Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “version control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Salvage HDR Brachytherapy for Recurrent Prostate Cancer After Previous Definitive Radiation Therapy: 5-Year Outcomes

Purpose: Evaluate efficacy and toxicity of salvage high-dose-rate brachytherapy (HDRB) for locally recurrent prostate cancer after definitive radiation therapy (RT). Methods and Materials: We retrospectively analyzed 52 consecutively accrued patients undergoing salvage HDRB between 1998 and 2009 for locally recurrent prostate cancer after previous definitive RT. After pathologic confirmation of locally recurrent disease, patients received 36 Gy in 6 fractions. Twenty-four patients received neoadjuvant hormonal therapy before salvage, and no patients received adjuvant hormonal therapy. Determination of biochemical failure after salvage HDRB was based on the Phoenix definition. Overall survival (OS) and bF distributions were calculated using the Kaplan-Meier method. Univariate analyses were performed to identify predictors of biochemical control. Acute and late genitourinary (GU) and gastrointestinal (GI) toxicities, based on Common Terminology Criteria for Adverse Events (version 4), were documented. Results: Median follow-up after salvage HDRB was 59.6 months. The 5-year OS estimate was 92% (95% confidence interval [CI]: 80%-97%) with median survival not yet reached. Five-year biochemical control after salvage was 51% (95% CI: 34%-66%). Median PSA nadir postsalvage was 0.1 (range: 0-7.2) reached at a median of 10.2 months after completing HDRB. As for complications, acute and late grade 3 GU toxicities were observed in only 2% and 2%, respectively. No grade 2 or higher acute GI events and 4% grade 2 GI late events were observed. On univariate analysis, disease-free interval after initial definitive RT (P=.07), percent of positive cores at the time of diagnosis (P=.08), interval from first recurrence to salvage HDRB (P=.09), and pre-HDRB prostate-specific antigen (P=.07) were each of borderline significance in predicting biochemical control after salvage HDRB. Conclusions: Prostate HDRB is an effective salvage modality with relatively few long-term toxicities. We provide potential predictors of biochemical control for prostate salvage HDRB.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An open-source data storage and visualization platform for collaborative qubit control

Developing collaborative research platforms for quantum bit control is crucial for driving innovation in the field, as they enable the exchange of ideas, data, and implementation to achieve more impactful outcomes. Furthermore, considering the high costs associated with quantum experimental setups, collaborative environments are vital for maximizing resource utilization efficiently. However, the lack of dedicated data management platforms presents a significant obstacle to progress, highlighting the necessity for essential assistive tools tailored for this purpose. Current qubit control systems are unable to handle complicated management of extensive calibration data and do not support effectively visualizing intricate quantum experiment outcomes. In this paper, we introduce Qubit Control Storage and Visualization ( QubiCSV ), a platform specifically designed to meet the demands of quantum computing research, focusing on the storage and analysis of calibration and characterization data in qubit control systems. As an open-source tool, QubiCSV facilitates efficient data management of quantum computing, providing data versioning capabilities for data storage and allowing researchers and programmers to interact with qubits in real time. The insightful visualization are developed to interpret complex quantum experiments and optimize qubit performance. QubiCSV not only streamlines the handling of qubit control system data but also improves the user experience with intuitive visualization features, making it a valuable asset for researchers in the quantum computing domain.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the first version of the new RFPI system dedicated to PIP-II project accelerator

The Low-Level Radio Frequency (LLRF) control system is one of the most critical superconducting linac infrastructures responsible for the parameters of the beam acceleration. The LLRF system mainly focuses on the electromagnetic field parameters inside the cavity. While it incorporates fast feedback algorithms to optimize energy transfer to the passing particle beam it does not follow other cryomodule or cavity parameter changes. The Radio Frequency Protection Interlock (RFPI) system closely monitors various factors (like cryomodule vacuum, beamline vacuum, field emission probe current level, temperature, RF signal leakage, etc). Its simple but reliable logic has to provide an instant decision about the LLRF system or high-power amplifier output signal blocking in case of safety region excitation. This contribution presents a new version of the RFPI system which logic is implemented in the FPGA chip. The initial work on the prototype of the new system design resulted in the PoC (Proof of Concept) device. The PoC offers the possibility of various protection logic configurations, input signals parameters evaluation, and modularity aspects verification. The structure and test results from the device evaluation are summarized and discussed in this contribution.

43 PARTICLE ACCELERATORS↗

Prioritizing ICS Beachhead Systems for Cyber Vulnerability Testing

Cyber Testing for Resilient Industrial Control Systems™ (CyTRICS™) is the Department of Energy’s (DOE’s) program for cybersecurity vulnerability testing, digital subcomponent enumeration, and forensic assessment. CyTRICS leverages best-in-class test facilities and analytic capabilities at six DOE National Laboratories and strategic partnerships with key stakeholders including technology developers, manufacturers, asset owners and operators, and interagency partners. During the program’s development, CyTRICS established a unique methodology for prioritizing digital components within operational technology (OT) and industrial control systems (ICS) in the Energy Sector Industrial Base (ESIB) for cyber vulnerability testing. The CyTRICS Prioritization Process leverages multiple characteristics of systems, components, and their contextual deployment to calculate a quantification of individual digital components for CyTRICS testing. The initial version of the CyTRICS Prioritization Process was premised largely upon the impact which could result to an industrial control system if the digital component under testing was compromised, either through malicious means, faulty engineering, or other modes. The worldwide compromise of the SolarWinds Orion platform, first reported in December 2020, through malicious interference with the digital patching cycle was a watershed event in cyber supply chain security. The SolarWinds compromised demonstrated the strategic importance of certain types of ubiquitous software, and the ability to generate widespread cybersecurity effects. To address this challenge and as a part of the Department of Energy’s response to the SolarWinds compromise, DOE’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER) directed the National Laboratories to evolve the CyTRICS Prioritization Process methodology to encompass additional factors related to the strategic importance of digital components. CESER directed CyTRICS researchers to identify, characterize, and append strategic factors to the CyTRICS Prioritization Process to provide additional weight to these characteristics. National Laboratory expert researchers identified functionality, distribution, and platform characteristics for digital components in ICS and OT that they assessed would be likely targeted in strategic initial-access cyber attack. CyTRICS has termed these factors “ICS Beachhead Systems,” leveraging a definition first advanced by Schneider Electric, which is intended as a blanket term to encompass digital components, products, and systems in OT. This paper describes the ICS Beachhead Systems identified and the rationale for inclusion. As a next step in the research and refinement process, the National Laboratories will validate this initial set of characteristics against digital components evaluated by the CyTRICS program and current implementation of the CyTRICS Prioritization Process. After validation, CyTRICS researchers will then develop a scoring methodology to generate a quantitative score to assess the degree to which a digital component is characterized as an ICS Beachhead System. Finally, the National Laboratories will append this scoring to the existing CyTRICS Prioritization Process algorithm.

97 MATHEMATICS AND COMPUTING↗

Closed-loop simulation with Grad-Shafranov equilibrium evolution for plasma control system development

Plasma control design increasingly depends on fast simulations able to connect to operational plasma control system (PCS) software for iterative development. GSevolve is a nonlinear free-boundary simulation that evolves the Grad-Shafranov equilibrium including current and pressure profiles, and can connect to all versions of the DIII-D PCS operational on devices around the world. Its ability to simulate the evolution of current continuously from open to closed field lines enables GSevolve to simulate full-discharge control from breakdown through plasma termination. GSevolve is compliant with the Plasma Control System Simulation Platform (PCSSP), a Matlab/Simulink®-based environment that serves as the primary framework for development of the ITER Plasma Control System (PCS). The code employs a novel response function-updating scheme to achieve fast simulations. The plasma evolves linearly until a significant shape change triggers a nonlinear update of the response while enforcing a prescribed accuracy. Old responses are recalled if the plasma changes back to an old shape. The equilibrium is a function of a state vector containing axisymmetric conductor currents and parameters related to parallel and perpendicular currents, which evolves according to an efficient state space circuit formulation. Control design and validation results are presented for simulations of DIII-D and EAST, connected to their corresponding versions of the DIII-D PCS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoitaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy: Preprint

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoltaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-201-06: Examining the Influence of Humidity On Reference Ion Chamber Performance

Purpose: International dosimetry protocols require measurements made with a vented ionization chamber to be corrected for the influence of air density by using the standard temperature-pressure correction factor. The effect of humidity, on the other hand, is generally ignored with the provision that the relative humidity is between certain limits (15% to 80%). However, there is little experimental data in the published literature as to the true effect of humidity on modern reference-class ion chambers. This investigation used two different radiation beams – a Co-60 irradiator and a Sr-90 check source – to examine the effect of humidity on several versions of the standard Farmer-type ion chamber. Methods: An environmental cabinet controlled the humidity. For the Co-60 beam, the irradiation was external, whereas for the Sr-90 measurements, the source itself was placed within the cabinet. Extensive measurements were carried out to ensure that the experimental setup provided reproducible readings. Four chamber types were investigated: IBA FC65-G (×2), IBA FC65-P, PTW30013 & Exradin A19. The different wall materials provided potentially different mechanical responses (i.e., in terms of expansion/contraction) to the water content in the air. The relative humidity was varied between 8 % and 97 % and measurements were made with increasing and decreasing humidity to investigate possible hysteresis effects. Results: Measurements in Co-60 were consistent with the published data obtained with primary standard cavity chambers in ICRU Report 31. Ionization currents with Sr-90 showed no dependence with the relative humidity, within the measurement uncertainties. Very good repeatability of the ionization current was obtained over successive wet/dry cycles, no hysteresis was observed, and there was no dependence on chamber type. Conclusion: This null result is very encouraging as it indicates that humidity has no significant effect on these particular types of ionization chambers, consistent with recommendations in current megavoltage dosimetry protocols.

60 APPLIED LIFE SCIENCES↗

Mbin v1.0

The Mbin software, is a software toolkit that implements the IMG metagenome binning pipeline. The software allows the user to process input metagenome contigs, and produces metagenome assembled genomes (metagenome bins) and valuation metrics per bin including completion and contamination estimates, quality assignment, predicted lineage and eukaryotic potential. It is currently packed as a portable docker container and provides the advantage of running the process of binning and analysis of the bins generated, using a suite of tools run sequentially with controls in place to capture errors and optional arguments to run a modified version depending on individual needs and capabilities.

Varghese, Neha↗

Towards Unifying the Planetary Boundary Layer and Shallow Convection in CAM5 with the Eddy-Diffusivity/Mass-Flux Approach

The modular structure of the boundary layer and convection parameterizations in atmospheric models have long been affecting the numerical representation of subgrid-scale motions and their mutual interactions. A promising alternative, the eddy-diffusivity/mass-flux approach (EDMF), has the potential for unifying the existing formulations into a consistent scheme and improving some of the long-standing issues. This study documents a step towards developing such a unified approach by implementing a stochastic multi-plume EDMF scheme into the Community Atmosphere Model (Version 5.0). Its performance in single-column mode is evaluated against the control parameterization and large-eddy simulation (LES) for two benchmark cases: marine and continental shallow convection. Overall, the results for the two parameterizations agree well with each other and with LES in terms of mean profiles of moist conserved variables and their vertical fluxes, as well as the updraft properties. However, systematic differences between the two schemes, especially for transient continental convection, are also documented. Using EDMF helps improve some of the parameterized features of shallow convection. In particular, for the highest tested vertical resolution, the EDMF cloud base and top heights and the vertical fluxes of energy and water are remarkably close to LES.

54 ENVIRONMENTAL SCIENCES↗

Neutrino Flavor Model Building and the Origins of Flavor and CP Violation

The neutrino sector offers one of the most sensitive probes of new physics beyond the Standard Model of Particle Physics (SM). The mechanism of neutrino mass generation is still unknown. The observed suppression of neutrino masses hints at a large scale, conceivably of the order of the scale of a rand unified theory (GUT), which is a unique feature of neutrinos that is not shared by the charged fermions. The origin of neutrino masses and mixing is part of the outstanding puzzle of fermion masses and mixings, which is not explained ab initio in the SM. Flavor model building for both quark and lepton sectors is important in order to gain a better understanding of the origin of the structure of mass hierarchy and flavor mixing, which constitute the dominant fraction of the SM parameters. Recent activities in neutrino flavor model building based on non-Abelian discrete flavor symmetries and modular flavor symmetries have been shown to be a promising direction to explore. The emerging models provide a framework that has a significantly reduced number of undetermined parameters in the flavor sector. In addition, such a framework affords a novel origin of CP violation from group theory due to the intimate connection between physical CP transformation and group theoretical properties of non-Abelian discrete groups. Model building based on non-Abelian discrete flavor symmetries and their modular variants enables the particle physics community to interpret the current and anticipated upcoming data from neutrino experiments. Non-Abelian discrete flavor symmetries and their modular variants can result from compactification of a higher-dimensional theory. Pursuit of flavor model building based on such frameworks thus also provides the connection to possible UV completions: in particular, to string theory. We emphasize the importance of constructing models in which the uncertainties of theoretical predictions are smaller than, or at most compatible with, the error bars of measurements in neutrino experiments. While there exist proof-of-principle versions of bottom-up models in which the theoretical uncertainties are under control, it is remarkable that the key ingredients of such constructions were discovered first in top-down model building. We outline how a successful unification of bottom-up and top-down ideas and techniques may guide us towards a new era of precision flavor model building in which future experimental results can give us crucial insights into the UV completion of the SM.

Almumin, Yahya (ORCID:0000000196396772)↗

Simulation and Experimental Validation of Electromagnetic Signatures for Monitoring of Nuclear Material Storage Containers

Previous research at the Pacific Northwest National Laboratory (PNNL) has demonstrated that the low frequency electromagnetic (EM) response of a sealed metallic container interrogated with an encircling coil is a strong function of its contents and can be used to form a distinct signature which can confirm the presence of specific components without revealing hidden geometry or classified design information. Finite element simulations have recently been performed to further investigate this response for a variety of configurations composed of an encircling coil and a typical nuclear material storage container. Excellent agreement was obtained between simulated and measured impedance signatures of electrically conducting spheres placed inside an AT-400R nuclear container. Simulations were used to determine the effects of excitation frequency and the geometry of the encircling coil, nuclear container, and internal contents. The results show that it is possible to use electromagnetic models to evaluate the application of the EM signature technique to proposed versions of nuclear weapons containers which can accommodate restrictions imposed by international arms control and treaty verification legislation.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Hygrothermal simulation of exterior retrofits in a cold climate

This work presents results from moisture modeling as part of a project undertaken by Pacific Northwest National Laboratory and its research partners, the University of Minnesota, and the Oak Ridge National Laboratory. The research goal is to identify exterior wall retrofit systems for cold climates that are low cost, energy efficient, and do not result in moisture durability problems. A base case wall was identified representing a typical wood frame construction, circa 1950. Retrofit options were selected based on input from industry, academia, and published work and seven options were constructed and installed at the University of Minnesota’s cold weather exposure facility in Cloquet, MN. Measurements were carried out during winter months and the data was used for model validation. Hygrothermal simulations were then carried out using WUFI (Version 6.4) in accordance with standard ANSI/ASRHAE 160-2016, Criteria for Moisture-Control Design Analysis in Buildings. Simulations were run out to three years and results show that the exterior retrofits improve thermal performance and do not negatively impact moisture durability of the existing wall.

Aldykiewicz Jr, Antonio↗

The Role of the CEBAF Element Database in Commissioning the 12GeV Accelerator Upgrade

The CEBAF Element Database (CED) was first developed in 2010 as a resource to support model-driven configuration of the Jefferson Lab Continuous Electron Beam Accelerator (CEBAF). Since that time, its uniquely flexible schema design, robust programming interface, and support for multiple concurrent versions has permitted it to evolve into a more broadly useful operational and control system tool. The CED played a critical role before and during the 2013 startup and commissioning of CEBAF following its 18-month long shutdown and upgrade. Information in the CED about hardware components and their relations to one-another facilitated a thorough Hot Checkout process involving more than 18,000 system checks. New software relies on the CED to generate EDM screens for operators on-demand thereby ensuring that the information on those screens is correct and up-to-date. The CED also continues to fulfill its original mission of supporting model-driven accelerator setup. Using the new ced2elegant and eDT (elegant Download Tool), accelerator physicists have proven able to compute and apply energy-dependant set points with greater efficiency than ever before.

Larrieu, T.↗

Contrasting strategies of hydraulic control in two codominant temperate tree species

Biophysical controls on plant water status exist at the leaf, stem, and root levels. Therefore, we pose that hydraulic strategy is a combination of traits governing water use at each of these three levels. Here, we studied sap flux, stem water storage, stomatal conductance, photosynthesis, and growth of red oaks (Quercus rubra) and red maples (Acer rubrum). These species differ in stomatal hydraulic strategy and xylem architecture and may root at different depths. Stable isotope analysis of xylem water was used to identify root water uptake depth. Oaks were shown to access a deeper water source than maples. During non-limiting soil moisture conditions, transpiration was greater in maples than in oaks. However, during a soil dry down, transpiration and stem water storage decreased by more than 80% and 28% in maples but only by 31% and 1% in oaks. We suggest that the preferential use of deep water by red oaks allows the species to continue transpiration and growth during soil water limitations. In this case, deeper roots may provide a buffer against drought-induced mortality. Using 14 years of growth data, we show that maple growth correlates with mean annual soil moisture at 30 cm but oak growth does not. The observed responses of oak and maple to drought were not able to be explained by leaf and xylem physiology alone. Finally, we employed the Finite-difference Ecosystem-scale Tree Crown Hydrodynamics model version 2 plant hydrodynamics model to demonstrate the influence of root, stem, and leaf controls on tree-level transpiration. We conclude that all three levels of hydraulic traits are required to define hydraulic strategy.

54 ENVIRONMENTAL SCIENCES↗

Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed on a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗