Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software specification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Wcomp (Wind Farm Wake Comparison Framework) [SWR-23-72]

The Wind Farm Wake Comparison Framework (Wcomp) is a software tool to facilitate the comparison of a specific collection of wind farm wake modeling tools: Python-based, steady-state, analytical wake modeling utilities. Wcomp integrates another software project, windIO, to create a consistent method for describing a wind farm flow control problem. Additionally, a data structure is included to represent the outputs a wind farm flow control simulation. Well-described interfaces allow existing wake modeling tools to plug into this framework.

Mudafort, Rafael↗

Preliminary Radioisotope Screening for Off-site Consequence Assessment of Advanced Non-LWR Systems

Currently a set of 71 radionuclides are accounted for in off-site consequence analysis for LWRs. Radionuclides of dose consequence are expected to change for non-LWRs, with radionuclides of interest being type-specific. This document identifies an expanded set of radionuclides that may need to be accounted for in multiple non-LWR systems: high temperature gas reactors (HTGRs); fluoride-salt-cooled high-temperature reactors (FHRs); thermal-spectrum fluoride-based molten salt reactors (MSRs); fast-spectrum chloride-based MSRs; and, liquid metal fast reactors with metallic fuel (LMRs) Specific considerations are provided for each reactor type in Chapter 2 through Chapter 5, and a summary of all recommendations is provided in Chapter 6. All identified radionuclides are already incorporated within the MACCS software, yet the development of tritium-specific and carbon-specific chemistry models are recommended.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Argonne Reactor Code Software Verification and Validation Plan for the Versatile Test Reactor

This Argonne Reactor Code (ARC) software has taken a pivotal role in the design work of the Versatile Test Reactor. The ARC software itself consists of several independent or semiindependent pieces of software that are used in concert to carry out specific analysis and design objectives. In this report, we discuss the validation that is needed for the ARC software overall and discuss available, usable experimental data and how it relates to the VTR project. We also discuss the verification that is required for the ARC software with respect to its usage in the VTR project and give some concrete examples as to what it must accomplish. A list of goals for the verification and validation work are presented as the general procedure that will be implemented for every individual piece of software in ARC. The ARC software has been continuously developed for over 50 years and many of the features used for the VTR project have thus been rigorously tested for accuracy during that timeframe. The ARC software is presently under source code control and undergoes nightly regression testing of not only the individual pieces, but the interconnected aspects that are common to most analysis projects. Its greatest weakness, from a software verification and validation perspective, is both a lack of documentation and outdated documentation. As an example, much of the previous validation work will require contemporary effort to re-evaluate given the updated base data libraries and modifications to the software that have occurred since. This requires new documentation to be produced to support the usage of the software in the VTR project. The bulk of the ARC software is focused on steady state neutronics and TH behavior of a reactor system. In this regard, we have identified the ZPPR, FFTF, and EBR-II programs as the best candidates for sources of validation data for the VTR project. The ZPPR-15 series in the ZPPR program was chosen as it is the best representation of the VTR fuel form and reactor core layout of all of the ZPPR measurements. Additional support for it comes from the fact that most of the data has already been processed into usable ARC models for VTR validation. The FFTF and EBR-II reactors were both functional reactors that provide reactor scale measurements. FFTF is clearly a closer match to VTR and its startup measurements would be a very valuable validation basis. EBR-II has invaluable burnup related measurements that will play a key role in the ARC software validation work. Each piece of ARC software will require a report detailing the software verification. The validation work will be logically split into the results of modeling each identified experimental resource (ZPPR, EBR-II, FFTF). The intended timeline for the VTR project is to have the ARC software verified and validated by the end of fiscal year 2020. This is incumbent on sufficient funding allocated to V&V activities and no change in programmatic priorities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Statistical Mechanics on Lattices (smol) v0.0.1

smol is a Python implementation of the Cluster Expansion Method and extensions of this methodology; which is used to fit applied lattice models from first principle calculations for subsequent use in Monte Carlo simulations for computing thermodynamic and statistical properties of atomic configuration. smol has a several notable advantages over other similar software packages. The first being its Python implementation which makes it easy to use even for users with little software and coding skills. Despite being implemented in Python, essential Monte Carlo routines are implemented in Cython such that performance is not compromised and is competitive even to similar software implemented in C/C++. Furthermore, the package has specific functionality for handling complex ionic materials (such as cathodes and electrolytes) that is not readily available in other packages. Lastly, the software has a flexible and modular design with the intention of making it fast and efficient to develop and extend the methodology.

Barroso-Luque, Luis↗

PeakWorks

The PeakWorks software is designed to assist in the quantitative analysis of atom probe tomography (APT) generated mass spectra. Specifically, through an interactive user interface, mass peaks can be identified automatically (defined by a threshold) and/or identified manually. The software then provides a means to assign specific elemental isotopes (including more than one) to each peak. The software also provides a means for the user to choose background subtraction of each peak based on background fitting functions, the choice of which is left to the users discretion. Peak ranging (the mass range over which peaks are integrated) is also automated allowing the user to chose a quantitative range (e.g. full-widthhalf- maximum). The software then integrates all identified peaks, providing a background-subtracted composition, which also includes the deconvolution of peaks (i.e. those peaks that happen to have overlapping isotopic masses). The software is also able to output a 'range file' that can be used in other software packages, such as within IVAS. A range file lists the peak identities, the mass range of each identified peak, and a color code for the peak. The software is also able to generate 'dummy' peak ranges within an outputted range file that can be used within IVAS to provide a means for background subtracted proximity histogram analysis.

Source record↗

Genome-Scale 13 C Fluxomics Modeling for Metabolic Engineering of Saccharomyces cerevisiae .

Synthetic biology is a rapidly developing field that pursues the application of engineering principles and development approaches to biological engineering. Synthetic biology is poised to change the way biology is practiced, and has important practical applications: for example, building genetically engineered organisms to produce biofuels, medicines, and other chemicals. Traditionally, synthetic biology has focused on manipulating a few genes (e.g., in a single pathway or genetic circuit), but its combination with systems biology holds the promise of creating new cellular architectures and constructing complex biological systems from the ground up. Enabling this merge of synthetic and systems biology will require greater predictive capability for modeling the behavior of cellular systems, and more comprehensive data sets for building and calibrating these models. The so-called "-omics" data sets can now be generated via high throughput techniques in the form of genomic, proteomic, transcriptomic, and metabolomic information on the engineered biological system. Of particular interest with respect to the engineering of microbes capable of producing biofuels and other chemicals economically and at scale are metabolomic datasets, and their insights into intracellular metabolic fluxes. Metabolic fluxes provide a rapid and easy to understand picture of how carbon and energy flow throughout the cell. Furthermore, we present a detailed guide to performing metabolic flux analysis and modeling using the open source JBEI Quantitative Metabolic Modeling (jQMM) library. This library allows the user to transform metabolomics data in the form of isotope labeling data from a 13 C labeling experiment into a determination of cellular fluxes that can be used to develop genetic engineering strategies for metabolic engineering.The jQMM library presents a complete toolbox for performing a range of different tasks of interest in metabolic engineering. Various different types of flux analysis and modeling can be performed such as flux balance analysis, 13 C metabolic flux analysis, and two-scale 13 C metabolic flux analysis (2S- 13 C MFA). 2S- 13 C MFA is a novel method that determines genome-scale fluxes without the need of every single carbon transition in the metabolic network. In addition to several other capabilities, the jQMM library can make model based predictions for how various genetic engineering strategies can be incorporated toward bioengineering goals: it can predict the effects of reaction knockouts on metabolism using both the MoMA and ROOM methodologies. In this chapter, we will illustrate the use of the jQMM library through a step-by-step demonstration of flux determination and knockout prediction in a complex eukaryotic model organism: Saccharomyces cerevisiae ( S. cerevisiae ). Included with this chapter is a digital Jupyter Notebook file that provides a computable appendix showing a self-contained example of jQMM usage, which can be changed to fit the user's specific needs. As an open source software project, users can modify and extend the code base to make improvements at will, allowing them to share their development work and contribute back to the jQMM modeling community.

-Omics data↗

Sphere-Enhanced Microwave Ablation (sMWA) Versus Bland Microwave Ablation (bMWA): Technical Parameters, Specific CT 3D Rendering and Histopathology

PurposeThis study was designed to compare technical parameters during ablation as well as CT 3D rendering and histopathology of the ablation zone between sphere-enhanced microwave ablation (sMWA) and bland microwave ablation (bMWA).MethodsIn six sheep-livers, 18 microwave ablations were performed with identical system presets (power output: 80 W, ablation time: 120 s). In three sheep, transarterial embolisation (TAE) was performed immediately before microwave ablation using spheres (diameter: 40 ± 10 μm) (sMWA). In the other three sheep, microwave ablation was performed without spheres embolisation (bMWA). Contrast-enhanced CT, sacrifice, and liver harvest followed immediately after microwave ablation. Study goals included technical parameters during ablation (resulting power output, ablation time), geometry of the ablation zone applying specific CT 3D rendering with a software prototype (short axis of the ablation zone, volume of the largest aligned ablation sphere within the ablation zone), and histopathology (hematoxylin-eosin, Masson Goldner and TUNEL).ResultsResulting power output/ablation times were 78.7 ± 1.0 W/120 ± 0.0 s for bMWA and 78.4 ± 1.0 W/120 ± 0.0 s for sMWA (n.s., respectively). Short axis/volume were 23.7 ± 3.7 mm/7.0 ± 2.4 cm{sup 3} for bMWA and 29.1 ± 3.4 mm/11.5 ± 3.9 cm{sup 3} for sMWA (P < 0.01, respectively). Histopathology confirmed the signs of coagulation necrosis as well as early and irreversible cell death for bMWA and sMWA. For sMWA, spheres were detected within, at the rim, and outside of the ablation zone without conspicuous features.ConclusionsSpecific CT 3D rendering identifies a larger ablation zone for sMWA compared with bMWA. The histopathological signs and the detectable amount of cell death are comparable for both groups. When comparing sMWA with bMWA, TAE has no effect on the technical parameters during ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of topology optimized Ti-6Al-4V components using electron beam powder bed fusion

The use of manufacturing to generate topology optimized components shows promise for designers. However, designers who assume that additive manufacturing follows traditional manufacturing techniques may be misled due to the nuances in specific techniques. Since commercial topology optimization software tools are neither designed to consider orientation of the parts nor large variations in properties, the goal of this research is to evaluate the limitations of an existing commercial topology optimization software (i.e. Inspire®) using electron beam powder bed fusion (i.e. Arcam®) to produce optimized Ti-6Al-4V alloy components. Emerging qualification tools from Oak Ridge National Laboratory including in-situ near-infrared imaging and log file data analysis were used to rationalize the final performance of components. While the weight savings of each optimized part exceeded the initial criteria, the failure loads and locations proved instrumental in providing insight to additive manufacturing with topology optimization. In conclusion, this research has shown the need for a comprehensive understanding of correlations between geometry, additive manufacturing processing conditions, defect generation, and microstructure for characterization of complex components such as those designed by topology optimization.

42 ENGINEERING↗

From data to knowledge: The future of multi-omics data analysis for the rhizosphere

The rhizosphere is the interface between the root system of a plant and its surrounding soil. The microbiome of the rhizosphere, which is the totality of all microbes present there, represents a complex microbial ecosystem that nourishes the terrestrial biosphere. In order to untangle the complexity of the rhizosphere, and of the rhizospheric microbiome in particular, an integrated multi-omics approach can be applied to reveal the composition of the rhizospheric microbiome (through 16S ribosomal amplicons and metagenomics), the functional properties of the microbiome (through metatranscriptomics and metaproteomics), and the signaling network within the rhizosphere (through metametabolomics). The successful application of integrated multi-omics to rhizospheric science depends on the availability of rhizosphere-specific data and on the appropriate software used to analyze omics data from the rhizosphere. Here, we analyze the availability of software suites that are normally applied to surrogate disciplines (e.g., soil and plants) but which can be used for rhizospheric science. We also identify potential issues, challenges, and opportunities for rhizosphere science.

54 ENVIRONMENTAL SCIENCES↗

Assessing XMT-Measurement Variability of Air-Water Interfacial Areas in Natural Porous Media

This study investigates the accuracy and reproducibility of air-water interfacial areas measured with high-resolution synchrotron X-ray microtomography (XMT). Columns packed with one of two relatively coarse-grained monodisperse granular media, glass beads or a well-sorted quartz sand, were imaged over several years, encompassing changes in acquisition equipment, improved image quality, and enhancements to image acquisition and to processing software. For the glass beads, the specific solid surface area (SSSA-XMT) of 31.6 ± 1 cm -1 determined from direct analysis of the segmented solid-phase image data is statistically identical to the independently calculated geometric smooth-sphere specific solid surface area (GSSA, 32 ± 1 cm -1 ) and to the measured SSSA (28 ± 3 cm -1 ) obtained with the N2-Brunauer, Emmett, and Teller method. The maximum specific air-water interfacial area (Amax) is 27.4 (±2) cm -1 , which compares very well to the SSSA-XMT, GSSA, and SSSA-N2-Brunauer, Emmett, and Teller values. For the sand, the SSSA-XMT (111 ± 2 cm -1 ) and GSSA (113 ± 1 cm -1 ) are similar. The mean Amax is 96 ± 5 cm -1 , which compares well to both the SSSA and the GSSA values. The XMT-SSSA values deviated from the GSSA values by 7–16% for the first four experiments but were essentially identical for the later experiments. This indicates that enhancements in image acquisition and processing improved data accuracy. The Amax values ranged from 74 cm -1 to 101 cm -1 , with a coefficient of variation (COV) of 9%. The maximum capillary interfacial area ranged from 12 cm-1 to 19 cm -1 , for a COV of 10%. The COVs for both decreased to 5–6% for the latter five experiments. These results demonstrate that XMT imaging provides accurate and reproducible measurements of total and capillary interfacial areas.

54 ENVIRONMENTAL SCIENCES↗

The case for data science in experimental chemistry: examples and recommendations

The physical sciences community is increasingly taking advantage of the possibilities offered by modern data science to solve problems in experimental chemistry and potentially to change the way we design, conduct and understand results from experiments. Successfully exploiting these opportunities involves considerable challenges. In this Expert Recommendation, we focus on experimental co-design and its importance to experimental chemistry. We provide examples of how data science is changing the way we conduct experiments, and we outline opportunities for further integration of data science and experimental chemistry to advance these fields. Our recommendations include establishing stronger links between chemists and data scientists; developing chemistry-specific data science methods; integrating algorithms, software and hardware to ‘co-design’ chemistry experiments from inception; and combining diverse and disparate data sources into a data network for chemistry research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

XRootD Third Party Copy for the WLCG and HLLHC

A Third Party Copy (TPC) mechanism has existed in the pure XRootD storage environment for many years. However, using the XRootD TPC in the WLCG environment presents additional challenges due to the diversity of the storage systems involved such as EOS, dCache, DPM and ECHO, requiring that we carefully navigate the unique constraints imposed by these storage systems and their site-specific environments through customized configuration and software development. To support multitenant setups seen at many WLCG sites, X509 based authentication and authorization in XRootD was significantly improved to meet both security and functionality requirements. This paper presents architecture of the pull based TPC with optional X509 credential delegation, and how it is implemented in native XRootD and dCache. The paper discusses technical requirements, challenges, design choices and implementation details in the WLCG storage systems, as well as in FTS/gfal2. It also outlines XRootD’s plan to support newer TPC and security models such as token based authorization.

Adye, T.↗

Nitrogen expander cycles for large capacity liquefaction of natural gas

Thermodynamic study is performed on nitrogen expander cycles for large capacity liquefaction of natural gas. In order to substantially increase the capacity, a Brayton refrigeration cycle with nitrogen expander was recently added to the cold end of the reputable propane pre-cooled mixed-refrigerant (C3-MR) process. Similar modifications with a nitrogen expander cycle are extensively investigated on a variety of cycle configurations. The existing and modified cycles are simulated with commercial process software (Aspen HYSYS) based on selected specifications. The results are compared in terms of thermodynamic efficiency, liquefaction capacity, and estimated size of heat exchangers. The combination of C3-MR with partial regeneration and pre-cooling of nitrogen expander cycle is recommended to have a great potential for high efficiency and large capacity.

42 ENGINEERING↗

OpenSAMPL: An Open Source Library for Timing and Synchronization Measurements and Analytics

Today's power grid operators are implementing timing and synchronization solutions that provide resilience to Global Navigation Satellite System (GNSS) vulnerabilities. These vendor-specific solutions often come with additional software applications that are designed to monitor that vendor's synchronization performance data. However, resilient timing architectures often resulting in multi-vendor solutions, including approaches that blend terrestrial clocks with space-based subscription services. In such an environment, collecting, analyzing, and visualizing data from a variety of sources within a single platform was heretofore not possible. To address this need, the US Department of Energy's Center for Alternative Synchronization and Timing (CAST) developed OpenSAMPL, the Open Synchronized Analytics and Monitoring Platform, an open-source Python framework for processing, loading, and observing clock measurement data from distributed devices. OpenSAMPL enables the ingestion of diverse clock-probe sources into a scalable time-series database and applies robust analytics. OpenSAMPL currently supports two vendor data pipelines, and will be extended to more in the near future, enabling seamless monitoring of a variety of timing and synchronization devices in a common environment.

Grant, Josh [ORNL] (ORCID:0000000163475060)↗

TU-CD-207-08: Intrinsic Image Quality Comparison of Synthesized 2-D and FFDM Images

Purpose: With the combined interest of managing patient dose, maintaining or improving image quality, and maintaining or improving the diagnostic utility of mammographic data, this study aims to compare the intrinsic image quality of Hologic’s synthesized 2-D (C-View) and 2-D FFDM images in terms of resolution, contrast, and noise. Methods: This study utilized a novel 3-D printed anthropomorphic breast phantom in addition to the American College of Radiology (ACR) mammography accreditation phantom. Analysis of the 3-D anthropomorphic phantom included visual assessment of resolution and analysis of the normalized noise power spectrum. Analysis of the ACR phantom included both visual inspection and objective automated analysis using in-house software. The software incorporates image- and object-specific CNR visibility thresholds which account for image characteristics such as noise texture which affect object visualization. T- test statistical analysis was also performed on ACR phantom scores. Results: The spatial resolution of C-View images is markedly lower (at least 50% worse) than that of FFDM. And while this is generally associated with the benefit of reduced relative noise magnitude, the noise in C-View images tends to have a more mottled (predominantly low-frequency) texture. In general, for high contrast objects, C-View provides superior visualization over FFDM; however this benefit diminishes for low contrast objects and is applicable only to objects that are sufficiently larger than the spatial resolution threshold. Based on both observer and automated ACR phantom analysis, between 50–70% of C-View images failed to meet ACR minimum accreditation requirements – primarily due to insufficient (unbroken) fiber visibility. Conclusion: Compared to FFDM, C-View offers better depiction of objects of certain size and contrast, but provides poorer overall resolution and noise properties. Based on these findings, the utilization of C-View images in the clinical setting requires careful consideration, especially if considering the discontinuation of FFDM imaging.

60 APPLIED LIFE SCIENCES↗

Development of a method to estimate organ doses for pediatric CT examinations

Purpose: To develop a method for estimating doses to primarily exposed organs in pediatric CT by taking into account patient size and automatic tube current modulation (ATCM). Methods: A Monte Carlo CT dosimetry software package, which creates patient-specific voxelized phantoms, accurately simulates CT exposures, and generates dose images depicting the energy imparted on the exposed volume, was used. Routine head, thorax, and abdomen/pelvis CT examinations in 92 pediatric patients, ranging from 1-month to 14-yr-old (49 boys and 43 girls), were simulated on a 64-slice CT scanner. Two sets of simulations were performed in each patient using (i) a fixed tube current (FTC) value over the entire examination length and (ii) the ATCM profile extracted from the DICOM header of the reconstructed images. Normalized to CTDI{sub vol} organ dose was derived for all primary irradiated radiosensitive organs. Normalized dose data were correlated to patient’s water equivalent diameter using log-transformed linear regression analysis. Results: The maximum percent difference in normalized organ dose between FTC and ATCM acquisitions was 10% for eyes in head, 26% for thymus in thorax, and 76% for kidneys in abdomen/pelvis. In most of the organs, the correlation between dose and water equivalent diameter was significantly improved in ATCM compared to FTC acquisitions (P < 0.001). Conclusions: The proposed method employs size specific CTDI{sub vol}-normalized organ dose coefficients for ATCM-activated and FTC acquisitions in pediatric CT. These coefficients are substantially different between ATCM and FTC modes of operation and enable a more accurate assessment of patient-specific organ dose in the clinical setting.

60 APPLIED LIFE SCIENCES↗

NOODLES [SWR-22-78]

NOODLES is a protocol specification for collaborative visualization. It allows software tools of any type to participate in an analysis or visualization session. Use cases include, but are not limited to, distributed analysis, workflow interoperability, computational steering, etc.

Brunhart-Lupo, Nicholas↗

Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado

To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In NREL's report titled 'Assessing and Improving the Accuracy of Energy Analysis of Residential Buildings,' researchers propose a method for improving the accuracy of residential energy analysis methods. A key step in this process involves the comparisons of predicted versus metered energy use and savings. In support of this research need, CARB evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. In this study, CARB seeks to improve the accuracy of modeling software while assessing retrofit measures to specifically determine which are most effective for large multifamily complexes in the cold climate region. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗