Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage indices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Recent Results From Internal and Very-Near-Field Plasma Diagnostics of a High Specific Impulse Hall Thruster

Floating potential and ion current density measurements were taken on the laboratory model NASA-173Mv2 in order to improve understanding of the physical processes affecting Hall thruster performance at high specific impulse. Floating potential was measured on discharge chamber centerline over axial positions spanning 10 mm from the anode to 100 mm downstream of the exit plane. Ion current density was mapped radially up to 300 mm from thruster centerline over axial positions in the very-near-field (10 to 250 mm from the exit plane). All data were collected using a planar probe in conjunction with a high-speed translation stage to minimize probe-induced thruster perturbations. Measurements of floating potential at a xenon flow rate of 10 mg/s have shown that the acceleration layer moved upstream 3 1 mm when the voltage increased from 300 to 600 V. The length of the acceleration layer was 14 2 mm and was approximately constant with voltage and magnetic field. Ion current density measurements indicated the annular ion beam crossed the thruster centerline 163 mm downstream of the exit plane. Radial integration of the ion current density at the cathode plane provided an estimate of the ion current fraction. At 500 V and 5 mg/s, the ion current fraction was calculated as 0.77.

Hofer, Richard R.↗

Flux focusing eddy current probe

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. The maximum sensor output is obtained when positioned symmetrically above the crack. Hence, by obtaining the position of the maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. The accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output which results in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip which enables the region for searching to be clearly defined. Under low frequency operation, material thinning due to corrosion damage causes an incomplete shielding of the pick-up coil. The low frequency output voltage of the probe is therefore a direct indicator of the thickness of the test sample.

Simpson, John W.↗

Design and Varactors: Operational Considerations. A Reliability Study for Robust Planar GaAs

Preliminary conclusions include: Limits for reverse currents cannot be set. Based on current data we want to avoid any reverse bias current. We know 1 micro-A is too high. Leakage current gets suppressed when operated at 120K. Migration and verification: a) Reverse Bias Voltage will be limited; b) Health check with I/V curve: 1) Minimal reverse voltage shall be x0.75 of the calculated voltage breakdown Vbr; 2) Degradation of the Reverse Bias voltage at given current will be used as indication of ESD incidents or other Damages (high RF power, heat); 3) Calculation of diodes parameter to verify initial health check result in forward direction. RF output power starts to degrade when diode I/V curve is very strongly degraded only. Experienced on 400GHz doubler and 200GHz doubler

THz frequencies↗

Humidity Testing of PME and BME Ceramic Capacitors with Cracks

Cracks in ceramic capacitors are one of the major causes of failures during operation of electronic systems. Humidity testing has been successfully used for many years to verify the absence of cracks and assure quality of military grade capacitors. Traditionally, only precious metal electrode (PME) capacitors were used in high reliability applications and the existing requirements for humidity testing were developed for this type of parts. With the advance of base metal electrode (BME) capacitors, there is a need for assessment of the applicability of the existing techniques for the new technology capacitors. In this work, variety of different PME and BME capacitors with introduced cracks were tested in humid environments at different voltages and temperatures. Analysis of the test results indicates differences in the behavior and failure mechanisms for BME and PME capacitors and the need for different testing conditions.

reliability↗

Insulator edge voltage gradient effects in spacecraft charging phenomena

Insulating surfaces on geosynchronous satellites have been charged by geomagnetic substorms to a point where discharges occur. The electromagnetic pulses from these discharges couple into satellite electronic systems disrupting operations. Laboratory tests conducted on insulator charging have indicated that discharges appear to be initiated at insulator edges where voltage gradients can exist. An experimental investigation has been conducted to measure edge voltage gradients on silvered Teflon samples as they are charged by monoenergetic electron beams. It has been found that the surface voltage at insulator edges can be approximated by an exponential expression based on an electron current density balance. Using this expression at known breakdown conditions results in a discharge voltage gradient down the insulator edge to ground of about 150,000 V/cm.

Stevens, N. J.↗

Experimentally Determined Plasma Parameters in a 30 cm Ion Engine

Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.

near grid plasma↗

Insulator edge voltage gradient effects in spacecraft charging phenomena

Insulating surfaces on geosynchronous satellites were charged by geomagnetic substorms to a point where discharges occur. The electromagnetic pulses from these discharges couple into satellite electronic systems disrupting operations are examined. Laboratory tests conducted on insulator charging have indicated that discharges appear to be initiated at insulator edges where voltage gradients can exist. An experimental investigation was conducted to measure edge voltage gradients on silvered Teflon samples as they are charged by monoenergetic electron beams. It was found that the surface voltage at insulator edges can be approximated by an exponential expression based on an electron current density balance.

Stevens, N. J.↗

Heterogeneous network topology management and control

In one aspect, the present disclosure may provide devices or systems configured to receive indications of geographic areas, each corresponding to distribution networks, and determine whether the distribution networks overlap. The processor(s) may also be configured to receive parameter value(s) obtained by a device within one distribution network at a location within an overlapping area, and cause device(s) within another distribution network to modify operation based on the parameter value(s). In another aspect, the present disclosure may provide devices that include a voltage sensor to measure a voltage of a power distribution network at a power consumption location that corresponds to the device. The device may be configured to provide at least one cable service to the power consumption location via a cable television (CATV) distribution network and output an indication the measured voltage value.

Cruickshank, III, Robert Fraser↗

The Effect of Dopant Concentration and Annealing Treatments on N-Type Iodine Doped CdTe

We report properties of highly conducting n-type cadmium telluride single crystals doped with iodine (CdTe:I). These crystals were grown with dopant concentrations in the range of 10^17 cm-3 to 10^19 cm-3 by Modified Vertical Bridgman (MVB) melt growth. Post-growth dopant activation, including Cd annealing, Te annealing, and rapid thermal annealing (RTA), was applied to improve free carrier density. The structural, optical, and electrical properties were analyzed by Glow Discharge Mass Spectroscopy (GDMS), X-ray photoelectron spectroscopy (XPS), X-ray diffraction (XRD), Photoluminescence Spectroscopy (PL), optical absorption, Hall measurements, Capacitance-Voltage (CV) measurements, and time-resolved photoluminescence (TRPL). The results indicate that Cd annealing is the most effective activation method to get 100% donor activation (n is approximately 2 x 10^18 cm-3), which is close to the room temperature solubility limit of iodine. This leads to the lowest resistivity and the highest mobility. Moreover, this data suggests a potential role of Cd vacancy-related defects on electrical self-compensation.

annealing↗

A Data-Driven Global Sensitivity Analysis Framework for Three-Phase Distribution System with PVs

Global sensitivity analysis (GSA) of distribution systems with respect to stochastic PV and load variations plays an important role in designing optimal voltage control schemes. This paper proposes a data-driven framework for GSA of distribution systems. In particular, two representative surrogate modeling-based approaches are developed, including the traditional Gaussian process-based and the analysis of variance (ANOVA) kernel ones. The key idea is to develop a surrogate model that captures the hidden global relationship between voltage and real and reactive power injections from the historical data. With the surrogate model, the Sobol indices can be conveniently calculated through either the sampling-based method or the analytical method to assess the global sensitivity of voltage to variations of PV and load power injections. The sampling-based method approximates the Sobol indices using Monte Carlo simulations while the analytical method calculates them by resorting to the ANOVA expansion framework. Comparison results with other model-based GSA methods on the unbalanced three-phase IEEE 37-bus and 123-bus distribution systems show that the proposed framework can achieve much higher computational efficiency with negligible loss of accuracy. The results on a real 240-node distribution system using actual smart meter data further validate the feasibility and scalability of the proposed framework.

14 SOLAR ENERGY↗

Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

NASCAP modelling of high-voltage power system interactions with space charged-particle environments

A simple space power system operating in geosynchronous orbit was analyzed. This system consisted of two solar array wings and a central body. Each solar array wing was considered to be divided into three regions operating at 2000 volts. The center body was considered to be an electrical ground with the array voltages both positive and negative relative to ground. The system was analyzed for both a normal environment and a moderate geomagnetic substorm environment. Initial results indicate a high probability of arcing at the interconnects on the negative operating voltage wing. The dielectric strength of the substrate may be exceeded giving rise to breakdown in the bulk of the material. The geomagnetic substorm did not seem to increase the electrical gradients at the interconnects on the negative operating voltage wing but did increase the gradients on the positive operating voltage wing which could result in increased coupling current losses.

Stevens, N. J.↗

Characteristics and mathematical modeling of apple slice drying in an electrohydrodynamic system with a needle‐plate electrode

Abstract The drying of apple slices in an electrohydrodynamic (EHD) system with a needle‐plate electrode was characterized and mathematically modeled at voltages of 30, 40, and 50 kV and with distances between needles of 5, 6, and 7 cm. The results showed that the drying rate, effective water diffusion coefficient, and rehydration ratio of the apple slices, and specific energy consumption of drying, all increased with increasing voltage. Initially, there was a period when the drying rate was approximately constant in the low‐voltage EHD, but not in the high voltage conditions. At the same voltage, the drying rate was highest when the distance between needles was 6 cm. The voltage and distance between needles had a significant ( p < .05) interactive effect on the effective water diffusion coefficient and specific energy consumption, but not on the rehydration ratio. General mathematical models for drying can be used to represent the drying behavior of apple slices. The Midilli and Kucuk model and the Logarithmic model had the best fits, with correlation coefficients of 0.998803 and 0.998267, respectively. Predictive functions for the moisture ratio of apple slices based on voltage and distance between needles were established and verified. The results indicated that the Logarithmic model could more accurately predict the moisture ratio of apple slices dried using the EHD method. Practical Applications As a new drying technology, electrohydrodynamic (EHD) drying has unequaled advantages. According to the results, using the appropriate voltage and distance between needles improves not only drying efficiency, but also the rehydration ratio of apple slices, which reflects the quality of dried products. The Logarithmic model can accurately predict the EHD drying behavior of apple slices, which is of great significance in optimizing actual production.

Li, Bowen↗

Identification of Recombination Losses in CdSe/CdTe Solar Cells from Spectroscopic and Microscopic Time-Resolved Photoluminescence

Due to the lowest-cost and best reliability, CdTe solar cells are the leading thin-film photovoltaic technology. Increasing open-circuit voltage by reducing recombination represents the most promising path toward further improvements. Analysis is needed to identify limitations that cause efficiency losses. To achieve this goal for Cu-doped CdSe/CdTe solar cells, time-resolved spectroscopy and microscopy are developed and applied. Recombination lifetimes and radiative efficiency identify that defect-mediated recombination is the dominant voltage loss mechanism. When carrier lifetimes are averaged over many crystalline grains, they increase from 180 to 430 ns when Al2O3 is applied to the back contact. The quasi-Fermi-level splitting correspondingly increases from 880–905 to 906–931 mV, indicating a pathway to overcome the long-standing 900 mV voltage limitation. However, the dominant recombination losses are attributed to the absorber bulk. From microscopic carrier lifetime measurements, it is identified that space charge fields due to charged grain boundaries (GBs) lead to recombination in the CdTe absorber bulk. At high injection, GB space charge fields are screened, but that occurs above 1 Sun excitation conditions. Alloying with selenium in the near-interface CdSeTe absorber region reduces GB losses and is identified as one of the factors leading to high radiative and power conversion efficiency.

14 SOLAR ENERGY↗

Electro-Optic Lightning Detector

Electric field measurements are fundamental to the study of thunderstorm electrification, thundercloud charge structure, and the determination of the locations and magnitudes of charges deposited by lightning. Continuous field observations can also be used to warn of impending electrical hazards. For example, the USAF Eastern Range (ER) and NASA Kennedy Space Center (KSC) in Florida currently operate a ground-based network of electric field mill sensors to warn against lightning hazards to space vehicle operations/launches. The sensors provide continuous recordings of the ambient field. Others investigators have employed flat-plate electric field antennas to detect changes In the ambient field due to lightning. In each approach, electronic circuitry is used to directly detect and amplify the effects of the ambient field on an exposed metal conductor (antenna plate); in the case of continuous field recordings, the antenna plate is alternately shielded and unshielded by a grounded conductor. In this work effort, an alternate optical method for detecting lightning-caused electric field changes is Introduced. The primary component in the detector is an anisotropic electro-optic crystal of potassium di-hydrogen phosphate (chemically written as KH2PO4 (KDP)). When a voltage Is placed across the electro-optic crystal, the refractive Indices of the crystal change. This change alters the polarization state of a laser light beam that is passed down the crystal optic axis. With suitable application of vertical and horizontal polarizers, a light transmission measurement is related to the applied crystal voltage (which in turn Is related to the lightning caused electric field change). During the past two years, all critical optical components were procured, assembled, and aligned. An optical housing, calibration set-up, and data acquisition system was integrated for breadboard testing. The sensor was deployed at NASA Marshall Space Flight Center (MSFC) in the summer of 1998 to collect storm data. Because solid-state technology is used, future designs of the sensor will be significantly scaled down In physical dimension and weight compared to the present optical breadboard prototype. The use of fiber optics would also provide significant practical improvements.

Koshak, William J.↗

Pulsed laser illumination of photovoltaic cells

In future space missions, free electron lasers (FEL) may be used to illuminate photovoltaic receivers to provide remote power. Both the radio-frequency (RF) and induction FEL produce pulsed rather than continuous output. In this work we investigate cell response to pulsed laser light which simulates the RF FEL format. The results indicate that if the pulse repetition is high, cell efficiencies are only slightly reduced compared to constant illumination at the same wavelength. The frequency response of the cells is weak, with both voltage and current outputs essentially dc in nature. Comparison with previous experiments indicates that the RF FEL pulse format yields more efficient photovoltaic conversion than does an induction FEL format.

Yater, Jane A.↗

Pulsed laser illumination of photovoltaic cells

In future space missions, free electron lasers (FEL) may be used to illuminate photovoltaic array receivers to provide remote power. Both the radio-frequency (RF) and induction FEL provide FEL produce pulsed rather than continuous output. In this work we investigate cell response to pulsed laser light which simulates the RF FEL format. The results indicate that if the pulse repetition is high, cell efficiencies are only slightly reduced compared to constant illumination at the same wavelength. The frequency response of the cells is weak, with both voltage and current outputs essentially dc in nature. Comparison with previous experiments indicates that the RF FEL pulse format yields more efficient photovoltaic conversion than does an induction FEL pulse format.

Yater, Jane A.↗

Characterization of Open Circuit Voltage and Capacity as a Function of Time

It is noted from the data presented that Li/BCX cells lose approximately 8% of their rated capacity in the first 2 months of storage. After this period of time, little difference is noted in the average realized capacity; however, a significant increase in the range is observed. Over the same period of time the OCV falls at a rate of 0.02V per 1,000 hours. After a period of 8,000 hours the OCV appears stabilize at a value of approximately 3.75V. This may be related to changes in Cl2 concentration due to self-discharge or other reactions. These data indicate that no correlation exists between the reduced open circuit voltage and the realized capacity.

Krehl, P. W.↗