Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopic techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

The millimeter and submillimeter spectrum of CF(+)

The application of a recently described technique for producing significantly enhanced concentrations of molecular ions for spectroscopic study to the detection and measurement of the millimeter and submillimeter wave spectrum of CF(+) is reported. The experimental procedure is discussed, and the measured absorption frequencies are shown and compared with those calculated from spectral constants. These constants are given together with those from the infrared spectrum by Kawaguchi and Hirota (1985).

Plummer, G. M.↗

Analysis of a new class of grazing incidence spectroscopic telescope

The throughput and imaging properties of one of a new class of grazing incidence spectroscopic telescope are examined with a Monte Carlo ray tracing technique. The results are compared with Wolter Schwarzschild type II telescopes of similar size. The image quality of this telescope is comparable, and the control of the off-axis light is superior to the Wolter Schwarzschild design.

Green, J. C.↗

Laboratory diode laser spectroscopy in molecular planetary astronomy

Infrared spectroscopy of planetary atmospheres is performed at high spectral resolution comparable to that in the laboratory. This requires that laboratory spectroscopy use the highest resolution and the most accurate techniques. Tunable diode laser spectroscopy can supply many of the spectroscopic parameters needed by astronomers. In particular, line positions, line strengths, and collisional line widths are measured with diode lasers, and these are often among the best values available. Diode laser spectra are complimentary to lower resolution, broader-coverage Fourier transform spectra. Certain procedures must be adopted, however, when using diode lasers, for determining their output characteristics and for calibrating each spectrum against quality references.

Jennings, D. E.↗

High angular resolution measurements of Algol

Algol (Beta Per) is an extensively studied triple system which includes an eclipsing pair. Using long baseline optical interferometry, the AB-C system of Algol has had its geometric and physical parameters determined with higher resolution and accuracy than obtained with other techniques. The orbital elements are determined, without the use of spectroscopic data, as follows: P = 680.05 d +/- 0.06 d, T = JD 2,446,931.4 +/- 1.5, e = 0.225 +/- 0.005, a-double-prime = 94.61 +/- 0.22 mas, i = 83.98 deg +/- 0.09 deg, omega = 310.29 deg +/- 0.08 deg, and Omega = 312.26 deg +/- 0.13 deg. The distance to Algol is determined as 28.2 +/- 0.8 pc. The absolute magnitude of the C component is 2.86 +/- 0.46 mag, and its mass is 1.50 +/- 0.11 solar mass. The observational results indicate the difference of the inclinations between the eclipsing pair and the wide pair to be within 1.6 deg. For the first time, the eclipsing of the close pair was observed interferometrically, and the results compare well with those from photometry.

Pan, Xiaopei↗

Tentative Identification of the 780/cm nu(sub 4) Band Q Branch of Chlorine Nitrate in High-Resolution Solar Absorption Spectra of the Stratosphere

Absorption by the Q branch of the nu(sub 4), band of ClONO2 at 780.2/cm has been tentatively identified in a series of 0.02/cm resolution balloon-borne solar absorption spectra of the stratosphere. The spectral data were recorded at sunset from a flot altitude of 33.5 km during a balloon flight from Holloman Air Force Base (32.8deg N, 106.0 deg W) near Alamogordo, New Mexico, on March 23 1998. A preliminary ClONO2 vertical profile has been determined from the stratospheric spectra by using the technique of nonlinear least squares spectral curve fitting and new spectroscopic parameters deduced from high-resolution laboratory spectra of ClONO2 and O3.

Rinsland, C. P.↗

Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration

The most accurate astronomical data is available from space-based observations that are not impeded by the Earth's atmosphere. Such measurements may require spectral samples taken as long as decades apart, with the 1 cm/s velocity precision integrated over a broad wavelength range. This raises the requirements specifically for instruments used in astrophysics research missions -- their stringent wavelength resolution and accuracy must be maintained over years and possibly decades. Therefore, a stable and broadband optical calibration technique compatible with spaceflights becomes essential. The space-based spectroscopic instruments need to be calibrated in situ, which puts forth specific requirements to the calibration sources, mainly concerned with their mass, power consumption, and reliability. A high-precision, high-resolution reference wavelength comb source for astronomical and astrophysics spectroscopic observations has been developed that is deployable in space. The optical comb will be used for wavelength calibrations of spectrographs and will enable Doppler measurements to better than 10 cm/s precision, one hundred times better than the current state-of-the- art.

Strekalov, Dmitry V.↗

A Miniaturized Laser Heterodyne Radiometer for a Global Ground-Based Column Carbon Monitoring Network

We present progress in the development of a passive, miniaturized Laser Heterodyne Radiometer (mini-LHR) that will measure key greenhouse gases (C02, CH4, CO) in the atmospheric column as well as their respective altitude profiles, and O2 for a measure of atmospheric pressure. Laser heterodyne radiometry is a spectroscopic method that borrows from radio receiver technology. In this technique, a weak incoming signal containing information of interest is mixed with a stronger signal (local oscillator) at a nearby frequency. In this case, the weak signal is sunlight that has undergone absorption by a trace gas of interest and the local oscillator is a distributive feedback (DFB) laser that is tuned to a wavelength near the absorption feature of the trace gas. Mixing the sunlight with the laser light, in a fast photoreceiver, results in a beat signal in the RF. The amplitude of the beat signal tracks the concentration of the trace gas in the atmospheric column. The mini-LHR operates in tandem with AERONET, a global network of more than 450 aerosol sensing instruments. This partnership simplifies the instrument design and provides an established global network into which the mini-LHR can rapidly expand. This network offers coverage in key arctic regions (not covered by OCO-2) where accelerated warming due to the release of CO2 and CH4 from thawing tundra and permafrost is a concern as well as an uninterrupted data record that will both bridge gaps in data sets and offer validation for key flight missions such as OCO-2, OCO-3, and ASCENDS. Currently, the only ground global network that routinely measures multiple greenhouse gases in the atmospheric column is TCCON (Total Column Carbon Observing Network) with 18 operational sites worldwide and two in the US. Cost and size of TCCON installations will limit the potential for expansion, We offer a low-cost $30Klunit) solution to supplement these measurements with the added benefit of an established aerosol optical depth measurement. Aerosols induce a radiative effect that is an important modulator of regional carbon cycles. Changes in the diffuse radiative flux fraction (DRF) due to aerosol loading have the potential to alter the terrestrial carbon exchange.

Wilson, Emily L.↗

Stellar Echo Imaging of Exoplanets

All stars exhibit intensity fluctuations over several timescales, from nanoseconds to years. These intensity fluctuations echo off bodies and structures in the star system. We posit that it is possible to take advantage of these echoes to detect, and possibly image, Earth-scale exoplanets. Unlike direct imaging techniques, temporal measurements do not require fringe tracking, maintaining an optically-perfect baseline, or utilizing ultra-contrast coronagraphs. Unlike transit or radial velocity techniques, stellar echo detection is not constrained to any specific orbital inclination. Current results suggest that existing and emerging technology can already enable stellar echo techniques at flare stars, such as Proxima Centauri, including detection, spectroscopic interrogation, and possibly even continent-level imaging of exoplanets in a variety of orbits. Detection of Earth-like planets around Sun-like stars appears to be extremely challenging, but cannot be fully quantified without additional data on micro- and millisecond-scale intensity fluctuations of the Sun. We consider survey missions in the mold of Kepler and place preliminary constraints on the feasibility of producing 3D tomographic maps of other structures in star systems, such as accretion disks. In this report we discuss the theory, limitations, models, and future opportunities for stellar echo imaging.

stellar↗

Local Measurement of Tropospheric HO(x)

In March of 1992 a workshop sponsored by NASA and NSF was held at SRI International to assess the current ability to measure atmospheric OH and HO2. The measurement techniques reviewed during the workshop for detection of OH included five laser-induced fluorescence schemes, five laser-based adsorption techniques, and four non-laser methods. Six instruments or instrument concepts for HO2 detection, including chemical amplification, conversion to OH with subsequent OH detection, or direct spectroscopic detection of the HO2 were also discussed. The conclusions from the workshop identify several measurement techniques for OH and HO2 that are ready for field tests. These have the ability to measure the radicals with sufficient sensitivity and accuracy to form meaningful comparison with atmospheric model predictions. The workshop conclusions also include recommendations for informal and formal intercomparison protocols.

Crosley, David R.↗

Theoretical Study of the First Transition Row Oxides and Sulfides

The first transition row oxides and sulfides are studied using several different levels of theory. The calculations show the bonding mechanism in the sulfides and oxides to be very similar. For the oxides, accurate experimental data allow the theoretical methods to be calibrated. The same level of theory is used to study the sulfides where there is far less experimental information. For ScO through MnO and CuO the coupled cluster singles and doubles technique including a perturbational estimate of the unliked triple excitations [CCSD(T)] yields spectroscopic constants ((tau)e, (omega)e, and D0) in good agreement with experiment. The triple excitations are found to be very important in achieving this accuracy. For FeO to NiO, the single determinant self-consistent-field (SCF) approach yields pi orbitals that are localized on the metal or oxygen. This appears to cause problems for the single reference techniques; this is discussed in detail for NiO. The complete-active-space SCF/internally contracted averaged coupled pair functional approach (CASSCF/ICACPF) works well for FeO to NiO. The calculation of accurate dipole moments is found to be very difficult.

Bauschlicher, Charles W., Jt.↗

Tunable lasers and their application in analytical chemistry

The impact that laser techniques might have in chemical analysis is examined. Absorption, scattering, and heterodyne detection is considered. Particular emphasis is placed on the advantages of using frequency-tunable sources, and dye solution lasers are regarded as the outstanding example of this type of laser. Types of spectroscopy that can be carried out with lasers are discussed along with the ultimate sensitivity or minimum detectable concentration of molecules that can be achieved with each method. Analytical applications include laser microprobe analysis, remote sensing and instrumental methods such as laser-Raman spectroscopy, atomic absorption/fluorescence spectrometry, fluorescence assay techniques, optoacoustic spectroscopy, and polarization measurements. The application of lasers to spectroscopic methods of analysis would seem to be a rewarding field both for research in analytical chemistry and for investments in instrument manufacturing.

Steinfeld, J. I.↗

Space environmental effects on the integrity of chromic acid anodized coatings

The Long Duration Exposure Facility (LDEF) tray clamps used to hold the experiment trays in place on the LDEF were analyzed to determine the effects of long term space exposure on the performance of the chromic acid anodized coating. Spectroscopic anomalies observed appeared to be random and related to application techniques as opposed to exposure or position on LDEF. Thickness measurements indicated that the coating was less than 1u and was probably not degraded by space exposure. Metallurgical analysis revealed that leading edge exposure may have increased the porosity of the coating. Emittance values for the coating decreased uniformly by an average of 6.8 percent while solar absorptance values increased for trailing edge and decreased for leading edge specimens. The a/e ratio for the coating also increased as a result of long term space exposure.

Plagemann, Walter L.↗

Possible identification of a cluster of galaxies at redshift z = 3.4

We report the possible detection of a cluster of 16 radio-quiet galaxies at z = 3.4, identified in the field around the optically thick absorption system toward Q0000-263 at z(sub abs) = 3.390. Two of them, a Lyman alpha emitter at z = 3.428 and the galaxy responsible for the absorption system, have redshifts spectroscopically confirmed. The other 14 galaxies identified using a multicolor imaging technique designed to detect sources in the redshift interval 3 approximately less than z approximately less than 3.5 which are characterized by a Lyman discontinuity in an otherwise flat spectrum, have broad-band spectral energy distributions identical to the two galaxies with known redshift. They are spatially distributed in two apparent clumps, around the damped absorber and the Lyman alpha galaxy, respectively. A clustering analysis excludes with 98.8% confidence that this association is a realization of a Poissonian distribution and confirms that the observed clumps are real. The implications are that the 16 galaxies are members of a cluster at z approximately equals 3.4, by far the most distant ever detected. An estimate of the mass bounded in stars of this cluster is 3 x 10(exp 12) solar mass (q(sub 0) = 0 and H(sub 0) = 50 km/s/Mpc throughout this Letter), while the total mass (baryonic + dark) is 6 x 10(exp 14) solar mass. We also estimate that at z = 3.4 the correlation length is 2.2 Mpc, which, compared to the present value of 11 Mpc, suggests that the clustering evolution is still close to the linear regime.

Giavalisco, Mauro↗

Pigmenting agents in Martian soils: inferences from spectral, Mossbauer, and magnetic properties of nanophase and other iron oxides in Hawaiian palagonitic soil PN-9

We have examined a Hawaiian palagonitic tephra sample (PN-9) that has spectroscopic similarities to Martian bright regions using a number of analytical techniques, including Mossbauer and reflectance spectroscopy, X-ray diffraction, instrumental neutron activation analysis, electron probe microanalysis, transmission electron microscopy, and dithionite-citrate-bicarbonate extraction. Chemically, PN-9 has a Hawaiitic composition with alkali (and presumably silica) loss resulting from leaching by meteoric water during palagonitization; no Ce anomaly is present in the REE pattern. Mineralogically, our results show that nanophase ferric oxide (np-Ox) particles (either nanophase hematite (np-Hm) or a mixture of ferrihydrite and np-Hm) are responsible for the distinctive ferric doublet and visible-wavelength ferric absorption edge observed in Mossbauer and reflectivity spectra, respectively, for this and other spectrally similar palagonitic samples. The np-Ox particles appear to be imbedded in a hydrated aluminosilicate matrix material; no evidence was found for phyllosilicates. Other iron-bearing phases observed are titanomagnetite, which accounts for the magnetic nature of the sample; olivine; pyroxene; and glass. By analogy, np-Ox is likely the primary pigmenting agent of the bright soils and dust of Mars.

Minerals/analysis↗

GJ 229B: Solving the Puzzle of the First Known T Dwarf with the APOLLO Retrieval Code

GJ 229B was the first T dwarf to be discovered in 1995, and its spectrum has been more thoroughly observed than that of most other brown dwarfs. Yet a full spectroscopic analysis of its atmosphere has not been done with modern techniques. This spectrum has several peculiar features, and recent dynamical estimates of GJ 229B’s mass and orbit have disagreed widely, both of which warrant closer investigation. With a separation of tens of astronomical units from its host star, GJ 229B falls near the border of the planet and stellar population formation regimes, so its atmosphere could provide clues to formation processes for intermediate objects of this type. In an effort to resolve these questions, we performed retrievals on published spectra of GJ 229B over a wide range of wavelengths (0.5–5.1 μm) using the open-source APOLLO code. Based on these retrievals, we present a more precise mass estimate of 41.6 ± 3.3MJ and an effective temperature estimate of 869 +5 −7 K, which are more consistent with evolutionary models for brown dwarfs and suggest an older age for the system of >1.0 Gyr. We also present retrieved molecular abundances for the atmosphere, including replicating the previously observed high CO abundance, and discuss their implications for the formation and evolution of this object. This retrieval effort will give us insight into how to study other brown dwarfs and directly imaged planets, including those observed with JWST and other next-generation telescopes.

Alex R Howe↗

Development of a High-Pressure Gaseous Burner for Calibrating Optical Diagnostic Techniques

In this work-in-progress report, we show the development of a unique high-pressure burner facility (up to 60 atm) that provides steady, reproducible premixed flames with high precision, while having the capability to use multiple fuel/oxidizer combinations. The highpressure facility has four optical access ports for applying different laser diagnostic techniques and will provide a standard reference flame for the development of a spectroscopic database in high-pressure/temperature conditions. Spontaneous Raman scattering (SRS) was the first diagnostic applied, and was used to successfully probe premixed hydrogen-air flames generated in the facility using a novel multi-jet micro-premixed array burner element. The SRS spectral data include contributions from H2, N2, O2, and H2O and were collected over a wide range of equivalence ratios ranging from 0.16 to 4.9 at an initial pressure of 10-atm via a spatially resolved point SRS measurement with a high-performance optical system. Temperatures in fuel-lean to stoichiometric conditions were determined from the ratio of the Stokes to anti-Stokes scattering of the Q-branch of N2, and those in fuel-rich conditions via the rotational temperature of H2. The SRS derived temperatures using both techniques were consistent and indicated that the flame temperature was approximately 500 K below that predicted by adiabatic equilibrium, indicating a large amount of heat-loss at the measurement zone. The integrated vibrational SRS signals show that SRS provides quantitative number density data in high-pressure H2-air flames.

Kojima, Jun↗

Progress on a Rayleigh Scattering Mass Flux Measurement Technique

A Rayleigh scattering diagnostic has been developed to provide mass flux measurements in wind tunnel flows. Spectroscopic molecular Rayleigh scattering is an established flow diagnostic tool that has the ability to provide simultaneous density and velocity measurements in gaseous flows. Rayleigh scattered light from a focused 10 Watt continuous-wave laser beam is collected and fiber-optically transmitted to a solid Fabry-Perot etalon for spectral analysis. The circular interference pattern that contains the spectral information that is needed to determine the flow properties is imaged onto a CCD detector. Baseline measurements of density and velocity in the test section of the 15 cm x 15 cm Supersonic Wind Tunnel at NASA Glenn Research Center are presented as well as velocity measurements within a supersonic combustion ramjet engine isolator model installed in the tunnel test section.

Mielke-Fagan, Amy F.↗

Design and operation of the Pioneer Venus Orbiter ultraviolet spectrometer

The University of Colorado's ultraviolet spectrometer instrument carried on the Pioneer Venus Orbiter spacecraft is a 125-mm f/5 Ebert-Fastie design with a 250-mm Cassegrain telescope. The instrument has extensive logic to control the grating motor drive and to adapt the basic spectrometer to the constraints and opportunities of the mission. Success has been achieved in reconciling the conflicting requirements of spectroscopic, limb profile, and imaging observations. A description of the instrument operating techniques is given together with representative results of all three types.

Stewart, A. I. F.↗