Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT

Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed software was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This study showed that time-resolved dosimetry using an ionization chamber is feasible and can be largely automated which limits the required additional time compared to integrated dose measurements. It provides a unique QA method which enables identification and quantification of the contribution of various error sources during IMRT and VMAT delivery.

60 APPLIED LIFE SCIENCES↗

Finite-size effect on two-particle production in continuous and discrete spectrum

The formalism allowing one to account for the effect of a finite space-time extent of particle production region is given. Its applications to the lifetime measurement of hadronic atoms produced by a high-energy beam in a thin target, as well as to the femtoscopy techniques widely used to measure space-time characteristics of the production processes, are discussed. Particularly, it is found that the neglect of the finite-size effect on the pionium lifetime measurement in the experiment DIRAC at CERN could lead to the lifetime overestimation comparable with the 10% statistical error. The theoretical systematic errors arising in the calculation of the finite-size effect due to the neglect of non-equal emission times in the pair center-of-mass system, the space-time coherence and the residual charge are shown to be negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deterministic Modeling of the High Temperature Test Reactor

Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine INL’s current prismatic reactor deterministic analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 column thin annular core, and the fully loaded core critical condition with 30 columns. Special emphasis is devoted to the annular core modeling, which shares more characteristics with the NGNP base design. The DRAGON code is used in this study because it offers significant ease and versatility in modeling prismatic designs. Despite some geometric limitations, the code performs quite well compared to other lattice physics codes. DRAGON can generate transport solutions via collision probability (CP), method of characteristics (MOC), and discrete ordinates (Sn). A fine group cross section library based on the SHEM 281 energy structure is used in the DRAGON calculations. HEXPEDITE is the hexagonal z full core solver used in this study and is based on the Green’s Function solution of the transverse integrated equations. In addition, two Monte Carlo (MC) based codes, MCNP5 and PSG2/SERPENT, provide benchmarking capability for the DRAGON and the nodal diffusion solver codes. The results from this study show a consistent bias of 2–3% for the core multiplication factor. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bayesian Inference of High-density Nuclear Symmetry Energy from Radii of Canonical Neutron Stars

The radius R 1.4 of neutron stars (NSs) with a mass of 1.4 M ⊙ has been extracted consistently in many recent studies in the literature. Using representative R 1.4 data, we infer high-density nuclear symmetry energy E sym (ρ) and the associated nucleon specific energy E 0 (ρ) in symmetric nuclear matter (SNM) within a Bayesian statistical approach using an explicitly isospin-dependent parametric equation of state (EOS) for nucleonic matter. We found the following. (1) The available astrophysical data can already significantly improve our current knowledge about the EOS in the density range of ρ 0 - 2.5ρ 0 . In particular, the symmetry energy at twice the saturation density ρ 0 of nuclear matter is determined to be E sym (2ρ 0 )=${39.2}_{-8.2}^{+12.1}$ MeV at a 68% confidence level. (2) A precise measurement of R 1.4 alone with a 4% 1σ statistical error but no systematic error will not greatly improve the constraints on the EOS of dense neutron-rich nucleonic matter compared to what we extracted from using the available radius data. (3) The R 1.4 radius data and other general conditions, such as the observed NS maximum mass and causality condition, introduce strong correlations for the high-order EOS parameters. Consequently, the high-density behavior of E sym (ρ) inferred depends strongly on how the high-density SNM EOS E 0 (ρ) is parameterized, and vice versa. (4) Finally, the value of the observed maximum NS mass and whether it is used as a sharp cutoff for the minimum maximum mass or through a Gaussian distribution significantly affects the lower boundaries of both E 0 (ρ) and E sym (ρ) only at densities higher than about 2.5ρ 0 .

79 ASTRONOMY AND ASTROPHYSICS↗

Kinetics of the reaction OH + D yields OD + H

The reaction of OH radicals with D-atoms to form OD has been studied at room temperature in a discharge-flow system utilizing UV resonance fluorescence detection of the molecular species. A rate constant of approximately 1.3 by 10 to the -10th power cu cm per sec is reported where the error limits include systematic error estimates. Astrophysical and kinetic implications are discussed briefly.

Margitan, J. J.↗

Quantification of airport community noise impact in terms of noise levels, population density, and human subjective response

The Fraction Impact Method (FIM), developed by the National Research Council (NRC) for assessing the amount and physiological effect of noise, is described. Here, the number of people exposed to a given level of noise is multiplied by a weighting factor that depends on noise level. It is pointed out that the Aircraft-noise Levels and Annoyance MOdel (ALAMO), recently developed at NASA Langley Research Center, can perform the NRC fractional impact calculations for given modes of operation at any U.S. airport. The sensitivity of these calculations to errors in estimates of population, noise level, and human subjective response is discussed. It is found that a change in source noise causes a substantially smaller change in contour area than would be predicted simply on the basis of inverse square law considerations. Another finding is that the impact calculations are generally less sensitive to source noise errors than to systematic errors in population or subjective response.

Deloach, R.↗

Asteroid approach covariance analysis for the Clementine mission

The Clementine mission is designed to test Strategic Defense Initiative Organization (SDIO) technology, the Brilliant Pebbles and Brilliant Eyes sensors, by mapping the moon surface and flying by the asteroid Geographos. The capability of two of the instruments available on board the spacecraft, the lidar (laser radar) and the UV/Visible camera is used in the covariance analysis to obtain the spacecraft delivery uncertainties at the asteroid. These uncertainties are due primarily to asteroid ephemeris uncertainties. On board optical navigation reduces the uncertainty in the knowledge of the spacecraft position in the direction perpendicular to the incoming asymptote to a one-sigma value of under 1 km, at the closest approach distance of 100 km. The uncertainty in the knowledge of the encounter time is about 0.1 seconds for a flyby velocity of 10.85 km/s. The magnitude of these uncertainties is due largely to Center Finding Errors (CFE). These systematic errors represent the accuracy expected in locating the center of the asteroid in the optical navigation images, in the absence of a topographic model for the asteroid. The direction of the incoming asymptote cannot be estimated accurately until minutes before the asteroid flyby, and correcting for it would require autonomous navigation. Orbit determination errors dominate over maneuver execution errors, and the final delivery accuracy attained is basically the orbit determination uncertainty before the final maneuver.

Ionasescu, Rodica↗

Detection and Correction of Step Discontinuities in Kepler Flux Time Series

PDC 8.0 includes an implementation of a new algorithm to detect and correct step discontinuities appearing in roughly one of every 20 stellar light curves during a given quarter. The majority of such discontinuities are believed to result from high-energy particles (either cosmic or solar in origin) striking the photometer and causing permanent local changes (typically -0.5%) in quantum efficiency, though a partial exponential recovery is often observed [1]. Since these features, dubbed sudden pixel sensitivity dropouts (SPSDs), are uncorrelated across targets they cannot be properly accounted for by the current detrending algorithm. PDC detrending is based on the assumption that features in flux time series are due either to intrinsic stellar phenomena or to systematic errors and that systematics will exhibit measurable correlations across targets. SPSD events violate these assumptions and their successful removal not only rectifies the flux values of affected targets, but demonstrably improves the overall performance of PDC detrending [1].

Kolodziejczak, J. J.↗

Cross-calibration of Imaging Sensors using Model-based, SI-traceable Predictions of At-sensor Radiance

Many inter-consistency efforts force empirical agreement between sensors viewing a source nearly coincident in time and geometry that ensures consistency between sensors rather than obtain an SI-traceable calibration with documented error budgets. The method described here provides interconsistency via absolute radiometric calibration with defensible error budget avoiding systematic errors through prediction of at-sensor radiance for a site viewed by multiple sensors but not necessarily viewed at coincident times. The method predicts spectral radiance over a given surface site for arbitrary view and illumination angles and for any date dominated by clear-sky conditions. The foundation is a model-based, SI-traceable prediction of at-sensor radiance over selected sites based on physical understanding of the surface and atmosphere. The calibration of the ground site will include spatial, spectral, and sunview geometric effects based on satellite and ground-based data. The result is an interconsistency of hyperspectral and multispectral sensors spanning spatial resolutions from meters to kilometers all relative to the surface site rather than a single sensor. The source-centric philosophy of calibrating the site inherently accounts for footprint size mismatch, spectral band mismatch, and temporal and spatial sampling effects. The method for characterizing the test site allows its use for SI-traceable calibration of any sensor that can view the calibrated test site. Interconsistency is obtained through the traceability and error budget rather than coincident views. Such an approach to inter-consistency provides better understanding of biases between sensors as well producing more accurate results with documented SI-traceability that reduces the need for overlapping data sets.

Thome, Kurtis↗

Methods for Detection and Correction of Sudden Pixel Sensitivity Drops

PDC 8.0 includes implementation of a new algorithm to detect and correct step discontinuities appearing in roughly one of every twenty stellar light curves during a given quarter. An example of such a discontinuity in an actual light curve is shown in fig. 1. The majority of such discontinuities are believed to result from high-energy particles (either cosmic or solar in origin) striking the photometer and causing permanent local changes (typically -0.5% in summed apertures) in quantum efficiency, though a partial exponential recovery is often observed. Since these features, dubbed sudden pixel sensitivity dropouts (SPSDs), are uncorrelated across targets they cannot be properly accounted for by the current detrending algorithm. PDC de-trending is based on the assumption that features in flux time series are due either to intrinsic stellar phenomena or to systematic errors and that systematics will exhibit measurable correlations across targets. SPSD events violate these assumptions and their successful removal not only rectifies the flux values of affected targets, but demonstrably improves the overall performance of PDC de-trending.

Kolodziejczak, Jeffery↗

Mesospheric and Upper Stratospheric Temperatures From OMPS-LP

We report the development of a temperature profile data set from the Ozone Mapping and Profiler Suite Limb Profiler (OMPS-LP) instrument on the Suomi NPP satellite. The data set covers a roughly 10 year period from 2012 to 2022, and temperatures are provided in the altitude range between 35 and 70 km. The algorithm uses daytime Rayleigh scattered radiation near 350 nm to estimate atmospheric density profiles, which are vertically integrated using the hydrostatic equation to estimate atmospheric pressure. Temperature profiles are then derived using the ideal gas law. Spectral structures in the OMPS-LP radiances are a source of systematic errors that limit the absolute accuracy to ±2 K. However, since the systematic errors do not change significantly over time, the relative accuracy is better than ±1 K. Our temperature data set has been designed to supplement global temperature maps produced by assimilation of data from traditional meteorological sensors, including GNSS radio occultation sensors, that provide high quality atmospheric temperature profiles up to 40–55 km. We show comparisons to other co-located temperature datasets to validate our product.

Observations of Mesospheric and Upper Stratospheri↗

Deterministic Modeling of the High Temperature Test Reactor with DRAGON-HEXPEDITE

The Idaho National Laboratory (INL) is tasked with the development of reactor physics analysis capability of the Next Generation Nuclear Power (NGNP) project. In order to examine the INL’s current prismatic reactor analysis tools, the project is conducting a benchmark exercise based on modeling the High Temperature Test Reactor (HTTR). This exercise entails the development of a model for the initial criticality, a 19 fuel column thin annular core, and the fully loaded core critical condition with 30 fuel columns. Special emphasis is devoted to physical phenomena and artifacts in HTTR that are similar to phenomena and artifacts in the NGNP base design. The DRAGON code is used in this study since it offers significant ease and versatility in modeling prismatic designs. DRAGON can generate transport solutions via Collision Probability (CP), Method of Characteristics (MOC) and Discrete Ordinates (Sn). A fine group cross-section library based on the SHEM 281 energy structure is used in the DRAGON calculations. The results from this study show reasonable agreement in the calculation of the core multiplication factor with the MC methods, but a consistent bias of 2-3% with the experimental values is obtained. This systematic error has also been observed in other HTTR benchmark efforts and is well documented in the literature. The ENDF/B VII graphite and U 235 cross sections appear to be the main source of the error. The isothermal temperature coefficients calculated with the fully loaded core configuration agree well with other benchmark participants but are 40% higher than the experimental values. This discrepancy with the measurement partially stems from the fact that during the experiments the control rods were adjusted to maintain criticality, whereas in the model, the rod positions were fixed. In addition, this work includes a brief study of a cross section generation approach that seeks to decouple the domain in order to account for neighbor effects. This spectral interpenetration is a dominant effect in annular HTR physics. This analysis methodology should be further explored in order to reduce the error that is systematically propagated in the traditional generation of cross sections.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Track-Level-Compensation Look-Up Table Improves Antenna Pointing Precision

This article presents the improvement of the beam-waveguide antenna pointing accuracy due to the implementation of the track-level-compensation look-up table. It presents the development of the table, from the measurements of the inclinometer tilts to the processing of the measurement data and the determination of the threeaxis alidade rotations. The table consists of three axis rotations of the alidade as a function of the azimuth position. The article also presents the equations to determine the elevation and cross-elevation errors of the antenna as a function of the alidade rotations and the antenna azimuth and elevation positions. The table performance was verified using radio beam pointing data. The pointing error decreased from 4.5 mdeg to 1.4 mdeg in elevation and from 14.5 mdeg to 3.1 mdeg in cross-elevation. I. Introduction The Deep Space Station 25 (DSS 25) antenna shown in Fig. 1 is one of NASA s Deep Space Network beam-waveguide (BWG) antennas. At 34 GHz (Ka-band) operation, it is necessary to be able to track with a pointing accuracy of 2-mdeg root-mean-square (rms). Repeatable pointing errors of several millidegrees of magnitude have been observed during the BWG antenna calibration measurements. The systematic errors of order 4 and lower are eliminated using the antenna pointing model. However, repeatable pointing errors of higher order are out of reach of the model. The most prominent high-order systematic errors are the ones caused by the uneven azimuth track. The track is shown in Fig. 2. Manufacturing and installation tolerances, as well as gaps between the segments of the track, are the sources of the pointing errors that reach over 14-mdeg peak-to-peak magnitude, as reported in [1,2]. This article presents a continuation of the investigations and measurements of the pointing errors caused by the azimuth-track-level unevenness that were presented in [1] and [2], and it presents the implementation results. Track-level-compensation (TLC) look-up tables were created for the DSS 25, DSS 26, DSS 34, and DSS 55 antennas. To date, the most complete and detailed results were obtained for the DSS 25 and DSS 55 antennas. In this article, for brevity of presentation, we present the DSS 25 antenna results only. 1 Communications Ground Systems Section. The research described in this publication was carried out by the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration.

Gawronski, W.↗

Annealing a Follow-up Program: Improvement of the Dark Energy Figure of Merit for Optical Galaxy Cluster Surveys

The precision of cosmological parameters derived from galaxy cluster surveys is limited by uncertainty in relating observable signals to cluster mass. We demonstrate that a small mass-calibration follow-up program can significantly reduce this uncertainty and improve parameter constraints, particularly when the follow-up targets are judiciously chosen. To this end, we apply a simulated annealing algorithm to maximize the dark energy information at fixed observational cost, and find that optimal follow-up strategies can reduce the observational cost required to achieve a specified precision by up to an order of magnitude. Considering clusters selected from optical imaging in the Dark Energy Survey, we find that approximately 200 low-redshift X-ray clusters or massive Sunyaev-Zel'dovich clusters can improve the dark energy figure of merit by 50%, provided that the follow-up mass measurements involve no systematic error. In practice, the actual improvement depends on (1) the uncertainty in the systematic error in follow-up mass measurements, which needs to be controlled at the 5% level to avoid severe degradation of the results; and (2) the scatter in the optical richness-mass distribution, which needs to be made as tight as possible to improve the efficacy of follow-up observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-H-CAMPUS-TeP2-04: Measurement of Stereotactic Output Factors with DNA Double-Strand Breaks

Purpose: Radiotherapy treatment is specified by radiation dose prescriptions, but biological DNA damage actually controls treatment effectiveness. It is impractical to directly measure dose in the clinic, so we measure quantities, such as collected charge, and calculate the relationship to dose. At small fields, such as those in stereotactic radiosurgery (SRS), charged-particle equilibrium (CPE) breaks down and the accuracy of the measurement for delivered dose decreases. By measuring DNA double-strand breaks (DSB) directly, we believe treatment accuracy could improve by providing a more meaningful measurement. Methods: A DNA dosimeter, consisting of magnetic streptavidin beads attached to 4 kilobase pair DNA strands labeled with biotin and fluorescein amidite (FAM) on opposing ends, was suspended in phosphate-buffered saline (PBS). Twenty µL samples were placed in plastic micro-capillary tubes inside a water tank setup and irradiated with 10 cm, 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm radiation field sizes, where the three smallest sizes were cones. After irradiation, the dosimeters were mechanically separated into beads (intact DNA) and supernatant (broken DNA/FAM) using a magnet. The fluorescence was read and the probability of DSB was calculated. This was used to calculate the output factor for an SRS beam and compared to that measured using a diode detector. Results: The output factors relative to a 10 cm field were 0.89±0.07, 0.76±0.08, 0.59±0.04, and 0.78±0.12 for the field sizes of 3 cm, 1.25 cm, 0.75 cm, and 0.5 cm, respectively. Some of the diode measurements do not fall within these uncertainties. Conclusion: This was the first attempt to measure output factors in a water tank with the DNA dosimeter. Although differences compared to the diode were observed, the uncertainty analysis ignored systematic errors. For future work, we will repeat this experiment to quantify and correct systematic errors, such as those caused by positional alignment and sample contamination. This work was funded in part by CPRIT (RP140105).

60 APPLIED LIFE SCIENCES↗

Within-Tunnel Variations in Pressure Data for Three Transonic Wind Tunnels

This paper compares the results of pressure measurements made on the same test article with the same test matrix in three transonic wind tunnels. A comparison is presented of the unexplained variance associated with polar replicates acquired in each tunnel. The impact of a significance component of systematic (not random) unexplained variance is reviewed, and the results of analyses of variance are presented to assess the degree of significant systematic error in these representative wind tunnel tests. Total uncertainty estimates are reported for 140 samples of pressure data, quantifying the effects of within-polar random errors and between-polar systematic bias errors.

DeLoach, Richard↗

A Well-Calibrated Ocean Algorithm for Special Sensor Microwave/Imager

I describe an algorithm for retrieving geophysical parameters over the ocean from special sensor microwave/imager (SSM/I) observations. This algorithm is based on a model for the brightness temperature T(sub B) of the ocean and intervening atmosphere. The retrieved parameters are the near-surface wind speed W, the columnar water vapor V, the columnar cloud liquid water L, and the line-of-sight wind W(sub LS). I restrict my analysis to ocean scenes free of rain, and when the algorithm detects rain, the retrievals are discarded. The model and algorithm are precisely calibrated using a very large in situ database containing 37,650 SSM/I overpasses of buoys and 35,108 overpasses of radiosonde sites. A detailed error analysis indicates that the T(sub B) model rms accuracy is between 0.5 and 1 K and that the rms retrieval accuracies for wind, vapor, and cloud are 0.9 m/s, 1.2 mm, and 0.025 mm, respectively. The error in specifying the cloud temperature will introduce an additional 10% error in the cloud water retrieval. The spatial resolution for these accuracies is 50 km. The systematic errors in the retrievals are smaller than the rms errors, being about 0.3 m/s, 0.6 mm, and 0.005 mm for W, V, and L, respectively. The one exception is the systematic error in wind speed of -1.0 m/s that occurs for observations within +/-20 deg of upwind. The inclusion of the line-of-sight wind W(sub LS) in the retrieval significantly reduces the error in wind speed due to wind direction variations. The wind error for upwind observations is reduced from -3.0 to -1.0 m/s. Finally, I find a small signal in the 19-GHz, horizontal polarization (h(sub pol) T(sub B) residual DeltaT(sub BH) that is related to the effective air pressure of the water vapor profile. This information may be of some use in specifying the vertical distribution of water vapor.

Wentz, Frank J.↗