Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

Power Factor revisited

Power factor is a term whose value can be found by dividing the power in a load to the product of the voltage and the current. It has been used as a rule of thumb to estimate the cost of the losses incurred in delivering reactive power. But it has been extremely troublesome. The same load might be penalized by some definitions, and might not by others. That is still the situation today. There have been two efforts at solution. In 1919 a committee of experts was formed to solve the problem of its definition. The effort did not succeed at producing a definition; two alternatives were recommended in the committee’s final report, but both were adopted. In 2010, IEEE issued Standard 1459 to give definitions. In this standard, definitions of power factor appear under no less than seven different headings. The problem demands solution. The matter is of considerable economic importance to power producers, consumers, and instrument makers. This paper examines the history of the topic, and explores reasons for the difficulty of definition in terms of measurement theory. It is shown that power factor is not suited to purpose. In fact, no definition can exist that will define power factor usefully for its intended economic purpose. Two alternatives are proposed.

power factror, definitions, measurement theory, IE↗

Research, Development and Fabrication of Lithium Solar Cells

This report continues studies on cells made with low temperature (<400degC) single-cycle, lithium diffusion schedules. Measurements of concentration of lithium at the back surface showed that C(sub S) changes with time consisting of a build-up to a maximum value (above 10(exp 17) cm(exp -3)) with gradual decrease at longer diffusion times. Using the estimated C(sub S) values, theoretical lithium profiles were calculated. The calculated concentration near the PN junction was higher than those measured by the capacitance voltage (C-V) technique. The calculated concentration gradients were one-seventh of those measured by C-V methods. Both the concentration and its gradient were proportional to C(sub S). Estimates of C(sub S) obtained by extrapolating from C-V measured values of concentration and gradient near the PN junction, showed a decrease in C(sub S) for longer diffusion times. This fact supported the trend observed in Shipment C-13, where,, at longer times, the spread in values of V(sub oc), lithium concentration, and gradient became greater. The general conclusion was that the I-V characteristics were well controlled, with good cell output, but for longer diffusion times the lithium concentration gradient could have wider spread. The work described has led to greater insight into the lithium distribution dependence on the surface conditions. The surface conditions could be changed by varying the method used to apply lithium. Vacuum evaporation of lithium shows promise, and another exhaustive test of this method is in progress. Shipment C-13 is summarized, and the succeeding lots (C-14, C-15) are described. It is felt that improved monitoring of cell properties is at hand, and that the control of cell fabrication processes has advanced to where the effects of subtle differences in lithium distribution can now be seen. Evaluation is continuing on the best method to scale up the fabrication steps. A different sequence of fabrication is planned for Shipments C-14 and C-15.

Iles, Peter A.↗

Diminiode thermionic conversion with 111-iridium electrodes

Preliminary data indicating thermionic-conversion potentialities for a 111-iridium emitter and collector spaced 0.2 mm apart are presented. These results comprise output densities of current and of power as functions of voltage for three sets of emitter, collector, and reservoir temperatures: 1553, 944, 561 K; 1605, 898, 533 K; and 1656, 1028, 586 K. For the 1605 K evaluation, estimates produced work-function values of 2.22 eV for the emitter and 1.63 eV for the collector with a 2.0-eV barrier index (collector work function plus interelectrode voltage drop) corresponding to the maximum output of 5.5 W/sq cm at 0.24 volt. The current, voltage curve for the 1656 K 111-iridium diminiode yields a 6.2 W/sq cm maximum at 0.25 volt and is comparable with the 1700 K envelope for a diode with an etched-rhenium emitter and a 0.025-mm electrode gap made by TECO and evaluated by NASA.

Koeger, E. W.↗

Joint Estimation of Topology and Injection Statistics in Distribution Grids with Missing Nodes

Optimal operation of distribution grid resources relies on accurate estimation of its state and topology. Practical estimation of such quantities is complicated by the limited presence of real-time meters. This article discusses a theoretical framework to jointly estimate the operational topology and statistics of injections in radial distribution grids under limited availability of nodal voltage measurements. In particular, we show that our proposed algorithms are able to provably learn the exact grid topology and injection statistics at all unobserved nodes as long as they are not adjacent. The algorithm design is based on novel ordered trends in voltage magnitude fluctuations at node groups, that are independently of interest for radial physical flow networks. The complexity of the designed algorithms is theoretically analyzed and their performance is validated using both linearized and nonlinear ac power flow samples in test distribution grids.

97 MATHEMATICS AND COMPUTING↗

Effect of electrode rinse solutions on the electrodialysis of concentrated salts

The data presented indicate that modest attention to the chemistry of the electrode rinse solution can yield as much as 56% improvement in process efficiency. When operating electrodialysis (ED) with salt concentrations greater than 10,000 mg/l (as NaCl) the amperage can be relatively high even at low voltages. To maximize the overall rate of ion transport from diluate to concentrate, there is a need to minimize resistances in the electrode cells since these can represent as much as 30% of the total resistances in the entire process and in this particular ED unit, represented resistance roughly equivalent to that within the membrane stack. This work describes the performance of a 10-cell pair, 200 cm 2 (0.02 m 2 ) per membrane, pilot ED unit operated in batch mode at 5 V potential. The feedstock to the stack was varied from 0.5% to 6% NaCl. Results from Volt-amp profiles (2.0–15 V) were used as the rationale for choosing the preferred electrode rinse solution, 90 g/l (kg/m 3 ) disodium sulfate at pH 12.5. The recommended solution of 30 g/l (kg/m 3 ) disodium sulfate at neutral pH was tested against stronger solutions (60, 90, and 120 g/l (kg/m 3 ) disodium sulfate) at neutral pH and with 1 g/l (kg/m 3 ) sodium hydroxide added to yield solutions at pH 12.5. There were stark differences in the performance of the ED unit between the solutions at pH 7 and those at pH 12.5. The slopes of the Volt-amp profiles improved indicating less resistance to ion flow at pH 12.5. Most of the difference can be attributed to the greater conductivity of sodium hydroxide compared to disodium sulfate, where even a modest addition of 1 g/l (kg/m 3 ) sodium hydroxide increased the conductivity of the solution between 8 and 20% depending on the concentration of disodium sulfate. Most notably, the initiation voltage was 2.39 ± 0.08 V with solutions at pH 7 and 1.99 V ± 0.04 V when the rinse solutions were around pH 12.5, a difference of around 0.42 V. Since the full batch runs were performed at 5.0 V, this 0.42 V differential represented a loss of 8% in process efficiency. A series of tests showed a shift in initiation voltage occurred between pH 11.5 and 12.5. Nernst equations for water electrolysis are coupled with a simple flux model that estimates the concentration of hydroxide and hydronium ions at the electrode surfaces. This model indicates that the potential demanded by the electrodes is directly linked to the current. Furthermore, there is a steep drop in the potential demanded by the anode when there is sufficient hydroxide available to generate oxygen from hydroxide as opposed to generation from water. The voltage demand is minimal at pH 12.5 and reflective of the reference standard voltage (just over 1.23 V predicted at 0.1 amps). However, the flux model predicts that the voltage demanded by the electrodes at pH 7 is 1.61 V at 0.1 amps (the lowest amperage measurable with the power pack). In conclusion, comparing this result to the reference standard (E 0 = -1.23 V) yields a satisfactory explanation for the observed difference below reference standard of 0.42 V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sub‐0.6 eV Inverted Metamorphic GaInAs Cells Grown on Inp and GaAs Substrates for Thermophotovoltaics and Laser Power Conversion

Abstract Inverted metamorphic Ga 0.3 In 0.7 As photovoltaic converters with sub‐0.60 eV bandgaps grown on InP and GaAs are presented. Threading dislocation densities are 1.3 ± 0.6 × 10 6 and 8.9 ± 1.7 × 10 6 cm −2 on InP and GaAs, respectively. The devices generate open‐circuit voltages of 0.386 and 0.383 V, respectively, under irradiance producing a short‐circuit current density of ≈10 A cm −2 , yielding bandgap‐voltage offsets of 0.20 and 0.21 V. Power and broadband reflectance measurements are used to estimate thermophotovoltaic (TPV) efficiency. The InP‐based cell is estimated to yield 1.09 W cm −2 at 1100 °C versus 0.92 W cm −2 for the GaAs‐based cell, with efficiencies of 16.8 versus 9.2%. The efficiencies of both devices are limited by sub‐bandgap absorption, with power weighted sub‐bandgap reflectances of 81% and 58%, respectively, the majority of which is assumed to occur in the graded buffers. The 1100 °C TPV efficiencies are estimated to increase to 24.0% and 20.7% in structures with the graded buffer removed, if previously demonstrated reflectance is achieved. These devices also have application to laser power conversion in the 2.0–2.3 µm atmospheric window. Peak laser power converter efficiencies of 36.8% and 32.5% are estimated under 2.0 µm irradiances of 1.86 and 2.81 W cm −2 , respectively.

14 SOLAR ENERGY↗

Coordinated Inverter Control to Increase Dynamic PV Hosting Capacity: A Real-Time Optimal Power Flow Approach

High penetrations of distributed photovoltaics (PV) could cause adverse grid impacts, such as voltage violations. The recent development in inverter technologies provides the opportunity to develop control systems to realize effective PV governance and thus to improve dynamic PV hosting capacity for distribution grids. In this paper, a novel distributed energy resource management system (DERMS) solution is proposed by adopting the real-time optimal power flow (OPF) approach for coordinated control of the distributed PV inverters. The proposed approach eliminates the dependence on load knowledge via measurement feedback correction, and it can be implemented in real time. One challenge is that the technique is sensitive to the data availability and integrity of voltage measurements. Therefore, a decentralized DERMS approach is developed by leveraging the concepts of state estimation. The framework and the effectiveness of the solution approach are numerically demonstrated on a real distribution feeder in Southern California.

14 SOLAR ENERGY↗

Performance of a neutralizer for electron bombardment thruster

Results of the SERT II flight indicate that the hollow cathode neutralizer not only represents a power and propellant weight penalty but can be a contributing cause to accelerator grid erosion. Tests with a 30-cm diameter thruster show that a neutralizer position of approximately 9 cm axially downstream of the accelerator grid and approximately 9 cm radially away from the outer edge of the accelerator grid and pointing parallel to the thruster axis provides the best overall performance. The estimated grid wear rate was less than 0.08 mm in 10,000 hours. The coupling voltage was approximately 17 volts at a neutralizer flow rate of 22 equivalent milliamperes of mercury and a beam current of 1.5 amperes. Neutralizer power was 31 watts and the effect of neutralizer flow on overall propellant utilization efficiency is a 1.2 percentage point reduction at a thruster utilization efficiency of 90 percent. The neutralizer position defined in tests with a 30 cm thruster was tested with a 15 cm SERT II thruster. When the neutralizer was relocated further downstream with this different orientation, accelerator impingement current due to neutralizer operation was reduced by approximately a factor of seven and was nearly independent of neutralizer operation.

Bechtel, R. T.↗

Performance of a neutralizer for electron bombardment thruster.

Results of the SERT II flight indicate that the hollow cathode neutralizer not only represents a power and propellant weight penalty but can be a contributing cause to accelerator grid erosion. Tests with a 30-cm diameter thruster have shown that a neutralizer position of approximately 9 cm axially downstream of the accelerator grid and approximately 9 cm radially away from the outer edge of the accelerator grid and pointing parallel to the thruster axis provides the best overall performance. The estimated grid wear rate was less than 0.08 mm in 10,000 hr. The coupling voltage (neutralizer to beam voltage) was approximately 17 volts at a neutralizer flow rate of 22 equivalent milliamperes of mercury and a beam current of 1.5 amperes. Neutralizer power (excluding heaters) was 31 watts and the effect of neutralizer flow on overall propellant utilization efficiency is a 1.2 percentage point reduction at a thruster utilization efficiency of 90 percent.

Bechtel, R. T.↗

Observations from Long-Term Performance Monitoring of the TOPEX Radar Altimeter

From its August 1992 launch to the present, we have performed performance analysis and engineering assessment for the TOPEX radar altimeter. We continually update databases containing: (1) on-board engineering parameters such as temperatures, voltages, and currents; (2) internal calibration mode indications of bias changes in range and power estimates; and (3) global over-ocean averages of geophysical quantities such as significant waveheight (SWH) and ocean surface radar backscattering cross-section (sigmaO). For some time now we have seen an apparent increase in the TOPEX cycle-average SWH, amounting now to an increase of about 10% from our earlier mission value of about 2.8 m. Recently several investigators have reported that the TOPEX SWH is increasing relative to ERS-2 and to ocean buoy measurements. We examined the past six years of waveform data from an internal calibration mode (Cal 1) which samples the altimeter's point target response (ptr), and found that the ptr sidelobes are apparently greater now than at start of mission. Modeling studies indicate that the sidelobe enhancement can account for most of the increase in the TOPEX SWH estimate; that is, the SWH increase is not real but result of some drift within the altimeter. Our modeling indicates that the TOPEX range estimates will change less than a centimeter for ptr changes seen to date. An approximate recipe for correcting the TOPEX SWH values will be made available on our web site (http://topex.wffnasa.gov/). We emphasize that a radar altimeter is a complex system requiring continuing calibration and monitoring throughout its entire lifetime.

Hayne, G. S.↗

Hierarchical Statistical 3D ' Atomistic' Simulation of Decanano MOSFETs: Drift-Diffusion, Hydrodynamic and Quantum Mechanical Approaches

When MOSFETs are scaled to deep submicron dimensions the discreteness and randomness of the dopant charges in the channel region introduces significant fluctuations in the device characteristics. This effect, predicted 20 year ago, has been confirmed experimentally and in simulation studies. The impact of the fluctuations on the functionality, yield, and reliability of the corresponding systems shifts the paradigm of the numerical device simulation. It becomes insufficient to simulate only one device representing one macroscopical design in a continuous charge approximation. An ensemble of macroscopically identical but microscopically different devices has to be characterized by simulation of statistically significant samples. The aims of the numerical simulations shift from predicting the characteristics of a single device with continuous doping towards estimating the mean values and the standard deviations of basic design parameters such as threshold voltage, subthreshold slope, transconductance, drive current, etc. for the whole ensemble of 'atomistically' different devices in the system. It has to be pointed out that even the mean values obtained from 'atomistic' simulations are not identical to the values obtained from continuous doping simulations. In this paper we present a hierarchical approach to the 'atomistic' simulation of aggressively scaled decanano MOSFETs. A full scale 3D drift-diffusion'atomostic' simulation approach is first described and used for verification of the more economical, but also more restricted, options. To reduce the processor time and memory requirements at high drain voltage we have developed a self-consistent option based on a thin slab solution of the current continuity equation only in the channel region. This is coupled to the Poisson's equation solution in the whole simulation domain in the Gummel iteration cycles. The accuracy of this approach is investigated in comparison with the full self-consistent solution. At low drain voltage only single solution of the nonlinear Poisson equation is sufficient to extract the current with satisfactory accuracy. A pilot version of a hydrodynamic 'atomistic' simulator has been developed in order to study the effect of the nonequilibrium, non local transport in decanano MOSFETs on the random dopant induced current fluctuations. For the first time we have also applied the density gradient approach in 3D to investigate the effect of the quantum confinement on the threshold voltage fluctuations. The developed 'atomistic' simulation techniques have been applied to study various fluctuation resistant MOSFET architectures including epitaxial and delta doped devices.

Asenov, Asen↗

Characterization of MgB2 Superconducting Hot Electron Bolometers

Hot-Electron Bolometer (HEB) mixers have proven to be the best tool for high-resolution spectroscopy at the Terahertz frequencies. However, the current state of the art NbN mixers suffer from a small intermediate frequency (IF) bandwidth as well as a low operating temperature. MgB2 is a promising material for HEB mixer technology in view of its high critical temperature and fast thermal relaxation allowing for a large IF bandwidth. In this work, we have fabricated and characterized thin-film (approximately 15 nanometers) MgB2-based spiral antenna-coupled HEB mixers on SiC substrate. We achieved the IF bandwidth greater than 8 gigahertz at 25 degrees Kelvin and the device noise temperature less than 4000 degrees Kelvin at 9 degrees Kelvin using a 600 gigahertz source. Using temperature dependencies of the radiation power dissipated in the device we have identified the optical loss in the integrated microantenna responsible as a cause of the limited sensitivity of the current mixer devices. From the analysis of the current-voltage (IV) characteristics, we have derived the effective thermal conductance of the mixer device and estimated the required local oscillator power in an optimized device to be approximately 1 microwatts.

Superconducting Devices↗

Experimentally Determined Plasma Parameters in a 30 cm Ion Engine

Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.

near grid plasma↗

Ground-Support Algorithms for Simulation, Processing, and Calibration of Barnes Static Earth Sensor Measurements: Applications to Tropical Rainfall Measuring Mission Observatory

New algorithms are described covering the simulation, processing, and calibration of penetration angles of the Barnes static Earth sensor assembly (SESA) as implemented in the Goddard Space Flight Center Flight Dynamics Division ground support system for the Tropical Rainfall Measuring Mission (TRMM) Observatory. The new treatment involves a detailed analysis of the measurements by individual quadrants. It is shown that, to a good approximation, individual quadrant misalignments can be treated simply as penetration angle biases. Simple formulas suitable for real-time applications are introduced for computing quadrant-dependent effects. The simulator generates penetration angles by solving a quadratic equation with coefficients uniquely determined by the spacecraft's position and the quadrant's orientation in GeoCentric Inertial (GCI) coordinates. Measurement processing for attitude determination is based on linearized equations obtained by expanding the coefficients of the aforementioned quadratic equation as a Taylor series in both the Earth oblateness coefficient (alpha approx. 1/150) and the angle between the pointing axis and the geodetic nadir vector. A simple formula relating a measured value of the penetration angle to the deviation of the Earth-pointed axis from the geodetic nadir vector is derived. It is shown that even near the very edge of the quadrant's Field Of View (FOV), attitude errors resulting from quadratic effects are a few hundredths of a degree, which is small compared to the attitude determination accuracy requirement (0.18 degree, 3 sigma) of TRMM. Calibration of SESA measurements is complicated by a first-order filtering used in the TRMM onboard algorithm to compute penetration angles from raw voltages. A simple calibration scheme is introduced where these complications are avoided by treating penetration angles as the primary raw measurements, which are adjusted using biases and scale factors. In addition to three misalignment parameters, the calibration state vector contains only two average penetration angle biases (one per each pair of opposite quadrants) since, because of the very narrow sensor FOV (+/- 2.6 degrees), differences between biases of the penetration angles measured by opposite quadrants cannot be distinguished from roll and pitch sensor misalignments. After calibration, the estimated misalignments and average penetration angle biases are converted to the four penetration angle biases and to the yaw misalignment angle. The resultant biases and the estimated scale factors are finally used to update the coefficients necessary for onboard computations of penetration angles from measured voltages.

Natanson, G. A.↗

Inverter Reliability Estimation for Advanced Inverter Functionality

In the near future, grid operators are expected to regularly use advanced distributed energy resource (DER) functions, defined in IEEE 1547-2018, to perform a range of grid-support operations. Many of these functions adjust the active and reactive power of the device through commanded or autonomous modes, which will produce new stresses on the grid-interfacing power electronics components, such as DC/AC inverters. In previous work, multiple DER devices were instrumented to evaluate additional component stress under multiple reactive power setpoints. We utilize quasi-static time-series simulations to determine voltage-reactive power mode (volt-var) mission profile of inverters in an active power system. Mission profiles and loss estimates are then combined to estimate the reduction of the useful life of inverters from different reactive power profiles. It was found that the average lifetime reduction was approximately 0.15% for an inverter between standard unity power factor operation and the IEEE 1547 default volt-var curve based on thermal damage due to switching in the power transistors. For an inverter with an expected 20-year lifetime, the 1547 volt-var curve would reduce the expected life of the device by 12 days. This framework for determining an inverter's useful life from experimental and modeling data can be applied to any failure mechanism and advanced inverter operation.

component degradation↗

High Impedance Fault Detection Through Quasi-Static State Estimation: A Parameter Error Modeling Approach

This paper presents a model for detecting high impedance faults using parameter error modeling and a two step per-phase weighted-least squares state estimation process. The proposed scheme leverages the use of Phasor Measurement Units and synthetic measurements to identify per-phase power flow and injection measurements which indicate a parameter error through ?2 Hypothesis Testing applied to the composed measurement error. Although current and voltage waveforms are commonly analyzed for high-impedance fault detection, wide area power flow and injection measurements, which are already inherent to the state estimation process, also show promise for real-world high-impedance fault detection applications. The error distributions after detection share the measurement function error spread observed in proven parameter error diagnostics and can be applied to high-impedance fault identification. Further, this error spread across measurement functions related to the fault will be clearly discerned from measurement error. Case studies are performed on the IEEE 33-Bus Distribution System along with the proposed model in Simulink.

Cooper, Austin↗