Infrared spectroscopic analysis of the effects of simulated space radiation on a polyimide

Infrared spectroscopic techniques have been used to study the effects of electron radiation on the polyimide PMDA-p,p-prime- ODA. The radiation exposures were made at various dose rates, for a total dose approximately equal to that for 30 years of exposure to electron radiation in geosynchronous earth orbit. At high dose rates the major effect was probably the formation of a polyisoimide or a charged quaternary amine, and at the low dose rates the effect was a reduction in the amount or aromatic ether linkage. In addition, the effects of dose rate for a small total dose were studied. Elevated temperatures occurred at high dose rates and were, in part, probably the cause of the radiation product. The data suggest that dose rates for accelerated simulations of the space environment should not exceed 100,000 rads/sec.

Ferl, J. E.↗

High-resolution optical measurements of atmospheric winds from space. I - Lower atmosphere molecular absorption

A high-resolution spectroscopic technique, analogous to that used in the thermosphere to measure the vector wind fields in the upper troposphere and stratosphere, is described which uses narrow features in the spectrum of light scattered from the earth's lower atmosphere to provide Doppler information on atmospheric scattering and absorption. It is demonstrated that vector winds can be measured from a satellite throughout the lower atmosphere, using a multiple-etalon Fabry-Perot interferometer of modest aperture. It is found that molecular oxygen and water vapor absorption lines in the spectrum of sunlight scattered by the atmosphere are Doppler-shifted by the line of sight wind, so that they may be used to monitor the global wind systems in the upper troposphere and stratosphere.

Hays, P. B.↗

Stratospheric aerosols - Observation and theory

Important chemical and physical roles of aerosols are discussed, and properties of stratospheric aerosols as revealed by experimental data are described. In situ measurements obtained by mechanical collection and scattered-light detection yield the overall size distribution of the aerosols, and analyses of preserved aerosol precursor gases by wet chemical, cryogenic and spectroscopic techniques indicate the photochemical sources of particle mass. Aerosol chemical reactions including those of gaseous precursors, those in aqueous solution, and those on particle surfaces are discussed, in addition to aerosol microphysical processes such as nucleation, condensation/evaporation, coagulation and sedimentation. Models of aerosols incorporating such chemical and physical processes are presented, and simulations are shown to agree with measurements. Estimates are presented for the potential aerosol changes due to emission of particles and gases by aerospace operations and industrial consumption of fossil fuels, and it is demonstrated that although the climatic effects of existing levels of stratospheric aerosol pollution are negligible, potential increases in those levels might pose a future threat.

Turco, R. P.↗

Pulsed laser photolysis study of the reaction between O(3P) and HO2

It is pointed out that bimolecular reactions involving two free radicals are of great interest because both reactants have unpaired electrons and hence could interact at distances longer than those typical of radical-molecule encounters. A method based on laser photolysis is being developed to produce selectively free radicals in the homogeneous gas phase. This is to be done in such a way as to isolate the reaction of interest and subsequently follow the course of the reaction using spectroscopic techniques. The present investigation is concerned with a study in which the rate coefficient for the reaction of O(3P) with HO2, has been measured at N2 pressures ranging from 10 to 500 torr, taking into account the reaction O(3P)+HO2 yields OH-O2. In the described study, O(3P) and HO2 were produced by cophotolysis of O3 and H2O2 in N2 at 248.5 nm using a KrF excimer laser.

Ravishankara, A. R.↗

Flow velocity measurements with stimulated Rayleigh-Brillouin-gain spectroscopy

Using stimulated Rayleigh-Brillouin-gain spectroscopy, velocity measurements in an atmospheric-pressure subsonic nitrogen flow with 10 percent uncertainty have been conducted. It is shown that the accuracy of the velocity measurements increases with gas pressure, making this spectroscopic technique ideal for measuring velocity and other parameters of high-pressure (greater than 1-atm) atomic or molecular flows.

Herring, G. C.↗

Electron temperature and average density in spherical laser-produced plasmas - Ultraviolet plasma spectroscopy

The average values of the electron temperature Te and the electron density Ne in the corona plasmas of spherically irradiated high-Z targets have been estimated. Targets composed of the elements Cu through Br, Rb, and Mo were irradiated using the fundamental (1.06 microns) and the frequency-tripled (351 nm) output of the Omega laser system. Spectra were recorded in the wavelength region 15-200 A. Using various extreme ultraviolet spectroscopic techniques, it is found that for the case of a Mo plasma produced by frequency-tripled laser irradiation, Te = 2600 + or - 600 eV and Ne is greater than 6 x 10 to the 20th/cu cm. This is consistent with a 'flux limit' smaller than 0.1. The estimated values of Te and Ne are lower in the corona plasmas produced using the fundamental (1.06 micron) irradiation.

Goldsmith, S.↗

Mass loss from red giants - Results from ultraviolet spectroscopy

New instrumentation in space, primarily the IUE spacecraft, has enabled the application of ultraviolet spectroscopic techniques to the determination of physical properties and reliable mass loss rates for red giant winds. One important result is the determination of where in the H-R diagram are found stars with hot outer atmospheres and with cool winds. So far it appears that single cool stars, except perhaps the so-called hybrid stars, have either hot outer atmospheres or cool winds but not both. The C II resonance (1335 A) and intersystem (2325 A) multiplets have been used to derive temperatures, densities, and geometrical extents for the chromospheric portions of red giant winds, with the result that the red giants and the earlier giants with hot coronae have qualitatively different chromospheres. Mass loss rates can now be derived accurately from the analysis of asymmetric emission lines, such as the Mg II resonance lines, and from P Cygni profile lines of atoms in the dominant ionization stage when a hot star is available to probe the wind of a red giant. The Zeta Aur systems, consisting of a K-M supergiant and a main sequence B star are important systems for reliable mass loss rates for the red supergiant components are becoming available.

Linsky, J. L.↗

High-pressure ruby and diamond fluorescence - Observations at 0.21 to 0.55 terapascal

A diamond-anvil, high-pressure apparatus was used to extend the upper pressure limit of static laboratory experiments. Shifts of the R1 strong fluorescent line of ruby were observed that correspond to static pressures of 0.21 to 0.55 terapascal (2.1 to 5.5 megabars) at 25 C. Sensitive spectroscopic techniques in the pressure range 0.15 to 0.28 terapascal were used to observe ruby and diamond fluorescence separately; these two fluorescent emissions overlap strongly at high pressures. At pressures greater than approximately 0.28 terapascal, the diamond fluorescence diminished and the ruby fluorescence reappeared strongly. Pressure was determined by extrapolation of the calibrated shift of the ruby R1 line.

Xu, J. A.↗

Some recent infrared spectroscopy of interstellar processes

The potential which infrared spectroscopic techniques provide for studying interstellar process is demonstrated. Several examples are given. The data were obtained at UKIRT, using its frequency-chopped Fabry-Perot spectrometer and its seven-channel cooled grating spectrometer.

Geballe, T. R.↗

Investigation of PTFE transfer films by infrared emission spectroscopy and phase-locked ellipsometry

When a PTFE sheet was rubbed unidirectionally over a smooth surface of stainless steel an essentially monomolecular transfer film was formed. By ellipsometric and emission infrared spectroscopic techniques it was shown that the film was 10 to 15 A thick and birefringent. From the intensity differences of infrared bands obtained with a polarizer passing radiation polarized in mutually perpendicular planes, it was possible to deduce transfer film orientation with the direction of rubbing. After standing in air for several weeks the transfer films apparently increased in thickness by as much as threefold. At the same time both the index of refraction and the absorption index decreased. Examination of the surfaces by optical and electron microscopies showed that the films had become porous and flaky. These observations were consistent with previous tribological measurements. The coefficients of friction decreased with the formation of the transfer film but increased again as the film developed breaks. The applicability of the ellipsometric and polarized infrared emission techniques to the identification of monomolecular tribological transfer films of polymers such as PTFE has been demonstrated.

Lauer, James L.↗

Structural studies of gels and gel-glasses in the SiO2-GeO2 system using vibrational spectroscopy

GeO2 gel and gels in the SiO2-GeO2 system synthesized by the hydrolytic polycondensation of metal alkoxides have been studied by infrared and Raman spectroscopic techniques. The molecular structures, hydroxyl contents, and crystallinity of gels and gel-glasses in relation to the thermal history and GeO2 concentration were investigated. The binary compositions having up to 70 mol percent GeO2 were examined.

Mukherjee, Shyama P.↗

Determination of electron density and temperature in non-LTE plasmas from spectral lines of impurity ions

A novel approach for calculating the populations of the excited Li-like ions C IV, N V, O VI, and Ne VIII is presented. The populations of the 2(2P), 3(2S), 3(2P), and 3(2D) electronic levels in these ions in optically thin plasmas with a broad range of electron density, N(e), and temperature, T(e), are determined from the collisional-radiative model by solving the system of rate equations for the production of excited ions; the equations are linear with respect to the excited ion populations, and the N(e) and T(e) are taken as independent variables. These populations are used to determine the ratios of line intensities for dipole allowed transitions between various energy levels. This approach can be applied to impurities other than the lithiumlike ions and is especially useful for diagnostics of systems where nonintrusive spectroscopic techniques must be used.

Kunc, Joseph A.↗

Investigation of PTFE transfer films by infrared emission spectroscopy and phase-locked ellipsometry

When a PTFE sheet was rubbed unidirectionally over a smooth surface of stainless steel an essentially monomolecular transfer film was formed. by ellipsometric and emission infrared spectroscopic techniques it was shown that the film was 10 to 15 A thick and birefringent. From the intensity differences of infrared bands obtained with a polarizer passing radiation polarized in mutually perpendicular planes, it was possible to deduce transfer film orientation with the direction of rubbing. After standing in air for several weeks the transfer films apparently increased in thickness by as much as threefold. At the same time both the index of refraction and the absorption index decreased. Examination of the surfaces by optical and electron microscopies showed that the films had become porous and flaky. These observations were consistent with previous tribological measurements. The coefficients of friction decreased with the formation of the transfer film but increased again as the film developed breaks. The applicability of the ellipsometric and polarized infrared emission techniques to the identification of monomolecular tribological transfer films of polymers such as PTFE has been demonstrated.

Lauer, James L.↗

CCD camera system for cometary research

The objective is to upgrade the NASA/GSFC 36 inch telescope instrumentation, primarily with a new charge coupled device (CCD) camera system, to permit an effective monitoring program of cometary activity by means of narrowband imaging and spectroscopic techniques. Researchers have twice taken delivery of the CCD camera system from Princeton Scientific Instruments and twice returned it within six weeks for repair. During the times they had the camera system in the lab, they measured the instrumental performance of the TEK 512 x 512 CCD chip (e.g., readout noise, dark current, etc) and developed the complete operational software for the camera system plus several useful observing and data reduction routines for use at the telescope. The CCD camera system is controlled by an IBM-AT computer. The peripheral equipment and software to permit the efficient transfer of large amounts of data to the LASP's computers (VAXs) and subsequent timely reductions are also in place. The Io torus (S II) emission was monitored with a Fabry-Perot scanning spectrometer, in conjunction with the International Jupiter Watch. The CCD camera system will be coupled to a narrowband interference filter imager and a long-slit spectrograph to provide regular and well-calibrated spatial and spectral observations of comets.

Oliversen, R. J.↗

New transformations between crystalline and amorphous ice

High-pressure optical and spectroscopic techniques were used to obtain directly the ice I(h) - hda-ice transformation in a diamond-anvil cell, and the stability of the amorphous form is examined as functions of pressure and temperature. It is demonstrated that hda-ice transforms abruptly at 4 GPa and 77 K to a crystalline phase close in structure to orientationally disordered ice-VII and to a more highly ordered, ice-VIII-like structure at higher temperatures. This is the first time that an amorphous solid is observed to convert to a crystalline solid at low temperatures by compression alone. Phase transitions of this type may be relevant on icy planetary satellites, and there may also be implications for the high-pressure behavior of silica.

Hemley, R. J.↗

The origin, composition and history of cometary ices from spectroscopic studies

The spectroscopic analysis of pristine cometary material provides a very important probe of the chemical identity of the material as well as of the physical and chemical conditions which prevailed during the comet's history. Concerning classical spectroscopy, the spectral regions which will most likely prove most useful are the infrared, the visible and ultraviolet. Newer spectroscopic techniques which have the potential to provide equally important information include nuclear magnetic resonance (NMR) and electron spin resonance (ESR). Each technique is summarized with emphasis placed on the kind of information which can be obtained.

Allamandola, L. J.↗

Laser Spectroscopic Measurement Of Temperature And Density

Report discusses research on use of laser-induced fluorescence in oxygen and Raman scattering in air for simultaneous measurement of temperature and density of air. Major application of laser spectroscopic techniques, measurement of fluctuations of temperature and density in hypersonic flows in wind tunnels.

Mckenzie, Robert L.↗

Ultrafast IR detector response in high Tc superconducting thin films

The response from a high Tc superconducting multielement optical detector made of a laser deposited Y-Ba-Cu-O thin film has been evaluated. Several microscopic and spectroscopic techniques were used to establish the presence of the correct phase of the thin film. Optical pulses from a laser diode at 830 nm and from a Q-switched CO2-laser at 10.6 microns were used. The detector responded to 50 ps (FWHM) pulses. A comparison between dR/dT of the film and the response amplitude as a function of temperature indicated a bolometric response.

Lindgren, Mikael↗