An Approach to Reliability Testing of Microcircuits at Cryogenic Conditions

This viewgraph presentation reviews an approach to testing microcircuits at cryogenic temperatures. Standard testing procedures are not adequate to test microcircuits that are to operate at cryogenic temperatures. It is therefore necessary to perform analysis of operation conditions and reliability conditions for planning qualification testing of microcircuits at cryogenic temperatures. The major degradations for microcircuits operating at low temperatures depend on the number of switching cycles rather than on the duration of part operation. Therefore instead of accelerating degradation of the parts by increasing the level of stress, the possibility of which is very limited at cryogenic temperatures, the reliability testing can be based on the number of switching cycles.

Teverovsky, Alexander↗

Assessing photovoltaic module life from long-term environmental tests

An assessment is made of results obtained by an experimental program having as its aim the identification of critical temperature-humidity bias degradation mechanisms in solar cell modules intended to have an operating lifetime of the order of 20-30 years. These mechanisms are studied in the context of conditions encountered over the course of long term operation in various sites in the U.S. Accelerated tests for the assessment of product lifetime entail the development of a correlation between test and application conditions; this has been accomplished through an analytical procedure for the correlation of time-varying field exposures to constant-stress accelerated environments.

Otth, D. H.↗

Parametric Failures in COTS Capacitors

Insertion of COTS components into hi-rel systems require extensive environmental testing of the parts that often results in parametric failures. Based on experience with commercial and hi-rel PME and BME ceramic capacitors and polymer and MnO2 cathode tantalum capacitors, this presentation discusses two major reasons for parametric failures. One is due to the marketing pressure that forces manufacturers to squeeze performance of COTS components thus leaving insufficient margin between the rated and actual characteristics. Another, and probably a more serious reason is degradation of characteristics caused by physico-chemical processes in materials under environmental stresses. Reliability assessment requires development of models to predict behavior of the parts during applications based on accelerated testing that might be outside the specified conditions and target applications. Examples of models developed to simulate and predict wear-out failures are presented. Risks associated with overstressing during HALT are discussed.

Teverovsky, Alexander↗

Transducer applications, a compilation

The characteristics and applications of transducers are discussed. Subjects presented are: (1) thermal measurements, (2) liquid level and fluid flow measurements, (3) pressure transducers, (4) stress-strain measurements, (5) acceleration and velocity measurements, (6) displacement and angular rotation, and (7) transducer test and calibration methods.

Source record↗

Structural Benchmark Testing for Stirling Convertor Heater Heads

The National Aeronautics and Space Administration (NASA) has identified high efficiency Stirling technology for potential use on long duration Space Science missions such as Mars rovers, deep space missions, and lunar applications. For the long life times required, a structurally significant design limit for the Stirling convertor heater head is creep deformation induced even under relatively low stress levels at high material temperatures. Conventional investigations of creep behavior adequately rely on experimental results from uniaxial creep specimens, and much creep data is available for the proposed Inconel-718 (IN-718) and MarM-247 nickel-based superalloy materials of construction. However, very little experimental creep information is available that directly applies to the atypical thin walls, the specific microstructures, and the low stress levels. In addition, the geometry and loading conditions apply multiaxial stress states on the heater head components, far from the conditions of uniaxial testing. For these reasons, experimental benchmark testing is underway to aid in accurately assessing the durability of Stirling heater heads. The investigation supplements uniaxial creep testing with pneumatic testing of heater head test articles at elevated temperatures and with stress levels ranging from one to seven times design stresses. This paper presents experimental methods, results, post-test microstructural analyses, and conclusions for both accelerated and non-accelerated tests. The Stirling projects use the results to calibrate deterministic and probabilistic analytical creep models of the heater heads to predict their life times.

Krause, David L.↗

Effects Of Pyrotechnically Generated Shocks

Research program provides better understanding of pyrotechnic phenomenon for design purposes. Evaluating potential for damage to spacecraft by activation of pyrotechnic mechanisms, pyrotechnic-shock tests conducted on three configurations: pin pullers on orthogonal double Hopkinson bar arrangement; pin pullers on mockup of Halogen Occultation Experiment (HALOE) structure; and section of separation joint on single Hopkinson bar. Strains and accelerations measured. Strains converted to output stresses, forces, and moments. Acceleration shock-response spectra obtained for both acceleration and force signals. Results of research useful to designers in making comparison and evaluation tests before committing to costly spacecraft hardware.

Bement, Laurence J.↗

Failure Modes in Capacitors When Tested Under a Time-Varying Stress

Power-on failure has been the prevalent failure mechanism for solid tantalum capacitors in decoupling applications. A surge step stress test (SSST) has been previously applied to identify the critical stress level of a capacitor batch to give some predictability to the power-on failure mechanism [1]. But SSST can also be viewed as an electrically destructive test under a time-varying stress (voltage). It consists of rapidly charging the capacitor with incremental voltage increases, through a low resistance in series, until the capacitor under test is electrically shorted. When the reliability of capacitors is evaluated, a highly accelerated life test (HALT) is usually adopted since it is a time-efficient method of determining the failure mechanism; however, a destructive test under a time-varying stress such as SSST is even more time efficient. It usually takes days or weeks to complete a HALT test, but it only takes minutes for a time-varying stress test to produce failures. The advantage of incorporating a specific time-varying stress profile into a statistical model is significant in providing an alternative life test method for quickly revealing the failure mechanism in capacitors. In this paper, a time-varying stress that mimics a typical SSST has been incorporated into the Weibull model to characterize the failure mechanism in different types of capacitors. The SSST circuit and transient conditions for correctly surge testing capacitors are discussed. Finally, the SSST was applied for testing Ta capacitors, polymer aluminum capacitors (PA capacitors), and multi-layer ceramic (MLC) capacitors with both precious metal electrodes (PME) and base metal electrodes (BME). The test results are found to be directly associated with the dielectric layer breakdown in Ta and PA capacitors and are independent of the capacitor values, the way the capacitors were built, and the capacitors manufacturers. The test results also show that MLC capacitors exhibit surge breakdown voltages much higher than the rated voltage and that the breakdown field is inversely proportional to the dielectric layer thickness. The SSST data can also be used to comparatively evaluate the voltage robustness of capacitors for decoupling applications.

Liu, David (Donhang)↗

Investigation of accelerated stress factors and failure/degradation mechanisms in terrestrial solar cells

Results of an ongoing research program into the reliability of terrestrial solar cells are presented. Laboratory accelerated testing procedures are used to identify failure/degradation modes which are then related to basic physical, chemical, and metallurgical phenomena. In the most recent tests, ten different types of production cells, both with and without encapsulation, from eight different manufacturers were subjected to a variety of accelerated tests. Results indicated the presence of a number of hitherto undetected failure mechanisms, including Schottky barrier formation at back contacts and loss of adhesion of grid metallization. The mechanism of Schottky barrier formation is explained by hydrogen, formed by the dissociation of water molecules at the contact surface, diffusing to the metal semiconductor interface. This same mechanism accounts for the surprising increase in sensitivity to accelerated stress conditions that was observed in some cells when encapsulated.

Lathrop, J. W.↗

Influence of High Cycle Thermal Loads on Thermal Fatigue Behavior of Thick Thermal Barrier Coatings

Thick thermal barrier coating systems in a diesel engine experience severe thermal Low Cycle Fatigue (LCF) and High Cycle Fatigue (HCF) during engine operation. In the present study, the mechanisms of fatigue crack initiation and propagation, as well as of coating failure, under thermal loads which simulate engine conditions, are investigated using a high power CO2 laser. In general, surface vertical cracks initiate early and grow continuously under LCF and HCF cyclic stresses. It is found that in the absence of interfacial oxidation, the failure associated with LCF is closely related to coating sintering and creep at high temperatures, which induce tensile stresses in the coating after cooling. Experiments show that the HCF cycles are very damaging to the coating systems. The combined LCF and HCF tests produced more severe coating surface cracking, microspallation and accelerated crack growth, as compared to the pure LCF test. It is suggested that the HCF component cannot only accelerate the surface crack initiation, but also interact with the LCF by contributing to the crack growth at high temperatures. The increased LCF stress intensity at the crack tip due to the HCF component enhances the subsequent LCF crack growth. Conversely, since a faster HCF crack growth rate will be expected with lower effective compressive stresses in the coating, the LCF cycles also facilitate the HCF crack growth at high temperatures by stress relaxation process. A surface wedging model has been proposed to account for the HCF crack growth in the coating system. This mechanism predicts that HCF damage effect increases with increasing temperature swing, the thermal expansion coefficient and the elastic modulus of the ceramic coating, as well as the HCF interacting depth. A good agreement has been found between the analysis and experimental evidence.

Zhu, Dongming↗

Benchmark Calibration Tests Completed for Stirling Convertor Heater Head Life Assessment

A major phase of benchmark testing has been completed at the NASA Glenn Research Center (http://www.nasa.gov/glenn/), where a critical component of the Stirling Radioisotope Generator (SRG) is undergoing extensive experimentation to aid the development of an analytical life-prediction methodology. Two special-purpose test rigs subjected SRG heater-head pressure-vessel test articles to accelerated creep conditions, using the standard design temperatures to stay within the wall material s operating creep-response regime, but increasing wall stresses up to 7 times over the design point. This resulted in well-controlled "ballooning" of the heater-head hot end. The test plan was developed to provide critical input to analytical parameters in a reasonable period of time.

Krause, David L.↗

Effects of Altered Gravity on the Central Nervous System of Drosophila melanogaster

A comprehensive understanding of the effects of spaceflight and altered gravity on human physiology is necessary for continued human space exploration and long-term space habitation. Spaceflight includes multiple factors such as microgravity, hypergravity, ionizing radiation, physiological stress, and disrupted circadian rhythms and these have been shown to contribute to pathophysiological responses that target immunity, bone and muscle integrity, cardiovascular and nervous systems. In terrestrial conditions, some of these factors can lead to cancer and neuroimmunological disorders. In this study, we used a well-established spaceflight model organism, Drosophila melanogaster, to assess spaceflight-associated changes in the nervous system. We hypothesize that exposure to altered gravity triggers the oxidative stress response, leading to impairments in the nervous system. To test this hypothesis, we used two experimental paradigms: 1) hypergravity, using the ground-based chronic acceleration model, and 2) spaceflight conditions, which includes exposure to microgravity and in-flight space 1g controls. In our ground studies, acute hypergravity resulted in an induction of oxidative stress-related genes with an increase in reactive oxygen species (ROS) in fly brains. Additionally, we observed a depressed locomotor phenotype in these flies (p<0.05). These flies also show a decreased dopaminergic neuron counts in the fly brain upon exposure to acute hypergravity (p<0.05). Thus, the data suggest that altered gravity has a profound effect on the fly nervous system. Similarly, we observe behavioral impairments (p<0.001) and synaptic deficits, including decreased synaptic connections (p<0.05), in 3rd instar larvae which were developed in space. Furthermore, space-grown adults show a decrease in neuronal (p<0.05) and dendritic field (p<0.01) in adult brains coupled with an increased number of apoptotic cells (p<0.001), suggesting increased neuronal loss under spaceflight conditions. In summary, we observe that altered gravity leads to gross neurological deficits. To better understand the long-term effects of spaceflight on the nervous system, longitudinal and multigenerational changes were also identified. This study will help elucidate the different approaches to prevent nervous system dysfunction in astronauts during spaceflight, while also contributing to a better understanding of the pathways that are related to some CNS disorders on Earth.

nervous system↗

Electric Plasma Arc-Lamp Combustor Liner Durability Test System Developed

Silicon carbide matrix composites are candidate materials for high-temperature combustor liners. Because through-the-thickness thermal gradients are the primary cause of stress on combustor liners, a unique test facility was developed at the NASA Glenn Research Center at Lewis Field to simulate in-service pure thermal stress distributions in fiber reinforced silicon carbide cylinders. It was developed initially under Phase II of the High- Speed Research Program. This test stand can accommodate 8-in.-long test cylinders that have outer diameters of 4 in. and a wall thickness of about 0.08 to 0.12 in. One cylinder at a time is loaded vertically into the test stand. Water-cooled plates enclose the open ends of the cylinder and provide cooling. Load plates on the exterior side of the water-cooled plates provide support and compression loads. To evaluate a combustor liner material s potential performance, researchers induce thermal gradients with an axisymmetric, direct-current, electric arc within the cylinder while refrigerated air at a rate of 1.5 lb/sec impinges on the outside surface of the cylinder. The achievable through-the-thickness thermal gradient is predicted to be in excess of 200 C. The 8-in. long, 0.5-in.-diameter plasma arc emits full spectrum visible light; radiant intensity exceeds 300 Watts per square centimeters to produce temperatures in excess of 1500 C on materials with emissivity near unity. Because the system does not rely upon the combustion of fuels to achieve the related thermal conditions, ancillary environmental reactions with the sample are eliminated. The system incorporates a standard mechanical test frame, which can impose constant as well cyclical axial stresses up to 2200 lb upon the test piece. Silicon-carbide-fiber reinforced silicon carbide matrix composite cylinders were instrumented with thin-film thermocouples to obtain through-the-thickness thermal flux measurements. Inside wall temperatures reached 1200 C with only 250 A of current. One of the special features of this configuration is the creation of hoop stress states within the cylinder, which up this point have not been obtainable in planar coupon tests. This facility will allow various operational modes, including accelerated tests of thermal transients simulating the effects of repeated engine ignition as well as prescribed thermal and mechanical histories to simulate various duty cycle profiles. Tests can now be performed on thermal-barrier-coated metallic liners and ceramic composite liners that require a combination of high heat flux and controlled mechanical stresses.

Goldsby, Jon C.↗

Effect of KOH concentration on LEO cycle life of IPV nickel-hydrogen flight cells-update 2

An update of validation test results confirming the breakthrough in low earth orbit (LEO) cycle life of nickel-hydrogen cells containing 26 percent KOH electrolyte is presented. A breakthrough in the LEO cycle life of individual pressure vessel (IPV nickel-hydrogen cells has been previously reported. The cycle life of boiler plate cells containing 26 percent potassium hydroxide (KOH) electrolyte was about 40 000 LEO cycles compared to 3500 cycles for cells containing 31 percent KOH. This test was conducted at Hughes Aircraft Company under a NASA Lewis contract. The purpose was to investigate the effect of KOH concentration on cycle life. The cycle regime was a stressful accelerated LEO, which consisted of a 27.5 min charge followed by a 17.5 min discharge (2x normal rate). The depth of discharge (DOD) was 80 percent. The cell temperature was maintained at 23 C. The boiler plate test results are in the process of being validated using flight hardware and real time LEO test at the Naval Weapons Support Center (NWSC), Crane, Indiana under a NASA Lewis Contract. Six 48 Ah Hughes recirculation design IPV nickel-hydrogen flight battery cells are being evaluated. Three of the cells contain 26 percent KOH (test cells), and three contain 31 percent KOH (control cells). They are undergoing real time LEO cycle life testing. The cycle regime is a 90-min LEO orbit consisting of a 54-min charge followed by a 36-min discharge. The depth-of-discharge is 80 percent. The cell temperature is maintained at 10 C. The three 31 percent KOH cells failed (cycles 3729, 4165, and 11355). One of the 26 percent KOH cells failed at cycle 15314. The other two 26 percent KOH cells were cycled for over 16600 cycles during the continuing test.

Smithrick, John J.↗

Towards linking lab and field lifetimes of perovskite solar cells

Metal halide perovskite solar cells (PSCs) represent a promising low-cost, thin-film photovoltaic (PV) technology, with unprecedented power conversion efficiencies (PCEs) obtained for both single-junction and tandem applications. To push PSCs toward commercialization, it is critical, albeit challenging, to understand device reliability under real-world outdoor conditions where multiple stress factors (e.g., light, heat, humidity) coexist, generating complicated degradation behaviors. It is necessary to identify accelerated indoor testing protocols - which can correlate specific stressors with observed degradation modes in fielded devices - to quickly guide PSC development. Here, we use a state-of-the-art p-i-n PSC stack (with PCE up to ~25.5%) to show that indoor accelerated stability tests can predict our 6-month outdoor aging tests. Device degradation rates under illumination and at elevated temperatures are most instructive for understanding outdoor device reliability. Further, we also find that the indium tin oxide (ITO)/self-assembled monolayer (SAM)-based hole transport layer (HTL)/perovskite interface most strongly affects our device operation stability. Improving the ion-blocking properties of the SAM HTL increases averaged device operational stability at 50 degree C-85 °C by a factor of ~2.8, reaching over 1000 h at 85 °C and to near 8200 h at 50 °C with a projected 20% degradation, which is among the best to date for high-efficiency p-i-n PSCs.

14 SOLAR ENERGY↗

Useful Life of Tantalum Capacitors

Currently, the major reliability characteristic of tantalum capacitors is the failure rate, which is a constant used to characterize random failures of electronic components. However, contemporary MnO2 and polymer tantalum capacitors have both infant mortality (IM) and wear-out (WO) failures. This requires assessments of the useful life of the parts that is limited by the time of inception of WO failures that can be determined using an adequate reliability model and results of highly accelerated life testing (HALT). In this presentation, a modified time dependent dielectric breakdown (TDDB) model is used to describe both IM and WO failures during HALT. Specifics of physical processes resulting in degradation and failures in polymer and MnO2 tantalum capacitors are discussed, and the increase of IM failures with the level of stress is explained. The model justifies exponential dependence of the acceleration factors on voltage and predicts higher values of the voltage acceleration constant for IM compared to WO failures.

tantalum capacitors↗

Evaluation of Case Size 0603 BME Ceramic Capacitors

High volumetric efficiency of commercial base metal electrode (BME) ceramic capacitors allows for a substantial reduction of weight and sizes of the parts compared to currently used military grade precious metal electrode (PME) capacitors. Insertion of BME capacitors in space applications requires a thorough analysis of their performance and reliability. In this work, six types of cases size 0603 BME capacitors from three vendors have been evaluated. Three types of multilayer ceramic capacitors (MLCCs) were designed for automotive industry and three types for general purposes. Leakage currents in the capacitors have been measured in a wide range of voltages and temperatures, and measurements of breakdown voltages (VBR) have been used to assess the proportion and severity of defects in the parts. The effect of soldering-related thermal shock stresses was evaluated by analysis of distributions of VBR for parts in 'as is' condition and after terminal solder dip testing at 350 C. Highly Accelerated Life Testing (HALT) at different temperatures was used to assess the activation energy of degradation of leakage currents and predict behavior of the parts at life test and normal operating conditions. To address issues related to rework and manual soldering, capacitors were soldered onto different substrates at different soldering conditions. The results show that contrary to a common assumption that large-size capacitors are mostly vulnerable to soldering stresses, cracking in small size capacitors does happen unless special measures are taken during assembly processes.

testing↗

Testing of Helium-Cooled Metal Molybdenum Disk Target

NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

36 MATERIALS SCIENCE↗