Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Monte Carlo simulation of an x-ray luminescence optical tomography scanner prototype

In this work we report the calculation of the deposited energy distribution produced by an x-ray luminescence optical tomography (XLOT) system in a phantom containing different concentrations of Gd{sub 2}O{sub 2}S:Eu nanoparticles. The calculations were performed via Monte Carlo simulation considering spectra from a W target x-ray tube operating between 30 and 90 kVp, with 1.0 mm Al added filtration. CT and XLOT tomographic images were reconstructed from the same data. The results show that XLOT has better detectability than CT alone, that the dose scales linearly with kVp for a fixed concentration of Gd{sub 2}O{sub 2}S:Eu and air-kerma rate, the scattered radiation contribution to the total dose and signal is about 20% and that the dose ratio for a 3 mm diameter insert containing 10 mg/ml Gd{sub 2}O{sub 2}S embedded in a 30 mm diameter water phantom is 6:1. This ratio drops to less than 2:1 for a 1 mg/ml concentration. Finally we show that the method of conjugate images can be used to correct for artifacts due to attenuation effects in XLOT images.

60 APPLIED LIFE SCIENCES↗

Earthquake location determination using data from DOMERAPI and BMKG seismic networks: A preliminary result of DOMERAPI project

DOMERAPI project has been conducted to comprehensively study the internal structure of Merapi volcano, especially about deep structural features beneath the volcano. DOMERAPI earthquake monitoring network consists of 46 broad-band seismometers installed around the Merapi volcano. Earthquake hypocenter determination is a very important step for further studies, such as hypocenter relocation and seismic tomographic imaging. Ray paths from earthquake events occurring outside the Merapi region can be utilized to delineate the deep magma structure. Earthquakes occurring outside the DOMERAPI seismic network will produce an azimuthal gap greater than 180{sup 0}. Owing to this situation the stations from BMKG seismic network can be used jointly to minimize the azimuthal gap. We identified earthquake events manually and carefully, and then picked arrival times of P and S waves. The data from the DOMERAPI seismic network were combined with the BMKG data catalogue to determine earthquake events outside the Merapi region. For future work, we will also use the BPPTKG (Center for Research and Development of Geological Disaster Technology) data catalogue in order to study shallow structures beneath the Merapi volcano. The application of all data catalogues will provide good information as input for further advanced studies and volcano hazards mitigation.

58 GEOSCIENCES↗

Broadband reflective metasurface for focusing underwater ultrasonic waves with linearly tunable focal length

We report a metasurface for focusing reflected ultrasonic waves over a wide frequency band of 0.45–0.55 MHz. The broadband focusing effect of the reflective metasurface is studied numerically and then confirmed experimentally using near-field scanning techniques. The focusing mechanism can be attributed to the hyperboloidal reflection phase profile imposed by different depths of concentric grooves on the metasurface. In particular, the focal lengths of the reflective metasurface are extracted from simulations and experiments, and both exhibit good linear dependence on frequency over the considered frequency band. The proposed broadband reflective metasurface with tunable focal length has potential applications in the broad field of ultrasonics, such as ultrasonic tomographic imaging, high intensity focused ultrasound treatment, etc.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-frequency energy density precipitation method for time-of-flight extraction of narrowband Lamb wave detection signals

The time-of-flight of the Lamb wave provides an important basis for defect evaluation in metal plates and is the input signal for Lamb wave tomographic imaging. However, the time-of-flight can be difficult to acquire because of the Lamb wave dispersion characteristics. This work proposes a time-frequency energy density precipitation method to accurately extract the time-of-flight of narrowband Lamb wave detection signals in metal plates. In the proposed method, a discrete short-time Fourier transform is performed on the narrowband Lamb wave detection signals to obtain the corresponding discrete time-frequency energy density distribution. The energy density values at the center frequency for all discrete time points are then calculated by linear interpolation. Next, the time-domain energy density curve focused on that center frequency is precipitated by least squares fitting of the calculated energy density values. Finally, the peak times of the energy density curve obtained relative to the initial pulse signal are extracted as the time-of-flight for the narrowband Lamb wave detection signals. An experimental platform is established for time-of-flight extraction of narrowband Lamb wave detection signals, and sensitivity analysis of the proposed time-frequency energy density precipitation method is performed in terms of propagation distance, dispersion characteristics, center frequency, and plate thickness. For comparison, the widely used Hilbert–Huang transform method is also implemented for time-of-flight extraction. The results show that the time-frequency energy density precipitation method can accurately extract the time-of-flight with relative error of <1% and thus can act as a universal time-of-flight extraction method for narrowband Lamb wave detection signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An extended trajectory-mechanics approach for calculating two-phase flow paths

A technique originating in quantum dynamics is used to derive a trajectory-based, semi-analytical solution for two-phase flow. The partial differential equation governing the evolution of the aqueous phase is equivalent to a family of ordinary differential equations defined along a path through the porous medium. The trajectories may be found by solving the differential equations directly or by post-processing the output of a numerical solution to the full set of governing equations. The trajectories, which differ from conventional streamlines, are found to bend downward in response to gravitational forces. The curvature is more pronounced as the dip of the porous layer containing the flow increases. Subtle changes in the relative permeability curve can lead to significant variations in the trajectories. The ordinary differential equation for the trajectory provides an expression for the travel time along the path. The expression produces a semi-analytical approximation to the model parameter sensitivities, the partial derivatives of the travel times with respect to changes in the permeability model. The semi-analytical trajectory-based sensitivities generally agree with those computed using a numerical reservoir simulator and a perturbation approach. The sensitivities are useful in tomographic imaging algorithms designed to estimate the spatial variation in permeability within a porous medium using multiphase observations.

58 GEOSCIENCES↗

Development of Stochastic Voronoi Lattice Structures via Two-Photon Polymerization

Low-density polymer foams of varying sizes, shapes, and densities are of specific interest to the inertial confinement fusion (ICF) program and related high-energy density plasma physics research. Historically, these foams are comprised of polystyrene or other low atomic number materials and have densities in the 30 to 300 mg/cm 3 range. However, at the lower end of this density range, these traditional polymer foams become fragile and difficult to cast and machine into the geometries needed. Recently, the need by experimentalists for materials with densities below 30 mg/cm 3 has increased. To address these needs, we are developing three-dimensional (3-D) printing techniques to create high-precision, low-density, and repeatable complex lattice structures. Using two-photon polymerization 3-D printing, we recently developed the first 5 mg/cm3 low-density lattice structure having an annular hemispherical shape. These microscale to mesoscale structures were modeled and designed using the nTopology software, specifically utilizing the "Voronoi volume lattice" and "random points in body" option blocks. All printing operations were performed using the Nanoscribe Photonic Professional GT instrument. Characterization of these 3-D structures was conducted using various microscopic and X-ray tomographic imaging techniques. Furthermore, overall printed part sizes ranged from 1 to 5 mm in diameter and were composed of lattice ligaments having thicknesses in the 3- to 5-µm range. These structures have been incorporated into ICF targets recently shot on both the University of Rochester’s Laboratory of Laser Energetics Omega laser and the National Ignition Facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MAGNETIC FIELD TOPOLOGY IN LOW-MASS STARS: SPECTROPOLARIMETRIC OBSERVATIONS OF M DWARFS

The magnetic field topology plays an important role in the understanding of stellar magnetic activity. While it is widely accepted that the dynamo action present in low-mass partially convective stars (e.g., the Sun) results in predominantly toroidal magnetic flux, the field topology in fully convective stars (masses below approx0.35 M {sub sun}) is still under debate. We report here our mapping of the magnetic field topology of the M4 dwarf G 164-31 (or Gl 490B), which is expected to be fully convective, based on time series data collected from 20 hr of observations spread over three successive nights with the ESPaDOnS spectropolarimeter. Our tomographic imaging technique applied to time series of rotationally modulated circularly polarized profiles reveals an axisymmetric large-scale poloidal magnetic field on the M4 dwarf. We then apply a synthetic spectrum fitting technique for measuring the average magnetic flux on the star. The flux measured in G 164-31 is |Bf| = 3.2 +- 0.4 kG, which is significantly greater than the average value of 0.68 kG determined from the imaging technique. The difference indicates that a significant fraction of the stellar magnetic energy is stored in small-scale structures at the surface of G 164-31. Our Halpha emission light curve shows evidence for rotational modulation suggesting the presence of localized structure in the chromosphere of this M dwarf. The radius of the M4 dwarf derived from the rotational period and the projected equatorial velocity is at least 30% larger than that predicted from theoretical models. We argue that this discrepancy is likely primarily due to the young nature of G 164-31 rather than primarily due to magnetic field effects, indicating that age is an important factor which should be considered in the interpretation of this observational result. We also report here our polarimetric observations of five other M dwarfs with spectral types from M0 to M4.5, three of them showing strong Zeeman signatures.

79 ASTRONOMY AND ASTROPHYSICS↗

MAPPING THE LINEARLY POLARIZED SPECTRAL LINE EMISSION AROUND THE EVOLVED STAR IRC+10216

We present spectro-polarimetric observations of several molecular lines obtained with the Submillimeter Array toward the carbon-rich asymptotic giant branch star IRC+10216. We have detected and mapped the linear polarization of the CO 3-2, SiS 19-18, and CS 7-6 lines. The polarization arises at a distance of {approx_equal} 450 AU from the star and is blueshifted with respect to the Stokes I. The SiS 19-18 polarization pattern appears to be consistent with a locally radial magnetic field configuration. However, the CO 3-2 and CS 7-6 line polarization suggests an overall complex magnetic field morphology within the envelope. This work demonstrates the feasibility of using spectro-polarimetric observations to carry out tomographic imaging of the magnetic field in circumstellar envelopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Seismotectonic evidence for subduction beneath the Eastern Greater Caucasus

SUMMARY We generated high-resolution 3-D seismic velocity models as well as a relocated earthquake catalogue across the eastern Greater Caucasus and Kura basins. This work was done using data from the recently upgraded Republic Seismological Survey Center's (RSSC) seismic network. We generated our tomographic images of crustal velocity structure in Azerbaijan using double-difference inversions (i.e. tomoDD and hypoDD). Earthquake catalogues from the RSSC between 2011 and 2016 were used; these catalogues include absolute arrival times of 103 288 P- and 120 952 S-wave traveltime picks for 7574 events recorded at 35 stations in Azerbaijan. Beginning with a layered, 1-D velocity model that was estimated using VELEST, we inverted simultaneously for relative location, Vp and Vs on a 3-D grid with dimensions 670 × 445 × 45 km, with a uniform grid spacing of 55 × 55 × 5 km for all of Azerbaijan. We observe that the relocated hypocentres cluster into two depth ranges, at the surface and at depth, that appear to correspond to major fault zones and the top of a subducting plate. Additionally, we note intermediate depth seismicity (∼50–60 km) beneath the Kura Basin, and a northward deepening of earthquake depths. Seismic velocities vary significantly throughout the study region; we observe very slow velocities throughout the Kura Basin between 5 and 15 km, and elevated velocities at 20–35 km. The wholesale velocity structure and seismic structure of Kura Basin strongly mirrors that of the Caspian Sea, which suggests that the geodynamics of the Caspian continue westwards into Azerbaijan. The key results of this study suggest that the northward subduction observed in the Caspian Sea continues beneath the Eastern Greater Caucasus, as well as provides evidence for active faulting along the southern margin of the mountain range.

Gunnels, Michael↗

Broad-band trajectory mechanics

We present here a trajectory-based solution to the elastodynamic equation of motion that is valid across a wide range of seismic frequencies. That is, the derivation of the solution does not invoke a high-frequency assumption or require that the medium have smoothly varying properties. The approach, adopted from techniques used in quantum dynamics, produces a set of coupled ordinary differential equations for the trajectory, the slowness vector and the elastic wave amplitude along the ray path. The trajectories may be determined by a direct solution of the governing equations or derived as the by-product of a numerical wavefield simulation. Synthetic tests with interfaces and layers containing increasingly narrow transition zones indicate that the conventional high-frequency trajectories associated with the eikonal equation bend too sharply into high-velocity regions as the wavelength exceeds the transition zone width. Tests in a velocity model, based upon mapped structural surfaces from the Geysers geothermal field in California, indicate that discrepancies between high-frequency and broad-band trajectories can exceed several hundred metres at wavelengths of 1 Hz. An application to a crosswell tomographic imaging experiment demonstrates that the technique provides a basis for the seismic monitoring of fluid flow along narrow features such as fracture zones.

58 GEOSCIENCES↗

A trajectory mechanics approach for the study of wave propagation in an anisotropic elastic medium

In this work, we derive equations describing the path and traveltime of a coherent elastic wave propagating in an anisotropic medium, generalizing expressions from conventional high-frequency asymptotic ray theory. The methodology is valid across a broad range of frequencies and allows for subwavelength variations in the material properties of the medium. The primary difference from current ray methods is the retention of a term that is neglected in the derivation of the eikonal equation. The additional term contains spatial derivatives of the properties of the medium and of the amplitude field, and its presence couples the equations governing the evolution of the amplitude and phase along the trajectory. The magnitude of this term provides a measure of the validity of expressions based upon high-frequency asymptotic methods, such as the eikonal equation, when modelling wave propagation dominated by a band of frequencies. In calculations involving a layer with gradational boundaries, we find that asymptotic estimates do deviate from those of our frequency-dependent approach when the width of the layer boundaries become sufficiently narrow. For example, for a layer with boundaries that vary over tens of meters, the term neglected by a high-frequency asymptotic approximation is significant for frequencies around 10 Hz. The visible differences in the paths of the rays that traverse the layer substantiate this conclusion. For a velocity model derived from an observed well log, the majority of the trajectories calculated using the extended approach, accounting for the frequency-dependence of the rays, are noticeably different from those produced by the eikonal equation. A suite of paths from a source to a specified receiver, calculated for a range of frequencies between 10 and 100 Hz, define a region of sensitivity to velocity variations and may be used for an augmented form of tomographic imaging.

58 GEOSCIENCES↗

Cross sections for the exclusive photon electroproduction on the proton and Generalized Parton Distributions

Unpolarized and beam-polarized four-fold cross sections $\frac{d^4 \sigma}{dQ^2 dx_B dt d\phi}$ for the $ep\to e^\prime p^\prime \gamma$ reaction were measured using the CLAS detector and the 5.75-GeV polarized electron beam of the Jefferson Lab accelerator, for 110 ($Q^2,x_B,t$) bins over the widest phase space ever explored in the valence-quark region. Several models of Generalized Parton Distributions (GPDs) describe the data well at most of our kinematics. This increases our confidence that we understand the GPD $H$, expected to be the dominant contributor to these observables. Thus, through a leading-twist extraction of Compton Form Factors, these results reveal a tomographic image of the nucleon.

43 PARTICLE ACCELERATORS↗

Tomosaic : efficient acquisition and reconstruction of teravoxel tomography data using limited-size synchrotron X-ray beams

X-rays offer high penetration with the potential for tomography of centimetre-sized specimens, but synchrotron beamlines often provide illumination that is only millimetres wide. Here an approach is demonstrated termed Tomosaic for tomographic imaging of large samples that extend beyond the illumination field of view of an X-ray imaging system. This includes software modules for image stitching and calibration, while making use of existing modules available in other packages for alignment and reconstruction. The approach is compatible with conventional beamline hardware, while providing a dose-efficient method of data acquisition. By using parallelization on a distributed computing system, it provides a solution for handling teravoxel-sized or larger datasets that cannot be processed on a single workstation in a reasonable time. Using experimental data, the package is shown to provide good quality three-dimensional reconstruction for centimetre-sized samples with sub-micrometre pixel size.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ethernet-based flash ADC for a plant PET detector system

We have developed a flash analog to digital (ADC) based read out system to be used for a Positron Emission Tomography (PET) system. The custom designed 16 channel 12-bit Ethernet-based flash ADC (EFADC-16) unit operates at 250 MHzls/channel utilizing a gigabit Ethernet interface to parse time-stamped event signals. Each unit allows the user to define a custom coincidence table for triggering. Each EFADC-16 unit can digitize four H8500 position sensitive photomultiplier tubes (PSPMT) equipped with a Jefferson Lab designed 4 channel resistive readout (a total of 16 channels). We present initial performance results of the EFADC-16 with four PET detector modules in a plant biology application to acquire tomographic images of the translocation of {sup 11}C within an oak seedling.

42 ENGINEERING↗

Direct three-dimensional coherently scattered x-ray microtomography

Purpose: It has been shown that coherently scattered x rays can be used to discriminate and identify specific components in a mixture of low atomic weight materials. The authors demonstrated a new method of doing coherently scattered x-ray tomography with a thin sheet of x ray. Methods: A collimated x-ray fan-beam, a parallel polycapillary collimator, and a phantom consisting of several biocompatible materials of low attenuation-based contrast were used to investigate the feasibility of the method. Because of the particular experimental setup, only the phantom translation perpendicular to the x-ray beam is needed and, thus, there is no need of Radon-type tomographic reconstruction, except for the correction of the attenuation to the primary and scattered x rays, which was performed by using a conventional attenuation-based tomographic image data set. The coherent scatter image contrast changes with momentum transfer among component materials in the specimen were investigated with multiple x-ray sources with narrow bandwidth spectra generated with anode and filter combinations of Cu/Ni (8 keV), Mo/Zr (18 keV), and Ag/Pd (22 keV) and at multiple scatter angles by orienting the detector and polycapillary collimator at different angles to the illuminating x ray. Results: The contrast among different materials changes with the x-ray source energy and the angle at which the image was measured. The coherent scatter profiles obtained from the coherent scatter images are consistent with the published results. Conclusions: This method can be used to directly generate the three-dimensional coherent scatter images of small animal, biopsies, or other small objects with low atomic weight biological or similar synthetic materials with low attenuation contrast. With equipment optimized, submillimeter spatial resolution may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗

SU-E-I-07: An Improved Technique for Scatter Correction in PET

Purpose: In positron emission tomography (PET), the single scatter simulation (SSS) algorithm is widely used for scatter estimation in clinical scans. However, bias usually occurs at the essential steps of scaling the computed SSS distribution to real scatter amounts by employing the scatter-only projection tail. The bias can be amplified when the scatter-only projection tail is too small, resulting in incorrect scatter correction. To this end, we propose a novel scatter calibration technique to accurately estimate the amount of scatter using pre-determined scatter fraction (SF) function instead of the employment of scatter-only tail information. Methods: As the SF depends on the radioactivity distribution and the attenuating material of the patient, an accurate theoretical relation cannot be devised. Instead, we constructed an empirical transformation function between SFs and average attenuation coefficients based on a serious of phantom studies with different sizes and materials. From the average attenuation coefficient, the predicted SFs were calculated using empirical transformation function. Hence, real scatter amount can be obtained by scaling the SSS distribution with the predicted SFs. The simulation was conducted using the SimSET. The Siemens Biograph™ 6 PET scanner was modeled in this study. The Software for Tomographic Image Reconstruction (STIR) was employed to estimate the scatter and reconstruct images. The EEC phantom was adopted to evaluate the performance of our proposed technique. Results: The scatter-corrected image of our method demonstrated improved image contrast over that of SSS. For our technique and SSS of the reconstructed images, the normalized standard deviation were 0.053 and 0.182, respectively; the root mean squared errors were 11.852 and 13.767, respectively. Conclusion: We have proposed an alternative method to calibrate SSS (C-SSS) to the absolute scatter amounts using SF. This method can avoid the bias caused by the insufficient tail information and therefore improve the accuracy of scatter estimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-595: Design of a Graphical User Interface for An In-House Monte Carlo Based Treatment Planning System: Planning and Contouring Tools

Purpose: An in-house Monte Carlo based treatment planning system (MC TPS) has been developed for modulated electron radiation therapy (MERT). Our preliminary MERT planning experience called for a more user friendly graphical user interface. The current work aimed to design graphical windows and tools to facilitate the contouring and planning process. Methods: Our In-house GUI MC TPS is built on a set of EGS4 user codes namely MCPLAN and MCBEAM in addition to an in-house optimization code, which was named as MCOPTIM. Patient virtual phantom is constructed using the tomographic images in DICOM format exported from clinical treatment planning systems (TPS). Treatment target volumes and critical structures were usually contoured on clinical TPS and then sent as a structure set file. In our GUI program we developed a visualization tool to allow the planner to visualize the DICOM images and delineate the various structures. We implemented an option in our code for automatic contouring of the patient body and lungs. We also created an interface window displaying a three dimensional representation of the target and also showing a graphical representation of the treatment beams. Results: The new GUI features helped streamline the planning process. The implemented contouring option eliminated the need for performing this step on clinical TPS. The auto detection option for contouring the outer patient body and lungs was tested on patient CTs and it was shown to be accurate as compared to that of clinical TPS. The three dimensional representation of the target and the beams allows better selection of the gantry, collimator and couch angles. Conclusion: An in-house GUI program has been developed for more efficient MERT planning. The application of aiding tools implemented in the program is time saving and gives better control of the planning process.

60 APPLIED LIFE SCIENCES↗