Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ultraviolet”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Far Ultraviolet and Visible Light Scatter Measurements for CVD Silicon Carbide Mirrors for SOHO

Chemically-vapor-deposited (CVD) silicon carbide (SiC) has become a popular mirror material for spaceborne solar instrumentation for the vacuum ultraviolet wavelength range due to its appreciable broadband reflectance and favorable thermal and opto-mechanical properties. Scatter from surfaces of mirrors operating in this wavelength range can destroy otherwise good image contrast especially for extended targets such as the sun. While visible light scatter measurements are relatively easy to conduct, far ultraviolet (FUV) scatter measurements are not so easy. Visible light (633 nm) scatter measurements were performed on CVD SiC telescope mirrors (from the same vendor) for two instruments on the Solar and Heliospheric Observatory (SOHO) -- Ultraviolet Coronagraph Spectrometer (UVCS) and Solar Ultraviolet Measurement of Emitted Radiation (SUMER). Additionally, extensive FUV scatter measurements were made for SUMER telescope mirrors. We attempt to correlate the results for those visible light scatter measurements and to explore the usefulness of visible scatter measurements to predictions of FUV scatter for this important material.

Leviton, Douglas B.↗

Performance of The Far Ultraviolet Spectroscopic Explorer Mirror Assemblies

The Far Ultraviolet Spectroscopic Explorer is a NASA astrophysics satellite which produces high-resolution spectra in the far-ultraviolet (90.5-118.7 nm bandpass) using a high effective area and low background detectors. The observatory was launched on its three-year mission from Cape Canaveral Air Station on 24 June 1999. The instrument contains four coaligned, normal incidence, off-axis parabolic mirrors which illuminate separate Rowland circle spectrograph channels equipped with holographically ruled diffraction gratings and delay line microchannel plate detectors. The telescope mirrors have a 352 x 387 mm aperture and 2245 mm focal length and are attached to actuator assemblies, which provide on-orbit, tip, tilt, and focus control. Two mirrors are coated with silicon carbide (SiC) and two are coated with lithium fluoride over aluminum (Al:LiF). We describe mirror assembly in-flight optical and mechanical performance. On-orbit measurements of the far-ultraviolet point spread function associated with each mirror are compared to expectations based on pre-flight laboratory measurements and modeling using the Optical Surface Analysis Code and surface metrology data. On-orbit imaging data indicate that the mirrors meet their instrument-level requirement of 50 percent and 95 percent slit transmission for the high- and mid-resolution spectrograph entrance slits, respectively. The degradation of mirror reflectivity during satellite integration and test is also discussed. The far-ultraviolet reflectivity of the SiC- and AlLiF-coated mirrors decreased about six percent and three percent, respectively, between coating and launch. Each mirror is equipped with three actuators, which consist of a stepper motor driving a ball screw via a two-stage planetary gear train. We also discuss the mechanical performance of the mirror assemblies, including actuator performance and thermal effects.

Ohi, Raymond G.↗

Corongraphic Observations and Analyses of The Ultraviolet Solar Corona

The activities supported under NASA Grant NAG5-613 included the following: 1) reduction and scientific analysis of data from three sounding rocket flights of the Rocket Ultraviolet Coronagraph Spectrometer, 2) development of ultraviolet spectroscopic diagnostic techniques to provide a detailed empirical description of the extended solar corona, 3) extensive upgrade of the rocket instrument to become the Ultraviolet Coronal Spectrometer (UVCS) for Spartan 201,4) instrument scientific calibration and characterization, 5) observation planning and mission support for a series of five Spartan 201 missions (fully successful except for STS 87 where the Spartan spacecraft was not successfully deployed and the instruments were not activated), and 6) reduction and scientific analysis of the UVCS/Spartan 201 observational data. The Ultraviolet Coronal Spectrometer for Spartan 201 was one unit of a joint payload and the other unit was a White Light Coronagraph (WLC) provided by the High Altitude Observatory and the Goddard Space Flight Center. The two instruments were used in concert to determine plasma parameters describing structures in the extended solar corona. They provided data that could be used individually or jointly in scientific analyses. The WLC provided electron column densities in high spatial resolution and high time resolution. UVCS/Spartan provided hydrogen velocity distributions, and line of sight hydrogen velocities. The hydrogen intensities from UVCS together with the electron densities from WLC were used to determine hydrogen outflow velocities. The UVCS also provided O VI intensities which were used to develop diagnostics for velocity distributions and outflow velocities of minor ions.

Kohl, John L.↗

Far Ultraviolet Spectroscopic Explorer Observations of the Seyfert 1.5 Galaxy NGC 5548 in a Low State

We present far-ultraviolet spectra of the Seyfert 1.5 galaxy NGC 5548 obtained in 2000 June with the Far Ultraviolet Spectroscopic Explorer (FUSE). Our data span the observed wavelength range 915-1185 A at a resolution of approximately 20 km s(exp -1). The spectrum shows a weak continuum and emission from O VI (lambda)(lambda)1032, 1038, C III (lambda)977, and He II (lambda)1085. The FUSE data were obtained when the AGN (Active Galactic Nuclei) was in a low state, which has revealed strong, narrow O VI emission lines. We also resolve intrinsic, associated absorption lines of O VI and the Lyman series. Several distinct kinematic components are present, spanning a velocity range of approximately 0 to -1300 km s(exp -1) relative to systemic, with kinematic structure similar to that seen in previous observations of longer wavelength ultraviolet (UV) lines. We explore the relationships between the far-UV (ultraviolet) absorbers and those seen previously in the UV and X-rays. We find that the high-velocity UV absorption component is consistent with being low-ionization, contrary to some previous claims, and is consistent with its non-detection in high-resolution X-ray spectra. The intermediate velocity absorbers, at -300 to -400 km s(exp -1), show H I and O VI column densities consistent with having contributions from both a high-ionization X-ray absorber and a low-ionization UV absorber. No single far-UV absorbing component can be solely identified with the X-ray absorber.

Brotherton, M. S.↗

Photodiode-Based, Passive Ultraviolet Dosimeters

Simple, passive instruments have been developed for measuring the exposure of material specimens to vacuum ultraviolet (VUV) radiation from the Sun. Each instrument contains a silicon photodiode and a coulometer. The photocharge generated in the photodiode is stored in the coulometer. The accumulated electric charge measured by use of the coulometer is assumed to be proportional to the cumulative dose of VUV radiation expressed in such convenient units as equivalent Sun hours (ESH) [defined as the number of hours of exposure to sunlight at normal incidence]. Intended originally for use aboard spacecraft, these instruments could also be adapted to such terrestrial uses as monitoring the curing of ultraviolet-curable epoxies. Each instrument includes a photodiode and a coulometer assembly mounted on an interface plate (see figure). The photodiode assembly includes an aluminum housing that holds the photodiode, a poly(tetrafluoroehylene) cosine receptor, and a narrow-band optical filter. The cosine receptor ensures that the angular response of the instrument approximates the ideal angular response (proportional to the cosine of the angle of incidence). The filter is chosen to pass the ultraviolet wavelength of interest in a specific experiment. The photodiode is electrically connected to the coulometer. The factor of proportionality between the charge stored in the coulometer and ultraviolet dosage (in units of ESH) is established, prior to use, in calibration experiments that involve the use of lamps and current sources traceable to the National Institute of Standards and Technology.

Vaughn, Jason A.↗

Time-Resolved Ultraviolet Spectroscopy of The M-Dwarf GJ 876 Exoplanetary System

Extrasolar planets orbiting M-stars may represent our best chance to discover habitable worlds in the coming decade. The ultraviolet spectrum incident upon both Earth-like and Jovian planets is critically important for proper modeling of their atmospheric heating and chemistry. In order to provide more realistic inputs for atmospheric models of planets orbiting low-mass stars, we present new near- and far-ultraviolet (NUV and FUV) spectroscopy of the M-dwarf exoplanet host GJ 876 (M4V). Using the COS and STIS spectrographs on board the Hubble Space Telescope, we have measured the 1150-3140 A spectrum of GJ 876. We have reconstructed the stellar H1 Ly alpha emission line profile, and find that the integrated Ly alpha flux is roughly equal to the rest of the integrated flux (1150-1210 A + 1220-3140 A) in the entire ultraviolet bandpass (F(Ly alpha)/F(FUV+NUV) equals approximately 0.7). This ratio is approximately 2500x greater than the solar value. We describe the ultraviolet line spectrum and report surprisingly strong fluorescent emission from hot H2 (T(H2) greater than 2000 K). We show the light curve of a chromospheric + transition region flare observed in several far-UV emission lines, with flare/quiescent flux ratios greater than or equal to 10. The strong FUV radiation field of an M-star (and specifically Ly alpha) is important for determining the abundance of O2--and the formation of biomarkers-in the lower atmospheres of Earth-like planets in the habitable zones of low-mass stars.

France, Kevin↗

Time-Resolved Ultraviolet Spectroscopy of the M-Dwarf GJ 876 Exoplanetary System

Extrasolar planets orbiting M-stars may represent our best chance to discover habitable worlds in the coming decade. The ultraviolet spectrum incident upon both Earth-like and Jovian planets is critically important for proper modeling of their atmospheric heating and chemistry. In order to provide more realistic inputs for atmospheric models of planets orbiting low-mass stars, we present new near- and far-ultraviolet (NUV and FUV) spectroscopy of the M-dwarf exoplanet host GJ 876 (U4V). Using the COS and STIS spectrographs aboard the Hubble Space Telescope, we have measured the 1150 - 3140 Ang. spectrum of GJ 876. We have reconstructed the stellar H I Ly-alpha emission line profile, and find that the integrated Ly-apha flux is roughly equal to the rest of the integrated flux (1150 - 1210 Ang + 1220 - 3140 Ang) in the entire ultraviolet bandpass (F(Ly-alpha)/F(FUV+NUV) approximately equals 0.7). This ratio is approximately 2500 x greater than the solar value. We describe the ultraviolet line spectrum and report surprisingly strong fluorescent emission from hot H2 (T(H2) > 2000 K). We show the light-curve of a chromospheric + transition region flare observed in several far-UV emission lines, with flare/ quiescent flux ratios :2: 10. The strong FUV radiation field of an M-star (and specifically Ly-alpha) is important for determining the abundance of O2 - and the formation of biomarkers - in the lower atmospheres of Earth-like planets in the habitable zones of low-mass stars.

France, Kevin↗

Extreme Ultraviolet Variability Experiment (EVE) Multiple EUV Grating Spectrographs (MEGS): Radiometric Calibrations and Results

The NASA Solar Dynamics Observatory (SDO), scheduled for launch in early 2010, incorporates a suite of instruments including the Extreme Ultraviolet Variability Experiment (EVE). EVE has multiple instruments including the Multiple Extreme ultraviolet Grating Spectrographs (MEGS) A, B, and P instruments, the Solar Aspect Monitor (SAM), and the Extreme ultraviolet SpectroPhotometer (ESP). The radiometric calibration of EVE, necessary to convert the instrument counts to physical units, was performed at the National Institute of Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF III) located in Gaithersburg, Maryland. This paper presents the results and derived accuracy of this radiometric calibration for the MEGS A, B, P, and SAM instruments, while the calibration of the ESP instrument is addressed by Didkovsky et al. . In addition, solar measurements that were taken on 14 April 2008, during the NASA 36.240 sounding-rocket flight, are shown for the prototype EVE instruments.

Hock, R. A.↗

Absolute intensity calibration of the Wendelstein 7-X high efficiency extreme ultraviolet overview spectrometer system

The new high effiency extreme ultraviolet overview spectrometer (HEXOS) system for the stellarator Wendelstein 7-X is now mounted for testing and adjustment at the tokamak experiment for technology oriented research (TEXTOR). One part of the testing phase was the intensity calibration of the two double spectrometers which in total cover a spectral range from 2.5 to 160.0 nm with overlap. This work presents the current intensity calibration curves for HEXOS and describes the method of calibration. The calibration was implemented with calibrated lines of a hollow cathode light source and the branching ratio technique. The hollow cathode light source provides calibrated lines from 16 up to 147 nm. We could extend the calibrated region in the spectrometers down to 2.8 nm by using the branching line pairs emitted by an uncalibrated pinch extreme ultraviolet light source as well as emission lines from boron and carbon in TEXTOR plasmas. In total HEXOS is calibrated from 2.8 up to 147 nm, which covers most of the observable wavelength region. The approximate density of carbon in the range of the minor radius from 18 to 35 cm in a TEXTOR plasma determined by simulating calibrated vacuum ultraviolet emission lines with a transport code was 5.5x10{sup 17} m{sup -3} which corresponds to a local carbon concentration of 2%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GALEX OBSERVATIONS OF DIFFUSE ULTRAVIOLET EMISSION FROM DRACO

We have studied small-scale (2') spatial variation of the diffuse ultraviolet (UV) radiation using a set of 11 Galaxy Evolution Explorer deep observations in the constellation of Draco. We find a good correlation between the observed UV background and the infrared (IR) 100 {mu}m flux, indicating that the dominant contributor of the diffuse background in the field is scattered starlight from the interstellar dust grains. We also find strong evidence of additional emission in the far-ultraviolet (FUV) band which is absent in the near-ultraviolet (NUV) band. This is most likely due to Lyman band emission from molecular hydrogen in a ridge of dust running through the field and to line emissions from species such as C IV (1550 A) and Si II (1533 A) in the rest of the field. A strong correlation exists between the FUV/NUV ratio and the FUV intensity in the excess emission regions in the FUV band irrespective of the optical depth of the region. The optical depth increases more rapidly in the UV than the IR and we find that the UV/IR ratio drops off exponentially with increasing IR due to saturation effects in the UV. Using the positional details of Spitzer extragalactic objects, we find that the contribution of extragalactic light in the diffuse NUV background is 49 {+-} 13 photons cm{sup -2} sr{sup -1} s{sup -1} A{sup -1} and is 30 {+-} 10 photons cm{sup -2} sr{sup -1} s{sup -1} A{sup -1} in the FUV band.

79 ASTRONOMY AND ASTROPHYSICS↗

ULTRAVIOLET EMISSION-LINE CORRELATIONS IN HST/COS SPECTRA OF ACTIVE GALACTIC NUCLEI: SINGLE-EPOCH BLACK HOLE MASSES

Effective methods of measuring supermassive black hole masses in active galactic nuclei (AGNs) are of critical importance to studies of galaxy evolution. While there has been much success in obtaining masses through reverberation mapping, the extensive observing time required by this method has limited the practicality of applying it to large samples at a variety of redshifts. This limitation highlights the need to estimate these masses using single-epoch spectroscopy of ultraviolet (UV) emission lines. We use UV spectra of 44 AGNs from HST/COS, the International Ultraviolet Explorer, and the Far Ultraviolet Spectroscopic Explorer of the C IV {lambda}1549, O VI {lambda}1035, O III] {lambda}1664, He II {lambda}1640, C II {lambda}1335, and Mg II {lambda}2800 emission lines and explore their potential as tracers of the broad-line region and supermassive black hole mass. The higher signal-to-noise ratio and better spectral resolution of the Cosmic Origins Spectrograph (COS) on the Hubble Space Telescope (HST) resolve AGN intrinsic absorption and produce more accurate line widths. From these, we test the viability of mass-scaling relationships based on line widths and luminosities and carry out a principal component analysis based on line luminosities, widths, skewness, and kurtosis. At L{sub 1450} {<=} 10{sup 45} erg s{sup -1}, the UV line luminosities correlate well with H{beta}, as does the 1450 A continuum luminosity. We find that C IV, O VI, and Mg II can be used as reasonably accurate estimators of AGN black hole masses, while He II and C II are uncorrelated.

79 ASTRONOMY AND ASTROPHYSICS↗

The intrinsic extreme ultraviolet fluxes of F5 V to M5 V stars

Extreme ultraviolet (EUV) radiations (10-117 nm) from host stars play important roles in the ionization, heating, and mass loss from exoplanet atmospheres. Together with the host star's Lyα and far-UV (117-170 nm) radiation, EUV radiation photodissociates important molecules, thereby changing the chemistry in exoplanet atmospheres. Since stellar EUV fluxes cannot now be measured and interstellar neutral hydrogen completely obscures stellar radiation between 40 and 91.2 nm, even for the nearest stars, we must estimate the unobservable EUV flux by indirect methods. New non-LTE semiempirical models of the solar chromosphere and corona and solar irradiance measurements show that the ratio of EUV flux in a variety of wavelength bands to the Lyα flux varies slowly with the Lyα flux and thus with the magnetic heating rate. This suggests and we confirm that solar EUV/Lyα flux ratios based on the models and observations are similar to the available 10-40 nm flux ratios observed with the Extreme Ultraviolet Explorer (EUVE) satellite and the 91.2-117 nm flux observed with the Far Ultraviolet Spectroscopic Explorer (FUSE) satellite for F5 V-M5 V stars. We provide formulae for predicting EUV flux ratios based on the EUVE and FUSE stellar data and on the solar models, which are essential input for modeling the atmospheres of exoplanets.

79 ASTRONOMY AND ASTROPHYSICS↗

Coherent control of frequency conversion toward short (picosecond) vacuum-ultraviolet radiation pulses

We present experimental data on the coherent control of frequency conversion toward the vacuum-ultraviolet regime in xenon atoms, applying intense ultrashort picoseconds (ps) radiation pulses. We report on quantum interference between two resonantly enhanced frequency conversion processes (i.e., fifth harmonic generation and four-wave mixing). The conversion processes are driven by a fundamental (ps) laser pulse at 530 nm and the phase-locked second harmonic at 265 nm. Both fifth harmonic generation and four-wave mixing yield vacuum-ultraviolet radiation at 106 nm. The two frequency conversion pathways interfere with each other - either constructively or destructively, depending on the relative phase of the driving laser pulses. Thus, by variation of the relative phase, we substantially enhance or reduce the conversion efficiency (i.e., the yield of generated vacuum-ultraviolet radiation).

74 ATOMIC AND MOLECULAR PHYSICS↗

Calibration of the Voyager ultraviolet spectrometers and the composition of the heliosphere neutrals: reassessment

The data harvest from the Voyagers’ (V 1 and V 2) Ultraviolet Spectrometers (UVS) covers encounters with the outer planets, measurements of the heliosphere sky-background, and stellar spectrophotometry. Because their period of operation overlaps with many ultraviolet missions, the calibration of V1 and V2 UVS with other spectrometers is invaluable. Here we revisit the UVS calibration to assess the intriguing sensitivity enhancements of 243% (V1) and 156% (V2) proposed recently. Using the Lyα airglow from Saturn, observed in situ by both Voyagers, and remotely by International Ultraviolet Explorer (IUE), we match the Voyager values to IUE, taking into account the shape of the Saturn Lyα line observed with the Goddard High Resolution Spectrograph on board the Hubble Space Telescope. For all known ranges of the interplanetary hydrogen density, we show that the V1 and V2 UVS sensitivities cannot be enhanced by the amounts thus far proposed. The same diagnostic holds for distinct channels covering the diffuse He i 58.4 nm emission. Our prescription is to keep the original calibration of the Voyager UVS with a maximum uncertainty of 30%, making both instruments some of the most stable EUV/FUV spectrographs in the history of space exploration. In that frame, we reassess the excess Lyα emission detected by Voyager UVS deep in the heliosphere, to show its consistency with a heliospheric but not galactic origin. Our finding confirms results obtained nearly two decades ago—namely, the UVS discovery of the distortion of the heliosphere and the corresponding obliquity of the local interstellar magnetic field (∼40{sup ∘} from upwind) in the solar system neighborhood—without requiring any revision of the Voyager UVS calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

HAZMAT. II. Ultraviolet Variability of Low-mass Stars in the GALEX Archive

The ultraviolet (UV) light from a host star influences a planet’s atmospheric photochemistry and will affect interpretations of exoplanetary spectra from future missions like the James Webb Space Telescope . These effects will be particularly critical in the study of planetary atmospheres around M dwarfs, including Earth-sized planets in the habitable zone. Given the higher activity levels of M dwarfs compared to Sun-like stars, time-resolved UV data are needed for more accurate input conditions for exoplanet atmospheric modeling. The Galaxy Evolution Explorer ( GALEX ) provides multi-epoch photometric observations in two UV bands: near-ultraviolet (NUV; 1771–2831 Å) and far-ultraviolet (FUV; 1344–1786 Å). Within 30 pc of Earth, there are 357 and 303 M dwarfs in the NUV and FUV bands, respectively, with multiple GALEX observations. Simultaneous NUV and FUV detections exist for 145 stars in both GALEX bands. Our analyses of these data show that low-mass stars are typically more variable in the FUV than the NUV. Median variability increases with later spectral types in the NUV with no clear trend in the FUV. We find evidence that flares increase the FUV flux density far more than the NUV flux density, leading to variable FUV to NUV flux density ratios in the GALEX bandpasses.The ratio of FUV to NUV flux is important for interpreting the presence of atmospheric molecules in planetary atmospheres such as oxygen and methane as a high FUV to NUV ratio may cause false-positive biosignature detections. This ratio of flux density in the GALEX bands spans three orders of magnitude in our sample, from 0.008 to 4.6, and is 1 to 2 orders of magnitude higher than for G dwarfs like the Sun. These results characterize the UV behavior for the largest set of low-mass stars to date.

79 ASTRONOMY AND ASTROPHYSICS↗

In-orbit Calibrations of the Ultraviolet Imaging Telescope

The Ultra-Violet Imaging Telescope (UVIT) is one of the payloads in ASTROSAT, the first Indian Space Observatory. The UVIT instrument has two 375 mm telescopes: one for the far-ultraviolet (FUV) channel (1300–1800 Å), and the other for the near-ultraviolet (NUV) channel (2000–3000 Å) and the visible (VIS) channel (3200–5500 Å). UVIT is primarily designed for simultaneous imaging in the two ultraviolet channels with spatial resolution better than 1.″8, along with provisions for slit-less spectroscopy in the NUV and FUV channels. The results of in-orbit calibrations of UVIT are presented in this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of Mission Enabling Broadband Lyman Ultraviolet Series to Infrared Aluminum Lithium Fluoride Reflectors

The Habitable Worlds Observatory (HWO) concept NASA flagship mission aims extend the ultraviolet (UV) observation range and sensitivity capabilities of the Hubble Space Telescope (HST) with respective goals of reaching photons down to 100 nm and containing an ultraviolet multi-object spectrograph with sensitivity improved 30-100 times. Adding the sensitivity capabilities near the Lyman series spectral range of ~100-121.6 nm reduces the reliance of redshift for key diagnostic ion lines such as O VI (103.2 nm), and heavily ionized gases of Ne VIII (77.5 nm) and MgX (62.5 nm). Clean and unoxidized aluminum (Al) reflectors provide optimal efficiency over a broadband down to the extreme ultraviolet (EUV) wavelength of ~83 nm. To prevent oxidation and maintain high spectral efficiency down to ~100 nm, the Al reflector is conventionally overcoated with a thin lithium fluoride (LiF) layer. We investigate the optimization of the deposition of the Al+LiF coating material composition to attain high spectral efficiency broadband reflectors down to 100 nm and enable the scientific goals of HWO. Lithium hexafluoroaluminate (Li3AlF6) is investigated as a different composition form of LiF to overcoat Al. The spectral efficiency and durability of the reflectors is evaluated. We will demonstrate the use of Li3AlF6 as an overcoat to protect aluminum yields ultra-high efficiency at the Hydrogen Lyman-alpha (HLyα, 121.6 nm) line with experimental reflectance values peaking up to 99%.

optical coatings↗

Synthesis of black TiO2 with efficient visible-light photocatalytic activity by ultraviolet light irradiation and low temperature annealing

Highlights: • In this work, we have prepared black titanium dioxide (B-TiO{sub 2}) nanoparticals in combination with ultraviolet light and low temperature annealing. This method is simple, efficient and environmentally friendly. • The synthesis mechanism of the black B-TiO{sub 2} nanomaterials was analyzed by combining the different characterization data with the first-principles calculation results. • The Ti-O lattice and structure of the B-TiO{sub 2} sample did not change after low-temperature annealing. • The process of H-doping results in a reduction of the localized Ti{sup 3+} states, that are also the recombination centers of excited electrons and holes. • These nanoparticles can absorb a amount of visible light and degrade the organic pollution. - Abstract: Herein, a simple, efficient, and environmentally friendly strategy to prepare black TiO{sub 2} nanoparticles has been reported; the procedure combines the ultraviolet light irradiation and low-temperature annealing (300 °C) with continuous N{sub 2} flow under atmospheric pressure. The samples were characterized by the various techniques, such as X-ray diffraction, high resolution transmission electron microcopy, Raman spectroscopy, X-ray photoelectron spectroscopy. The photocatalytic degradation of the organic contaminant Rhodamine B was investigated when black TiO{sub 2} nanoparticles was irradiaed with ultraviolet light and visible light. The black TiO{sub 2} material possesses an anatase phase and is able to absorb a high amount of photon energy in the visible light region, effectively driving photochemical degradation reactions. The enhancement of the photocatalytic activity can be attributed to the following: first, the hydrogen ions decrease the localized Ti{sup 3+} states (which are also the e{sup −}-h{sup +} recombination centers) leading to a more efficient separation of the electron-hole pairs; secondly, the conduction band electrons in black TiO{sub 2} nanoparticles are responsible for strong absorption of visible light. Consequently, the photocatalytic degradation of Rhodamine B can be significantly enhanced using black TiO{sub 2} nanoparticles. This work proves that hydrogenated black TiO{sub 2} promotes the absorption of the entire electromagnetic spectrum and exhibits high photocatalytic activity under solar light irradiation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗