Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Atomic force microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Sensitive Technique Developed Using Atomic Force Microscopy to Measure the Low-Earth-Orbit Atomic Oxygen Erosion of Polymers

A recession measurement technique has been developed at the NASA Glenn Research Center to determine the atomic oxygen durability of polymers exposed to the space environment for short durations. Polymers such as polyimide Kapton and Teflon FEP (fluorinated ethylene propylene, DuPont) are commonly used in spacecraft because of their desirable properties, such as flexibility, low density, and in the case of FEP, low solar absorptance and high thermal emittance. Polymers on the exterior of spacecraft in the low- Earth-orbit environment are exposed to energetic atomic oxygen, resulting in erosion and potential structural loss. It is, therefore, important to understand the atomic oxygen erosion yield (E, the volume loss per incident oxygen atom) of polymers being considered in spacecraft design. Because long-term space exposure data are rare and very costly, short-term exposures, such as on the space shuttles, are often relied on for atomic oxygen erosion determination. The most common technique for determining E is through mass-loss measurements. For limited-duration exposure experiments, such as shuttle flight experiments, the atomic oxygen fluence is often so small that mass-loss measurements are not sensitive enough. Therefore, a recession measurement technique has been developed at Glenn to obtain accurate erosion yields of polymers exposed to low atomic oxygen fluences.

deGroh, Kim D.↗

Hydrothermal Atomic Force Microscopy Investigation of Barite Growth: Role of Spectator Ions in Elementary Step Edge Growth Kinetics and Hillock Morphology [Plus Supporting Information]

Here, to better understand the role of spectator ions in barite growth, the kinetics of step edge growth on barite (001) surfaces were studied under various salt solutions. Hydrothermal atomic force microscopy (HAFM) was used to investigate the effect of background electrolytes (NaCl, NaBr, and NaNO 3 ) as a function of saturation index and ionic strength ( I ) on barite growth sourced at dislocations at 108 °C. Results demonstrate that hillock morphology is affected by I , as well as type of anion, where the prevalence of steps aligned on the [010] direction is highest under Cl – . There is a modest increase in kinetic coefficient of 55–130% with a 10-fold increase in I for each salt. In comparing the kinetic coefficients of the salts at low ionic strength (0.01 M), there is a moderate difference, suggesting that the anion may play a role in barium attachment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of the local density of states in self-assembled GeSi/Si(001) nanoislands by combined scanning tunneling and atomic-force microscopy

The local density of states in self-assembled GeSi/Si(001) nanoislands is investigated for the first time by combined tunneling and atomic-force scanning microscopy. Current images and tunneling spectra of individual GeSi/Si(001) islands are obtained. These measurements yield the spatial and energy distributions of the local density of states in GeSi islands, respectively. The tunneling spectroscopy data demonstrate that uncapped Ge{sub 0.3}Si{sub 0.7}/Si(001) islands behave as type-I heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved spatial resolution for spot sampling in thermal desorption atomic force microscopy – mass spectrometry via rapid heating functions

The key to advancing materials is to understand and control their structure and chemistry. However, thorough chemical characterization is challenging since existing techniques characterize only a few properties of the specimen, thereby necessitating multiple measurement platforms to acquire the necessary information. The multimodal combination of atomic force microscopy (AFM) and mass spectrometry (MS) transcends existing analytical capabilities for nanometer scale spatially resolved correlation of the chemical and physical properties of a sample surface. One such hybrid system employs heated AFM cantilevers for thermal desorption (TD) sampling of molecules from a surface and subsequent gas phase ionization and detection of the liberated species by MS. Here in this paper, we report on the use of voltage pulse trains to tailor cantilever heating such that spot sampling size was reduced and mass spectral signal was improved compared to constant voltage, static heating of the cantilever. Desorption efficiency (DE), defined as the quotient of the mass spectral signal intensity and the volume of the desorption crater, was used to judge the effectiveness of a particular tailored heating function. To guide the development and optimization of the heating functions and aid in interpreting experimental results, a 1D finite element model was developed that predicted the cantilever response to different heating functions. Three tailored heating functions that used different combinations, magnitudes, and durations of rectangular voltage pulses, were used for surface spot sampling. The resultant sampling spot size and DE were compared to the same metrics obtained with the conventional method that uses a single voltage pulse. Using a model system composed of a thin film of ink containing pigment yellow 74 as a model system, desorption craters shrunk from 2 μm, using the conventional approach, to 310 nm using the optimum tailored heating function. This same pulsed heating function produced a 381× improvement in the DE and an 8× improvement in spatial resolution compared to the conventional heating approach showing that signal/amount of material sampled was improved significantly by this new cantilever heating strategy.

36 MATERIALS SCIENCE↗

Material Properties of Zirconium Hydride Phases in Zircaloy-4 Getter Tubes Mapped by Atomic Force Microscopy

Nickel plated Zircaloy-4 tubing (“getter tubing”) is an important functional component in Tritium Producing Burnable Absorber Rods (TBPARs). Getter tubes are used to capture tritium produced during reactor operations and convert it from a gas to a solid by reacting it with Zr to form ZrHx compounds. Previous studies (PNNL-27232, TTP-8-004, and TTP-30710) on forming Zircaloy-4 hydrides demonstrated that hydride concentration gradients formed under prototypic hydriding conditions and that the microstructure of hydrides formed at 350°C is different than those formed at 500°C, a temperature typically used by the Tritium Technology Program (TTP) for getter rate loading experiments. Differences in hydride distribution, microstructure, and phases were characterize using scanning electron microscopy methods. However, the impact of these differences on material properties is not well understood. The goal of this project was to determine whether atomic force microscopy could observe subtle differences in material properties of single domains of hydride phases formed in Zircaloy-4. These properties include surface structure, hardness, thermal conductivity, and magnetic susceptibility.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of enzymes on elastic modulus of low-density lipoproteins were investigated using atomic force microscopy

Highlights: • The elastic modulus of the enzymatically digested LDL was evaluated using AFM. • The LDL elastic modulus was decreased not by proteases but by phospholipase A{sub 2}. • The LDL size was unaffected by proteases or PLA{sub 2}. Oxidation of low-density lipoproteins (LDLs) induces development of cardiovascular disease. Recently, reports of studies using atomic force microscopy (AFM) have described that the elastic modulus of metal-induced oxidized LDLs is lower than the modulus before oxidation. However, the mechanisms of change of the elastic modulus have not been well investigated. We postulated that disorder of the LDL structure might decrease the elastic modulus. This study measured the elastic modulus of LDLs before and after enzyme treatment with V8 protease, α-chymotrypsin, and phospholipase A{sub 2}. After LDLs were obtained from serum by ultracentrifugation, LDLs or enzyme-treated LDLs were physically absorbed. They were crowded on a mica surface. Although V8 protease and α-chymotrypsin did not induce the elastic modulus change, treatment with PLA{sub 2} decreased the elastic modulus. The LDL particle size did not change during the enzyme treatment. Results suggest that disordering of the lipid structure of the LDL might contribute to the elastic modulus change. Results show that AFM might be a useful tool to evaluate disorders of complex nanoscale particle structures from lipids and proteins such as lipoproteins.

60 APPLIED LIFE SCIENCES↗

Determining the Molecular Packing Arrangements on Protein Crystal Faces by Atomic Force Microscopy

Periodic Bond Chain (PBC) analysis of the packing of tetragonal lysozyme crystals have revealed that there are two possible molecular packing arrangements for the crystal faces. The analysis also predicted that only one of these, involving the formation of helices about the 4(sub 3) axes, would prevail during crystal growth. In this study high resolution atomic force microscopy (AFM) was employed to verify these predictions for the (110) crystal face. A computer program was developed which constructs the expected AFM image for a given tip shape for each possible molecular packing arrangement. By comparing the actual AFM image with the predicted images the correct packing arrangement was determined. The prediction of an arrangement involving 4(sub 3) helices was confirmed in this manner,"while the alternate arrangement was not observed. The investigation also showed the protein molecules were packed slightly closer about the 4(sub 3) axes than in the crystallographic arrangement of the crystal interior. This study demonstrates a new approach for determining the molecular packing arrangements on protein crystal faces. It also shows the power of combining a theoretical PBC analysis with experimental high resolution AFM techniques in probing protein crystal growth processes at the molecular level.

Li, Huayu↗

Elucidating nanoscale mechanical properties of diabetic human adipose tissue using atomic force microscopy

Abstract Obesity-related type 2 diabetes (DM) is a major public health concern. Adipose tissue metabolic dysfunction, including fibrosis, plays a central role in DM pathogenesis. Obesity is associated with changes in adipose tissue extracellular matrix (ECM), but the impact of these changes on adipose tissue mechanics and their role in metabolic disease is poorly defined. This study utilized atomic force microscopy (AFM) to quantify difference in elasticity between human DM and non-diabetic (NDM) visceral adipose tissue. The mean elastic modulus of DM adipose tissue was twice that of NDM adipose tissue (11.50 kPa vs. 4.48 kPa) to a 95% confidence level, with significant variability in elasticity of DM compared to NDM adipose tissue. Histologic and chemical measures of fibrosis revealed increased hydroxyproline content in DM adipose tissue, but no difference in Sirius Red staining between DM and NDM tissues. These findings support the hypothesis that fibrosis, evidenced by increased elastic modulus, is enhanced in DM adipose tissue, and suggest that measures of tissue mechanics may better resolve disease-specific differences in adipose tissue fibrosis compared with histologic measures. These data demonstrate the power of AFM nanoindentation to probe tissue mechanics, and delineate the impact of metabolic disease on the mechanical properties of adipose tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Atomic force microscopy of thermally renatured xanthan with low molar mass

Here, this work presents a three-step synthetic procedure to obtain a hypergrafted copolymer composed of a glassy backbone with flexible branched pendant segments. The desired hypergrafted structure was obtained by using a polyfunctional macroinitiator, linear poly(styreneco- 4-hydroxystyrene), to yield polystyrene-graft-hyperbranched polyglycidol with randomly placed branch junctions. Atomic force microscopy, dynamic light scattering, and viscometry probed the aggregation and viscometric behavior of the polymer in DMF and DMF LiBr solutions. The polymer exhibited polyelectrolyte behavior demonstrated by a large increase in the reduced viscosity prior to neutralization with LiBr salt. Additionally, conformational changes were observed by dynamic light scattering in both the average aggregate size and aggregate population with the addition of LiBr salt.

36 MATERIALS SCIENCE↗

Electrical characterization of grain boundaries of CZTS thin films using conductive atomic force microscopy techniques

Graphical abstract: Experimental setup for conducting AFM (C-AFM). - Highlights: • Cu{sub 2}ZnSnS{sub 4} (CZTS) thin film was grown by reactive co-sputtering. • The electronic properties were probed using conducting atomic force microscope, scanning Kelvin probe microscopy and scanning capacitance microscopy. • C-AFM current flow mainly through grain boundaries rather than grain interiors. • SKPM indicated higher potential along the GBs compared to grain interiors. • The SCM explains that charge separation takes place at the interface of grain and grain boundary. - Abstract: Electrical characterization of grain boundaries (GB) of Cu-deficient CZTS (Copper Zinc Tin Sulfide) thin films was done using atomic force microscopic (AFM) techniques like Conductive atomic force microscopy (CAFM), Kelvin probe force microscopy (KPFM) and scanning capacitance microscopy (SCM). Absorbance spectroscopy was done for optical band gap calculations and Raman, XRD and EDS for structural and compositional characterization. Hall measurements were done for estimation of carrier mobility. CAFM and KPFM measurements showed that the currents flow mainly through grain boundaries (GB) rather than grain interiors. SCM results showed that charge separation mainly occurs at the interface of grain and grain boundaries and not all along the grain boundaries.

36 MATERIALS SCIENCE↗

Atomic Force Microscopy of Photosystem II and Its Unit Cell Clustering Quantitatively Delineate the Mesoscale Variability in Arabidopsis Thylakoids

Photoautotrophic organisms efficiently regulate absorption of light energy to sustain photochemistry while promoting photoprotection. Photoprotection is achieved in part by triggering a series of dissipative processes termed non-photochemical quenching (NPQ), which depend on the re-organization of photosystem (PS) II supercomplexes in thylakoid membranes. Using atomic force microscopy, we characterized the structural attributes of grana thylakoids from Arabidopsis thaliana to correlate differences in PSII organization with the role of SOQ1, a recently discovered thylakoid protein that prevents formation of a slowly reversible NPQ state. We developed a statistical image analysis suite to discriminate disordered from crystalline particles and classify crystalline arrays according to their unit cell properties. Through detailed analysis of the local organization of PSII supercomplexes in ordered and disordered phases, we found evidence that interactions among light-harvesting antenna complexes are weakened in the absence of SOQ1, inducing protein rearrangements that favor larger separations between PSII complexes in the majority (disordered) phase and reshaping the PSII crystallization landscape. The features we observe are distinct from known protein rearrangements associated with NPQ, providing further support for a role of SOQ1 in a novel NPQ pathway. The particle clustering and unit cell methodology developed here is generalizable to multiple types of microscopy and will enable unbiased analysis and comparison of large data sets.

59 BASIC BIOLOGICAL SCIENCES↗

In situ and operando force-based atomic force microscopy for probing local functionality in energy storage materials

Electrochemical energy storage is the key enabling component of electric vehicles and solar-/wind-based energy technologies. The enhancement of energy stored requires the detailed understanding of charge storage mechanisms and local electrochemical and electromechanical phenomena over a variety of length scales from atoms to full cells. Classical electrochemical techniques, such as voltammetry, represent the macroscopic electrochemical properties, and consequently do not allow to extract important information about local electrochemical reactions, ions adsorption, intercalations, and transport. Understanding, controlling, and tuning the local electrochemical functionalities in functional energy materials require in situ/operando techniques which limit the use of structural and functional characterization techniques that provide local information. Here, force-based atomic force microscopies (AFMs) have provided novel insights into locally probing electrochemical mechanisms on tens of nanometer and even molecular length scales and provide a viable pathway to probe electrochemical processes in situ/operando. In this review, we highlight the contributions in the development and application of force-based AFM methods to elucidate the local charge storage mechanism in a variety of energy-related materials. We will focus in particular on methods or AFM modalities in a liquid electrolyte environment.

25 ENERGY STORAGE↗

Hydrothermal atomic force microscopy observations of barite step growth rates as a function of the aqueous barium-to-sulfate ratio

The rate of growth of ionic minerals from solutions with varying aqueous cation:anion ratios may result in significant errors in mineralization rates predicted by commonly-used affinity-based rate equations. To assess the potential influence of solute stoichiometry on barite growth, step velocities on the barite (001) surface have been measured at 108 °C using hydrothermal atomic force microscopy (HAFM) at moderate supersaturation and as a function of the aqueous barium:sulfate ratio (r). Barite growth hillocks at r ~ 1 were bounded by $\langle$120$\rangle$ steps, however at r < 1, kink site densities increased, steps followed a direction vicinal to $\langle$120$\rangle$, and the [010] steps developed. At r > 1, steps roughened and rounded as the kink site density increased. Step velocities peaked at r = 1 and decreased roughly symmetrically as a function of r, indicating the attachment rates of barium and sulfate ions are similar under these conditions. We hypothesize that the differences in our observations at high and low r arise from differences in the attachment rate constants for the obtuse and acute $\langle$120$\rangle$ steps. Based on results at low r, the data suggests the attachment rate constant for barium ions is similar for obtuse and acute steps. Based on results at high r, the data suggests the attachment rate constant for sulfate is greater for obtuse steps than acute steps. In conclusion, utilizing a step growth model developed by Stack and Grantham (2010) the experimental step velocities as a function of r were readily fit while attempts to fit the data using a model developed by Zhang and Nancollas (1998) were less successful.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical and Atomic Force Microscopy Characterization of PbI2 Quantum Dots

Lead iodide (PbI2) clusters were synthesized from the chemical reaction of NaI (or KI) with Pb(NO3)2 in H2O, D2O, CH3OH, and C3H7OH media. The observation of the absorption features above 350 nm with the help of integrating sphere accessory strongly suggests the quantum dot formation of PbI2 in solution. Spectral comparison between the synthesized PbI2 clusters in solution and PbI2 nanophase by impregnation of PbI2 in four different pore-sized porous silica indicates that the PbI2 cluster size in solution is less than 2.5 nm in lateral dimension. Atomic force microscopy (AFM) measurements show that the PbL clusters deposited onto three different molecularly flat surfaces are single-layered. The measured height is 1.0 - 0.1 nm. The swollen layer thickness can be attributed to the intralayer contraction from the strong lateral interaction among PbI2 molecules, which is supported by ab initio calculation. Raman scattering measurement of LO and TO modes of PbI2 in bulk and in the confined state were also conducted in 50-150 cu cm region. The observed three bands at 74, %, 106 1/cm are assigned to TO2, LO2, and LO, mode, respectively. The relatively small red-shift in LO modes may be caused by the surface phonon polaritons of PbI2 nanophase in the porous silica.

Mu, R.↗

Photocatalytic Degradation of Bacteriophages Evidenced by Atomic Force Microscopy

Methods to supply fresh water are becoming increasingly critical as the world population continues to grow. Small-diameter hazardous microbes such as viruses (20–100 nm diameter) can be filtered by size exclusion, but in this approach the filters are fouled. Thus, in our research, we are investigating an approach in which filters will be reusable. When exposed to ultraviolet (UV) illumination, titanate materials photocatalytically evolve N OH and O2N2 radicals, which attack biological materials. In the proposed approach, titanate nanosheets are deposited on a substrate. Viruses adsorb on these nanosheets and degrade when exposed to UV light. Using atomic force microscopy (AFM), we image adsorbed viruses and demonstrate that they are removed by UV illumination in the presence of the nanosheets, but not in their absence.

59 BASIC BIOLOGICAL SCIENCES↗

Au Colloids Formed by Ion Implantation in Muscovite Mica Studied by Vibrational and Electronic Spectroscopes and Atomic Force Microscopy

Au was implanted into the (001) surface of Muscovite mica at an energy of 1.1 MeV and at doses of 1, 3, 6, and 10 x 10(exp 16) ions/cu cm. Optical spectra of the as-implanted samples revealed a peak at 2.28 eV (545 nm) which is attributed to the surface plasmon absorption of Au colloids. The infrared reflectance measurements show a decreasing reflectivity with increasing ion dose in the Si-O stretching region (900-1200 /cm). A new peak observed at 967 /cm increases with the ion dose and is assigned to an Si-O dangling bond. Atomic force microscopy images of freshly cleaved samples implanted with 6 and 10 x 10(exp 16) ions/sq cm indicated metal colloids with diameters between 0.9- 1.5 nm. AFM images of the annealed samples showed irregularly shaped structures with a topology that results from the fusion of smaller colloids.

Tung, Y. S.↗

Tuning Metastability of Poly(3-hexyl thiophene) Solutions to Enable in Situ Atomic Force Microscopy Imaging of Surface Nucleation

Poly(3-hexyl thiophene) (P3HT), a workhorse material for the study of organic electronic devices, assembles into nanofibers (NFs) upon crystallization from solution, providing the means to tailor morphology and improve device performance. We investigate how P3HT regioregularity, molecular weight, and concentration influence the hysteresis between crystallization and melting temperatures of NFs. Hysteresis is found to increase with molecular weight and reach an asymptote for polymer chains above the chain folding threshold (Mn > 12 kg/mol). Regioregularity does not substantially affect the hysteresis above a level of 88%, while increasing polymer concentration is found to reduce hysteresis. This insight facilitates in situ high-resolution atomic force microscopy measurements that provide better understanding of the mechanism of NF crystallization on graphite. We find an interchain distance (along the a crystallographic axis) of 16.7 ± 0.7 Å, and a spacing of 7.7 ± 0.2 Å along the c axis, suggesting that the crystals on graphite are form I.

36 MATERIALS SCIENCE↗

Atomic Force Microscopy to Characterize Antimicrobial Peptide-Induced Defects in Model Supported Lipid Bilayers

Antimicrobial peptides (AMPs) interact with bacterial cell membranes through a variety of mechanisms, causing changes extending from nanopore formation to microscale membrane lysis, eventually leading to cell death. Several AMPs also disrupt mammalian cell membranes, despite their significantly different lipid composition and such collateral hemolytic damage hinders the potential therapeutic applicability of the AMP as an anti-microbial. Elucidating the mechanisms underlying the AMP–membrane interactions is challenging due to the variations in the chemical and structural features of the AMPs, the complex compositional variations of cell membranes and the inadequacy of any single experimental technique to comprehensively probe them. (1) Background: Atomic Force Microscopy (AFM) imaging can be used in combination with other techniques to help understand how AMPs alter the orientation and structural organization of the molecules within cell membranes exposed to AMPs. The structure, size, net charge, hydrophobicity and amphipathicity of the AMPs affect how they interact with cell membranes of differing lipid compositions. (2) Methods: Our study examined two different types of AMPs, a 20-amino acid, neutral, α-helical (amphipathic) peptide, alamethicin, and a 13-amino acid, non-α-helical cationic peptide, indolicidin (which intramolecularly folds, creating a hydrophobic core), for their interactions with supported lipid bilayers (SLBs). Robust SLB model membranes on quartz supports, incorporating predominantly anionic lipids representative of bacterial cells, are currently not available and remain to be developed. Therefore, the SLBs of zwitterionic egg phosphatidylcholine (PC), which represents the composition of a mammalian cell membrane, was utilized as the model membrane. This also allows for a comparison with the results obtained from the Quartz Crystal Microbalance with Dissipation (QCM-D) experiments conducted for these peptides interacting with the same zwitterionic SLBs. Further, in the case of alamethicin, because of its neutrality, the lipid charge may be less relevant for understanding its membrane interactions. (3) Results: Using AFM imaging and roughness analysis, we found that alamethicin produced large, unstable defects in the membrane at 5 µM concentrations, and completely removed the bilayer at 10 µM. Indolicidin produced smaller holes in the bilayer at 5 and 10 µM, although they were able to fill in over time. The root-mean-square (RMS) roughness values for the images showed that the surface roughness caused by visible defects peaked after peptide injection and gradually decreased over time. (4) Conclusions: AFM is useful for helping to uncover the dynamic interactions between different AMPs and cell membranes, which can facilitate the selection and design of more efficient AMPs for use in therapeutics and antimicrobial applications.

Swana, Kathleen W.↗