Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Aberration correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A solution to the problem of SAR range curvature

When synthetic aperture radar systems are pushed to attain finer resolution at larger ranges than was previously the case for remote sensing purposes, the geometric signal aberration known as range curvature arises. Known techniques for correcting range curvature are exact at only one selected range, thus forcing neighboring ranges to use the same correction as an approximation. A solution to the problem is proposed that is exact at all ranges, thus simplifying and improving the image processing for such systems.

Raney, R. K.↗

Development of the Optical Communications Telescope Laboratory: A Laser Communications Relay Demonstration Ground Station

The Laser Communications Relay Demonstration (LCRD) project will demonstrate high bandwidth space to ground bi-directional optical communications links between a geosynchronous satellite and two LCRD optical ground stations located in the southwestern United States. The project plans to operate for two years with a possible extension to five. Objectives of the demonstration include the development of operational strategies to prototype optical link and relay services for the next generation tracking and data relay satellites. Key technologies to be demonstrated include adaptive optics to correct for clear air turbulence-induced wave front aberrations on the downlink, and advanced networking concepts for assured and automated data delivery. Expanded link availability will be demonstrated by supporting operations at small sun-Earth-probe angles. Planned optical modulation formats support future concepts of near-Earth satellite user services to a maximum of 1.244 Gb/s differential phase shift keying modulation and pulse position modulations formats for deep space links at data rates up to 311 Mb/s. Atmospheric monitoring instruments that will characterize the optical channel during the link include a sun photometer to measure atmospheric transmittance, a solar scintillometer, and a cloud camera to measure the line of sight cloud cover. This paper describes the planned development of the JPL optical ground station.

optical commuication↗

Nonlinear integrable optics beam dynamics experiment and diagnostics

All present circular particle accelerators are built around linear focusing optics. Un-avoidable nonlinear elements appear in accelerators, such as magnetic aberrations and space-charge effects, which are typically corrected using nonlinear magnets. However, these added nonlinearities degrade particle beam stability, and in most cases, the system becomes non-integrable. The Integrable Optics Test Accelerator (IOTA), at Fermi National Accelerator Laboratory (Fermilab), is a test bed to study beam dynamics in integrable lattices for both electron and proton beams, independently. This work presents experimental results of the nonlinear electron beam dynamics behavior in IOTA using an elliptical nonlinear magnet. The elliptical nonlinear magnet allows for a large betatron tune spread, allowing for a stable high-intensity beam. In a future experimental run, minimally invasive beam instrumentation is needed to study time-dependent collective instabilities, and halo formation in space-chargedominated proton beams. Traditional profile monitors are too destructive to the beam or just measure one dimension of the beam. A gas sheet can be injected perpendicular to theproton beam at an angle. By doing so, a two-dimensional, turn-by-turn, transverse profile measurement can be made, which will preserve the integrity of the beam. The developmentand progress of a gas sheet beam profile monitor will also be presented.

43 PARTICLE ACCELERATORS↗

Three-Dimensional Single-Molecule Localization Microscopy in Whole-Cell and Tissue Specimens

Super-resolution microscopy techniques are versatile and powerful tools for visualizing organelle structures, interactions, and protein functions in biomedical research. However, whole-cell and tissue specimens challenge the achievable resolution and depth of nanoscopy methods. We focus on three-dimensional single-molecule localization microscopy and review some of the major roadblocks and developing solutions to resolving thick volumes of cells and tissues at the nanoscale in three dimensions. These challenges include background fluorescence, system- and sample-induced aberrations, and information carried by photons, as well as drift correction, volume reconstruction, and photobleaching mitigation. We also highlight examples of innovations that have demonstrated significant breakthroughs in addressing the abovementioned challenges together with their core concepts as well as their trade-offs.

59 BASIC BIOLOGICAL SCIENCES↗

Summary of flight performance of the Skylab Earth Resources Experiment Package /EREP/

A group of six remote sensor systems (sensing visible, infrared, and microwave radiation) known as the Earth Resources Experiment Package (EREP) was flown on the NASA Skylab spacecraft to furnish data to numerous investigators in the earth sciences and in technology assessment. Inflight sensor performance in three categories (functional, geometric, and radiometric) was evaluated using: (1) ground measurements of surface, atmospheric, and illumination parameters; (2) ground deployment and operation of microwave receivers and transponders to monitor and excite the active EREP sensors; (3) measurement of surface and atmospheric parameters by instrumented aircraft on underflights of Skylab passes; and (4) analysis of the actual flight data. This resulted in identification and correction of anomalous sensor operation, quantization of geometric distortions or aberrations, improvement or confirmation of calibrations, and determination of sensitivity, accuracy, and stability of the sensors.

Potter, A. E.↗

Observations of 3C 273 with the Goddard High Resolution Spectrograph on the Hubble Space Telescope

The observations of the quasar 3C 273 taken with the Goddard High Resolution Spectrograph in 1991 February are presented here. We have included both the reduced raw data, and smoothed and deconvolved spectra. Also, a list of observed absorption lines is presented. The data comprise 11 spectra, including one low resolution and 10 medium resolution observations. The wavelength region covered ranged from about 1150 to 2820 A, but was not all inclusive. The procedures used to obtain and reduce the data, including corrections for fixed pattern noise, compensation for the effects of spherical aberration in the HST primary mirror, and objective detection of weak absorption lines, are described. We also have included a short discussion on the detection of galactic Ni II and Virgo cluster metal lines.

Brandt, J. C.↗

Corrective Optics For Camera On Telescope

Assembly of tilted, aspherical circularly symmetric mirrors used as corrective optical subsystem for camera mounted on telescope exhibiting both large spherical wave-front error and inherent off-axis astigmatism. Subsystem provides unobscured camera aperture and diffraction-limited camera performance, despite large telescope aberrations. Generic configuration applied in other optical systems in which aberations deliberately introduced into telescopes and corrected in associated cameras. Concept of corrective optical subsystem provides designer with additional degrees of freedom used to optimize optical system.

Macenka, Steven A.↗

Nominal SARAL Transfer Function

This paper gives a calculation of the range correction and cross section of the SARAL (Satellite with Argos and ALtiKa) Indian/French ocean radar satellite retroreflector array assuming the cube corners are coated and have a dihedral angle offset of about 1.5 arcseconds to account for velocity aberration. The cubes are assumed to all have the same orientation within the mounting. The derived range correction may be applied in precise orbit determination analyses that use Satellite Laser Ranging (SLR) data to SARAL.

Precise orbit determination↗

Nominal SARAL Transfer Function

This paper gives a calculation of the range correction and cross section of the SARAL (Satellite with Argos and ALtiKa) Indian/French ocean radar satellite retroreflector array assuming the cube corners are coated and have a dihedral angle offset of about 1.5 arcseconds to account for velocity aberration. The cubes are assumed to all have the same orientation within the mounting. The derived range correction may be applied in precise orbit determination analyses that use Satellite Laser Ranging (SLR) data to SARAL.

SARAL↗

Tunable-Bandwidth Filter System

A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS, was shown to be capable of spectral sampling of images in the visible range over a 200 nm spectral range with a spectral resolution of 30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

Bailey, John W.↗

Tunable-Bandwidth Filter System

A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote-sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS was shown to be capable of spectral sampling of images in the visible range over a 200-nm spectral range with a spectral resolution of .30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of the lenses are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light to a field stop that is also a focal point of each spherical lens. A correcting lens in front of the field stop compensates for the spherical aberration of the spherical lenses. The front surface of each spherical lens collimates the light coming from the field stop. After the collimated light passes through the filter in the spherical lens, the rear surface of the lens focuses the light onto a charge-coupled-device image detector.

Aye, Tin↗

Real-Time Holographic Image Correction Using Bacteriorhodopsin

We present experimental results of one-way coherent imaging through a thin phase-aberrating medium using a holographic technique with bacteriorhodopsin as a real-time holographic material. Bacteriorhodopsin is well suited for the application when the aberration is time varying because of its real-time writing and erasing characteristics, sensitivity, and spatial resolution. We show results with final image resolution of greater than 20 line pairs/mm and high signal-to-noise ratio using a polarization-holography approach.

Downie, John D.↗

Offset guiding through large space telescopes.

Discussion of the merits of various space telescope system designs, both of the Ritchey-Chretien and Gregorian kinds. In particular design data for an f/2.2 to f/12.0 Ritchey-Chretien system with a five-element telecentric field corrector and for another f/3.3 to f/15.0 similar system with a two-cylindrical-element telecentric field corrector are reviewed, along with data for an f/2.5 to f/15.0 Ritchey-Chretien system with a fold mirror corrector and for an f/2.2 to f/12.0 coma-corrected Gregorian system with a five-element telecentric field corrector. The transverse aberrations, optical path differences, and other characteristics of these system design varieties are examined.-

Schulte, D. H.↗

Refractive field correctors for the Starlab ultraviolet telescope

Field correctors for a one-meter, f/15 cassegrainian telescope were designed as part of a NASA-funded study of an astronomical obervatory on board of the Space Shuttle. By means of a Gasgoigne corrector and a biconcave field flattener, astigmatism and field curvature are corrected in a 0.6 deg field. Applicable wavelength ranges are limited by chromatic aberrations. The upper wavelength is selected to match a photocathode response limit. The lower wavelength limit is defined by a filter. Examples of usable wavelength ranges are: 210 nm - 1100 nm (multialkali photocathode, fused-silica corrector elements), 177 nm - 320 nm (cesium telluride photocathode, calcium fluoride correctors); and possibly 134 nm - 190 nm (cesium iodide photocathode, lithium fluoride correctors). Residual rms lateral color is smaller than 0.02 arc sec, and axial color is smaller than 0.25 arc sec (blur diameter at the ends of the wavelength range). The correctors introduce a small amount of coma. This is compensated by adjustment of the conic constants of the telescope mirrors.

Bottema, M.↗

Suppression of Speckles at High Adaptive Correction Using Speckle Symmetry

Focal-plane speckles set important sensitivity limits on ground- or space-based imagers and coronagraphs that may be used to search for faint companions, perhaps ultimately including exoplanets, around stars. As speckles vary with atmospheric fluctuations or with drifting beamtrain aberrations, they contribute speckle noise proportional to their full amplitude. Schemes to suppress speckles are thus of great interest. At high adaptive correction, speckles organize into species, represented by algebraic terms in the expansion of the phase exponential, that have distinct spatial symmetry, even or odd, under spatial inversion. Filtering speckle patterns by symmetry may eliminate a disproportionate fraction of the speckle noise while blocking (only) half of the image signal from the off-axis companion being sought. The fraction of speckle power and hence of speckle noise in each term will vary with degree of correction, and so also will the net symmetry in the speckle pattern.

atmospheric turbulence↗

Laboratory and On-Sky Validation of the Shaped Pupil Coronagraph's Sensitivity to Low-Order Aberrations with Active Wavefront Control

We present early laboratory simulations and extensive on-sky tests validating of the performance of a shaped pupil coronagraph (SPC) behind an extreme-AO (Adaptive Optics) corrected beam of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) system. In tests with the SCExAO internal source/wavefront error simulator, the normalized intensity profile for the SPC degrades more slowly than for the Lyot coronagraph as low-order aberrations reduce the Strehl ratio (S.R.) from extremely high values (S.R. approximately 0.93-0.99) to those characteristic of current ground-based extreme AO systems (S.R. approximately 0.74-0.93) and then slightly lower values down to S.R. approximately 0.57. On-sky SCExAO data taken with the SPC and other coronagraphs for brown dwarf/planet-hosting stars HD 1160 and HR 8799 provide further evidence for the SPC's robustness to low-order aberrations. From H-band Strehl ratios of 80 percent to 70 percent, the Lyot coronagraph's performance versus that of the SPC may degrade even faster on sky than is seen in our internal source simulations. The 5-sigma contrast also degrades faster (by a factor of two) for the Lyot than the SPC. The SPC we use was designed as a technology demonstrator only, with a contrast floor, throughput, and outer working angle poorly matched for SCExAO's current AO performance and poorly tuned for imaging the HR 8799 planets. Nevertheless, we detect HR 8799 cde with SCExAO/CHARIS using the SPC in broadband mode, where the signal-to-noise ratio for planet e is within 30 percent of that obtained using the vortex coronagraph. The shaped-pupil coronagraph is a promising design demonstrated to be robust in the presence of low-order aberrations and may be well-suited for future ground and space-based direct imaging observations, especially those focused on follow-up exoplanet characterization and technology demonstration of deep contrast within well-defined regions of the image plane.

Currie, Thayne↗