Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AORTA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

An Unusual Left Ventricular Outflow Pseudoaneurysm: Usefulness of Echocardiography and Multidetector Computed Tomography for Surgical Repair

Left ventricular outflow tract (LVOT) pseudoaneurysm is a rare but potentially lethal complication, mainly after aortic root endocarditis or surgery. Usually it originates from a dehiscence in the mitral-aortic intervalvular fibrosa and it arises posteriorly to the aortic root. Due to these anatomical features, its imaging assessment is challenging and surgical repair requires complex procedures. An unusual case of LVOT pseudoaneurysm is described. It was detected by transthoracic ecocardiography 7 months after aortic root replacement for acute endocarditis. Multidetector computed tomography (MDCT) confirmed the presence of a pouch located between the aortic root and the right atrium. Computed tomography also detected the origin of the pseudoaneurysm from the muscular interventricular septum of the LVOT, rather below the aortic valve plane. It was repaired with an extracardiac surgical approach, sparing the aortic root bioprosthesis previously implanted. The high-resolution three-dimensional details provided by the preoperative MDCT allowed us to plan a simple and effective surgical strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Ruptured Abdominal Aortic Aneurysms: An 8-year Single-Centre Experience

We aimed to review our experience with the endovascular treatment of ruptured abdominal aortic aneurysm (RAAA). During an 8-year period, 69 patients with a RAAA presented to our department; 67 underwent assessment by computed axial tomography, and 2 died on arrival before any evaluation was possible. A total of 42 patients (63%) were suitable for stent-grafting, and all but 1 (c-arm failure) proceeded to endovascular repair. Of these, 27 underwent surgery with local anaesthesia; 3 did so under general anaesthesia; and a further 11 procedures were commenced with the patient under local anaesthesia and then converted to general anaesthesia. A total of 28 bifurcated and 14 aorto-uni-iliac stent-grafts were implanted. Aortic occlusion balloons were used in 2 (5%) patients. The in-hospital and the 30-day mortality rates were 36% and 41%, respectively. After surgery, 21 complications were encountered in 17 patients. Two patients required reintervention during their hospital stay (1 type I endoleak and 1 limb occlusion). During the follow-up (median 730 days [range 90 to 580 days]), the 1-year and 5-year cumulative survival probabilities were 53% (SE 7.9%) and 50% (SE 8.0%), respectively. Three reinterventions were necessary during follow-up (2 type I endoleaks and 1 graft occlusion). We conclude that endovascular treatment is feasible in the emergency setting, and the early experience is promising. Whether such an approach is superior to open surgery remains to be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D Stereoscopic Visualization of Fenestrated Stent Grafts

The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total Percutaneous Aortic Repair: Midterm Outcomes

The purpose of this study was to examine the immediate and midterm outcomes of percutaneous endovascular repair of thoracic and abdominal aortic pathology. Between December 2003 and June 2005, 21 patients (mean age: 60.4 {+-} 17.1 years; 15 males, 6 females) underwent endovascular stent-graft insertion for thoracic (n = 13) or abdominal aortic (n = 8) pathology. Preprocedural computed tomographic angiography (CTA) was performed to assess the suitability of aorto-iliac and common femoral artery (CFA) anatomy, including the degree of CFA calcification, for total percutaneous aortic stent-graft repair. Percutaneous access was used for the introduction of 18- to 26-Fr delivery devices. A 'preclose' closure technique using two Perclose suture devices (Perclose A-T; Abbott Vascular) was used in all cases. Data were prospectively collected. Each CFA puncture site was assessed via clinical examination and CTA at 1, 6, and 12 months, followed by annual review thereafter. Minimum follow-up was 36 months. Outcome measures evaluated were rates of technical success, conversion to open surgical repair, complications, and late incidence of arterial stenosis at the site of Perclose suture deployment. A total of 58 Perclose devices were used to close 29 femoral arteriotomies. Outer diameters of stent-graft delivery devices used were 18 Fr (n = 5), 20 Fr (n = 3), 22 Fr (n = 4), 24 Fr (n = 15), and 26 Fr (n = 2). Percutaneous closure was successful in 96.6% (28/29) of arteriotomies. Conversion to surgical repair was required at one access site (3.4%). Mean follow-up was 50 {+-} 8 months. No late complications were observed. By CT criteria, no patient developed a >50% reduction in CFA caliber at the site of Perclose deployment during the study period. In conclusion, percutaneous aortic stent-graft insertion can be safely performed, with a low risk of both immediate and midterm access-related complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Results of Elective Abdominal Aortic Aneurysm Repair at a Low-Volume Hospital by Risk-Adjusted Selection of Treatment in the Endovascular Era

Several studies have observed both higher mortality rates and lower utilization of endovascular aneurysm repair (EVAR) at low-volume centers. This article presents the results of elective abdominal aortic aneurysm (AAA) repair at a low-volume center in the endovascular era and investigates whether postprocedural mortality can be improved by extension of EVAR application also in this setting. This is an 11.6-year retrospective cohort study of 132 patients undergoing elective surgical or endovascular AAA repair at a tertiary care academic hospital between 1997 and July 2008, i.e., a median volume of 12 cases per year. The study was divided into two periods of time according to the respective indications and contraindications for EVAR, which substantially changed in 2005. During period 1, only aneurysms with necks {>=}20 mm long and not involving the iliac arteries were treated endoluminally. Beginning in 2005, indication for EVAR was expanded to aortoiliac aneurysms with a minimum neck length of 15 mm. Preoperative risk was assessed by the SVS/AAVS comorbidity score. During the first period (1997-2004) 18.4% (16/87) of all patients received EVAR. By extending anatomical confines and indications for EVAR in 2005, the utilization rate of EVAR increased to 40.0% (18/45) during the second period (2005-July 2008; p = 0.007). Prevalence of preoperative risk factors did not change during the two observation periods. In contrast to period 1, high-risk patients were preferentially treated endoluminally during the second period, resulting in a significantly higher median SVS/AAVS score in the EVAR group (p < 0.001). A significant decrease in median length of stay at the intensive/intermediate care unit (5 vs. 2 days; p = 0.006) and length of in-hospital stay (20 vs. 12.5 days; p < 0.001) was observed during period 2. Overall perioperative mortality was reduced from 6.9% during the first period to 2.2% during the second period (p = 0.256). EVAR mortality was 0%, mortality after open repair was reduced from 8.5% to 3.7% (p = 0.414). In conclusion, by risk-adjusted selection of treatment and frequent application of EVAR, it is possible to improve perioperative outcome of elective AAA repair at a low-volume hospital. Mortality figures are similar to those of recent trials at high-volume centers, as reported in the literature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel 'Cheese Wire' Technique for Stent Positioning Following Difficult Iliac Artery Subintimal Dissection and Aortic Re-Entry

Subintimal wire dissection is a well-established method for traversing difficult vascular occlusions. This technique relies on re-entry of the true lumen distal to the occlusion, which may be difficult in diseased vessels with significant calcification. This case report describes a novel 'cheese wire' technique to allow stent positioning without the use of proprietary re-entry devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repair of Traumatic Abdominal Aortic Pseudoaneurysm Using N-Butyl-2-Cyano-Acrylate Embolization

Embolization using N-butyl-2-cyano-acrylate (NBCA) has been highly regarded for treating pseudoaneurysm, arteriovenous malformation, and hemorrhage of the visceral arteries. We report the case of a patient who fell from a cliff and sustained hemorrhagic shock with blunt abdominal aortic rupture and who underwent embolization using NBCA. This treatment achieved immediate hemostasis and stabilization of vital signs. Although the long-term durability of NBCA is unknown, it appears that certain types of acute aortic hemorrhage with narrow-necked pseudoaneurysm can be controlled by embolization using NBCA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of Ruptured Abdominal Aortic Aneurysm with Aortocaval Fistula

Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standard of Practice for the Endovascular Treatment of Thoracic Aortic Aneurysms and Type B Dissections

Thoracic endovascular aortic repair (TEVAR) represents a minimally invasive technique alternative to conventional open surgical reconstruction for the treatment of thoracic aortic pathologies. Rapid advances in endovascular technology and procedural breakthroughs have contributed to a dramatic transformation of the entire field of thoracic aortic surgery. TEVAR procedures can be challenging and, at times, extraordinarily difficult. They require seasoned endovascular experience and refined skills. Of all endovascular procedures, meticulous assessment of anatomy and preoperative procedure planning are absolutely paramount to produce optimal outcomes. These guidelines are intended for use in quality-improvement programs that assess the standard of care expected from all physicians who perform TEVAR procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type II Endoleak After Endovascular Repair of Abdominal Aortic Aneurysm: Effectiveness of Embolization

The purpose of this study was to report our experience in treating type II endoleaks after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms. Two hundred eighteen patients underwent EVAR with a Zenith stent-graft from January 2000 to December 2005. During a follow-up period of 4.5 {+-} 2.3 years, solely type II endoleak was detected in 47 patients (22%), and 14 of them underwent secondary interventions to correct this condition. Ten patients had transarterial embolization, and four patients had translumbar/transabdominal embolization. The embolization materials used were coils, thrombin, gelatin, Onyx (ethylene-vinyl alcohol copolymer), and glue. Disappearance of the endoleak without enlargement of the aneurysm sac after the first secondary intervention was achieved in only five of these patients (5/13). One patient without surveillance imaging was excluded from analyses of clinical success. After additional interventions in four patients and the spontaneous disappearance of type II endoleak in two patients, overall clinical success was achieved in eight patients (8/12). One patient did not have surveillance imaging after the second secondary intervention. Clinical success after the first secondary intervention was achieved in two patients (2/9) in the transarterial embolization group and three patients (3/4) in the translumbar embolization group. The results of secondary interventions for type II endoleak are unsatisfactory. Although the small number of patients included in this study prevents reliable comparisons between groups, the results seem to favor direct translumbar embolization in comparison to transarterial embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Endovascular Treatment of Sac Rupture for Type IIIa Endoleak in Thoracic Aortic Aneurysm Previously Excluded with Endovascular Repair

Elective endovascular treatment of thoracic aortic pathology has been applied in a variety of conditions. The complications of thoracic aortic stenting are also well recognized. Endoleak after endovascular repair of thoracic aortic aneurysms is the most frequent complication; among them, type III is the least frequent. Endovascular treatment of type III endoleak is generally performed under elective conditions; less frequently, in emergency. We report a successful emergency endovascular management of post-thoracic endovascular repair for thoracic aortic aneurysm rupture due to type IIIa endoleak.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A New Cone-Shaped Aortic Valve Prosthesis for Orthotopic Position: An Experimental Study in Swine

The aim of this experimental study was to evaluate a newly designed cone-shaped aortic valve prosthesis (CAVP) for one-step transcatheter placement in an orthotopic position. The study was conducted in 15 swine using either the transcarotid (11 animals) or the transfemoral (4 animals) artery approach. A 12- or 13-Fr sheath was inserted via arterial cutdown. The CAVP was deployed under fluoroscopic control and its struts, by design, induced significant native valve insufficiency. CAVP function was evaluated by aortography and aortic pressure curve tracing. In 11 of 15 swine the CAVP was properly deployed and functioned well throughout the scheduled period of 2-3 h. In three swine the CAVPs were placed lower than intended, however, they were functional even in the left ventricular outflow tract position. One swine expired due to inadvertent low CAVP placement that caused both aortic regurgitation and immobilization of the anterior mitral valve leaflet by the valve struts. We conclude that this design of CAVP is relatively easy to deploy, works well throughout a short time period (2-3 h), and, moreover, seems to be reliable even in a lower-than-orthotopic position (e.g., infra-annulary space). Longer-term studies are needed for its further evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair

PurposeIntraoperative sac pressure was measured during endovascular abdominal aortic aneurysm repair (EVAR) to evaluate the clinical significance of sac pressure measurement.MethodsA microcatheter was placed in an aneurysm sac from the contralateral femoral artery, and sac pressure was measured during EVAR procedures in 47 patients. Aortic blood pressure was measured as a control by a catheter from the left brachial artery.ResultsThe systolic sac pressure index (SPI) was 0.87 {+-} 0.10 after main-body deployment, 0.63 {+-} 0.12 after leg deployment (P < 0.01), and 0.56 {+-} 0.12 after completion of the procedure (P < 0.01). Pulse pressure was 55 {+-} 21 mmHg, 23 {+-} 15 mmHg (P < 0.01), and 16 {+-} 12 mmHg (P < 0.01), respectively. SPI showed no significant differences between the Zenith and Excluder stent grafts (0.56 {+-} 0.13 vs. 0.54 {+-} 0.10, NS). Type I endoleak was found in seven patients (15%), and the SPI decreased from 0.62 {+-} 0.10 to 0.55 {+-} 0.10 (P = 0.10) after fixing procedures. Type II endoleak was found in 12 patients (26%) by completion angiography. The SPI showed no difference between type II endoleak positive and negative (0.58 {+-} 0.12 vs. 0.55 {+-} 0.12, NS). There were no significant differences between the final SPI of abdominal aortic aneurysms in which the diameter decreased in the follow-up and that of abdominal aortic aneurysms in which the diameter did not change (0.53 {+-} 0.12 vs. 0.57 {+-} 0.12, NS).ConclusionsSac pressure measurement was useful for instant hemodynamic evaluation of the EVAR procedure, especially in type I endoleaks. However, on the basis of this small study, the SPI cannot be used to reliably predict sac growth or regression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Type II Endoleak After Endovascular Aortic Repair: Comparison Between Magnetic Resonance Angiography and Blood-Pool Contrast Agent and Dual-Phase Computed Tomography Angiography

PurposeThis prospective study was designed to assess the diagnostic value of magnetic resonance angiography (MRA) with blood-pool contrast agent (gadofosveset) in the detection of type-II endoleak after endovascular aortic repair (EVAR).MethodsThirty-two patients with aortic aneurysms who had undergone EVAR were included in this study. All patients were examined by dual-phase computed tomography angiography (CTA) as well as MRA with gadofosveset in the first-pass and steady-state phases. Two independent readers evaluated the images of CTA and MRA in terms of endoleak type II, feeding vessel, and image quality.ResultsMedian follow-up-time after EVAR was 22 months (range 4 to 59). Endoleak type II was detected by CTA in 12 of 32 patients (37.5%); MRA detected endoleak in all of these patients as well as in another 9 patients (n = 21, 65.6%), of whom the endoleaks in 6 patients showed an increasing diameter. Most endoleaks were detected in the steady-state phase (n = 14). The decrease in diameter of the aneurysmal sac was significantly greater in the patients without a visible endoleak that was visible on MRA (P = 0.004). In the overall estimation of diagnostic accuracy, MRA was judged superior to CTA in 66% of all examinations.ConclusionMRA with gadofosveset appeared superior to CTA, and has higher diagnostic accuracy, in the detection of endoleak after EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗