Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Real time observation of binder jetting printing process using high-speed X-ray imaging

A high-speed synchrotron X-ray imaging technique was used to investigate the binder jetting additive manufacturing (AM) process. A commercial binder jetting printer with droplet-on-demand ink-jet print-head was used to print single lines on powder beds. The printing process was recorded in real time using high-speed X-ray imaging. The ink-jet droplets showed distinct elongated shape with spherical head, long tail, and three to five trailing satellite droplets. Significant drift was observed between the impact points of main droplet and satellite droplets. The impact of the droplet on the powder bed caused movement and ejection of the powder particles. The depth of disturbance in the powder bed from movement and ejection was defined as interaction depth, which is found to be dependent on the size, shape, and material of the powder particles. For smaller powder particles (diameter less than 10 μm), three consecutive binder droplets were observed to coalesce to form large agglomerates. As a result, the observations reported here will facilitate the understanding of underlying physics that govern the binder jetting processes, which will then help in improving the quality of parts manufactured using this AM process.

42 ENGINEERING↗

In Situ Observation of Adiabatic Shear Band Formation in Aluminum Alloys

We used high-speed X-ray phase contrast imaging and infrared thermal imaging techniques to study the formation processes of adiabatic shear bands in aluminum 7075-T6 and 6061-T6 alloys. A modified compression Kolsky bar setup was used to apply the dynamic loading. A flat hatshaped specimen design was adopted for generating the shear bands at the designated locations. Experimental results show that 7075-T6 exhibits less ductility and a narrower shear band than 6061-T6. Maximum temperatures of 720 K and 770 K were locally determined within the shear band zones for 7075-T6 and 6061-T6 respectively. This local high temperature zone and the resulting thermal instability were found to relate to the shear band formation in these aluminum alloys.

36 MATERIALS SCIENCE↗

Particle clustering effects on damage mechanisms in elastomeric syntactic foams

To elucidate the damage mechanisms in syntactic foams with hollow glass microballoon (GMB) reinforcement and elastomer matrices, in situ X-ray computed tomography mechanical testing was performed on syntactic foams with increasing GMB volume fraction. Image processing and digital volume correlation techniques identified very different damage mechanisms compared to syntactic foams with brittle matrices. Specifically, the prevailing mechanism transitioned from dispersed GMB collapse at low volume fraction to clustered GMB collapse at high volume fraction. Moreover, damage initiated and propagated earlier in closely-packed GMBs for all specimens. Both of these trends were attributed to increased interaction between closely-packed GMBs. This was validated by statistical analysis of GMB damage, which identified a consistent, inverse relationship among the probability of survival and the local coordination number (N neighbor ) across all specimens.

42 ENGINEERING↗

Probing multiscale dissolution dynamics in natural rocks through microfluidics and compositional analysis

Mineral dissolution significantly impacts many geological systems. Carbon released by diagenesis, carbon sequestration, and acid injection are examples where geochemical reactions, fluid flow, and solute transport are strongly coupled. The complexity in these systems involves interplay between various mechanisms that operate at timescales ranging from microseconds to years. Current experimental techniques characterize dissolution processes using static images that are acquired with long measurement times and/or low spatial resolution. These limitations prevent direct observation of how dissolution reactions progress within an intact rock with spatially heterogeneous mineralogy and morphology. We utilize microfluidic cells embedded with thin rock samples to visualize dissolution with significant temporal resolution (100 ms) in a large observation window (3 × 3 mm). Here we injected acidic fluid into eight shale samples ranging from 8 to 86 wt % carbonate. The pre- and postreaction microstructures are characterized at the scale of pores (0.1 to 1 µm) and fractures (1 to 1,000 µm). We observe that nonreactive particle exposure, fracture morphology, and loss of rock strength are strongly dependent on both the relative volume of reactive grains and their distribution. Time-resolved images of the rock unveil the spatiotemporal dynamics of dissolution, including two-phase flow effects in real time and illustrate the changes in the fracture interface across the range of compositions. Moreover, the dynamical data provide an approach for characterizing reactivity parameters of natural heterogeneous samples when porous media effects are not negligible. The platform and workflow provide real-time characterization of geochemical reactions and inform various subsurface engineering processes.

58 GEOSCIENCES↗

Alignment and dissociation of electronically excited molecular hydrogen with intense laser fields

The dissociation of aligned, electronically excited H 2 (E,F 1 Σ g + ), followed by ionization of the produced H atom, is analyzed via the velocity mapped imaging technique. The dissociation and ionization processes are accomplished, respectively, by a two- and a onephoton absorption from a single 532-nm laser pulse, while the alignment is induced by a separate 1064-nm laser pulse. The velocity of the produced H + photofragments shows a weak perpendicular alignment at low alignment laser field values, evolving to strongly parallel for larger fields. We modeled this alignment behavior with a simple two-state model involving the Stark mixing of the initially-prepared J = 0 with the J = 2 rotational state. This model is able to reproduce all of the observed angular distribution, and permits us to extract from the fit the polarizability anisotropy of H 2 (E,F) electronic state. We determine this value to be (3.7 ± 1.2) x 10 3 a.u. As this value is extremely large in comparison to what one would expect from the pure H 2 (E,F) electronic state, we hypothesize that this value comes from the 1064-nm laser beam mixing nearby electronic states with the initially laser prepared (E,F) state generating a mixed state (EF**) with an extremely large polarizability anisotropy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sensor Science for National Security

Oak Ridge National Laboratory (ORNL) has over 200 professionals engaged in measurement science research and development. This work includes transduction techniques, advanced microelectronics, signal and image processing, modeling and simulation, material synthesis and characterization, and system engineering issues for packaging, miniaturization, integration, and communications (e.g. wireless networks). ORNL is applying this expertise to detecting, preventing, and reversing the proliferation of weapons of mass destruction, deploying integrated systems for incident awareness, detection, and response, providing technology for detection of explosives, and delivering enhanced protection and new capabilities to first responders and warfighters. Sensor systems include micro- and nano-arrays, optical, chemical, and biological technologies. Electronics research has focused on low-power, low-cost, and wireless functionality. Signal processing advancements encompass data flow with conversion to information and knowledge for intelligent decision making.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Imaging of Al6061 Prepared by Solid-State Friction Stir Additive Manufacturing

Solid-state Friction Stir Additive Manufacturing has recently gained attention as a result of its capacity to fabricate large-scale parts while preserving the mechanical properties of the feedstock material. However, the correlation between the quality of layer-by-layer bonding of the deposited metal and processing parameters has remained unknown. Neutron imaging techniques, with 90% total transmission per cm, are employed for Al6061 parts fabricated by MELD ® Technology as a non-destructive evaluation approach for the first time to investigate the layer-by-layer structure of a stadium-shaped ingot in different sections. The post-processed results show the fabricated parts with an optimized set of processing parameters are void-free. However, the hydrocarbon-based feedstock lubricant segregates between the layers, which consequently may lead to non-uniform weaker mechanical properties along the build direction and stimulate crack initiation during mechanical loading. The tensile test results show 14% lower strain-to-failure values in alleged contaminated areas in transmission imaging results. Additionally, layer bonding is significantly impacted by hot-on-hot and hot-on-cold layer deposition schemes, especially for larger layer thicknesses.

36 MATERIALS SCIENCE↗

Intelligent Computer Vision System for Automated Classification

In this paper we investigate an Intelligent Computer Vision System applied for recognition and classification of commercially available cork tiles. The system is capable of acquiring and processing gray images using several feature generation and analysis techniques. Its functionality includes image acquisition, feature extraction and preprocessing, and feature classification with neural networks (NN). We also discuss system test and validation results from the recognition and classification tasks. The system investigation also includes statistical feature processing (features number and dimensionality reduction techniques) and classifier design (NN architecture, target coding, learning complexity and performance, and training with our own metaheuristic optimization method). The NNs trained with our genetic low-discrepancy search method (GLPtauS) for global optimisation demonstrated very good generalisation abilities. In our view, the reported testing success rate of up to 95% is due to several factors: combination of feature generation techniques; application of Analysis of Variance (ANOVA) and Principal Component Analysis (PCA), which appeared to be very efficient for preprocessing the data; and use of suitable NN design and learning method.

97 MATHEMATICS AND COMPUTING↗

A review of breast tomosynthesis. Part I. The image acquisition process

Mammography is a very well-established imaging modality for the early detection and diagnosis of breast cancer. However, since the introduction of digital imaging to the realm of radiology, more advanced, and especially tomographic imaging methods have been made possible. One of these methods, breast tomosynthesis, has finally been introduced to the clinic for routine everyday use, with potential to in the future replace mammography for screening for breast cancer. In this two part paper, the extensive research performed during the development of breast tomosynthesis is reviewed, with a focus on the research addressing the medical physics aspects of this imaging modality. This first paper will review the research performed on the issues relevant to the image acquisition process, including system design, optimization of geometry and technique, x-ray scatter, and radiation dose. The companion to this paper will review all other aspects of breast tomosynthesis imaging, including the reconstruction process.

60 APPLIED LIFE SCIENCES↗

Image processing tools for petabyte-scale light sheet microscopy data

Light sheet microscopy is a powerful technique for high-speed three-dimensional imaging of subcellular dynamics and large biological specimens. However, it often generates datasets ranging from hundreds of gigabytes to petabytes in size for a single experiment. Conventional computational tools process such images far slower than the time to acquire them and often fail outright due to memory limitations. To address these challenges, we present PetaKit5D, a scalable software solution for efficient petabyte-scale light sheet image processing. This software incorporates a suite of commonly used processing tools that are optimized for memory and performance. Notable advancements include rapid image readers and writers, fast and memory-efficient geometric transformations, high-performance Richardson–Lucy deconvolution and scalable Zarr-based stitching. These features outperform state-of-the-art methods by over one order of magnitude, enabling the processing of petabyte-scale image data at the full teravoxel rates of modern imaging cameras. The software opens new avenues for biological discoveries through large-scale imaging experiments.

97 MATHEMATICS AND COMPUTING↗

Study on efficiency of time computation in x-ray imaging simulation base on Monte Carlo algorithm using graphics processing unit

Monte Carlo (MC) is one of the powerful techniques for simulation in x-ray imaging. MC method can simulate the radiation transport within matter with high accuracy and provides a natural way to simulate radiation transport in complex systems. One of the codes based on MC algorithm that are widely used for radiographic images simulation is MC-GPU, a codes developed by Andrea Basal. This study was aimed to investigate the time computation of x-ray imaging simulation in GPU (Graphics Processing Unit) compared to a standard CPU (Central Processing Unit). Furthermore, the effect of physical parameters to the quality of radiographic images and the comparison of image quality resulted from simulation in the GPU and CPU are evaluated in this paper. The simulations were run in CPU which was simulated in serial condition, and in two GPU with 384 cores and 2304 cores. In simulation using GPU, each cores calculates one photon, so, a large number of photon were calculated simultaneously. Results show that the time simulations on GPU were significantly accelerated compared to CPU. The simulations on the 2304 core of GPU were performed about 64 -114 times faster than on CPU, while the simulation on the 384 core of GPU were performed about 20 – 31 times faster than in a single core of CPU. Another result shows that optimum quality of images from the simulation was gained at the history start from 10{sup 8} and the energy from 60 Kev to 90 Kev. Analyzed by statistical approach, the quality of GPU and CPU images are relatively the same.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

COE Task Order 4. Final Report: Automated Threat Recognition

Lawrence Livermore National Laboratory (LLNL) was tasked by the Department of Homeland Security (DHS) Science and Technology Directorate (S&T) with developing an automated target recognition algorithm for finding objects of interest in checked baggage at airports. The project used x-ray computed tomography (CT) data collected on a medical scanner of various simulated checked bags. Target objects of interest include clay, rubber, and saline in various concentrations. The final results are 93.9% probability of detection (P D ) with 11.9% probability of false alarm (PFA) on all targets and 100% detection for pseudo target sheets. This result is achieved by using a three-stage algorithm made up of segmentation, post-processing, and feature extraction and object classification. The segmentation proved to be the most important stage and it involves merging two distinct segmentation results followed by a set of algorithms for cleaning up the merged segmentations. The first segmentation algorithm operates on planar 10x10 voxel slabs (two- dimensional segments) in the three spatial planes. The segmenter calculates a probability that each slab in the image is a part of a target, determines if the probability was above a threshold, and then merges all connected slabs together. The second segmentation algorithm is an ensemble segmenter, which generates a set of possible segmentations through random permutations and computes an average behavior. The distinct properties of these segmenters results in a merged segmentation with superior results than either segmenter alone. The merged segmentation is “cleaned up” using post processing techniques to achieve the final labeled images. The final classification stage made use of a random forest classifier algorithm to discriminate targets from non-targets based on a set of features of the segmented objects partially from the voxel slabs and partially from the individual voxels. Features include standard statistics such as mean, median, and standard deviations of the density, features capturing some aspects of texture, and some features about the surrounding bag structure. In addition to the detection and false alarm results above, we show how the algorithms can be trained to “overfit” to the limited data set provided and achieve near perfect results (P D =100% and P FA =0%). This over-training is not recommended for long-term operation, but instead is meant to demonstrate how test design is an important factor in aviation security. Possible improvements to the algorithm and the testing methodology (including blind testing) are also presented.

42 ENGINEERING↗

Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in resampled out-of-plane views consistently showed the superiority of SRR compared to original axial and coronal image acquisitions. Conclusions: Thick-slice 2D T2-weighted MRI scans are part of many routine clinical protocols due to their high signal-to-noise ratio, but are often severely affected by through-plane partial voluming effects. This study shows that while radiologic assessment is performed in 2D on thick-slice scans, super-resolution MRI reconstruction techniques can be used to fuse those scans to generate a high-resolution image with reduced partial voluming for improved postacquisition processing. Qualitative and quantitative evaluation showed the efficacy of all SRR techniques with the best results obtained from SRR in the image domain. The limitations of SRR techniques are uncertainties in modeling the slice profile, density compensation, quantization in resampling, and uncompensated motion between scans.

60 APPLIED LIFE SCIENCES↗

Real-Time Vehicle-Mounted Multistatic Ground Penetrating Radar Imaging System for Buried Object Detection

A multistatic ground penetrating radar system is described, capable of real-time imaging and object detection. The radar consists of 16 transmitter and receiver pairs mounted across the front of a vehicle. The transmitters operate sequentially with all receivers activated for each transmit pulse. The resulting frame of 256 multistatic time signals is processed into an image using a tomographic reconstruction technique. In this paper we describe the system architecture, signal conditioning, and reconstruction algorithm for producing a sequence of images in real time as the vehicle travels across the ground. We demonstrate a robust image post-processing method that separates the bright spot corresponding to the dominant buried object in an image frame from the background. This is essential before calculating an energy-based statistic for automatic detection of buried objects. This spot ratio detection statistic, based on energy both inside and outside the spot, is shown to be not only more stationary than spot energy (i.e. mostly free of localized trends due to changing ground conditions), but also more powerful as a detection statistic. Finally, we demonstrate that multistatic imaging significantly improves the detection performance over more conventional monostatic array processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray focal spot reconstruction by circular penumbra analysis—Application to digital radiography systems

Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was proven to be effective for simulated images and the results of the experimental test suggest that it could be considered as an alternative technique for focal spot distribution evaluation. The method offers the possibility to measure the actual focal spot size and emission distribution at the same exposure conditions as clinical routine, avoiding high tube loading as in the case of the pin-hole imaging technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Deep sub electron noise readout in CCD systems using digital filtering techniques

Scientific CCDs designed in thick high resistivity silicon (Si) are excellent detectors for astronomy, high energy and nuclear physics, and instrumentation. Many applications can benefit from CCDs ultra low noise readout systems. The present work shows how sub electron noise CCD images can be achieved using digital signal processing techniques. These techniques allow readout bandwidths of up to 10 K pixels per second and keep the full CCD spatial resolution and signal dynamic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extrusion parameter control optimization for DIW 3D printing using image analysis techniques

Material extrusion is a well-recognized facet of additive manufacturing that involves the fabrication of parts through the deposition of structural material from an extrusion head from a bulk supply. In the subdivision of Direct Ink Writing (DIW) additive manufacturing, challenges arise when the structural material is flowable, synchronous extrusion control and tool movement becomes critical for achieving high-quality parts with low defect populations. DIW techniques are most used in laboratory settings using expensive custom instruments and may require specialized 3D slicing software. Here, in this study, the fabrication of an inexpensive, consumer-friendly progressive cavity pump dispensing system is detailed, in which can create high-quality parts by executing G-code commands produced from a commercial slicing software. The precision and repeatability of the movement-synchronized material extrusion is demonstrated through a series of optimization schemes, entailing the alteration of various control parameters, which directly affect the extrusion properties demonstrated during a print. In situ diagnostics were implemented to evaluate the results of the established optimization experiment. Using a machine vision technique, images of the optimization prints are processed. Following this, a supervised machine learning model was trained to autonomously judge whether or not the extrusion parameters produced a passing or failing result. The machine learning scheme serves as a preliminary benchmark for future layer-by-layer evaluation of more complex DIW parts. The construction of the printer and development of in situ characterization capabilities demonstrates the ability for this printer to create high-fidelity DIW parts for a fraction of the price of other systems.

42 ENGINEERING↗