ions in a wavelength range of 100-300 A have been observed from two different plasma sources of the Tokyo Electron Beam Ion Trap (Tokyo-EBIT) with a monoenergetic electron beam and a Large Helical Device (LHD) with Maxwellian electron energy. The excitation process of the spectral lines is compared between the two plasmas, and it is found that the excitation process for Fe XIX - Fe XXII ions is clearly different. Namely, the EUV emission lines from the EBIT plasma are only dominated by electron impact excitation connected to the ground state, but the excitation mechanism is not so simple in the LHD plasma. The difference in the excitation process is studied by measuring the intensity ratio of EUV emission lines (114.412 A [1s{sup 2}2s2p{sup 2} {sup 2}P{sub 3/2}{yields}1s{sup 2}2s{sup 2}2p {sup 2}P{sub 3/2}]/117.144 A [1s{sup 2}2s2p{sup 2} {sup 2}P{sub 1/2}{yields}1s{sup 2}2s{sup 2}2p {sup 2}P{sub 1/2}]) arising from different ground levels in the Fe XXII ions. The line intensity ratio has an extremely small value of 0.2 in the EBIT plasma with a low beam current of 30 mA and a beam energy of 2 keV, while the ratio varies with the electron density n{sub e} in the LHD plasmas, i.e., 0.35 for n{sub e} = 1 x 10{sup 13} cm{sup -3} and 0.65 for n{sub e} = 4 x 10{sup 13} cm{sup -3}. Here, the electron density of the EBIT plasma is estimated to be smaller than 10{sup 12} cm{sup -3} and the electron temperature of the LHD plasmas is 2 keV. The dependence of the line intensity ratio on the observed electron density is analyzed for both the EBIT and the LHD plasmas using several collisional-radiative (CR) models. The present experimental data can easily be reproduced by the analysis when the thermal proton impact excitation is taken into account. The importance of the proton impact excitation is also experimentally verified by injecting an iron pellet into the LHD plasmas and changing the ratio of the proton density to the electron density.
To avoid regular maintenance, invasive plasma diagnostics with probes are not included in the inductively coupled plasma (ICP) based ITER Neutral Beam (NB) source design. Even non-invasive probes like optical emission spectroscopic diagnostics are also not included in the present ITER NB design due to overall system design and interface issues. As a result, negative ion beam current through the extraction system in the ITER NB negative ion source is the only measurement which indicates plasma condition inside the ion source. However, beam current not only depends on the plasma condition near the extraction region but also on the perveance condition of the ion extractor system and negative ion stripping. Nevertheless, inductively coupled plasma production region (RF driver region) is placed at distance (∼ 30cm) from the extraction region. Due to that, some uncertainties are expected to be involved if one tries to link beam current with plasma properties inside the RF driver. Plasma characterization in source RF driver region is utmost necessary to maintain the optimum condition for source operation. In this paper, a method of plasma density estimation is described, based on density dependent plasma load calculation.
Erosion of the leading edge a low-energy high-current electron beam injected into a low-pressure neutral gas under conditions of virtual cathode formation in the absence of an external magnetic field is studied theoretically. Beam losses are calculated as functions of the pressure and sort of gas, beam electron energy, and system geometry. The dependence of the duration of the leading edge erosion on the system parameters is analyzed.
We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.
The electrical and optical properties of dislocation arrays (DAs) in 4H-SiC homoepitaxial layers were studied by using electron-beam-induced current (EBIC) and cathodoluminescence (CL) techniques. EBIC observations show that under electron-beam irradiation, the DAs are easily dissociated to form rhombic stacking faults (SFs), whereas the single threading dislocations are not. CL results demonstrate that a new peak (417 nm) appears at the formed SFs, which is the same as the phenomenon observed from dissociating basal plane dislocations. The dissociation mechanisms of DAs are proposed based on the assumption that small basal segments exist. The dissociation velocity of each dislocation in the DAs is discussed according to its recombination activity.
Examined in this report are the experimental steady-state gains, or changes, in beam-current output with changes in thrustor inputs for a 10-centimeter-diameter electron-bombardment ion thrustor. A general leveling off of beam current as a function of an input variable was found at the upper range of each variable, At the design operating point, the filament-heating current exhibited the greatest sensitivity, or percentage beam-current output change for a percentage change in the input (2 to 4). Accelerator voltage showed the least effect (0.04) while discharge voltage, magnetic field, and neutral propellant flow exhibited about the same sensitivity (0.4 to 0.5). Some effects of nonlinearity are shown that may require consideration in the design of a closed-loop control system.
The beam power of the Linac for the Second Target Station (STS) at the Spallation Neutron Source (SNS) will be doubled to 2.8 MW. For the energy upgrade, seven additional cryomodules will be installed in the reserved space at the end of the linac tunnel to produce linac output energy of 1.3 GeV. The cryomodules for STS will have the same physical length but will incorporate some design changes based on the lessons learned from operational experience over the last 10 years and from the high beta spare cryomodule developed in house. The average macro-pulse beam current for the STS will be 38 mA which is about a 40 % increase from the present beam current for 1.4 MW operation. Plans for the new cryomodules and for the existing cryomodules to support higher beam current for the STS are presented in this paper.
A laser ion source (LIS) can easily provide a high current beam. However, it has been difficult to obtain a longer beam pulse while keeping a high current. On occasion, longer beam pulses are required by certain applications. For example, more than 10 {mu}s of beam pulse is required for injecting highly charged beams to a large sized synchrotron. To extend beam pulse width, a solenoid field was applied at the drift space of the LIS at Brookhaven National Laboratory. The solenoid field suppressed the diverging angle of the expanding plasma and the beam pulse was widened. Also, it was observed that the plasma state was conserved after passing through a few hundred gauss of the 480 mm length solenoid field.