Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage decay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

258 records · Page 15

A flexible test facility for liquid xenon detector development

As liquid xenon time projection chambers scale to ever-larger sizes, so too do the engineering challenges they pose. Here, we describe a large, flexible, multipurpose test facility capable of supporting the development of a number of key aspects of liquid xenon detector systems. Example applications of this facility include characterization of large-area light and charge sensor arrays, tests of xenon purification techniques and materials compatibility, and investigations into high-voltage phenomena. This facility uses an automated and remotely monitored cryo-cooling system based on immersion of the test chamber in a liquid bath rather than conductive coupling, leading to advantages in temperature and pressure stability, as well as increasing required response times in the case of cooling-power loss. Design advantages, operational procedures, and performance of the facility are described, as well as five examples of liquid xenon test chambers that use the facility.

Dark Matter detectors↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

DUNE Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) aims to provide a broad physics program primarily addressed to probing CP violation in the neutrino sector and identifying the neutrino mass hierarchy. The search for proton decay, the observation of supernova neutrino bursts, and the investigation of solar neutrinos represent other additional goals of DUNE experiment, which can be enhanced by the use and the high performances of the Photon Detection System (PDS). Using the technology based on liquid argon Time Projection Chamber (LArTPC), the experiment plans to observe neutrino interactions inside detectors located 1300 km away from the Long Baseline Neutrino Facility (LBNF) at Fermi National Accelerator Laboratory (FNAL), where the neutrinos are produced. The experiment consists of two main parts, respectively the far and near detectors. The far site will comprise four detector modules. The first module is constituted by a vertical drift single-phase LArTPC, while the second module provides a horizontal drift single-phase LArTPC. The configurations of the other modules are still under definition. Neutrino detection in LArTPCs is achieved by identifying the charge and light generated from its interactions with liquid argon. The wire planes of the instrumented anode and the PDS detect these signals, respectively. The PDS in the first two modules, detailed in the present document, uses a modified version of the so-called ARAPUCA technology, named X-ARAPUCA. This system consisting of a highly reflecting box with an entrance window made by dichroic filters and wavelength shifters, creates a trap to detect the VUV (128 nm) scintillation photons. The X-ARAPUCA of the first module is called Supercell, and it has dimensions of 488×100 mm 2 , while Megacell is the second module version, with an active area of 60×60 cm 2 . This latter configuration also represents a significant technological advancement. Since half of the modules are placed on the cathode at high voltage, they are powered and read out using innovative power-over-fiber (PoF) and signal-over-fiber (SoF) technologies. Meanwhile, the other half are installed in a membrane behind the field cage, with a total transparency of around 70%.

Neutrino detectors↗

Stirling Engine Controller

Stirling technology is being developed to replace RTG s (Radioisotope Thermoelectric Generators), more specifically a stirling convertor, which is a stirling engine coupled to a linear alternator. Over the past three decades, the stirling engine has been designed to perform different functions. Stirling convertors have been designed to decrease fuel consumption in automobiles. They have also been designed for terrestrial and space applications. Currently NASA Glenn is using the convertor for space based applications. A stiring converter is a better means of power for deep space mission and "dusty" mission, like the Mars Rovers, than solar panels because it is not affected by dust. Spirit and Opportunity, two Mars rovers currently navigating the planet, are losing their ability to generate electricity because dust is collecting on their solar panels. Opportunity is losing more energy because its robotic arm has a heater with a switch that can not be turned off. The heater is not needed at night, but yet still runs. This generates a greater loss of electricity and in turn diminishes the performance of the rover. The stirling cycle has the potential to provide very efficient conversion of heat energy to electric a1 energy, more so than RTG's. The stirling engine converts the thermal energy produced by the decaying radioisotope to mechanical energy; the linear alternator converts this into electricity. convertor. Since the early 1990's tests have been performed to maximize the efficiency of the stirling converter. Many months, even years, are dedicated to preparing and performing tests. Currently, two stirling convertors #'s 13 and 14, which were developed by Stirling Technology Company, are on an extended operation test. As of June 7th, the two convertors reached 7,500 hours each of operation. Before the convertors could run unattended, many safety precautions had to be examined. So, special instrumentation and circuits were developed to detect off nominal conditions and also safely shutdown the engines. The test will last for a period of 8000 to 9000 hours. Other types of tests that have been performed are: performance mapping, controller development, launch environment, and vibration emissions testing. Currently, the thermo-mechanical system branch is housing a RG-350, a stirling convertor. The convertor was used in previous tests such as a Hall Thruster test, world s first integrated test of a dynamic power system with electric propulsion. Another test performed was to conclude if free piston stirling convertors can be synchronized for vibration balancing, with no thermodynamic or electrical connections and not cause both to shutdown if one failed. The ability to reduce vibration by synchronizing convertor operation but still be able to operate when one partner fails is pertinent in space and terrestrial applications. The convertor is now being brought back into operation and a controller is in the process of being developed. This convertor will be used as a testbed for new controllers. I worked with Mary Ellen Roth on the electric engineering aspects of the RG-350. My main goal was to enhance the data collection process. I worked on different aspects of the RG-350, with a main focus on the engine controller. I drew a schematic of the wire connections in the engine controller, using PCB Express, so that a plan could be devised to connect the power meter properly between the output of the engine and the engine controller. I measured the power using two different instruments: Valhalla Scientific power meter and Ohio Semitronics power measurement device. The convertor is connected to an Agilent 34970A Data Acquisition/Switch Unit, which allows the user to measure, record, and monitor voltage, current, frequency, and temperature. I assisted in preparing the Data Acquisition for general operation. I also helped test a panel of transducers, which will be placed in the rack that powers and monitors the convertor.

Blaze, Gina M.↗

The Quantum Nature of the Neutrino

Over the last 100 years we have learned much about the neutrino, but there remain interesting questions about this weakly interacting particle. In particular, at LLNL we are developing an experiment to measure the quantum nature of the neutrino. The 2015 long range plan recom mended tonne-scale neutrinoless double beta decay experiments as the top new project priority and this experiment will target the quantum nature of the neutrino. The LLNL team is motivated and focused on developing the best technology for this experiment which is a liquid xenon time projection chamber called nEXO. Work on nEXO at LLNL started in 2015 with an LDRD and program development funds to de velop the nEXO concept, publish sensitivity predictions, explore alternatives and risks, and to build a credible project team and this effort is on going. In addition, we received research funding from DOE-SC NP and LLNL manages pre-conceptual R&D for the nEXO collaboration a portion of which is executed at LLNL. LLNL has a long history of building large projects, science projects and time projection chambers, but nEXO is in fact the first project of this scale that LLNL is prepared to lead for DOE-SC NP. We have the tools, skills, people and motivation to make nEXO a reality. The current program devel opment dollars are used to prepare the nEXO concept for down select and CD1. These internal LLNL dollars pay for a number of things including project staff to organize the nEXO collaboration for the various reviews, to develop the draft plans and structure to manage the project as well as setting up external advisory committees. The DOE-SC NP base funding is targeted at simulation and analysis of the nEXO concept in preparation for the down select and refinement of the under standing of the detector as well as scientific effort on the large xenon test stand (LXTS) that will burn down one of the largest risks to the nEXO project. Lastly, LLNL is leading the pre-conceptual R&D effort and managing the funds for the nEXO collaboration. LLNL continues to build the best scientific team for nEXO and this year that includes adding Ethan Bernard to lead the efforts on the LXTS. We will also soon add a new postoc, Samuel Hedges, in the fall to the LLNL nEXO team. The effort this year was influenced by the portfolio review, and there were a number of scientific activities led by LLNL to prepare for this review. In addition, we again took a lead role on the new sensitivity paper as well as publishing a paper based analyzing the effects of skin xenon in nEXO. LLNL leads the software and analysis for the project and we continued work in this area as well. High voltage remains a significant risk for the project and we continue to make progress on the LXTS that will mitigate this risk. Lastly we remain active in looking at how to scale the technology to larger scales, and expect to produce a paper on this topic in the near future.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗