Electric Vehicle Fire Primer for Fleet Managers

The U.S. Department of Energy's Vehicle Technologies Office provides project assistance through Clean Cities, technical expertise, and funding to help stake-holders implement alternative fuels and electric vehicles (EVs). Fleet managers considering EVs can learn about the potential for EV fires and measures to help reduce fire risk.

ADVANCED PROPULSION SYSTEMS↗

Status of LBNF/DUNE near site liquid argon proximity and external cryogenics systems development.

The Deep Underground Neutrino Experiment (DUNE) near site located at Fermilab will host the neutrino beam complex. It includes a high voltage liquid argon time projection chamber located 60-meter underground used as beamline instrumentation. The LAr cryogenic system provided by the Long-Baseline Neutrino Facility (LBNF) regulates thermohydraulic conditions of the membrane cryostat hosting the detector with 285 Ton purified LAr. The purification system uses molecular sieve and copper oxide pellets to manage the argon contamination below 100 ppt (parts per trillion) oxygen equivalent. The detector and its cryogenics are capable to move a stroke of 30 meters on/off beam. The cryogenic system modes of operation include the cryostat pressure test, purge in open loop, detector cooldown, cryostat fill, closed loop purification, liquid empty, and purification system activation/regeneration process. The system design status and schedule, and technical details such as operating modes and interfaces are reported in this paper.

43 PARTICLE ACCELERATORS↗

DLMP of Competitive Markets in Active Distribution Networks: Models, Solutions, Applications, and Visions

Traditionally, the electric distribution system operates with uniform energy prices across all system nodes. However, as the adoption of distributed energy resources (DERs) propels a shift from passive to active distribution network (ADN) operation, a distribution-level electricity market has been proposed to manage new complexities efficiently. In addition, distribution locational marginal price (DLMP) has been established in the literature as the primary pricing mechanism. The DLMP inherits the LMP concept in the transmission-level wholesale market but incorporates characteristics of the distribution system, such as high $R/X$ ratios and power losses, system imbalance, and voltage regulation needs. The DLMP provides a solution that can be essential for competitive market operation in future distribution systems. This article first provides an overview of the current distribution-level market architectures and their early implementations. Next, the general clearing model, model relaxations, and DLMP formulation are comprehensively reviewed. The state-of-the-art solution methods for distribution market clearing are summarized and categorized into centralized, distributed, and decentralized methods. Then, DLMP applications for the operation and planning of DERs and distribution system operators (DSOs) are discussed in detail. Finally, visions of future research directions and possible barriers and challenges are presented.

42 ENGINEERING↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Navigating the Use of Direct Current in Residential Settings: Merits and Obstacles

This review paper provides an in-depth analysis of the role of Direct Current (DC) power systems in residential settings, focusing on their safety, efficiency, and environmental advantages. It recognizes the significant contribution of the residential sector to global carbon dioxide emissions and explores how DC power systems can help mitigate these effects. The paper traces the historical evolution of DC power, its resurgence with renewable energy technologies, and the advancements in power electronics that facilitate its integration. Emphasizing the efficiency and safety benefits, especially in low-voltage applications, the paper highlights the seamless integration of DC systems with inherently DC-generating renewable sources like solar PV and wind. The review discusses the critical role of converter technologies in the transition to DC power and examines the compatibility of DC systems with energy storage solutions, underscoring their potential for enhanced energy management. It also addresses the environmental impacts of adopting DC power, aligning with global carbon reduction efforts. The paper analyzes regional case studies, exploring practical applications and outcomes, and addresses challenges such as the need for standardization. It concludes with recommendations for stakeholders and future research directions, emphasizing the economic, technological, and environmental aspects of DC power systems. Overall, the paper presents DC power as a viable and sustainable option for residential energy conservation, contingent upon ongoing technological progress, supportive policies, and standardization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impact of energy-efficiency upgrades and other distributed energy resources on a residential neighborhood-scale electrification retrofit

We report ambitious targets for carbon emissions reductions are highlighting new challenges for electrification strategies, leading to an increased focus on building load flexibility and energy management to complement the variability inherent in renewable energy generation. Over the next decade millions of existing homes could undergo electrification retrofits, and there is an urgent need to understand the potential impacts of electrifying major residential loads such as water and space heating on community load characteristics, resident energy bills, and the utility's distribution system. Behind-the-meter distributed energy resources (DERs), including efficiency measures, photovoltaics (PV), battery storage, managed electric vehicle (EV) charging, and controls such as home energy management systems (HEMS), can significantly alter a neighborhood's load profile and provide benefits to both the residents and the grid. We present a novel approach to characterizing the impact of a hypothetical neighborhood-scale residential retrofit program on individual homes' energy use profiles, associated utility bills, and the local distribution system. We modeled a mixed-fuel community of 30 single-family homes in Denver, Colorado, and compared the effects of retrofit scenarios ranging from conventional energy-efficiency upgrades to full electrification with and without more advanced DER technologies. We analyzed which packages of DERs most reliably enable demand flexibility in response to a time-of-use (TOU) rate for this and similar neighborhoods. Our buildings-to-grid co-simulation framework includes a generic secondary distribution feeder model to capture voltage profiles, transformer loading, and other grid impacts in each case. We also calculated the carbon emissions associated with energy use in the community. The methodology developed here can be broadly applied to community-scale beneficial electrification studies in other regions, climates, utility infrastructures, and building typologies to make specific, targeted recommendations based on quantified projections of energy demand in any given community. Our findings indicate that residential electrification can be achieved without negatively impacting the monthly utility bill, and that a combination of conventional energy-efficiency measures, PV, battery, controls, and managed EV charging to maximize a community's demand flexibility is a promising strategy. Adding DERs (especially PV) as part of efficient electrification produces much bigger savings than efficient electrification without DERs. A key barrier is that upgrades require upfront costs, and modest utility bill savings result in long payback periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Efficient Electrochemical Tanks-in-Series Model for Lithium Sulfur Batteries

This article applies and efficiently implements the Tanks-in-Series methodology ( J. Electrochem. Soc. , 167 , 013534 (2020)) to generate a computationally efficient electrochemical model for Lithium-Sulfur batteries. The original Tank model approach for Lithium-ion batteries is modified to account for porosity changes with time. In addition, an exponential scaling method is introduced that enables efficient simulation of the model equations to address the wide range of time constants present for different reactions in the Lithium-Sulfur system. The Tank Model achieves acceptable voltage error even for transport-limited discharged conditions. Predictions of internal electrochemical variables are examined, and electrochemical implications of the approximations discussed. This suggests significant potential for real-time applications such as optimal charging, cell-balancing, and estimation, and represents a step forward in efforts to incorporate detailed electrochemical models in advanced Battery Management Systems for Lithium-Sulfur batteries.

Parke, Caitlin D. (ORCID:0000000177324044)↗

Field-dependent carrier transport in implanted isolation region of GaN lateral power devices

Among GaN lateral power devices, with proper E-field management, the breakdown occurs in the device isolation region rather than the active region. In this paper, we investigate field-dependent carrier transport in the isolation structures. Isolation test structures with variations in buffer doping, un-intentionally doped (UID) GaN thickness, and implantation conditions were fabricated. Electrical characterization was performed over a wide range of voltage and temperature. With varying UID GaN thickness and buffer doping, the leakage current and breakdown characteristics remain the same for a specific implantation condition, indicating that the leakage conduction and breakdown are governed by the implanted GaN region. Analysis of the temperature-dependent I–V reveals that carrier transport in the implanted GaN can be well explained by hopping conduction, involving three distinctive regions of operation depending on the E-field. At low E-field, carrier transport is ohmic, consistent with variable range hopping, driven by thermal activation. At medium E-field, a field enhanced thermally activated hopping is observed, following σ ∼ σ(T)exp(E). At high E-field, activation-less hopping is visible, following σ ∼ exp(−1/E), which occurs above a critical E-field limited by localization length.

Sadek, Mansura (ORCID:0000000322588338)↗

Dynamic cycling enhances battery lifetime

Laboratory aging campaigns benchmark and elucidate the complex degradation behavior of lithium-ion batteries, and are critical not only for developing new battery chemistries and cell designs but also for engineering reliable battery management systems. Critically, these laboratory experiments aim to quantify and capture realistic aging mechanisms. In this study, we systematically compare dynamic discharge profiles representative of electric vehicle driving to the well-accepted constant-current profiles. Surprisingly, we discovered that dynamic discharge enhances lifetime substantially compared to constant current discharge. Specifically, for the same average current and voltage window, varying the dynamic discharge profile leads to an increase of up to 38 % in equivalent full cycles at end-of-life. Explainable machine learning reveals the importance of low-frequency current pulses as well as time-induced aging under these realistic discharge conditions. Our work quantifies the importance of evaluating new battery chemistries and designs with realistic load profiles, and highlights the opportunities to revisit our understanding of aging mechanisms at the chemistry, materials, and cell levels.

25 ENERGY STORAGE↗

Self-regulating power management for a neural network system

A neural network runs a known input data set using an error free power setting and using an error prone power setting. The differences in the outputs of the neural network using the two different power settings determine a high level error rate associated with the output of the neural network using the error prone power setting. If the high level error rate is excessive, the error prone power setting is adjusted to reduce errors by changing voltage and/or clock frequency utilized by the neural network system. If the high level error rate is within bounds, the error prone power setting can remain allowing the neural network to operate with an acceptable error tolerance and improved efficiency. The error tolerance can be specified by the neural network application.

Kegel, Andrew G.↗

Self-regulating power management for a neural network system

A neural network runs a known input data set using an error free power setting and using an error prone power setting. The differences in the outputs of the neural network using the two different power settings determine a high level error rate associated with the output of the neural network using the error prone power setting. If the high level error rate is excessive, the error prone power setting is adjusted to reduce errors by changing voltage and/or clock frequency utilized by the neural network system. If the high level error rate is within bounds, the error prone power setting can remain allowing the neural network to operate with an acceptable error tolerance and improved efficiency. The error tolerance can be specified by the neural network application.

Kegel, Andrew G.↗

High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP): Design Guidelines and Specifications for DC Distribution-Based Charging Hub

Managed under U.S. Department of Energy (DOE)-funded EVs@Scale Consortium, High-Power Electric Vehicle Charging Hub Integration Platform (eCHIP) project aims to design and develop a high-power, interoperable charging experimental platform to research, develop, and demonstrate the integration and control approaches for a DC distribution-based high-power charging (HPC) system. The eCHIP project addresses the crucial need to design and validate efficient, low-cost, reliable, and interoperable solutions for DC-coupled charging hub ('DC hub' for short). This report explains the design, development, and implementation process of the experimental platform for the DC hub. The utilization of DC distribution holds significant potential for enhancing the operation of an HPC station architecture. However, there are challenges establishing the DC hub, including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products as well as novel, in-house designed solutions to evaluate different use cases at rated power and voltage levels.

33 ADVANCED PROPULSION SYSTEMS↗

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS↗

Heterogeneous network topology management and control

In one aspect, the present disclosure may provide devices or systems configured to receive indications of geographic areas, each corresponding to distribution networks, and determine whether the distribution networks overlap. The processor(s) may also be configured to receive parameter value(s) obtained by a device within one distribution network at a location within an overlapping area, and cause device(s) within another distribution network to modify operation based on the parameter value(s). In another aspect, the present disclosure may provide devices that include a voltage sensor to measure a voltage of a power distribution network at a power consumption location that corresponds to the device. The device may be configured to provide at least one cable service to the power consumption location via a cable television (CATV) distribution network and output an indication the measured voltage value.

Cruickshank, III, Robert Fraser↗

Cooling charge determination for a local thermal management system

A system and method for estimating the state of charge, i.e., the amount of cooling remaining, in a latent heat thermal storage module of a local environmental control system. The local environmental control system stores cooling energy at night by freezing a latent heat phase change material (PCM), and then releasing the stored cooling energy by removing heat from room air flowing through the PCM during the day. Differential temperature sensors are used measure the air temperature drop across the latent thermals storage unit and the fan voltage, which is directly related to fan air flow rate, is sampled. A controller is programmed to determine the charging state from these measurements.

Khalifa, H. Ezzat↗

American-Made Solar Prize: Edgeli Enables DER Integration (CRADA 615) (Final Report)

The purpose of this project was to demonstrate how granular time series data and automated data transformation, and impact assessment tools could speed interconnection approvals for distributed energy resource projects of various types and sizes. Types included community solar, rooftop solar, and EV charging projects. Using software routines to automate the transformation of data (e.g. GIS) to a network database and power flow model then applying scenarios to create hourly (8760) hosting capacity values and voltage and thermal impacts for specific projects, we were able to demonstrate the feasibility of quickly assembling and analyzing key utility data sets for interconnection purposes. The outcomes of this effort will become the foundation for future work that will enhance and encapsulate the software components developed as part of this project, into web services (e.g. APIs) that can be integrated into queue management systems and automate interconnection screening processes.

14 SOLAR ENERGY↗

Generalized and Mechanistic PV Module Performance Prediction From Computer Vision and Machine Learning on Electroluminescence Images

Electroluminescence (EL) imaging of photovoltiac (PV) modules offers high-speed, high-resolution information about device performance, affording opportunities for greater insight and efficiency in module characterization across manufacturing, research and development, and power plant operations and management. Predicting module electrical properties from EL image features is a critical step toward these applications. In this article, we demonstrate quantification of both generalized and performance mechanism-specific EL image features, using pixel intensity-based and machine learning classification algorithms. From EL image features, we build predictive models for PV module power and series resistance, using time-series current-voltage (I-V) and EL data obtained stepwise on five brands of modules spanning three Si cell types through two accelerated exposures: damp heat (DH) (85°C/85% RH) and thermal cycling (TC) (IEC 61215). Overall, 195 pairs of EL images and I-V characteristics were analyzed, yielding 11700 individual PV cell images. A convolutional neural network was built to classify cells by the severity of busbar corrosion with high accuracy (95%). Generalized power predictive models estimated the maximum power of PV modules from EL images with high confidence and an adjusted-R 2 of 0.88, across all module brands and cell types in extended DH and TC exposures. Mechanistic degradation prediction was demonstrated by quantification of busbar corrosion in EL images of three module brands in DH, and subsequent modeling of series resistance using these mechanism-specific EL image features. For modules exhibiting busbar corrosion, we demonstrated series resistance predictive models with adjusted-R 2 of up to 0.73.

14 SOLAR ENERGY↗

LAMP Technical Readiness Evaluation Report

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed in 2023. This included determining corresponding Technical Readiness Levels (TRLs) for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. This revised report includes a summary of the recent design modifications required to meet the project Key Performance Requirements (KPPs), some of which may reduce technical risk to the project. These recent design modifications include: • Further optimization of the low-energy and medium-energy beam transport regions (LEBT and MEBT, respectively), including relocation of various functional elements (ie choppers, kickers, and bunchers). • An additional H - ion source to separate ion-source function based on beam delivery requirements. • A high-repetition-rate pulsed kicker magnet to select/merge the two H ion beams into a common low-energy beam transport. • Modification and further optimization to a more conventional RFQ design. Performance of the RFQ has been optimized to deliver the required three types of beams while meeting the project KPPs. • The addition of a second chopper in the medium-energy beam transport (MEBT) line to reduce the required pulser voltages. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Three subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗