Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transparency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Analysis of localized fringes in the holographic optical Schlieren system

The relation between localization of interference fringes in classical and holographic interferometry is reviewed and an application of holographic interferometry is considered for which the object is a transparent medium with nonhomogeneous refractive index. The technique is based on the analysis of the optical path length change of the object wave as it propagates through a transparent medium. Phase shifts due to variations of the speed of light within the medium give rise to an interference pattern. The resulting interferogram can be used to determine the physical properties of the medium or transparent object. Such properties include the mass density of fluids, electron densities of plasmas, the temperature of fluids, the chemical species concentration of fluids, and the state of stress in solids. The optical wave used can be either a simple plane or spherical wave, or it may be a complicated spatial wave scattered by a diffusing screen. The mathematical theory on the formation and analysis of localized fringes, the general theoretical concepts used, and a computer code for analysis are included along with the inversion of fringe order data.

Kurtz, R. L.↗

Evaluation of colorless polyimide film for thermal control coating applications

A series of essentially colorless aromatic polyimide films was synthesized and characterized with the objective of obtaining maximum optical transparency for applications in space. Optical transparency is a requirement for high performance polymeric films used in second surface mirror coatings on thermal control systems. The intensity in color of aromatic polyimide films was lowered by reducing the electronic interaction between chromophoric centers in the polymer molecular structure and by using highly purified monomers. The resulting lightly colored to colorless polyimide films were characterized by UV-visible and infrared spectroscopy before and after exposure to 300 equivalent solar hours UV irradiation and varying doses of 1 MeV electron irradiation. After irradiation, the films were found to be 2 to 2.5 times more transparent than commercial polyimide film of the same thickness.

St.clair, A. K.↗

Evaluation of colorless polyimide film for thermal control coating applications

A series of essentially colorless aromatic polyimide films was synthesized and characterized with the objective of obtaining maximum optical transparency for applications in space. Optical transparency is a requirement for high performance polymeric films used in second surface mirror coatings on thermal control systems. The intensity in color of aromatic polyimide films was lowered by reducing the electronic interaction between chromophoric centers in the polymer molecular structure and by using highly purified monomers. The resulting lightly colored to colorless polyimide films were characterized by UV-visible and infrared spectroscopy before and after exposure to 300 equivalent solar hours UV irradiation and varying doses of 1 MeV electron irradiation. After irradiation, the films were found to be 2 to 2.5 times more transparent than commercial polyimide film of the same thickness.

St. Clair, A. K.↗

Compression-Failure Mechanisms in Composite Laminates

Failure mechanisms observed using transparent fiberglass/epoxy birefringent materials. Technique based on use of transparent fiberglass/epoxy birefringent material. Transparency allows visual observation of location of initial laminate failure and of subsequent failure propagation; birefringence allows laminate stress distribution to be observed during test and also after test if permanent residual stresses occur. Nondestructive technique developed to observe failure as it develops and as propagates within laminate.

Shuart, M. J.↗

Optically transparent/colorless polyimides

Several series of linear aromatic polyimide films have been synthesized and characterized with the objective of obtaining maximum optical transparency. Two approaches have been used as part of this structure-property relationship study. The first approach is to vary the molecular structure so as to separate chromophoric centers and reduce electronic interactions between polymer chains to lower the intensity of color in the resulting polymer films. A second and concurrent approach is to perform polymerizations with highly purified monomers. Glass transition temperatures of thermally cured polyimide films are obtained by thermomechanical analysis and thermal decomposition temperatures are determined by thermogravimetric analysis. Transmittance UV-visible spectra of the polyimide films are compared to that of a commercial polyimide film. Fully imidized films are tested for solubility in common organic solvents. The more transparent films prepared in this study are evaluated for use on second-surface mirror thermal control coating systems. Lightly colored to colorless films are characterized by UV-visible spectroscopy before and after exposure to 300 equivalent solar hours UV irradiation and varying doses of 1 MeV electron irradiation. The effects of monomer purity, casting solvent and cure atmosphere on polyimide film transparency are also investigated.

Stclair, A. K.↗

Evaluation of colorless polyimide film for thermal control coating applications

A series of essentially colorless aromatic polyimide films has been synthesized and characterized with the objective of obtaining maximum optical transparency for applications in space. Optical transparency is a requirement for high performance polymeric films used in second surface mirror coatings on thermal control systems. The intensity in color of aromatic polyimide films was lowered by reducing the electronic interaction between chromophoric centers in the polymer molecular structure and by using highly purified monomers. The resulting lightly colored to colorless polyimide films have been characterized by UV-visible and infrared spectroscopy before and after exposure to 300 equivalent solar hours UV irradiation and varying doses of 1 MeV electron irradiation. After irradiation, the films were found to be 2 to 2.5 times more transparent than commercial polyimide film of the same thickness.

St. Clair, A. K.↗

Spatial characterization of acid rain stress in Canadian Shield Lakes

The lake acidification in Northern Ontario was investigated using LANDSAT TM to sense lake volume reflectance and also to provide important vegetation and terrain characteristics. The purpose of this project was to determine the ability of LANDSAT to assess water quality characteristics associated with lake acidification. Results demonstrate that a remote sensor can discriminate lake clarity based upon reflection. The basic hypothesis is that seasonal and multi-year changes in lake optical transparency are indicative of sensitivity to acidic deposition. In many acid-sensitive lakes optical transparency is controlled by the amount of dissolved organic carbon present. Seasonal changes in the optical transparency of lakes can potentially provide an indication of the stress due to acid deposition and loading.

Tanis, F. J.↗

Simulated ion thruster operation without beam extraction

The development of high power (100's of kilowatts) ion engines may be greatly facilitated through the use of a technique which enables optimization of the discharge chamber to be performed without beam extraction. Ion thruster operation without beam extraction results in an experimentally determined decrease in the accelerator system transparency to ions from approximately 0.8 down to 0.22 for the standard J-Series thruster ion optics. This decreased ion transparency translates into a decreased propellant flow rate requirement for operation without beam extraction, enabling testing to be performed in smaller vacuum chambers with lower pumping speeds. Performance curves simulated without beam extraction are shown to agree well with actual performance curves obtained with beam extraction. Screen grid temperatures, however, are shown to be significantly higher without beam extraction due to the decrease in the accelerator system transparency to ions.

Brophy, John R.↗

Windows in the Milky Way

The objectives were twofold: (1) to study the IRAS emission levels in the vicinity of Baade's Window and in other optically transparent regions near the Galactic Center; and (2) to study the IRAS emission levels along sightlines in the Milky Way that exhibit very little CO emission. Tests were attempted to see whether the optically transparent 'windows' near the Galactic center can be identified (as FIR-weak regions) in the IRAS data base; and if so, whether the CO weak regions found elsewhere in the Milky Way represent similarly FIR weak and thus optically transparent sightlines through the Galaxy. The CO weak regions were also targeted in an effort to study the diffuse intercloud dust and its warming by the interstellar radiation field.

Waller, William H.↗

Reflection type skin friction meter

A housing block is provided having an upper surface conforming to the test surface of a model or aircraft. An oil film is supplied upstream of a transparent wedge window located in this upper surface by an oil pump system located external to the housing block. A light source located within the housing block supplies a light beam which passes through this transparent window and is reflected back through the transparent window by the upper surface of the oil film to a photo-sensitive position sensor located within the housing. This position sensor allows the slope history of the oil film caused by and aerodynamic flow to be determined. The skin friction is determined from this slope history. Internally located mirrors augment and sensitize the reflected beam as necessary before reaching the position sensor. In addition, a filter may be provided before this sensor to filter the beam.

Bandyopadhyay, Promode R.↗

Polyimides from a methylene-bridged dianhydride

High-molecular weight, high-temperature, highly optically transparent films suitable for electronic and aerospace applications were prepared based on a novel methylene-bridged dianhydride 3,3-prime bis(3,4-dicarboxyphenoxy) diphenylmethane dianhydride (PDMDA). All films had lower dielectric constants and significantly higher optical transparency than the commercial Kapton H film, with air-cured films having slightly higher dielectric constants and lower optical transparency than vacuum films, due to oxidative cross-linking.

Boston, Harold G.↗

Fluorinated Poly(Phenylene Ether Ketones)

Fluorinated poly(phenylene ether ketones) are colorless, transparent, low-dielectric-constant, highly thermally stable polymers. Particularly suitable for use as film and coating materials in electronic and thermal-control applications such as; passivant insulating coats and interlevel dielectrics in microelectronic circuits, or as protective transparent coats on solar cells or mirrors. Solubility and transparency of 12F-PEK along with its lower dielectric constant and other properties make it more useful as dielectric film and coating material in many applications.

St. Clair, Anne K.↗

CLIPS, AppleEvents, and AppleScript: Integrating CLIPS with commercial software

Many of today's intelligent systems are comprised of several modules, perhaps written in different tools and languages, that together help solve the user's problem. These systems often employ a knowledge-based component that is not accessed directly by the user, but instead operates 'in the background' offering assistance to the user as necessary. In these types of modular systems, an efficient, flexible, and eady-to-use mechanism for sharing data between programs is crucial. To help permit transparent integration of CLIPS with other Macintosh applications, the AI Research Branch at NASA Ames Research Center has extended CLIPS to allow it to communicate transparently with other applications through two popular data-sharing mechanisms provided by the Macintosh operating system: Apple Events (a 'high-level' event mechanism for program-to-program communication), and AppleScript, a recently-released scripting language for the Macintosh. This capability permits other applications (running on either the same or a remote machine) to send a command to CLIPS, which then responds as if the command were typed into the CLIPS dialog window. Any result returned by the command is then automatically returned to the program that sent it. Likewise, CLIPS can send several types of Apple Events directly to other local or remote applications. This CLIPS system has been successfully integrated with a variety of commercial applications, including data collection programs, electronics forms packages, DBMS's, and email programs. These mechanisms can permit transparent user access to the knowledge base from within a commercial application, and allow a single copy of the knowledge base to service multiple users in a networked environment.

Compton, Michael M.↗

Temperature Measurement of a Glass Material Using a Multiwavelength Pyrometer

Temperature measurement of a substance that is transparent using the traditional 1-color, 2-color and other pyrometers has been difficult. The radiation detected by pyrometers do not come from a well defined location in the transparent body. The multiwavelength pyrometer developed at the NASA Lewis Research Center can measure the surface temperature of many materials. We show in this paper that it also measures the surface and a bulk subsurface temperature of transparent materials like glass.

Ng, Daniel↗

Emittance Measurements at the Langley Chemical Physics Laboratory

Total hemispherical emittance measurements are made routinely for materials which may be heated by electrical resistance methods over the temperature range of 600 degrees to 2,000 F by using a black-body reference method. This employs a conical black body and a thermopile detector with a calcium fluoride lens. Emittance is obtained by measuring the radiant flux from the specimen strip and comparing it with the flux from an equal area of the black-body cone at the same temperature. The temperature measurements are made by use of thermocouples. It is planned to extend the temperature range of this type of measurement to temperatures above 2,000 F. Another technique has been investigated for measuring emittance of materials not amenable to electrical heating or thermocouple attachment. This method uses a black-body-cavity furnace similar to that used in reference 5 to measure emittance of transparent materials such as glass. The method employs a heated black-body cavity in which the semicircular specimen is allowed to come to the equilibrium temperature of the cavity and then is rotated in front of a water-cooled viewing port where a sensitive thermistor detector alternately views the specimen surface and the black-body cavity. The ratio of the two readings gives the specimen emittance directly, for the temperature of the black body. The detector output is recorded on a fast Brown self-balancing potentiometer. The furnace is provided with a water-cooled blackened shutter which may be inserted behind the specimen to eliminate any transmitted black-body radiation if the specimen is transparent. This apparatus is capable of measuring total normal emittance over the temperature range of 1,000 degrees to 2,000 F. Preliminary data for boron nitride specimens of two thicknesses are shown where total normal emittance is plotted against temperature for two experimental conditions: (1) black-body radiation incident on the back of the specimen and (2) no black-body radiation incident on the back of the specimen (that is, with a watercooled shutter behind the specimen). The data appear to indicate a slight transparency for the thin specimen and emittances of from 0.7 to 0.8 over the temperature range.

Lewis, B. W.↗

BOREAS Level-0 C-130 Aerial Photography

For BOReal Ecosystem-Atmosphere Study (BOREAS), C-130 and other aerial photography was collected to provide finely detailed and spatially extensive documentation of the condition of the primary study sites. The NASA C-130 Earth Resources aircraft can accommodate two mapping cameras during flight, each of which can be fitted with 6- or 12-inch focal-length lenses and black-and-white, natural-color, or color-IR film, depending upon requirements. Both cameras were often in operation simultaneously, although sometimes only the lower resolution camera was deployed. When both cameras were in operation, the higher resolution camera was often used in a more limited fashion. The acquired photography covers the period of April to September 1994. The aerial photography was delivered as rolls of large format (9 x 9 inch) color transparency prints, with imagery from multiple missions (hundreds of prints) often contained within a single roll. A total of 1533 frames were collected from the C-130 platform for BOREAS in 1994. Note that the level-0 C-130 transparencies are not contained on the BOREAS CD-ROM set. An inventory file is supplied on the CD-ROM to inform users of all the data that were collected. Some photographic prints were made from the transparencies. In addition, BORIS staff digitized a subset of the tranparencies and stored the images in JPEG format. The CD-ROM set contains a small subset of the collected aerial photography that were the digitally scanned and stored as JPEG files for most tower and auxiliary sites in the NSA and SSA. See Section 15 for information about how to acquire additional imagery.

Newcomer, Jeffrey A.↗

High Precision Grids for Neutron, Hard X-Ray, and Gamma-Ray Imaging Systems

Fourier telescopes permit observations over a very broad band of energy. They generally include synthetic spatial filtering structures, known as multilayer grids or grid pairs consisting of alternate layers of absorbing and transparent materials depending on whether neutrons or photons are being imaged. For hard x-rays and gamma rays high (absorbing) and low (transparent) atomic number elements, termed high-Z and low-Z materials may be used. Fabrication of these multilayer grid structures is not without its difficulties. Herein the alternate layers of the higher material and the lower material are inserted in a polyhedron, transparent to photons of interest, through an open face of the polyhedron. The inserted layers are then uniformly compressed to form a multilayer grid.

Jonathan W Campbell↗

Eastern European Science Needs Sweeping Changes

Sir - Two years ago your Editorial "Eastern Promise" (vol. 426, p.369, 2003) and the News Feature "Dreaming on Danube" (vol. 427, p.94-95,2004) as well as several subsequent correspondence letters (vol. 427, pp. 196 and 677, vol. 428, p.17) touched on the situation and potential growth in scientific research in the former Soviet block countries. I would like to revisit this topic. Right now the facts are sobering: while the average GNP per capita in those countries is a few times lower than the average for the rest of Europe, their average university ranking is another order of magnitude poorer (in the latest ARWU, of the first 123 European universities only 4, and that in the second half of the list only, are from the former Soviet block). That situation calls for drastic measures. Pumping extra money into the system would change little. The only real hope is in a new generation of young dynamic scientists setting the pace for academic life. That requires selection and promotion of the best of the best. Unfortunately much of the old guard, who is not up to scientific challenges of today and who attained their positions and influence under the old regime (often due to other than professional qualifications) resist any real changes. I believe that a major change for better could be achieved by implementation into law two key requirements: transparency and competitiveness. That means a transparency of every scientist achievements (particularly in terms of publications), and wide open and fair competition for academic positions. Those two conditions should be complemented by implementation of the position of academic ombudsman (to encourage/facilitate open discussions), special grant opportunities for young scientists, and transparency of the process of awarding research grants. I, as well as a number of my colleagues concerned with the future of science and higher education in Poland, discussing many important academic issues at the Independent Academic Forum (an Association with a non-commercial website, http://www.naukaedukacia. tubaza.pl/, with tens of thousands of visits last year), strongly believe that the above postulated changes in the academic environment would lead to a major improvement in the quality and standing of scientific research and higher education in Poland and other post-communist countries (which suffer similar problems). It is symptomatic that the voice of at least hundreds of the most active and usually younger scientists heard at our NFA forum is totally ignored by the old establishment and their decision making representatives who "know better". Major political and legislative decisions are called for. We are doing our best to press for such changes.

Palosz, Witold↗