Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

CONTROLLED END GAS AUTO IGNITION WITH EXHAUST GAS RECIRCULATION ON A STOICHIOMETRIC, SPARK IGNITED, NATURAL GAS ENGINE

The goal of this study is to address fundamental limitations to achieving diesel-like efficiencies in heavy duty on-highway natural gas (NG) engines. Engine knock and misfire are barriers to pathways leading to higher efficiency engines. This study explores enabling technologies for development of high efficiency stoichiometric, spark ignited, natural gas engines. These include design strategies for fast and stable combustion and higher dilution tolerance. Additionally, advanced control methodologies are implemented to maintain stable operation between knock and misfire limits. To implement controlled end- gas autoignition (C-EGAI) strategies a Combustion Intensity Metric (CIM) is used for ignition control with the use of a Woodward large engine control module (LECM). Tests were conducted using a single cylinder, variable compression ratio, cooperative fuel research (CFR) engine with baseline conditions of 900 RPM, engine load of 800 kPa indicated mean effective pressure (IMEP), and stoichiometric air/fuel ratio. Exhaust gas recirculation (EGR) tests were performed using a custom EGR system that simulates a high pressure EGR loop and can provide a range of EGR rates from 0 to 40%. The experimental measurements included the variance of EGR rate, compression ratio, engine speed, IMEP, and CIM. These five variables were optimized through a Modified Box- Benken design Surface Response Method (RSM), with brake efficiency as the merit function. A positive linear correlation between CIM and f-EGAI was identified. Consequently, CIM was used as the feedback control parameter for C-EGAI. As such, implementation of C-EGAI effectively allowed for the utilization of high EGR rates and CRs, controlling combustion between a narrower gap between knock and lean limits. The change from fixed to parametric ignition timing with CIM targeted select values of f-EGAI with an average coefficient of variance (COV) of peak pressure of 5.4. The RSM efficiency optimization concluded with operational conditions of 1080 RPM, 1150 kPa IMEP, 10.55:1 compression ratio, and 17.8% EGR rate with a brake efficiency of 21.3%. At this optimized point of peak performance, a f-EGAI for C-EGAI was observed at 34.1% heat release due to auto ignition, a knock onset crank angle value of 10.3° aTDC and ignition timing of - 24.7° aTDC. This work has demonstrated that combustion at a fixed f-EGAI can be maintained through advanced ignition control of CIM without experiencing heavy knocking events.

Cooperative Fuel Research Engine, Auto Ignition, E↗

Stochastic nonlinear analysis of unidirectional fiber composites using image-based microstructural uncertainty quantification

Here, we present a data-driven nonlinear uncertainty quantification and propagation framework to study the microstructure-induced stochastic performance of unidirectional (UD) carbon fiber reinforced polymer (CFRP) composites. The proposed approach integrates (1) microscopic image characterization, (2) stochastic microstructure reconstruction, and (3) efficient multiscale finite element simulations enabled by self-consistent clustering (SCA) analysis. To model the complex microstructural variability, the proposed UQ methods take the non-Gaussian uncertainty sources into account through a distribution-free sampling approach leveraging nonparametric and asymptotic statistical tools. A hierarchical conditional sampling strategy enables the simultaneous sampling of multiple sources of uncertainties. Our approach provides insights into the impact of microstructural variabilities, which are shown to have an increasing impact on the nonlinear responses of UD CFRP parts under progressive compression loading and ultimately on the failure rate over time. We discover that before CFRP parts start to fail, a characteristic time period emerges with distinctive uncertainty distributions specific to the microstructure variability and the probability of failure. Identifying the failure time period is crucial to the reliability prediction, which is an essential component of CFRP design.

36 MATERIALS SCIENCE↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sparse Control Synthesis for Uncertain Responsive Loads With Stochastic Stability Guarantees

In this report, recent studies have demonstrated the potential of flexible loads in providing frequency response services, predominantly due to their availability and cost-effectiveness. However, uncertainty and variability in various weather-related and end-use behavioral factors often impact the reliability of demand-side control performance. This work addresses this problem with the design of a demand-side control to achieve frequency response under load uncertainties. Our approach involves modeling the load uncertainties via stochastic processes that appear as both multiplicative and additive in the power system dynamics. Recently developed mean square exponential stability (MSES) results for continuous-time linear stochastic systems are applied to pose the control synthesis problem which results in an LMI-based optimization problem. Additional costs and constraints are added to the LMI-based controller synthesis to ensure MSES, improve closed-loop transient performance, maximize tolerable uncertainties, and promote sparsity in the controller. Additionally, the fundamental limitations between the tolerable uncertainties and control efforts while ensuring MSES are discussed. Further, the control synthesis problem for the case of the full-state measurement is generalized to the case of partial-state measurements. The proposed control synthesis is illustrated on an IEEE 39 bus system with rigorous studies to demonstrate the role of sparsity, closed-loop transient performance, tolerable uncertainties, and control efforts while ensuring MSES and achieving frequency response.

42 ENGINEERING↗

Additive Manufactured Compact Microwave Absorbers

A high-performance, compact microwave absorber was created using Fused Deposition Modeling (FDM) 3D printing. Both a narrowband and a broadband absorber were created. The narrowband absorber was designed at 4.9 GHz, mid-band in WR-187 waveguide. The broadband absorber tried to achieve the best attenuation across the entire 3.95 to 5.85 GHz band. Two types of carbon loaded polylactic acid (PLA) plastic and one type of unloaded PLA were 3D printed with variable percentages of air to achieve different values of effective dielectric constant and loss tangent. The absorber comprised five or six rectangular pieces of these plastic materials. The thickness and fill factor values for each piece were optimized to minimize reflection through fast analytic modeling in MATLAB®. The results were then verified by HFSS® simulation as well. The stack progressed from the lowest loss and lowest dielectric constant to the highest at the shorting end. The final narrowband load had simulated return loss of 87 dB at 4.9 GHz with an analytic solution in MATLAB. The measured return loss of the 3D printed attenuator was 73 dB at 4.929 GHz. The total length of the absorber was 2.44 inches. A commercial absorber for WR-187 with return loss of 40 dB has length of 13 inches. The experiment proves that an effective and compact microwave absorber can be created using 3D printing.

36 MATERIALS SCIENCE↗

Beneficial Integration of Energy Storage and Load Management with Photovoltaic (PV)

In recent years, a number of industry activities have aimed at addressing the integration challenges posed by the variability and uncertainty of higher penetration of renewable generation sources, like solar photovoltaic (PV) – one of the key objectives of the Sustainable and Holistic Integration of Energy Storage and Solar PV (SHINES) program launched by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). This EPRI led Beneficial Integration of Energy Storge, and Load Management with PV project aimed to design, develop, and demonstrate end-to-end distributed energy resource (DER) integration solution to build on these activities. EPRI led project team designed and implemented a local controller that uses model predictive control (MPC) algorithm to optimally manage DERs on site by planning for a receding horizon while executing the control settings for the first step of its plan. The team has also developed a system controller to interface with the local controller to demonstrate the hierarchical control and how it can leverage DER capabilities to address challenges like over voltage and thermal limit violations which typically limits the DER hosting capacity of distribution feeders. Team has demonstrated how the local controller with optimization algorithm can effectively manage controllable loads like HVAC, water heater, and pool pumps to allow for greater integration of PV with relatively smaller energy storage system requirements. Optimal utilization of the load control can also reduce the depth of discharge of batteries to meet grid export/import limit from behind-the-meter (BTM) DERs. Proper utilization of DER capabilities via local control intelligence, like the one developed and demonstrated in this project can help the industry to address integration challenges of higher penetration of solar PV in economically efficient manner. This can help to accelerate deployment of clean renewable energy systems at lower societal cost.

14 SOLAR ENERGY↗

Resource and Load Compatibility Assessment of Wind Energy Offshore of Humboldt County, California

Floating offshore wind is being considered in northern California as indicated by the Bureau of Ocean Energy Management’s issuance of a lease consideration in the Humboldt Call Area. Humboldt County offers access to this enormous resource, but local electric load and transmission are limited. The potential impacts of offshore wind generators at three different scales were studied using a regional grid model of Humboldt County. Offshore wind generation was calculated using modeled wind speed data and 12-MW turbine specifications and integrated with projected load and historical generation. Offshore wind farms deployed in the Humboldt Call Area achieve annual capacity factors between 45% and 54% after losses and maintenance. Power output is variable between and within seasons, with full power output 30% of the time and no output approximately 20% of the time. Electricity from a 48-MW wind farm provides 22% of regional load with limited exports. A 144-MW wind farm serves 38% of local load, exporting 40% of its electricity with the extant 70-MW transmission capacity. A full build-out of 1836 MW would result in 88% curtailment with existing transmission. Across scenarios, offshore wind variability necessitates reliance on existing power plants to meet local demand in periods of low wind.

17 WIND ENERGY↗

A Privacy Preserving Model-Free Optimization and Control Framework for Demand Response from Residential Thermal Loads

We consider the problem of optimizing the cost of procuring electricity for a large collection of homes managed by a load serving entity, by pre-cooling or pre-heating the thermal inertial loads in the homes to avoid procuring power during periods of peak electricity pricing. We would like to accomplish this objective in a completely privacy-preserving and model-free manner, that is, without direct access to the state variables (temperatures or power consumption) or the dynamical models (thermal characteristics) of individual homes, while guaranteeing personal comfort constraints of the consumers. We propose a two-stage optimization and control framework to address this problem. In the first stage, we use a long short-term memory (LSTM) network to predict hourly electricity prices, based on historical pricing data and weather forecasts. Given the hourly price forecast and thermal models of the homes, the problem of designing an optimal power consumption trajectory that minimizes the total electricity procurement cost for the collection of thermal loads can be formulated as a large-scale integer program (with millions of variables) due to the on-off cyclical dynamics of such loads. We provide a simple heuristic relaxation to make this large-scale optimization problem model-free and computationally tractable. In the second stage, we translate the results of this optimization problem into distributed open-loop control laws that can be implemented at individual homes without measuring or estimating their state variables, while simultaneously ensuring consumer comfort constraints. We demonstrate the performance of this approach on a large-scale test case comprising of 500 homes in the Houston area and benchmark its performance against a direct model-based optimization and control solution.

Sivaranjani, S.↗

Design and Analysis of High Heat Flux Plasma-Facing Components for NSTX Upgrade

The National Spherical Tokamak Experiment (NSTX) upgrade (NSTX-U) requirements lead to enhanced heat loads on plasma-facing components (PFCs) especially in the divertor regions, where normal heat flux density can reach up to 8 MW/m 2 . For these high heat flux (HHF) regions, the PFCs were redesigned, to use castellations which relieved the thermal stresses associated with high incident heat flux. Another design feature of HHF PFCs is the absence of front face mounting holes which create localized areas of high temperature and thermal stress concentrations. Optimized shaping of the front face of the HHF PFCs eliminates regions where the front face is perpendicular to the heat flux direction during normal helicity operation and spreads the heat load. A unique mechanism was designed to connect PFC tiles to the NSTX-U center stack casing using locking features accessible from the low heat flux regions. Isotropic graphite was selected as the HHF PFC tile material. Initial tile design parameters were accessed using analytical expressions for pulsed heat flux loading. A working prototype of the locking mechanism was created during the initial stages of the design to prove the concept performance. This article presents an overview of the divertor HHF PFC design and the results of the thermal and structural analyses performed using ANSYS software. The results of the analyses cover normal operating conditions and disruptions which impose electromagnetic (EM) loads from eddy and halo currents. The 3-D, transient, nonlinear analyses took into account the temperature-dependent properties of the materials, friction interfaces between the parts, and variable electric properties of the parts and interfaces. The results confirm that the HHF PFC tiles remain within the allowable limits for the loads defined by the NSTX-U Recovery Project. In addition, tolerance stack up analyses were performed to ensure tile performance in the worst possible assembly configuration. Finally, the design process was completed successfully, and the NSTX HHF PFC tiles are currently in the production phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Operation for Resilient and Economic Modes in an Islanded Alaskan Grid

Legacy energy management systems for distribution system or microgrids are typically driven by economics. During extreme events, resiliency can be defined as ability of the system to keep supplying critical loads. Resilient operation during extreme events (e.g. avalanche in Alaska) may require decision variables to be different and conflicting with economic operation. Operational objectives are driven by a complex consideration of the economic, reliable and resilient operation of the system: economic and reliable in normal operating state and resilient during extreme events. Challenge is to move between economic and resilient operation in optimal manner and setting up problem formulation and constraints specially with Distributed Energy Resources (DERs). In this paper, we focus on striking a balance between optimal economic and resilient operation using novel formulation and developed tool called Resiliency Enabled Energy System Operation Toolbox (RE-ESOT). Simulation results are provided for a real islanded grid in Alaska with battery energy systems.

50 EE - Wind and Water Power Program - Water (EE-4↗

Experimental study of airpath electrification in an opposed-piston two stroke (OP2S) engine architecture

The opposed-piston two stroke (OP2S) engine shows potential as an alternative engine architecture to the conventional four stroke engine due to its high-power density, thermal efficiency, and versatile airpath management system. Since the pistons of a two-stroke engine do not pump the air into and out of the cylinder like in a four-stroke engine, the selection of the air induction devices and airpath actuators becomes critical to optimize engine performance. Both the pumping losses and the in-cylinder combustion process can be affected by the scavenging process in a two-stroke engine. Therefore, this study compares two different airpath configurations for the same family of OP2S engines and investigates performance metrics like scavenging control, pumping work, net indicated and brake efficiencies, and engine-out emissions associated with each airpath. Data was collected on a 3.2 L, two-cylinder OP2S engine with an electrically assisted turbocharger (EAT) and a 4.9 L displacement, three-cylinder engine with a variable geometry turbocharger (VGT) and a supercharger. The experiments consisted of speed and load sweeps for both engines at the same operating conditions to compare scavenge control in both architectures. For the three-cylinder layout, the SE sweep range was much higher, and the intake pressure could be independently varied with air flowrate, thus providing more flexibility for scavenging control. The supercharger and the VGT usage was optimized based on its efficiency map and thus, this layout had lower pumping losses compared to the EAT. The two-cylinder engine had a higher overall SE as compared to the three-cylinder engine, but the intake pressure and air flowrate could not be decoupled, leading to over scavenging and increased short circuiting of fresh charge into the exhaust.

Bhatt, Ankur [Clemson University, Clemson, SC, USA↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

Localized Strain Analysis of Ce- and Mg-Treated Cast Iron under Uniaxial Compression

Cast iron exhibits a wide range of mechanical properties, depending on its microstructural features. The microstructure of cast iron consists of several microconstituents with different elastic-plastic behavior, making the strain non-uniform across the bulk material. To understand the individual effects of these microconstituents on the overall mechanical behavior, local strain analysis using digital image correlation analysis was carried out. Samples with two different compositions (varying cerium, magnesium and silicon) were processed at different solidification velocities in a Bridgman furnace. Sections of the directionally solidified samples were loaded under uniaxial compression to measure global and local strain behavior. Despite the variability of the microstructure, the stress–strain curves obtained by digital image correlation (DIC) were found to react in a well-controlled way to changes in solidification velocity. It was observed that high-strain failure (greater than 15%) was accompanied by local straining of the softer ferritic phase, but during low-strain failure, local straining was not prominent. Higher nodularities, due to higher solidification velocities, raised the compressive strength without affecting the toughness significantly. Higher percentages of carbides led to higher compressive strengths with corresponding losses in ductility. The continuity of the matrix was also found to play an important role in the behavior during compression.

ductile failure↗