Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Phase transitions and equations of state of alkaline earth fluorides CaF[subscript 2], SrF[subscript 2], and BaF[subscript 2] to Mbar pressures

Phase transitions and equations of state of the alkaline earth fluorides CaF{sub 2}, SrF{sub 2}, and BaF{sub 2} were examined by static compression to pressures as high as 146 GPa. Angle-dispersive x-ray diffraction experiments were performed on polycrystalline samples in the laser-heated diamond-anvil cell. We confirmed that at pressures less than 10 GPa all three materials undergo a phase transition from the cubic (Fm{bar 3} m) fluorite structure to the orthorhombic (Pnam) cotunnite-type structure. This work has characterized an additional phase transition in CaF{sub 2} and SrF{sub 2}: these materials were observed to transform to a hexagonal (P6{sub 3}/mmc) Ni{sub 2}In-type structure between 63-79 GPa and 28-29 GPa, respectively, upon laser heating. For SrF{sub 2}, the Ni{sub 2}In-type phase was confirmed by Rietveld refinement. Volumes were determined as a function of pressure for all high-pressure phases and fit to the third-order Birch-Murnaghan equation of state. For CaF{sub 2} and SrF{sub 2}, the fluorite-cotunnite transition results in a volume decrease of 8-10%, while the bulk modulus of the cotunnite-type phase is the same or less than that of the fluorite phase within uncertainty. For all three fluorides, the volume reduction associated with the further transition to the Ni{sub 2}In-type phase is {approx}5%. The percentage increase in the bulk modulus ({Delta}K) across the transition is greater when the cation is smaller. While for BaF{sub 2}, {Delta}K is 10-30%, {Delta}K values for SrF{sub 2} and CaF{sub 2} are 45-65% and 20-40%. Although shock data for CaF{sub 2} have been interpreted to show a transition to a highly incompressible phase above 100 GPa, this is not consistent with our static equation of state data.

36 MATERIALS SCIENCE↗

Synchrotron X-ray diffraction measurements of single-crystal hydrogen to 26.5 gigapascals

The crystal structure and equation of state of solid hydrogen have been determined directly to 26.5 gigapascals at room temperature by new synchrotron X-ray diffraction techniques. Solid hydrogen remains in the hexagonal close packed structure under these pressure-temperature conditions and exhibits increasing structural anisotropy with pressure. The pressure-volume curve determined from the X-ray data represents the most accurate experimental measurement of the equation of state to date in this pressure range. The results remove the discrepancy between earlier indirect determinations and provide a new experimental constraint on the molecular-to-atomic transition predicted at higher pressures.

Mao, H. K.↗

Phase Transitions and Equations of State of Alkaline Earth Fluorides CaF2 SrF2 and BaF2 to Mbar Pressures

Phase transitions and equations of state of the alkaline earth fluorides CaF{sub 2}, SrF{sub 2}, and BaF{sub 2} were examined by static compression to pressures as high as 146 GPa. Angle-dispersive x-ray diffraction experiments were performed on polycrystalline samples in the laser-heated diamond-anvil cell. We confirmed that at pressures less than 10 GPa all three materials undergo a phase transition from the cubic (Fm3{sup -}m) fluorite structure to the orthorhombic (Pnam) cotunnite-type structure. This work has characterized an additional phase transition in CaF{sub 2} and SrF{sub 2}: these materials were observed to transform to a hexagonal (P6{sub 3}/mmc) Ni{sub 2}In-type structure between 63-79 GPa and 28-29 GPa, respectively, upon laser heating. For SrF{sub 2}, the Ni{sub 2}In-type phase was confirmed by Rietveld refinement. Volumes were determined as a function of pressure for all high-pressure phases and fit to the third-order Birch-Murnaghan equation of state. For CaF{sub 2} and SrF{sub 2}, the fluorite-cotunnite transition results in a volume decrease of 8-10%, while the bulk modulus of the cotunnite-type phase is the same or less than that of the fluorite phase within uncertainty. For all three fluorides, the volume reduction associated with the further transition to the Ni{sub 2}In-type phase is {approx}5%. The percentage increase in the bulk modulus ({Delta}K) across the transition is greater when the cation is smaller. While for BaF{sub 2}, {Delta}K is 10-30%, {Delta}K values for SrF{sub 2} and CaF{sub 2} are 45-65% and 20-40%. Although shock data for CaF{sub 2} have been interpreted to show a transition to a highly incompressible phase above 100 GPa, this is not consistent with our static equation of state data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A comprehensive study of low-energy response for xenon-based dark matter experiments

Here we report a comprehensive study of the energy response to low-energy recoils in dual-phase xenon-based dark matter experiments. A recombination model is developed to explain the recombination probability as a function of recoil energy at zero field and non-zero field. The role of e-ion recombination is discussed for both parent recombination and volume recombination. We find that the volume recombination under a non-zero field is constrained by a plasma effect, which is caused by a high density of charge carriers along the ionization track forming a plasma-like cloud of charge that shields the interior from the influence of the external electric field. Subsequently, the plasma time that determines the volume recombination probability at non-zero field is demonstrated to be different between electronic recoils (ERs) and nuclear recoils (NRs) due to the difference of ionization density between two processes. We show a weak field dependence of the plasma time for NRs and a stronger field dependence of the plasma time for ERs. As a result, the time-dependent recombination is implemented in the determination of charge and light yield with a generic model. Our model agrees well with the available experimental data from xenon-based dark matter experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cardiac and Vascular Responses to Thigh Cuffs and Respiratory Maneuvers on Crewmembers of the International Space Station

The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, and a decrease in leg diameter. This experiment examined the responses to modified Valsalva and Mueller maneuvers measured by cardiac and vascular ultrasound (ECHO) in a baseline steady state and during preload reduction introduced with thigh occlusion cuffs used as a counter-measure device (Braslet cuffs) measured by cardiac and vascular ultrasound examinations. Methods: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 +/- 46.days after launch (mean +/- SD; 33 - 185). Twenty Seven cardiac and vascular parameters were obtained with/without respiratory maneuvers before and after tightening of the Braslet cuffs. Results: Non-physicians performed diagnostic-quality cardiac and vascular ultrasound examinations using remote guidance. Three of 27 combinations of maneuvers and Braslet or Braslet alone were identified as being significant changed when compared to baseline. Eleven of 81 differences between combinations of Mueller, Valsalva or baseline were significant and related to cardiac preload reduction or increase in lower extremity venous volume. Conclusions: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts commensurate measurable effects on cardiac performance in microgravity. Ultrasound techniques to measure the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an invaluable tool in determining the volume status of the cardiac patient at the 'microgravity bedside'.

Hamilton, Douglas↗

Material hardness at strain rates beyond 10 6 s –1 via high velocity microparticle impact indentation

Despite advances in mechanical testing at small scales and testing at high strain rates, studies of mechanical behavior of materials remain largely qualitative in the regimes where these two conditions overlap. In this work, we present an approach based on microparticle impact indentation to determine material hardness at micron scales and at high strain rates. We employ laser ablation to impact ceramic alumina microparticles (as indenter) onto two model materials, namely copper and iron. We use real time measurements of impact and rebound velocities together with post- impact measurements of indentation volume to determine material hardness at strain rates beyond 10 6 s –1 .

36 MATERIALS SCIENCE↗

Schroeter's ratios for Martian craters - Radar results

Schroeter's ratios (ratios of the rim volume to the apparent volume) are determined for a sample of 29 large, degraded Martian craters selected from the Goldstone Mars radar altimetry data. On the average, the values of the calculated Schroeter's ratios are about two orders of magnitude smaller than the same ratios for fresh lunar craters. This indicates a severe rim volume deficit in degraded Martian craters and it provides an additional support to the notion of a widespread resurfacing of intercrater plains on Mars. Schroeter's ratios for degraded craters could provide a semi-quantitative measure of the effects of the modification processes that had been active on Mars and on the other planetary bodies.

Roth, Ladislav E.↗

Calibration of the Gamma Knife using a new phantom following the AAPM TG51 and TG21 protocols

Purpose: To compare calibration of the Leksell Gamma Knife according to the American Association of Physicists in Medicine Task Groups 21 and 51 protocols. A new phantom was fabricated for this purpose. Its design, physical properties, and composition are described. Materials and methods: The Gamma Knife TG-51 calibration phantom is designed to be filled with water and support an ionization chamber positioned at its center. The phantom is thimble-shaped, with a 2 mm plastic wall to contain water. The phantom and chamber assembly was mounted in a LeksellTM stereotactic frame. The location of the chamber's sensitive volume was determined using computed tomography. The chamber-phantom assembly was attached to the 18 mm helmet in the Gamma Knife by the stereotactic frame. The phantom's geometry allowed radiation beams from each of the 201 Gamma Knife cobalt-60 sources to converge after an 8 cm path to the ionization chamber's sensitive volume. This is similar to the arrangement by which one calibrates the Gamma Knife using the manufacturer-supplied polystyrene phantom. Results: The phantom was attached to the Gamma Knife so that the ionization chamber was reproducibly positioned at the convergence of the radiation beams. Because of the phantom's design, the phantom could be affixed to either trunnions or the automatic patient positioning system, once mounted in the LeksellTM stereotectic frame. Comparisons using different phantoms and protocols resulted in the following calibration ratios for TG-21 in the polystyrene sphere phantom, TG-21 in the water phantom, and TG-51 in the water phantom, respectively: 1.000, 1.008, 0.986, when corrected for transmission through the plastic water reservoir wall and using the same ionization chamber. Transmission measurements using a 1 cm thickness of the same material in the Co-60 beam determined that the phantom's 2 mm plastic wall resulted in a reduction in the measured the output by 0.5%. Conclusions: Calibration of the Gamma Knife can be performed in liquid water using the AAPM TG-51 protocol and this new phantom, thereby eliminating uncertainties with respect to the composition of the manufacturer's phantom. Perturbation of calibration measurements by nonwater materials was characterized and could be corrected. Calibration values for the Gamma Knife that were obtained using the three methods for our phantoms agree to within 1.4%. TG21 and TG51 calibration of the Gamma Knife using the water phantom agreed to within 2.2%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-223: Computed Radiography Dose Measurements of External Radiotherapy Beams

Purpose: To obtain quantitative, two-dimensional dose measurements of external radiotherapy beams with a computed radiography (CR) system and to derive volume correction factors for ionization chambers in small fields. Methods: A commercial Kodak ACR2000i CR system with Kodak Flexible Phosphor Screen HR storage foils was used. Suitable measurement conditions and procedures were established. Several corrections were derived, including image fading, length-scale corrections and long-term stability corrections. Dose calibration curves were obtained for cobalt, 4 MV, 8 MV and 25 MV photons, and for 10 MeV, 15 MeV and 18 MeV electrons in a water phantom. Inherent measurement inhomogeneities were studied as well as directional dependence of the response. Finally, 2D scans with ionization chambers were directly compared to CR measurements, and volume correction factors were derived. Results: Dose calibration curves (0.01 Gy to 7 Gy) were obtained for multiple photon and electron beam qualities. For each beam quality, the calibration curves can be described by a single fit equation over the whole dose range. The energy dependence of the dose response was determined. The length scale on the images was adjusted scan-by-scan, typically by 2 percent horizontally and by 3 percent vertically. The remaining inhomogeneities after the system’s standard calibration procedure were corrected for. After correction, the homogeneity is on the order of a few percent. The storage foils can be rotated by up to 30 degrees without a significant effect on the measured signal. First results on the determination of volume correction factors were obtained. Conclusion: With CR, quantitative, two-dimensional dose measurements with a high spatial resolution (sub-mm) can be obtained over a large dose range. In order to make use of these advantages, several calibrations, corrections and supporting measurements are needed. This work was funded by the European Metrology Research Programme (EMRP) project HLT09 MetrExtRT Metrology for Radiotherapy using Complex Radiation Fields.

60 APPLIED LIFE SCIENCES↗

Shuttle orbiter with telescoping main propulsion unit and payload

An improved Space Shuttle with variable internal volume is provided. The Space Shuttle Orbiter includes a telescoping main propulsion unit. This main propulsion unit contains the main rocket engines and fuel tanks and telescopes into the Space Shuttle. A variable cavity is located between this unit and the crew compartment. Accordingly, the positioning of the telescoping main propulsion unit determines the volume of the variable cavity. Thus, the volume of the variable length of the entire Space Shuttle may be increased or decreased to achieve desired configurations for optimal storage. In one embodiment of the invention, the payload also telescopes within the variable cavity.

Macconochie, Ian O.↗

Fluid flow volume measurements using a capacitance/conductance probe system

A probe system has been developed to measure the flow volume of a single fluid passing through an orifice or flow line. The system employs both capacitance and a conductance probe at the orifice, together with phase detection and data acquisition circuitry to measure flow volume and salinity under low or zero gravity conditions. A wide variety of frequencies can be used for the radio frequency (RF) signal source which is chosen primarily by the capacitance of the orifice probe and the fluid passing through the orifice. Rapid measurements are made using the reflected signal from the orifice probe to determine the 'instantaneous' permittivity of the fluid/gas mixture passing through. The 'instantaneous' measurements are integrated over time to determine flow volume. Analysis reveals that a narrow orifice helps to reduce non-linearities caused by differing flow rates. The geometry of 'deflectors' and 'directors' for the flowing fluid are important in obtaining linearity. Measured data shows that a volume measurement accuracy of approximately four percent can be consistently achieved. The prototype hardware system and associated software have been optimized and are available for further applications. The system has immediate application in low or zero gravity environments for measurements of urine or other liquid volumes.

Nguyen, T. X.↗

Generalizing the relativistic quantization condition to include all three-pion isospin channels

We present a generalization of the relativistic, finite-volume, three-particle quantization condition for non-identical pions in isosymmetric QCD. The resulting formalism allows one to use discrete finite-volume energies, determined using lattice QCD, to constrain scattering amplitudes for all possible values of two- and three-pion isospin. As for the case of identical pions considered previously, the result splits into two steps: the first defines a non-perturbative function with roots equal to the allowed energies, E n (L), in a given cubic volume with side-length L. This function depends on an intermediate three-body quantity, denoted K d f , 3 , which can thus be constrained from lattice QCD in- put. The second step is a set of integral equations relating K d f , 3 to the physical scattering amplitude, M 3 . Both of the key relations, En(L) ↔ K d f , 3 and K d f , 3 &#x2194;<!-- ↔ --> M 3 , are shown to be block-diagonal in the basis of definite three-pion isospin, Iπππ , so that one in fact recovers four independent relations, corresponding to Iπππ = 0, 1, 2, 3. We also provide the generalized threshold expansion of K d f , 3 for all channels, as well as parameterizations for all three-pion resonances present for Iπππ = 0 and Iπππ = 1. As an example of the utility of the generalized formalism, we present a toy implementation of the quantization condition for Iπππ = 0, focusing on the quantum numbers of the ω and h 1 resonances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-488: Comparison of the TG-51 and TG-51 Addendum Calibration Protocols

Purpose: To quantify differences between the TG51 and TG51 addendum calibration protocols. Methods: Beam energies of 6X, 6XSRS, 10X, 15X, 23X, 6XFFF, and 10XFFF were calibrated following both the TG51 and TG51 addendum protocols using both a Farmer and a scanning ionization chamber with traceable absorbed dose-to-water calibrations. For the TG51 addendum procedure, the collimating jaws were positioned to define a 10×10cm{sup 2} radiation field, a lead foil was only used for kQ measurements of FFF energies, and a volume-averaging correction was applied based on crossline and inline dose profiles. For the TG51 procedure, the collimating jaws were set to 10×10cm{sup 2} according to the digital readout, and a lead foil was used for kQ measurements of energies greater than 10MV. Results: For beam energies with a flattening filter, absorbed dose-to-water determined by the two protocols differed by 0.1%–0.3%. For FFF beam energies, differences between the protocols were up to 0.2% and 0.8% for the scanning and Farmer ionization chambers, respectively. Differences between the protocols were due to kQ determination, volume-averaging correction, and measurement of raw ionization. Differences in kQ values between the two protocols were up to 0.4% and 0.2% for the scanning and Farmer ionization chambers, respectively. Volume-averaging corrections were less than 0.1% for the scanning ionization chamber, and up to 0.4% and 0.6% for the Farmer ionization chamber in beams with a flattening filter and FFF beams, respectively. Raw ionization measurements differed up to 0.3%±0.07% due to differences in jaw settings. Conclusion: The TG51 and TG51 addendum calibration protocols differed less than 0.3% for the scanning ionization chamber. For the Farmer chamber in FFF energies, volume-averaging corrections of up to 0.6% contributed to calibration differences of up to 0.8%. Failure to verify the radiation field size can produce calibration differences of up to 0.3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Luminosity determination using Z boson production at the CMS experiment

The measurement of Z boson production is presented as a method to determine the integrated luminosity of CMS data sets. The analysis uses proton–proton collision data, recorded by the CMS experiment at the CERN LHC in 2017 at a center-of-mass energy of 13 TeV. Events with Z bosons decaying into a pair of muons are selected. The total number of Z bosons produced in a fiducial volume is determined, together with the identification efficiencies and correlations from the same data set, in small intervals of 20 pb –1 of integrated luminosity, thus facilitating the efficiency and rate measurement as a function of time and instantaneous luminosity. Using the ratio of the efficiency-corrected numbers of Z bosons, the precisely measured integrated luminosity of one data set is used to determine the luminosity of another. For the first time, a full quantitative uncertainty analysis of the use of Z bosons for the integrated luminosity measurement is performed. The uncertainty in the extrapolation between two data sets, recorded in 2017 at low and high instantaneous luminosity, is less than 0.5%. We show that the Z boson rate measurement constitutes a precise method, complementary to traditional methods, with the potential to improve the measurement of the integrated luminosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volume and Mass Estimation of Three-Phase High Power Transformers for Space Applications

Spacecraft historically have had sub-1kW(sub e), electrical requirements for GN&C, science, and communications: Galileo at 600W(sub e), and Cassini at 900W(sub e), for example. Because most missions have had the same order of magnitude power requirements, the Power Distribution Systems (PDS) use existing, space-qualified technology and are DC. As science payload and mission duration requirements increase, however, the required electrical power increases. Subsequently, this requires a change from a passive energy conversion (solar arrays and batteries) to dynamic (alternator, solar dynamic, etc.), because dynamic conversion has higher thermal and conversion efficiencies, has higher power densities, and scales more readily to higher power levels. Furthermore, increased power requirements and physical distribution lengths are best served with high-voltage, multi-phase AC to maintain distribution efficiency and minimize voltage drops. The generated AC-voltage must be stepped-up (or down) to interface with various subsystems or electrical hardware. Part of the trade-space design for AC distribution systems is volume and mass estimation of high-power transformers. The volume and mass are functions of the power rating, operating frequency, the ambient and allowable temperature rise, the types and amount of heat transfer available, the core material and shape, the required flux density in a core, the maximum current density, etc. McLyman has tabulated the performance of a number of transformers cores and derived a "cookbook" methodology to determine the volume of transformers, whereas Schawrze had derived an empirical method to estimate the mass of single-phase transformers. Based on the work of McLyman and Schwarze, it is the intent herein to derive an empirical solution to the volume and mass estimation of three-phase, laminated EI-core power transformers, having radiated and conducted heat transfer mechanisms available. Estimation of the mounting hardware, connectors, etc. is not included.

Kimnach, Greg L.↗

A mechanism of adaptation to hypergravity in the statocyst of Aplysia californica

The gravity-sensing organ of Aplysia californica consists of bilaterally paired statocysts containing statoconia, which are granules composed of calcium carbonate crystals in an organic matrix. In early embryonic development, Aplysia contain a single granule called a statolith, and as the animal matures, statoconia production takes place. The objective of this study was to determine the effect of hypergravity on statoconia production and homeostasis and explore a possible physiologic mechanism for regulating this process. Embryonic Aplysia were exposed to normogravity or 3 x g or 5.7 x g and each day samples were analyzed for changes in statocyst, statolith, and body dimensions until they hatched. In addition, early metamorphosed Aplysia (developmental stages 7-10) were exposed to hypergravity (2 x g) for 3 weeks, and statoconia number and statocyst and statoconia volumes were determined. We also determined the effects of hypergravity on statoconia production and homeostasis in statocysts isolated from developmental stage 10 Aplysia. Since prior studies demonstrated that urease was important in the regulation of statocyst pH and statoconia formation, we also evaluated the effect of hypergravity on urease activity. The results show that hypergravity decreased statolith and body diameter in embryonic Aplysia in a magnitude-dependent fashion. In early metamorphosed Aplysia, hypergravity decreased statoconia number and volume. Similarly, there was an inhibition of statoconia production and a decrease in statoconia volume in isolated statocysts exposed to hypergravity in culture. Urease activity in statocysts decreased after exposure to hypergravity and was correlated with the decrease in statoconia production observed. In short, there was a decrease in statoconia production with exposure to hypergravity both in vivo and in vitro and a decrease in urease activity. It is concluded that exposure to hypergravity downregulates urease activity, resulting in a significant decrease in the formation of statoconia.

NASA Program Space Biology↗

Application of x-ray and neutron diffraction to determine lattice parameters and precipitate volume fractions in low misfit nickel base superalloys.

Synchrotron X-ray diffraction and neutron diffraction techniques are employed to characterise the lattice parameters and volume fraction of {gamma} and {gamma}{prime} phases in a high strength nickel base superalloy. Samples of Rene88DT were solutionized at 1150 C and cooled under three different rates to provide fine and coarse {gamma}{prime} size distributions. Samples were aged at 760 C to precipitate tertiary {gamma}{prime} and coarsen secondary precipitates. Lattice parameter misfit and coefficient of thermal expansion parameters were also determined. Results indicate significant microstructure changes within the samples during the initial 25 h of aging.

36 MATERIALS SCIENCE↗