Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visualizing data variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Thermal Stability of RP-2 for Hydrocarbon Boost Regenerative Cooling

A series of tests were performed in the NASA Glenn Research Centers Heated Tube Facility to study the heat transfer and thermal stability behavior of RP-2 under conditions similar to those found in rocket engine cooling channels. It has long been known that hydrocarbon fuels, such as RP-2, can decompose at high temperature to form deposits (coke) which can adversely impact rocket engine cooling channel performance. The heated tube facility provides a simple means to study these effects. Using resistively heated copper tubes in a vacuum chamber, flowing RP-2 was heated to explore thermal effects at a range of test conditions. Wall temperature (850-1050F) and bulk fluid temperature (300-500F) were varied to define thermal decomposition and stability at each condition. Flow velocity and pressure were fixed at 75 fts and 1000 psia, respectively. Additionally, five different batches of RP-2 were tested at identical conditions to examine any thermal stability differences resulting from batch to batch compositional variation. Among these tests was one with a potential coke reducing additive known as 1,2,3,4-Tetrahydroquinoline (THQ). While copper tubes were used for the majority of tests, two exploratory tests were performed with a copper alloy known as GRCop-42. Each tube was instrumented with 15 thermocouples to examine the temperature profile, and carbon deposition at each thermocouple location was determined post-test in an oxidation furnace. In many tests, intermittent local temperature increases were observed visually and in the thermocouple data. These hot spots did not appear to correspond with a higher carbon deposition.

Kleinhenz, Julie E.↗

Statistical Algorithms Accounting for Background Density in the Detection of UXO Target Areas at DoD Munitions Sites

Statistically defensible methods are presented for developing geophysical detector sampling plans and analyzing data for munitions response sites where unexploded ordnance (UXO) may exist. Detection methods for identifying areas of elevated anomaly density from background density are shown. Additionally, methods are described which aid in the choice of transect pattern and spacing to assure with degree of confidence that a target area (TA) of specific size, shape, and anomaly density will be identified using the detection methods. Methods for evaluating the sensitivity of designs to variation in certain parameters are also discussed. Methods presented have been incorporated into the Visual Sample Plan (VSP) software (free at http://dqo.pnl.gov/vsp) and demonstrated at multiple sites in the United States. Application examples from actual transect designs and surveys from the previous two years are demonstrated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Separation Control CFD Validation Test Case: Baseline and Steady Suction - Part 1

Low speed flow separation over a wall-mounted hump, and its control using steady suction, were studied experimentally in order to generate a data set for a workshop aimed at validating CFD turbulence models. The baseline and controlled data sets comprised static and dynamic surface pressure measurements, flow field measurements using Particle Image Velocimetry (PIV) and wall shear stress obtained via oil-film interferometry. In addition to the specific test cases studied, surface pressures for a wide variety of conditions were reported for different Reynolds numbers and suction rates. Stereoscopic PIV and oil-film flow visualization indicated that the baseline separated flow field was mainly two-dimensional. With the application of control, some three-dimensionality was evident in the spanwise variation of pressure recovery, reattachment location and spanwise pressure fluctuations. Part 2 of this paper, under preparation for the AIAA Meeting in Reno 2005, considers separation control by means of zero-efflux oscillatory blowing.

Greenblatt, David↗

ON THE SIX-YEAR PERIOD IN THE RADIAL VELOCITY OF ANTARES A

We examine the century-long historical data and compare it with our new radial-velocity measurements to determine an improved period. We find a period of 2167 {+-} 5 days (5.93 {+-} 0.01 years). Both orbital motion and pulsation are considered as possible causes of the velocity variation. Temperature variations we deduce from line-depth ratios support the pulsation hypothesis. A temperature minimum occurs in 2009, 70 days after the radial-velocity minimum. We deduce a radius change of 19% {+-} 4% from an integration of the radial-velocity curve and predict a visual magnitude variation {approx}0.2 from the radius and temperature variation.

79 ASTRONOMY AND ASTROPHYSICS↗

Continued RXTE Observations of Three Blazars

This project continued (during Cycle 3 of the RXTE mission) weekly observations of the quasars PKS 1510-089 and 3C 454.3 and the BL Lac object OJ 287. The data were analyzed by the PI and his graduate student. In the middle of Cycle 3, the PI changed the mode of observation of 3C 454.3, based on a report from another astronomer that observations with the Rosat satellite had found a strong confusing X-ray source about 45 arcmin away. The RXTE observations, in which the flux was measured while pointing directly at 3C 454.3 and then 15' from 3C 454.3, in the direction away from the confusing source. The flux decreased considerably, and so it appears that nearly all the X-ray flux measured by RXTE comes from the confusing source rather than the quasar. OJ 287 was detected only at one epoch of the Cycle 3 observations. This corresponded to a particularly quiet period for this source, when its flux at other wavebands was also low. From the single epoch of detection, no conclusions can be drawn concerning the general nature of the X-ray emission from this object. In contrast to the other two sources, the results of the observations of PKS 1510-089, when combined with data from cycles 3 and 4, are very interesting. The RXTE (2.4-20 keV) abd 14.5 GHz University of Michigan Radio Astronomy Observatory (UMRAO) light curves through the end of RXTE Cycle 4 are shown for PKS 1510-089. Visual inspection reveals an obvious correlation between the X-ray and 14.5 GHz light curves. While this is as expected in the SSC model in a source with simultaneous mm-wave (the photons thought to be scattered to X-ray energies) and cm-wave variations, the X-ray spectrum is flat ("energy" spectral index alpha = 0.2-0.5, where F (sub v) proportional to v (sup - alpha)) compared with the mm-wave synchrotron spectrum (alpha approximately equal to 0.8). The PI is currently engaged in theoretical work to determine whether this is possible for an SSC model.

Marscher, Alan P.↗

Lidar Measurements of Wind, Moisture and Boundary Layer Evolution in a Dryline During IHOP2002

Variability in the convective boundary layer moisture, wind and temperature fields and their importance in the forecasting and understanding of storms have been discussed in the literature. These variations have been reported in relation to frontal zones, stationary boundaries and during horizontal convective rolls. While all three vary substantially in the convective boundary layer, moisture poses a particular challenge. Moisture or water vapor concentration (expressed as a mass mixing ratio, g/kg), is conserved in all meteorological processes except condensation and evaporation. The water vapor mixing ratio often remains distinct across an air -mass boundary even when the temperature difference is indistinct. These properties make it an ideal choice in visualizing and understanding many of the atmosphere's dynamic features. However, it also presents a unique measurement challenge because water vapor content can vary by more than three orders of magnitude in the troposphere. Characterization of the 3D-distribution of water vapor is also difficult as water vapor observations can suffer from large sampling errors and substantial variability both in the vertical and horizontal. This study presents groundbased measurements of wind, boundary layer structure and water vapor mixing ratio measurements observed by three co-located lidars. This presentation will focus on the evolution and variability of moisture and wind in the boundary layer during a dry line event that occurred on 22 May 2002. These data sets and analyses are unique in that they combine simultaneous measurements of wind, moisture and CBL structure to study the detailed thermal variability in and around clear air updrafts during a dryline event. It will quantify the variation caused by, in and around buoyant plumes and across a dryline. The data presented here were collected in the panhandle of Oklahoma as part of the International BO Project (IHOP-2002), a field experiment that took place over the Southern Great Plains (SGP) of the United States from 13 May to 30 June 2002. The chief goal of IHOP-2002 is to improve characterization of the four-dimensional (4-D) distribution of water vapor and its application to improving the understanding and prediction of convection

Demoz, Belay↗

Plasma parameters and electromagnetic forces induced by the magneto hydro dynamic interaction in a hypersonic argon flow experiment

This work proposes an experimental analysis on the magneto hydro dynamic (MHD) interaction induced by a magnetic test body immersed into a hypersonic argon flow. The characteristic plasma parameters are measured. They are related to the voltages arising in the Hall direction and to the variation of the fluid dynamic properties induced by the interaction. The tests have been performed in a hypersonic wind tunnel at Mach 6 and Mach 15. The plasma parameters are measured in the stagnation region in front of the nozzle of the wind tunnel and in the free stream region at the nozzle exit. The test body has a conical shape with the cone axis in the gas flow direction and the cone vertex against the flow. It is placed at the nozzle exit and is equipped with three permanent magnets. In the configuration adopted, the Faraday current flows in a closed loop completely immersed into the plasma of the shock layer. The electric field and the pressure variation due to MHD interaction have been measured on the test body walls. Microwave adsorption measurements have been used for the determination of the electron number density and the electron collision frequency. Continuum recombination radiation and line radiation emissions have been detected. The electron temperature has been determined by means of the spectroscopic data by using different methods. The electron number density has been also determined by means of the Stark broadening of H{sub {alpha}} and the H{sub {beta}} lines. Optical imaging has been utilized to visualize the pattern of the electric current distribution in the shock layer around the test body. The experiments show a considerable effect of the electromagnetic forces produced by the MHD interaction acting on the plasma flow around the test body. A comparison of the experimental data with simulation results shows a good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-DE-207A-07: Filtered Iterative Reconstruction (FIR) Via Proximal Forward-Backward Splitting: A Synergy of Analytical and Iterative Reconstruction Method for CT

Purpose: This work is to develop a general framework, namely filtered iterative reconstruction (FIR) method, to incorporate analytical reconstruction (AR) method into iterative reconstruction (IR) method, for enhanced CT image quality. Methods: FIR is formulated as a combination of filtered data fidelity and sparsity regularization, and then solved by proximal forward-backward splitting (PFBS) algorithm. As a result, the image reconstruction decouples data fidelity and image regularization with a two-step iterative scheme, during which an AR-projection step updates the filtered data fidelity term, while a denoising solver updates the sparsity regularization term. During the AR-projection step, the image is projected to the data domain to form the data residual, and then reconstructed by certain AR to a residual image which is in turn weighted together with previous image iterate to form next image iterate. Since the eigenvalues of AR-projection operator are close to the unity, PFBS based FIR has a fast convergence. Results: The proposed FIR method is validated in the setting of circular cone-beam CT with AR being FDK and total-variation sparsity regularization, and has improved image quality from both AR and IR. For example, AIR has improved visual assessment and quantitative measurement in terms of both contrast and resolution, and reduced axial and half-fan artifacts. Conclusion: FIR is proposed to incorporate AR into IR, with an efficient image reconstruction algorithm based on PFBS. The CBCT results suggest that FIR synergizes AR and IR with improved image quality and reduced axial and half-fan artifacts. The authors was partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000), and the Shanghai Pujiang Talent Program (#14PJ1404500).

60 APPLIED LIFE SCIENCES↗

Piloted simulator investigation of helicopter control systems effects on handling qualities during instrument flight

An exploratory piloted simulation was conducted to investigate the effects of the characteristics of helicopter flight control systems on instrument flight handling qualities. This joint FAA/NASA study was motivated by the need to improve instrument flight capability. A near-term objective is to assist in updating the airworthiness criteria for helicopter instrument flight. The experiment consisted of variations of single-rotor helicopter types and levels of stability and control augmentation systems (SCAS). These configurations were evaluated during an omnirange approach task under visual and instrument flight conditions. The levels of SCAS design included a simple rate damping system, collective decoupling plus rate damping, and an attitude command system with collective decoupling. A limited evaluation of stick force versus airspeed stability was accomplished. Some problems were experienced with control system mechanization which had a detrimental effect on longitudinal stability. Pilot ratings, pilot commentary, and performance data related to the task are presented.

Forrest, R. D.↗

Fatigue and flexural response of advanced carbon-carbon composites at room and elevated temperatures

The flexural response of SiC-coated carbon-carbon composites (ACC-4) at room and elevated temperatures is presented. Three-point bending tests were performed on virgin and mission-cycled specimens, and the variation in flexural strength is examined. The load-deflection behavior of the material at various temperatures is investigated, and the Weibull (1939) analysis of the strength data is performed. Micrographs of various cross sections in the damaged zone were taken, and the failure mechanisms are discussed. Fatigue tests were conducted under flexural loads, and the S-N diagram with the corresponding Weibull analysis are presented. Untested as well as fractured specimens under static and dynamic loading were C-scanned to identify the damaged zone and visualize the extent of the damage. Failure analyses are presented for both static and cyclic loading on the basis of NDE, the micrographs, and the experimental data.

Mahfuz, Hassan↗

Transition Measurements on the SWiFT Model in the National Transonic Facility

Boundary layer transition locations on the Swept Wing Flow Test (SWiFT) Hybrid Wing Body model were measured in the National Transonic Facility (NTF) at the NASA Langley Research Center using several different methods. These methods include sublimating chemical flow visualization for a limited number of low Reynolds number conditions, as well as mean static pressure and dynamic pressure measurements. Results are presented for a range of conditions in the NTF, demonstrating Mach and Reynolds number effects. The transition front locations obtained from the different techniques agree well. A variation of the static pressure transition detection method is described in which continuous angle of attack polars are performed. This approach enables detection of the transition front at more challenging (high Reynolds number) conditions than is possible with sparser data from pitch-pause angle-of-attack polars. The trip dot effectiveness is also verified using all of the available diagnostics. Additionally, low Reynolds number results are compared with those acquired on the same model at the Aircraft Research Association (ARA) facility, and these results show good agreement overall, suggesting similar freestream flow quality conditions of the two facilities.

National Transonic Facility↗

Transition Measurements on the SWiFT Model in the National Transonic Facility

Boundary layer transition locations on the Swept Wing Flow Test (SWiFT) Hybrid Wing Body model were measured in the National Transonic Facility (NTF) at the NASA Langley Research Center using several different methods. These methods include sublimating chemical flow visualization for a limited number of low Reynolds number conditions, as well as mean static pressure and dynamic pressure measurements. Results are presented for a range of conditions in the NTF, demonstrating Mach and Reynolds number effects. The transition front locations obtained from the different techniques agree well. A variation of the static pressure transition detection method is described in which continuous angle of attack polars are performed. This approach enables detection of the transition front at more challenging (high Reynolds number) conditions than is possible with sparser data from pitch-pause angle-of-attack polars. The trip dot effectiveness is also verified using all of the available diagnostics. Additionally, low Reynolds number results are compared with those acquired on the same model at the Aircraft Research Association (ARA) facility, and these results show good agreement overall, suggesting similar freestream flow quality conditions of the two facilities.

National Transonic Facility↗

Automated contouring error detection based on supervised geometric attribute distribution models for radiation therapy: A general strategy

Purpose: One of the most critical steps in radiation therapy treatment is accurate tumor and critical organ-at-risk (OAR) contouring. Both manual and automated contouring processes are prone to errors and to a large degree of inter- and intraobserver variability. These are often due to the limitations of imaging techniques in visualizing human anatomy as well as to inherent anatomical variability among individuals. Physicians/physicists have to reverify all the radiation therapy contours of every patient before using them for treatment planning, which is tedious, laborious, and still not an error-free process. In this study, the authors developed a general strategy based on novel geometric attribute distribution (GAD) models to automatically detect radiation therapy OAR contouring errors and facilitate the current clinical workflow. Methods: Considering the radiation therapy structures’ geometric attributes (centroid, volume, and shape), the spatial relationship of neighboring structures, as well as anatomical similarity of individual contours among patients, the authors established GAD models to characterize the interstructural centroid and volume variations, and the intrastructural shape variations of each individual structure. The GAD models are scalable and deformable, and constrained by their respective principal attribute variations calculated from training sets with verified OAR contours. A new iterative weighted GAD model-fitting algorithm was developed for contouring error detection. Receiver operating characteristic (ROC) analysis was employed in a unique way to optimize the model parameters to satisfy clinical requirements. A total of forty-four head-and-neck patient cases, each of which includes nine critical OAR contours, were utilized to demonstrate the proposed strategy. Twenty-nine out of these forty-four patient cases were utilized to train the inter- and intrastructural GAD models. These training data and the remaining fifteen testing data sets were separately employed to test the effectiveness of the proposed contouring error detection strategy. Results: An evaluation tool was implemented to illustrate how the proposed strategy automatically detects the radiation therapy contouring errors for a given patient and provides 3D graphical visualization of error detection results as well. The contouring error detection results were achieved with an average sensitivity of 0.954/0.906 and an average specificity of 0.901/0.909 on the centroid/volume related contouring errors of all the tested samples. As for the detection results on structural shape related contouring errors, an average sensitivity of 0.816 and an average specificity of 0.94 on all the tested samples were obtained. The promising results indicated the feasibility of the proposed strategy for the detection of contouring errors with low false detection rate. Conclusions: The proposed strategy can reliably identify contouring errors based upon inter- and intrastructural constraints derived from clinically approved contours. It holds great potential for improving the radiation therapy workflow. ROC and box plot analyses allow for analytically tuning of the system parameters to satisfy clinical requirements. Future work will focus on the improvement of strategy reliability by utilizing more training sets and additional geometric attribute constraints.

60 APPLIED LIFE SCIENCES↗

Lidar Measurements of Wind, Moisture, and Boundary Layer Evolution in a Dry Line during 1HOP 2002

Variability in the convective boundary layer moisture, wind and temperature fields and their importance in the forecasting and understanding of storms have been discussed in the literature. These . variations have been reported in relation to frontal zones, stationary boundaries and during horizontal convective rolls. While all three vary substantially in the convective boundary layer, moisture poses a particular challenge. Moisture or water vapor concentration (expressed as a mass mixing ratio, g/kg), is conserved in all meteorological processes except condensation and evaporation. The water vapor mixing ratio often remains distinct across an air-mass boundary even when the temperature difference is indistinct. These properties make it an ideal choice in visualizing and understanding many of the atmosphere's dynamic features. However, it also presents a unique measurement challenge because water vapor content can vary by more than three orders of magnitude in the troposphere. Characterization of the 3D-distribution of water vapor is also difficult as water vapor observations can suffer from large sampling errors and substantial variability both in the vertical and horizontal. This study presents ground-based measurements of wind, boundary layer structure and water vapor mixing ratio measurements observed by three co-located lidars. This presentation will focus on the evolution and variability of moisture and wind in the boundary layer during a dry line event that occurred on 22 May 2002. These data sets and analyses are unique in that they combine simultaneous measurements of wind, moisture and CBL structure to study the detailed thermal variability in and around clear air updrafts during a dryline event. It will quantify the variation caused by, in and around buoyant plumes and across a dryline. The data presented here were collected in the panhandle of Oklahoma as part of the International H2O Project (MOP-2002), a field experiment that took place over the Southern Great Plains (SGP) of the United States from 13 May to 30 June 2002. The chief goal of MOP-2002 is to improve characterization of the four-dimensional (4-D) distribution of water vapor and its application to improving the understanding and prediction of convection

Demoz, Belay↗

Improving the Automatic Inversion of Digital Alouette/ISIS Ionogram Reflection Traces into Topside Electron Density Profiles

The topside sounders of the International Satellites for Ionospheric Studies (ISIS) program were designed as analog systems. The resulting ionograms were displayed on 35 mm film for analysis by visual inspection. Each of these satellites, launched between 1962 and 1971, produced data for 10 to 20 years. A number of the original telemetry tapes from this large data set have been converted directly into digital records. Software, known as the Topside Ionogram Scalar With True-Height (TOPIST) algorithm, has been produced and used for the automatic inversion of the ionogram reflection traces on more than 100,000 ISIS-2 digital topside ionograms into topside vertical electron density profiles Ne(h). Here we present some topside ionospheric solar cycle variations deduced from the TOPIST database to illustrate the scientific benefit of improving and expanding the topside ionospheric Ne(h) database. The profile improvements will be based on improvements in the TOPIST software motivated by direct comparisons between TOPIST profiles and profiles produced by manual scaling in the early days of the ISIS program. The database expansion will be based on new software designed to overcome limitations in the original digital topside ionogram database caused by difficulties encountered during the analog-to-digital conversion process in the detection of the ionogram frame sync pulse and/or the frequency markers. This improved and expanded TOPIST topside Ne(h) database will greatly enhance investigations into both short- and long-term ionospheric changes, e.g., the observed topside ionospheric responses to magnetic storms, induced by interplanetary magnetic clouds, and solar cycle variations, respectively.

Benson, Robert F.↗

TASK 2.5.5 NATURAL EXPOSURE TESTING IN CALIFORNIA

Airborne particulate matter that settles on a roof can either reflect or absorb incoming solar radiation, dependent on the chemical content and size of the particles. These light scattering and absorption processes occur within a few microns of the surface, and can affect the solar reflectance of the roof. Wilkes et al. (2000) tested 24 different roof coatings on a low-slope test stand and observed about a 25% decrease in the solar reflectance of white-coated and aluminum-coated surfaces as the time of exposure increased; however, the decrease leveled off after 2 years. SPRI Inc. and its affiliates studied the effect of climatic exposure on the surface properties of white thermoplastic single-ply membranes and determined that membranes lose from 30 to 50% of their reflectance over 3 years (Miller et al. 2002). The CMRC and its affiliates AISI, NamZAC, MBMA, MCA and NCCA exposed unpainted and painted metal roofing on both steep- and low-slope test roofs and found that after 3 years, the painted polyvinylidene fluoride (PVDF) metal roofs lost less than 5% of their original reflectance (Miller et al. 2004). The results of the three different weathering studies are very interesting in terms of their solar reflectance after 3 years of exposure. The white thermoplastic membrane and white ceramic coating with white topcoat had original reflectance measures that were about 20 percentage points higher than the painted metal; however, after 3-years of field exposure the solar reflectance of the painted metal exceeds that of the thermoplastic membrane and equals that of the coating. The long-term loss of reflectance appears driven by the ability of the particulate matter to cling to the roof and resist being washed off by wind and or rain. Miller et al. (2002) discovered that aerosol deposition introduced biomass of complex microbial consortia onto the test roofs and the combination of contaminants and biomass accelerated the loss of solar reflectance for the thermoplastic membranes and the roof coatings. Airborne contaminants and biomass were also detected on the painted metal roofs; however, the loss of solar reflectance was less than 5% for the painted metal roofs. The chemistry of the PVDF paint resin system uses similar organic film bonding to that responsible for Teflon , making it extremely chemical resistant and dirt shedding. Miller and Rudolph (2003) found the PVDF painted metals maintained solar reflectance even after 30 years of climatic exposure. Therefore the reduction of roof reflectance is closely related to the composition of the roof and to the chemical profile of the contaminants soiling the roof. Contaminants collected from samples of roof products exposed at seven California weathering sites were analyzed for elements and carbons to characterize the chemical profile of the particles soiling each roof sample and to identify those elements that degrade or enhance solar reflectance. The losses in solar reflectance varied from site to site and also varied at a give site based on the color of the coupon. The least drop in reflectance was observed in the alpine climate of McArthur while the largest drop occurred in sites near urban development. Light color samples were soiled after just one year of exposure. The darker color coupons did not show the same seasonal variations in solar reflectance as observed for the lighter colors. However, after an additional year of exposure the samples at all sites regained most of their solar reflectance due to rain and/or wind washing. The loss of reflectance appears cyclical with the onset of seasons having more rainfall. Solar reflectance of the cool pigmented coupons always exceeded that of the conventional pigmented coupons. Climatic soiling did not cause the cool pigmented roof coupons to lose any more solar reflectance than their conventional pigmented counterparts. The effect of roof slope appears to have more of an effect on lighter color roofs whose solar reflectance exceeds at least 0.5 and visually shows the accumulation of airborne contaminants. The thermal emittance remained invariant with time and location and was therefore not affected by climatic soiling. A thin-film deposition model was developed based on first principles, which simulates light interaction with a soiled substrate. This model was used in combination with the measured data to determine the solar absorptance and reflectance of particulate matter at each of the sites calculated using least squares fitting routines. Principal Component Analysis was used to determine the most important combinations of chemicals correlated with changes in solar absorption. Linear regression helped extract an approximate correlation using chromium, iron and elemental carbon concentrations. It appears that chromium ranks first, iron ranks second, and elemental carbon ranks third in importance to soil absorptance in the data

09 BIOMASS FUELS↗

An investigation of wing leading-edge vortices at supersonic speeds

Studies at subsonic and transonic speeds of the fundamental vortex behavior on the leeward surface of wings have led to the design of several unique and novel leading-edge devices commonly referred to as 'vortex flaps'. The present investigation has the objective to provide some fundamental vortex-flow results obtained at supersonic speeds. Experimental studies were performed in which pressure data and several types of flow visualization data were obtained on the leeward surface of a series of flat delta-wing models to identify the various flow mechanisms which can occur and to determine the effect of leading-edge sweep, Mach number, and angle of attack on the vortex strength and location. The reported investigation forms part of a study which is to explore the use of wing leading-edge vortex technology as a supersonic wing-design tool. The obtained results indicate that the procedure of distributing the vortex force as a pressure variation about a vortex action line is a promising concept.

Miller, D. S.↗

Investigation of Radiometric Properties of LANDSAT-4 MSS

Two full frames of radiometrically corrected (Type A) LANDSAT-4 MSS data were analyzed digitally and visually for evidence of residual calibration differences between detectors, quantization effects, and other sensor-related artifacts. Both standard statistical and Fourier analysis techniques were employed. Opportunities for coincident coverage by LANDSAT 3 and 4 were identified in the contiguous 48 states. Paired acquisitions for two scenes were obtained and analyzed to establish relatonships between signal values from common areas imaged by the MSS systems. Another pair with coverage by LANDSAT 2 and 4 was obtained and analyzed. Detector-to-detector differences, coherent noise, line length variation, and LANDSAT 4 to LANDSAT 3 calibration are discussed.

Rice, D. R.↗