Intelligent Experiments Through Real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and Future EIC Detectors (Final Report)

The overall vision of this project was to integrate real-time artificial intelligence (AI) directly into the data acquisition and detector-control systems of nuclear physics experiments, including both fast online event selection and an autonomous detector-control feedback loop. The work carried out under the award focused on the fast online event-selection half of that vision: the efficient recording of low-momentum heavy-flavor (HF) hadron decays in proton-proton collisions at the sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)—an observable that requires fast tracking and topological trigger selection not previously demonstrated at RHIC, and that is essential for QCD studies at future facilities such as the Electron-Ion Collider (EIC). The autonomous detector-control (GPU-based feedback) component named in the project title remained a design concept and was not implemented under this award. The Massachusetts Institute of Technology (MIT) group led the offline simulation and data processing needed to train the machine-learning (ML) models, the translation of trained models to Field-Programmable Gate Array (FPGA) firmware using the hls4ml framework, and the physics validation of heavy-flavor reconstruction. Over the award period, the team developed and hardware-tested the principal components of an AI-based heavy-flavor trigger on simulated and recorded sPHENIX tracker data: a software Bipartite Graph Attention Network (BiGAT) trigger model reaching > 95% signal efficiency at 99% background rejection; an FPGA-native hit clusterizer matching the offline clustering; smaller networks synthesized to FPGA within the required sub-10 µs latency; and an assembled decoder–clusterizer–inference firmware chain exercised on the FELIX readout board. A complete, fully integrated hardware demonstrator was not finished within the award period. This report documents the project goals, the MIT group’s contributions, the technical accomplishments, and the outlook toward applications at the future EIC ePIC detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fabrication and Characterization of Superconducting NbN Nanowire Single Photon Detectors

We report on the fabrication and characterization of high-speed, single photon detectors using superconducting NbN nanowires at a wavelength of 1064 nm. A 15 by 15 micron detector with a detector efficiency of 40% has been measured. Due to kinetic inductance, the recovery time of such large area detectors is longer than that of smaller or single wire detectors. The recovery time of our detectors (50 ns) has been characterized by measuring the inter-arrival time statistics of our detector.

single proton detectors↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fabrication and Characterization of Superconducting NbN Nanowire Single Photon Detectors

This viewgraph presentation describes the fabrication of large area superconducting Niobium Nitride nanowire single photon detectors. The topics include: 1) Introduction and Motivation; 2) Operation of SNSPD Detectors; 3) NbTiN Deposition; 4) Fabrication Details; 5) Backside Coupled SNSPD; 6) Measurement Apparatus; 7) Electrical Response of a 15x15 micrometer SNSPD to 1064nm radiation; 8) Detector Efficiency vs Bias Current; 9) Interarrival Time Plot; 10) Detector Linearity; and 11) Conclusion.

single proton dectectors↗

Kubernetes for the Deep Underground Neutrino Experiment Data Acquisition

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino experiment based in the USA which is expected to start taking data in 2029. DUNE aims to precisely measure neutrino oscillation parameters by detecting neutrinos from the LBNF beamline (Fermilab) at the Far Detector, 1,300 kilometres away, in South Dakota at the Sanford Underground Research Facility. The Far Detector will consist of four cryogenic Liquid Argon Time Projection Chamber detectors of 17 kT, each producing more than 1 TB/sec of data. The main requirements for the data acquisition system are the ability to run continuously for extended periods of time, with a 99% up-time requirement, and the functionality to record both beam neutrinos and low energy neutrinos from the explosion of a neighbouring supernova, should one occur during the lifetime of the experiment. The key challenges are the high data rates that the detectors generate and the deep underground environment, which places constraints on power and space. To overcome these challenges, DUNE plans to use a highly optimised C++ software suite and a server farm of about 110 nodes continuously running about two hundred multicore processes located close to the detector, 1.5 kilometres underground. Thirty nodes will be at the surface and will run around two hundred processes simultaneously. DUNE is studying the use of the Kubernetes framework to manage containerised workloads and take advantage of its resource definitions and high up-time services to run the DAQ system. Progress in deploying these systems at the CERN neutrino platform on the prototype DUNE experiments is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗

Vacuum UV performance of silicon detectors

The sensitivity, time-varying response, and spatial sensitivity of four silicon detectors of vacuum UV were measured by passing a typical flux of 3 x 10 photons/s at the Lyman alpha line of 1215.7 A through an exit aperture of 0.55 mm x 0.8 mm. The detectors tested were: (1) a Fairchild FPM 200 silicon planar passivated photodiode with the window removed so that radiation could directly impinge on the center of the 1.0 mm square silicon chip, (2) a Fairchild FPM 100 silicon NPN planar passivated phototransistor, (3) the Hewlett-Packard 5082-4204 silicon planar PIN photodiode, and (4) the United Detector Technology PIN Spot/2 special sensitive silicon Schottky surface photodiode with the window removed.

Ohlhaber, R. L.↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Gravity and Extreme Magnetism SMEX

Gas accreting ont,o black holes and neutron stars form a dynamic system generating X-rays with spectroscopic signatures and varying on time scales determined by the system. The radiation from various parts of these systems is surely polarized and compact sources have been calculated to give rise to net polarization from the unresolved sum of the radiation from the systems. Polarization has been looked to for some time as also bearing the imprint of strong gravity and providing complementary information that could resolve ambiguities between the physical models that can give rise to frequencies, time delays, and spectra. In the cases of both stellar black holes and supermassive black holes the net polarizations predicted for probable disk and corona models are less than 10 needed. This sensitivity can be achieved, even for sources as faint as 1 milliCrab, in the Gravity and Extreme Magnetism SMEX (GEMS) mission that uses foil mirrors and Time Projection Chamber detectors. Similarities have been pointed out between the timing and the spectral characteristics of low mass X-ray binaries and stellar black hole sources. Polarization measurements for these sources could play a role in determining the configuration of the disk and the neutron star.

Swank, Jean↗

Field-Programmable Gate Array Implementation of a Single Photon-Counting Receive Modem

We present a field-programmable gate array (FPGA) implementation of a single photon-counting receive modem for a pulse position modulated signal. The modem is compliant with the Consultative Committee for Space Data Systems (CCSDS) High Photon Efficiency (HPE) Optical Communications Coding and Synchronization standard and is capable of a maximum data rate of 267 Mbps. The system is designed on a commercial off-the-shelf FPGA platform and utilizes superconducting nanowire single photon counting detectors, analog to digital converters (ADC s) to sample the detectors, and two FPGAs. Symbol timing recovery, photon counting, convolutional deinterleaving, and codeword synchronization areis performed in the first FPGA. The second FPGA performs iterative decoding on each codeword of the serially concatenated pulse position modulated (SCPPM) signal. A digital filter is included to compensate for timing jitter of the detector, and the decoder throughput can be modified adjusted through reconfigurable parallelization. The decoder also implements a resource-efficient, algorithmic polynomial interleaver and deinterleaver. Both FPGAs can be reconfigured to switch between pulse position modulation (PPM)-16 and PPM-32 with code rates 1/3, 1/2, and 2/3. In this paper, we describe the receiver architecture and FPGA implementation of the timing recovery loop and SCPPM decoder, FPGA utilization for the different modes, and receive modem characterization test results.

Field-programmable Gate Array↗

Characterization of High Speed Optical and Magnetic Interactions in Superconducting Nanowire Single Photon Detectors

Single-photon detectors are essential tools for quantum photonics. The ideal single photon detector would exhibit a quantum efficiency (QE) of 100% (i.e. no false negatives), zero dark photon counts per second (i.e. no false positives), zero dead time (i.e. the detector is capable of detecting one photon immediately after another), and zero jitter (i.e. the electrical signal produced by the detector perfectly reproduces the timing of the input photon signal). Commercially available avalanche photodiodes (APDs) have generally performed reasonably well for visible wavelengths but they perform poorly at longer wavelengths. For wavelengths spanning the near- ultraviolet (UV) to the mid- infrared (IR), superconducting nanowire single photon detectors (SNSPDs) can exhibit quantum efficiencies exceeding 90% with dark count rates and timing jitter roughly an order of magnitude less than is typically seen in APDs. While SNSPDSs are now commercially available from several small businesses, fundamental questions about the nature of photon interactions with superconducting nanostructures remain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Update on MicroBooNE’s Inclusive Single Photon Low Energy Excess Search

The MicroBooNE detector is a Liquid Argon Time Project Chamber (LArTPC) detector whose primary design goal is to understand the "low-energy-excess" anomaly seen by MiniBooNE. MicroBooNE's currently published results see no excess consistent with the MiniBooNE observation, emphasizing a need for improved searches in more channels. This note summarizes MicroBooNE's inclusive single photon selection using Wire-Cell reconstruction and pattern recognition, which is used to search for a low-energy-excess (LEE) anomaly in the inclusive single photon channel. The selection is similar to the Wire-Cell inclusive electron neutrino selection, but with a different signal definition and some modifications and additions to the pattern recognition tools. A selection with 7.0% efficiency and 40.2% purity is achieved for our targeted single photon signal simulated events.

43 PARTICLE ACCELERATORS↗

SPT-3G D1: Maps of the millimeter-wave sky from 2019 and 2020 observations of the SPT-3G Main field

Maps of the sky in millimeter wavelengths contain rich information on cosmology through anisotropies of the cosmic microwave background (CMB). Creating multifrequency sky maps of anisotropies in the $I$, $Q$, and $U$ Stokes parameters is one of the first steps of CMB cosmology analyses. In this work, we describe the production and validation of a set of sky maps from the South Pole Telescope's third-generation camera, SPT-3G. The maps are from data taken in frequency bands centered at 95, 150, and 220 GHz and taken during the first two years, 2019 and 2020, of the SPT-3G Main survey, which covers $4\%$ of the sky. We applied high-pass filters to time series of individual detectors and binned the filtered time series samples into map pixels. After that, we calibrated and cleaned the maps to reduce known systematic errors. In addition, we searched for other systematic errors through null tests and mitigated a significant systematic error detected therein. The white noise levels of the full-depth maps of the $I$ Stokes parameter are $5.4$, $4.4$, and $16.2$$\mathrm{μK}$-$\mathrm{arcmin}$ in the 95, 150, and 220 GHz bands, respectively, and $8.4$, $6.6$, and $25.8$$\mathrm{μK}$-$\mathrm{arcmin}$ for $Q/U$. These maps are the deepest to date used for measurements of mid-to-high-$\ell$ primary temperature and $E$-mode polarization CMB anisotropies, and reconstructions of the CMB gravitational lensing potential. We make these maps and supporting data products publicly accessible.

Quan, W. [Argonne (main); Chicago U., EFI; Chicago↗

The First Multichroic Polarimeter Array on the Atacama Cosmology Telescope: Characterization and Performance

The Atacama Cosmology Telescope Polarimeter (ACTPol) is a polarization sensitive receiver for the 6-meter Atacama Cosmology Telescope (ACT) and measures the small angular scale polarization anisotropies in the cosmic microwave background (CMB). The full focal plane is composed of three detector arrays, containing over 3000 transition edge sensors (TES detectors) in total. The first two detector arrays, observing at 146 gigahertz, were deployed in 2013 and 2014, respectively. The third and final array is composed of multichroic pixels sensitive to both 90 and 146 gigahertz and saw first light in February 2015. Fabricated at NIST, this dichroic array consists of 255 pixels, with a total of 1020 polarization sensitive bolometers and is coupled to the telescope with a monolithic array of broad-band silicon feedhorns. The detectors are read out using time-division SQUID multiplexing and cooled by a dilution refrigerator at 110 meter Kelvins. We present an overview of the assembly and characterization of this multichroic array in the lab, and the initial detector performance in Chile. The detector array has a TES detector electrical yield of 85 percent, a total array sensitivity of less than 10 microns Kelvin root mean square speed, and detector time constants and saturation powers suitable for ACT CMB observations.

Ho, S. P.↗

Ultrafast UV AlGaN Metal–Semiconductor–Metal Photodetector With a Response Time Below 25 ps

Here, aluminum-gallium-nitride photodetectors were successfully fabricated with micrometer-scale metal–semiconductor–metal structures and tested with ultrafast, UV laser pulses. The measurements were performed with single-shot oscilloscopes. Pulse-broadening effects caused by the measurement system were systematically evaluated and reduced to resolve the intrinsic response time of the detector. The best-performing devices showed a response time of below 25 ps and dark currents below 20 pA. The devices showed linear response with the bias voltage and the laser energy

42 ENGINEERING↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Low-energy Ionization Signals in Silicon Detectors for the Nab Experiment

The Nab (Neutron a b) experiment is designed to measure the beta-antineutrino angular correlation in free neutron 𝛽 decay with an ultimate precision goal of 0.1%, providing input for tests of Cabibbo-Kobayashi-Maskawa matrix unitarity. This measurement is performed via detection of electrons and protons in delayed coincidence using custom large-area segmented silicon detectors. We present the characterization of one such detector system to establish the proton energy and timing response, using a dedicated proton accelerator. The detected proton peak was studied for 25, 30, and 35 keV incident protons on a set of detector segments and multiple cooling cycles over a one-year period. Ionization losses were consistent with models of the detector dead layer with thicknesses less than 100 nm. The detected proton peak was stable within the uncertainty from energy calibration (0.25 keV). The rise times of detector pulses from 109Cd and 113Sn conversion electron sources were used to extract the impurity density profile and establish a precise model for the detector timing response. The observed impurity density profile varied from (2±2)×109/cm3 at the center to (26±2)×109/cm3 at the edge. This impurity density profile was then used to characterize systematic effects in proton time-of-flight measurements due to detector pulse-shape effects; the resultant proton timing systematic uncertainties were below 0.3 ns, which is sufficient for the Nab experiment.

Taylor, RJ [North Carolina State University]↗