Gigabit Satellite Network for NASA's Advanced Communication Technology Satellite (ACTS)

The advanced communication technology satellite (ACTS) gigabit satellite network provides long-haul point-to-point and point-to-multipoint full-duplex SONET services over NASA's ACTS. at rates up to 622 Mbit/s (SONET OC-12), with signal quality comparable to that obtained with terrestrial fiber networks. Data multiplexing over the satellite is accomplished using time-division multiple access (TDMA) techniques coordinated with the switching and beam hopping facilities provided by ACTS. Transmissions through the satellite are protected with Reed-Solomon encoding. providing virtually error-free transmission under most weather conditions. Unique to the system are a TDMA frame structure and satellite synchronization mechanism that allow: (a) very efficient utilization of the satellite capacity: (b) over-the-satellite dosed-loop synchronization of the network in configurations with up to 64 ground stations: and (c) ground station initial acquisition without collisions with existing signalling or data traffic. The user interfaces are compatible with SONET standards, performing the function of conventional SONET multiplexers and. as such. can be: readily integrated with standard SONET fiber-based terrestrial networks. Management of the network is based upon the simple network management protocol (SNMP). and includes an over-the-satellite signalling network and backup terrestrial internet (IP-based) connectivity. A description of the ground stations is also included.

Hoder, Douglas↗

Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration

The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.

J. S. Adams↗

Hyperspectral X-ray Imaging with TES Detectors for Nanoscale Chemical Speciation Mapping

We are developing an imaging capability (“Hyperspectral X-ray Imaging”) for mapping chemical information (molecular formula, phase, oxidation state, hydration) that is based on ultra-high-resolution X-ray emission spectroscopy with large transition-edge sensor microcalorimeter arrays in the scanning electron microscope. By combining microcalorimeter arrays with hundreds of pixels, high-bandwidth microwave frequency-division multiplexing, and fast digital electronics for near real-time data processing, our goal is to enable measurements using laboratory-scale instrumentation rather than synchrotron beamlines. Our application focus here is on mapping the chemical form of uranium compounds on the nanoscale. Furthermore, we will present our approach to developing the Hyperspectral X-ray Imaging capability, progress toward a 128-pixel microwave multiplexed X-ray fluorescence instrument at LANL, and the path to high-throughput nanoscale chemical mapping.

47 OTHER INSTRUMENTATION↗

Transmon qubit readout fidelity at the threshold for quantum error correction without a quantum-limited amplifier

Abstract High-fidelity and rapid readout of a qubit state is key to quantum computing and communication, and it is a prerequisite for quantum error correction. We present a readout scheme for superconducting qubits that combines two microwave techniques: applying a shelving technique to the qubit that reduces the contribution of decay error during readout, and a two-tone excitation of the readout resonator to distinguish among qubit populations in higher energy levels. Using a machine-learning algorithm to post-process the two-tone measurement results further improves the qubit-state assignment fidelity. We perform single-shot frequency-multiplexed qubit readout, with a 140 ns readout time, and demonstrate 99.5% assignment fidelity for two-state readout and 96.9% for three-state readout–without using a quantum-limited amplifier.

Chen, Liangyu (ORCID:0000000250722445)↗

Optimal reference genes for RNA tissue analysis in small animal models of hemorrhagic fever viruses

Abstract Reverse-transcription quantitative polymerase chain reaction assays are frequently used to evaluate gene expression in animal model studies. Data analyses depend on normalization using a suitable reference gene (RG) to minimize effects of variation due to sample collection, sample processing, or experimental set-up. Here, we investigated the suitability of nine potential RGs in laboratory animals commonly used to study viral hemorrhagic fever infection. Using tissues (liver, spleen, gonad [ovary or testis], kidney, heart, lung, eye, brain, and blood) collected from naïve animals and those infected with Crimean–Congo hemorrhagic fever (mice), Nipah (hamsters), or Lassa (guinea pigs) viruses, optimal species-specific RGs were identified based on five web-based algorithms to assess RG stability. Notably, the Ppia RG demonstrated stability across all rodent tissues tested. Optimal RG pairs that include Ppia were determined for each rodent species ( Ppia and Gusb for mice; Ppia and Hrpt for hamsters; and Ppia and Gapdh for guinea pigs). These RG pair assays were multiplexed with viral targets to improve assay turnaround time and economize sample usage. Finally, a pan-rodent Ppia assay capable of detecting Ppia across multiple rodent species was developed and successfully used in ecological investigations of field-caught rodents, further supporting its pan-species utility.

Davies, Katherine A.↗

An ultrasonic scanning system for arterial imaging

A transcutaneous system for real-time imaging of arteries is described. A transducer probe containing three linear arrays of elements scans tissues within the element Fresnel zones. Each element is multiplexed in turn to a pulsed Doppler processor to permit real-time visualizations of moving targets. Applications of the motion-indicating B-scans are discussed, with special attention to problems in transcutaneous measurement of blood flow.

Hottinger, C. F.↗

Telemetry Computer System at Wallops Flight Center

This paper describes the Telemetry Computer System in operation at NASA's Wallops Flight Center for real-time or off-line processing, storage, and display of telemetry data from rockets and aircraft. The system accepts one or two PCM data streams and one FM multiplex, converting each type of data into computer format and merging time-of-day information. A data compressor merges the active streams, and removes redundant data if desired. Dual minicomputers process data for display, while storing information on computer tape for further processing. Real-time displays are located at the station, at the rocket launch control center, and in the aircraft control tower. The system is set up and run by standard telemetry software under control of engineers and technicians. Expansion capability is built into the system to take care of possible future requirements.

Bell, H.↗

Multiplex Detection of Multiple-Quantum/Single-Quantum NMR Correlation Spectra

High-ordered multiple-quantum coherences have been used to gauge the size of coupled networks of nuclear spins but are seldom used in modern high-resolution solid-state NMR spectroscopy due to the low resolution of earlier techniques. Herein, we extend this work to the third dimension by designing an MQ spin counting experiment with full chemical resolution of the nuclei involved in the coherences. The technique uses multiplex processing to simultaneously acquire MQ/1Q correlation 2D spectra, with all even-ordered values of M, in the same amount of time it would take to acquire the 2Q/1Q spectrum alone. Further, we apply this multiplexed MQ/1Q correlation method to probe site clustering on functionalized silica surfaces and find the first evidence of clusters involving three or more functionalities. When applied to a supported zirconium metallocene, the observation of a 6Q coherence between six cyclopentadienyl proton nuclei confirms the colocation of two cyclopentadienyl ligands on a single metal center.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiplexed Predictive Control of a Large Commercial Turbofan Engine

Model predictive control is a strategy well-suited to handle the highly complex, nonlinear, uncertain, and constrained dynamics involved in aircraft engine control problems. However, it has thus far been infeasible to implement model predictive control in engine control applications, because of the combination of model complexity and the time allotted for the control update calculation. In this paper, a multiplexed implementation is proposed that dramatically reduces the computational burden of the quadratic programming optimization that must be solved online as part of the model-predictive-control algorithm. Actuator updates are calculated sequentially and cyclically in a multiplexed implementation, as opposed to the simultaneous optimization taking place in conventional model predictive control. Theoretical aspects are discussed based on a nominal model, and actual computational savings are demonstrated using a realistic commercial engine model.

Richter, hanz↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Operation of Arrays of TES x-ray Microcalorimeters Suitable for Constellation-X

Having already developed a transition-edge-sensor (TES) microcalorimeter design that enables uniform and reproducible high spectral resolution (routinely better than 3 eV resolution at 6 keV) and is compatible with high fill-factor arrays, we are now working towards demonstrating this performance at high count rates and with the multiplexed read-out needed for instrumenting the Constellation-X X-ray Microcalorimeter Spectrometer (XMS) focal plane array. Design changes that increase the speed of the individual XMS pixels, such as lowering the heat capacity or increasing the thermal conductance of the link to the 50-mK heatsink, result in larger, faster signals, thus the coupling to the multiplexer and the overall bandwidth of the electronics must accommodate this increase in slew rate. In order to operate the array with high incident x-ray flux without unacceptable degradation of the spectral resolution, the magnitude of thermal and electrical crosstalk must be controlled. We will discuss recent progress in the thermal and electrical designs of our close-packed TES arrays, and we will present spectra acquired through the read-out chain from the multiplexer electronics, through the demultiplexer software, to real-time signal processing.

Kilbourne, C. A.↗

Television multiplexing system

System with single, standard, wideband line transmits ten or more real time TV video data displays over hard wire to recorders more than 22.5 km from source. Digital logic and integrated circuits ensure high reliability and low maintenance. System is adaptable for video sampling applications.

Simpkins, L. G.↗

MCS+: An Efficient Algorithm for Crawling the Community Structure in Multiplex Networks

In this article, we consider the problem of crawling a multiplex network to identify the community structure of a layer-of-interest. A multiplex network is one where there are multiple types of relationships between the nodes. In many multiplex networks, some layers might be easier to explore (in terms of time, money etc.). We propose MCS+, an algorithm that can use the information from the easier to explore layers to help in the exploration of a layer-of-interest that is expensive to explore. We consider the goal of exploration to be generating a sample that is representative of the communities in the complete layer-of-interest. This work has practical applications in areas such as exploration of dark (e.g., criminal) networks, online social networks, biological networks, and so on. For example, in a terrorist network, relationships such as phone records, e-mail records, and so on are easier to collect; in contrast, data on the face-to-face communications are much harder to collect, but also potentially more valuable. We perform extensive experimental evaluations on real-world networks, and we observe that MCS+ consistently outperforms the best baseline—the similarity of the sample that MCS+ generates to the real network is up to three times that of the best baseline in some networks. We also perform theoretical and experimental evaluations on the scalability of MCS+ to network properties, and find that it scales well with the budget, number of layers in the multiplex network, and the average degree in the original network.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A CCD integrated circuit for transient recorders

A 50 MHz CCD integrated circuit is described that was developed for use in transient analog signal recorders to sample and time expand transient signals. The integrated circuit achieves an effective 200 MHz sample rate by using four 32 stage peristaltic CCDs to sample the transient signal four times each clock period. Dual frequency, 4 phi clocking is used to sample and time expand the sampled data. The output signals of the four CCDs are multiplexed on chip into a single low frequency output data line. When operated with 50 MHz/165 KHz 4 phi clocks, this circuit has a 200 MHz sample rate, a record length of 640 nanoseconds, a time expansion factor of 303, and overall signal to noise ratio of 40:1. The signal to noise ratio is limited by fixed pattern noise of the four CCDs.

Balch, J. W.↗

UV Capabilities of the CETUS Multi-Object Spectrometer (MOS) and NUV/FUV Camera

The Cosmic Evolution Through UV Spectroscopy (CETUS) concept enables parallel observations by the UV multiobject spectrometer (MOS) and near-UV/far-UV camera which operate simultaneously but independently with their separate field of views. The near-UV MOS can target up to 100 objects at a time without confusion with nearby sources or background zodiacal light. This multiplexing will allow over 100,000 galaxies to be observed over a typical mission lifetime. The MOS includes a next-generation micro-shutter array (NGMSA), an efficient aspheric Offner-like spectrometer design with a convex grating, and nanotube light traps for suppressing unwanted wavelengths. The NUV/FUV Camera has the capability to image in a range of sub-bands from 115-400 nm at the same time the MOS is operating at 180-350 nm. The UV camera has a similar Offner-like relay, selectable filters, and two separate detectors to optimize observing in either the far-UV (115-175 nm) or the near-UV (180-400 nm) utilizing a CsI Micro-Channel Plate detector (MCP) and a CCD respectively.

The Cosmic Evolution Through UV Spectroscopy (CETU↗

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuclear facilities and analytical laboratories. With approximately ten times better energy resolution than high-purity germanium detectors, these instruments can overcome important uncertainty limits. Microcalorimeter gamma spectroscopy is intended to provide nondestructive isotopic analysis capabilities with sufficient precision and accuracy to reduce the need for sampling, chemical separations, and mass spectrometry to meet safeguards and security goals. Key milestones were the development of the SOFIA instrument (Spectrometer Optimized for Facility Integrated Applications) and the SAPPY software (Spectral Analysis Program in PYthon). SOFIA is a compact instrument that combines advances in large multiplexed transition-edge sensor arrays with optimized cryogenic performance to overcome many practical limitations of previous systems. With a 256-pixel multiplexed detector array capable of 5,000 counts per second, measurement time can be comparable to high-purity germanium detectors. SAPPY was developed to determine isotopic ratios in data from SOFIA and other microcalorimeter instruments with an approach similar to the widely-used FRAM software. SAPPY provides a flexible framework with rigorous uncertainty analysis for both microcalorimeter and high purity germanium (HPGe) data, allowing direct comparison. Here, we present current results from the SOFIA instrument, preliminary isotopic analysis using SAPPY, and describe how the technology is being used to explore uncertainty limits of nondestructive isotopic characterization, inform safeguards models, and extract improved nuclear data including gamma-ray branching ratios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2024 Milestone Report: Site 300 mPDV Optical Fiducials

In the early 2000s Photon Doppler Velocimetry (PDV) replaced the Fabry-Perot many beam system1 and has since become ubiquitous across dynamic experimental platforms to measure velocity and event times such as shock breakout, key variables for high pressure physics research. The advent of optically multiplexed oscilloscope channels to create multiplexed PDV (mPDV) increased portability and reduced price per data point. However, these advantages came with the cost of additional fielding complexity and thermally induced timing drift, which directly affects the ability to use PDV for high precision time measurement. Controlling the temperature or incorporating optical fiducials allows researchers to characterize, reduce, and correct this thermal drift in analysis. Our implemented optical fiducial or “timing marker” allows us to reduce thermal drift uncertainty from the 10s of nanoseconds down to the 100s of picoseconds with minimal added complexity to existing systems. The implementation of this timing marker normalizes uncertainty across optical delays, brings our facility cross timing into the sub nanosecond regime and lets us identify/study anomalies in our data. This improvement increases experiment reliability and quality enabling a new class of high precision experiments at S300.

42 ENGINEERING↗

Optical linear algebra processors - Architectures and algorithms

Attention is given to the component design and optical configuration features of a generic optical linear algebra processor (OLAP) architecture, as well as the large number of OLAP architectures, number representations, algorithms and applications encountered in current literature. Number-representation issues associated with bipolar and complex-valued data representations, high-accuracy (including floating point) performance, and the base or radix to be employed, are discussed, together with case studies on a space-integrating frequency-multiplexed architecture and a hybrid space-integrating and time-integrating multichannel architecture.

Casasent, David↗