Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software reliability model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Verification and Validation of the New Dynamic Mooring Modules Available in FAST v8: Preprint

The open-source aero-hydro-servo-elastic wind turbine simulation software, FAST v8, was recently coupled to two newly developed mooring dynamics modules: MoorDyn and FEAMooring. MoorDyn is a lumped-mass-based mooring dynamics module developed by the University of Maine, and FEAMooring is a finite-element-based mooring dynamics module developed by Texas A&M University. This paper summarizes the work performed to verify and validate these modules against other mooring models and measured test data to assess their reliability and accuracy. The quality of the fairlead load predictions by the open-source mooring modules MoorDyn and FEAMooring appear to be largely equivalent to what is predicted by the commercial tool OrcaFlex. Both mooring dynamic model predictions agree well with the experimental data, considering the given limitations in the accuracy of the platform hydrodynamic load calculation and the quality of the measurement data.

17 WIND ENERGY↗

Verification and Validation of the New Dynamic Mooring Modules Available in FAST v8

The open-source aero-hydro-servo-elastic wind turbine simulation software, FAST v8, was recently coupled to two newly developed mooring dynamics modules: MoorDyn and FEAMooring. MoorDyn is a lumped-mass-based mooring dynamics module developed by the University of Maine, and FEAMooring is a finite-element-based mooring dynamics module developed by Texas A&M University. This paper summarizes the work performed to verify and validate these modules against other mooring models and measured test data to assess their reliability and accuracy. The quality of the fairlead load predictions by the open-source mooring modules MoorDyn and FEAMooring appear to be largely equivalent to what is predicted by the commercial tool OrcaFlex. Both mooring dynamic model predictions agree well with the experimental data, considering the given limitations in the accuracy of the platform hydrodynamic load calculation and the quality of the measurement data.

17 WIND ENERGY↗

Critical look at cosmological perturbation theory techniques

Recently, a number of analytic prescriptions for computing the nonlinear matter power spectrum have appeared in the literature. These typically involve resummation or closure prescriptions which do not have a rigorous error control, thus they must be compared with numerical simulations to assess their range of validity. We present a direct side-by-side comparison of several of these analytic approaches, using a suite of high-resolution N-body simulations as a reference, and discuss some general trends. All of the analytic results correctly predict the behavior of the power spectrum at the onset of nonlinearity, and improve upon a pure linear theory description at very large scales. All of these theories fail at sufficiently small scales. At low redshift the dynamic range in scale where perturbation theory is both relevant and reliable can be quite small. We also compute for the first time the two-loop contribution to standard perturbation theory for cold dark matter models, finding improved agreement with simulations at large redshift. At low redshifts however the two-loop term is larger than the one-loop term on quasilinear scales, indicating a breakdown of the perturbation expansion. Finally, we comment on possible implications of our results for future studies. A software package implementing the methods presented here is available at http://mwhite.berkeley.edu/Copter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using Micro-Synchrophasor Data for Advanced Distribution Grid Planning and Operations Analysis

This report reviews the potential for distribution-grid phase-angle data that will be available from new micro-synchrophasors (µPMUs) to be utilized in existing distribution-grid planning and operations analysis. This data could augment the current diagnostic capabilities of grid analysis software, used in both planning and operations for applications such as fault location, and provide data for more accurate modeling of the distribution system. µPMUs are new distribution-grid sensors that will advance measurement and diagnostic capabilities and provide improved visibility of the distribution grid, enabling analysis of the grid’s increasingly complex loads that include features such as large volumes of distributed generation. Large volumes of DG leads to concerns on continued reliable operation of the grid, due to changing power flow characteristics and active generation, with its own protection and control capabilities. Using µPMU data on change in voltage phase angle between two points in conjunction with new and existing distribution-grid planning and operational tools is expected to enable model validation, state estimation, fault location, and renewable resource/load characterization. Our findings include: data measurement is outstripping the processing capabilities of planning and operational tools; not every tool can visualize a voltage phase-angle measurement to the degree of accuracy measured by advanced sensors, and the degree of accuracy in measurement required for the distribution grid is not defined; solving methods cannot handle the high volumes of data generated by modern sensors, so new models and solving methods (such as graph trace analysis) are needed; standardization of sensor-data communications platforms in planning and applications tools would allow integration of different vendors’ sensors and advanced measurement devices. In addition, data from advanced sources such as µPMUs could be used to validate models to improve/ensure accuracy, providing information on normally estimated values such as underground conductor impedance, and characterization of complex loads. Although the input of high-fidelity data to existing tools will be challenging, µPMU data on phase angle (as well as other data from advanced sensors) will be useful for basic operational decisions that are based on a trend of changing data.

25 ENERGY STORAGE↗

Physics-Based Multi-State Models of Passive Component Degradation for the R7 Reactor Simulation Environment

Abstract: The Next Generation Systems Analysis Code - referred to as R7 - is reactor systems simulation software being developed to support the Risk-Informed Safety Margin Characterization Pathway of the U.S. Department of Energy's Light Water Reactor Sustainability Program. It will provide an integrated multi-physics environment, implemented in an uncertainty quantification (UQ) framework that can produce risk and other performance insights on long-term reactor operations. An element of this simulation environment will be the performance of passive components and materials. Conventional models of component reliability are largely parametric, relying on plant service data to estimate component lifetimes and failure rates. This type of model has limited usefulness in the R7 environment where the intent is to explicitly determine the influence of physical stressors on component degradation. In this paper, we describe a new class of multi-state physics-based component models designed to be R7-compatible. These models capture the physics of materials degradation while also incorporating the effects of interventions and component rejuvenation. The models are implemented in a cumulative damage framework that allows the impact of an evolving physical environment to be addressed without recourse to resampling within the Monte Carlo-based UQ framework. The paper describes an application to stress corrosion cracking in dissimilar metal welds - a principal contributor to potential loss of coolant accidents. So while R7 will have the more conventional capability of reactor simulation codes to model the impact of degraded components and systems on plant performance, the methodology described here allows R7 to model the inverse effect; the impact of the physical environment on component degradation and performance.

PRA, passive components, stress corrosion cracking↗

Cyber security analysis testbed : combining real, emulation, and simulation.

Cyber security analysis tools are necessary to evaluate the security, reliability, and resilience of networked information systems against cyber attack. It is common practice in modern cyber security analysis to separately utilize real systems of computers, routers, switches, firewalls, computer emulations (e.g., virtual machines) and simulation models to analyze the interplay between cyber threats and safeguards. In contrast, Sandia National Laboratories has developed novel methods to combine these evaluation platforms into a hybrid testbed that combines real, emulated, and simulated components. The combination of real, emulated, and simulated components enables the analysis of security features and components of a networked information system. When performing cyber security analysis on a system of interest, it is critical to realistically represent the subject security components in high fidelity. In some experiments, the security component may be the actual hardware and software with all the surrounding components represented in simulation or with surrogate devices. Sandia National Laboratories has developed a cyber testbed that combines modeling and simulation capabilities with virtual machines and real devices to represent, in varying fidelity, secure networked information system architectures and devices. Using this capability, secure networked information system architectures can be represented in our testbed on a single, unified computing platform. This provides an 'experiment-in-a-box' capability. The result is rapidly-produced, large-scale, relatively low-cost, multi-fidelity representations of networked information systems. These representations enable analysts to quickly investigate cyber threats and test protection approaches and configurations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Model Based Optimal Sensor Network Design for Condition Monitoring in an IGCC Plant

This report summarizes the achievements and final results of this program. The objective of this program is to develop a general model-based sensor network design methodology and tools to address key issues in the design of an optimal sensor network configuration: the type, location and number of sensors used in a network, for online condition monitoring. In particular, the focus in this work is to develop software tools for optimal sensor placement (OSP) and use these tools to design optimal sensor network configuration for online condition monitoring of gasifier refractory wear and radiant syngas cooler (RSC) fouling. The methodology developed will be applicable to sensing system design for online condition monitoring for broad range of applications. The overall approach consists of (i) defining condition monitoring requirement in terms of OSP and mapping these requirements in mathematical terms for OSP algorithm, (ii) analyzing trade-off of alternate OSP algorithms, down selecting the most relevant ones and developing them for IGCC applications (iii) enhancing the gasifier and RSC models as required by OSP algorithms, (iv) applying the developed OSP algorithm to design the optimal sensor network required for the condition monitoring of an IGCC gasifier refractory and RSC fouling. Two key requirements for OSP for condition monitoring are desired precision for the monitoring variables (e.g. refractory wear) and reliability of the proposed sensor network in the presence of expected sensor failures. The OSP problem is naturally posed within a Kalman filtering approach as an integer programming problem where the key requirements of precision and reliability are imposed as constraints. The optimization is performed over the overall network cost. Based on extensive literature survey two formulations were identified as being relevant to OSP for condition monitoring; one based on LMI formulation and the other being standard INLP formulation. Various algorithms to solve these two formulations were developed and validated. For a given OSP problem the computation efficiency largely depends on the “size” of the problem. Initially a simplified 1-D gasifier model assuming axial and azimuthal symmetry was used to test out various OSP algorithms. Finally these algorithms were used to design the optimal sensor network for condition monitoring of IGCC gasifier refractory wear and RSC fouling. The sensors type and locations obtained as solution to the OSP problem were validated using model based sensing approach. The OSP algorithm has been developed in a modular form and has been packaged as a software tool for OSP design where a designer can explore various OSP design algorithm is a user friendly way. The OSP software tool is implemented in Matlab/Simulink© in-house. The tool also uses few optimization routines that are freely available on World Wide Web. In addition a modular Extended Kalman Filter (EKF) block has also been developed in Matlab/Simulink© which can be utilized for model based sensing of important process variables that are not directly measured through combining the online sensors with model based estimation once the hardware sensor and their locations has been finalized. The OSP algorithm details and the results of applying these algorithms to obtain optimal sensor location for condition monitoring of gasifier refractory wear and RSC fouling profile are summarized in this final report.

20 FOSSIL-FUELED POWER PLANTS↗

Editorial: Neuroscience, computing, performance, and benchmarks: Why it matters to neuroscience how fast we can compute

At the turn of the millennium the computational neuroscience community realized that neuroscience was in a software crisis: software development was no longer progressing as expected and reproducibility declined. The International Neuroinformatics Coordinating Facility (INCF) was inaugurated in 2007 as an initiative to improve this situation. The INCF has since pursued its mission to help the development of standards and best practices. In a community paper published this very same year, Brette et al. tried to assess the state of the field and to establish a scientific approach to simulation technology, addressing foundational topics, such as which simulation schemes are best suited for the types of models we see in neuroscience. In 2015, a Frontiers Research Topic “Python in neuroscience” by Muller et al. triggered and documented a revolution in the neuroscience community, namely in the usage of the scripting language Python as a common language for interfacing with simulation codes and connecting between applications. The review by Einevoll et al. documented that simulation tools have since further matured and become reliable research instruments used by many scientific groups for their respective questions. Open source and community standard simulators today allow research groups to focus on their scientific questions and leave the details of the computational work to the community of simulator developers. A parallel development has occurred, which has been barely visible in neuroscientific circles beyond the community of simulator developers: Supercomputers used for large and complex scientific calculations have increased their performance from ~10 TeraFLOPS (10 13 floating point operations per second) in the early 2000s to above 1 ExaFLOPS (10 18 floating point operations per second) in the year 2022. This represents a 100,000-fold increase in our computational capabilities, or almost 17 doublings of computational capability in 22 years. Moore's law (the observation that it is economically viable to double the number of transistors in an integrated circuit every other 18–24 months) explains a part of this; our ability and willingness to build and operate physically larger computers, explains another part. It should be clear, however, that such a technological advancement requires software adaptations and under the hood, simulators had to reinvent themselves and change substantially to embrace this technological opportunity. It actually is quite remarkable that—apart from the change in semantics for the parallelization—this has mostly happened without the users knowing. The current Research Topic was motivated by the wish to assemble an update on the state of neuroscientific software (mostly simulators) in 2022, to assess whether we can see more clearly which scientific questions can (or cannot) be asked due to our increased capability of simulation, and also to anticipate whether and for how long we can expect this increase of computational capabilities to continue.

biophysically detailed models↗

Enhanced Boundary Layer Height Detection Using Ceilometer, Surface Meteorology, and Radiation Products With a Random Forest Ensemble Method

This study develops and evaluates a Random Forest (RF) model for estimating planetary boundary layer height (PBLH) using 9 years of data from the Atmospheric Radiation Measurement Southern Great Plains (ARM SGP) user facility, with potential application in the NOAA Surface Radiation (SURFRAD) Network. The model integrates ceilometer, surface meteorology, and radiation measurements, and is trained using thermodynamic PBLH estimates derived from radiosondes. This approach aims to bridge gaps between aerosol-based and thermodynamic-based PBLH estimates. The RF model outperformed traditional methods during daytime and better captured transition periods, demonstrating improved accuracy and robustness. At ARM SGP, it showed a substantial reduction in both bias and RMSE, with a bias near zero (−4.9 m) compared with traditional Haar Wavelet (HW) (70.9 m) and Vaisala BL-View software (124.1 m), and an RMSE of 303.2 m, lower than both BL-View (566.9 m) and HW (404.6 m). During daytime hours, RF consistently outperformed both alternatives, maintaining lower bias and RMSE across all periods. At a second evaluation site, RF achieved the lowest overall RMSE (323.7 m), similar to HW (326.4 m) and significantly better than BL-View (738.3 m). However, all models showed reduced accuracy under stable nighttime conditions, limiting the reliability of PBLH estimates. Key predictors for the model included the lifting condensation level height (LCLH), aerosol gradients, and month for seasonal variability. The study underscores the potential of integrating machine learning with multiple data sets such as surface energy and thermodynamic data to advance PBLH estimation.

boundary layer height↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Thermal-mechanical modeling of deep borehole disposal of high-level radioactive waste.

Disposal of high-level radioactive waste, including spent nuclear fuel, in deep (3 to 5 km) boreholes is a potential option for safely isolating these wastes from the surface and near-surface environment. Existing drilling technology permits reliable and cost-effective construction of such deep boreholes. Conditions favorable for deep borehole disposal in crystalline basement rocks, including low permeability, high salinity, and geochemically reducing conditions, exist at depth in many locations, particularly in geologically stable continental regions. Isolation of waste depends, in part, on the effectiveness of borehole seals and potential alteration of permeability in the disturbed host rock surrounding the borehole. Coupled thermal-mechanical-hydrologic processes induced by heat from the radioactive waste may impact the disturbed zone near the borehole and borehole wall stability. Numerical simulations of the coupled thermal-mechanical response in the host rock surrounding the borehole were conducted with three software codes or combinations of software codes. Software codes used in the simulations were FEHM, JAS3D, Aria, and Adagio. Simulations were conducted for disposal of spent nuclear fuel assemblies and for the higher heat output of vitrified waste from the reprocessing of fuel. Simulations were also conducted for both isotropic and anisotropic ambient horizontal stress in the host rock. Physical, thermal, and mechanical properties representative of granite host rock at a depth of 4 km were used in the models. Simulation results indicate peak temperature increases at the borehole wall of about 30 C and 180 C for disposal of fuel assemblies and vitrified waste, respectively. Peak temperatures near the borehole occur within about 10 years and decline rapidly within a few hundred years and with distance. The host rock near the borehole is placed under additional compression. Peak mechanical stress is increased by about 15 MPa (above the assumed ambient isotropic stress of 100 MPa) at the borehole wall for the disposal of fuel assemblies and by about 90 MPa for vitrified waste. Simulated peak volumetric strain at the borehole wall is about 420 and 2600 microstrain for the disposal of fuel assemblies and vitrified waste, respectively. Stress and volumetric strain decline rapidly with distance from the borehole and with time. Simulated peak stress at and parallel to the borehole wall for the disposal of vitrified waste with anisotropic ambient horizontal stress is about 440 MPa, which likely exceeds the compressive strength of granite if unconfined by fluid pressure within the borehole. The relatively small simulated displacements and volumetric strain near the borehole suggest that software codes using a nondeforming grid provide an adequate approximation of mechanical deformation in the coupled thermal-mechanical model. Additional modeling is planned to incorporate the effects of hydrologic processes coupled to thermal transport and mechanical deformation in the host rock near the heated borehole.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the optimal sizing of power take-off systems for wave energy converters

The power take-off (PTO) system in a wave energy converter (WEC) is the means by which the energy in an ocean wave is converted into useful energy. There has been a general lack of technology convergence in the wave energy industry and PTO design has been largely device-specific with the design process determined by the WEC developer. An optimized PTO design can significantly affect the efficiency, reliability, performance, and overall cost and viability of a device. There remains a need in the marine energy industry for best practices and efficient design processes to be identified as it could greatly benefit developers and researchers in designing an optimal WEC PTO. This research utilizes the open-source Matlab-Simulink based software, WEC-Sim, which was developed by the National Renewable Energy Laboratory, and the Eagle, a high-performance computing system, to model and optimize two WECs of different archetypes and then investigates if any trends exist that can be exploited for greater efficiency in optimal PTO design. The results from this research indicate that there may be an optimal sizing for WEC PTOs for both power and PTO force rating and that substantial reductions can be made in the cost of a device without significant loss in the energy produced. Furthermore this optimal sizing may be independent of WEC type and deployment location. With an optimal, or near optimal, approach to WEC PTO sizing demonstrated, a methodology is proposed to address the challenge of nameplate ratings in the wave energy industry.

13 HYDRO ENERGY↗

Phoebe: a high-performance framework for solving phonon and electron Boltzmann transport equations

Understanding the electrical and thermal transport properties of materials is critical to the design of electronics, sensors, and energy conversion devices. Computational modeling can accurately predict material properties but, in order to be reliable, requires accurate descriptions of electron and phonon states and their interactions. While first-principles methods are capable of describing the energy spectrum of each carrier, using them to compute transport properties is still a formidable task, both computationally demanding and memory intensive, requiring integration of fine microscopic scattering details for estimation of macroscopic transport properties. To address this challenge, we present Phoebe—a newly developed software package that includes the effects of electron–phonon, phonon–phonon, boundary, and isotope scattering in computations of electrical and thermal transport properties of materials with a variety of available methods and approximations. This open source C++ code combines MPI-OpenMP hybrid parallelization with GPU acceleration and distributed memory structures to manage computational cost, allowing Phoebe to effectively take advantage of contemporary computing infrastructures. We demonstrate that Phoebe accurately and efficiently predicts a wide range of transport properties, opening avenues for accelerated computational analysis of complex crystals.

36 MATERIALS SCIENCE↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Investigating Various Failure Models on Commercial Silicon Carbide

Structures and components made from ceramic materials are often brittle and can fail by the unstable growth of existing flaws such as voids and cracks. There have been several failure criteria developed for ceramics, in the past and they are broadly categorized based on their dependency on crack geometry. The present work implements eight failure criteria using an open-source software package – srlife, which predicts the lifetime or failure probability of concentrated solar power (CSP) structural components. The present work also checks the viability of building a ceramic CSP receiver, by analyzing the reliability predictions from srlife for a SiC ceramic. The reliability predictions for a biaxial loading problem indicated the Shetty Mixed-Mode criterion gives the most conservative predictions. Whereas, in case of the CSP receiver, the predictions show that the co-planar strain energy criterion gives the most conservative predictions as it is agnostic towards the type of stress, and therefore, is not recommended to be used designing ceramic receivers.

Chaugule, Pawan (ORCID:0000000275706572)↗

Performing Numerical Analysis of Cybersecurity Options Using Dynamic Risk Analysis Tool EMRALD

Cyberattacks can have many different attack paths, durations, and goals. There are also many different mitigation options involving hardware, software, and/or humans. Considering a cyber threat should involve defense-in-depth methods and a quantitative or numerical evaluation of overall effectiveness against dynamic, time-dependent attacks to make cost and risk-informed decisions. Typical cyberattack modeling methods only provide a qualitative evaluation. The main areas of cybersecurity are confidentiality, integrity, and availability. For companies with cyber-physical systems such as advanced nuclear reactors, cyber-related safety is a requirement set by North American Electric Reliability and the U.S. Nuclear Regulatory Commission. They are also concerned about availability or reliability as a business case. As cyber threats are evolving to a business-for-hire structure, more attacks may focus on disrupting business success and reliability, causing financial and economic stability risk. Companies want to know business reliability and recovery from those threats, and that requires modeling physical behavior of the targets. Dynamic-state-based and Markov-based modeling provides a method for better cyber scenario modeling with different tools having issues such as state-base explosion. Dynamic modeling enables time and conditional features not found in other numerical evaluation methods. EMRALD (Event Modeling Risk Assessment using Lined Diagrams) is a dynamic risk analysis modeling and simulation tool and has features that reduce modeling issues. It has been used to model different time-dependent events including plant behavior and operator procedures. As a general modeling tool, EMRALD can also be used to model cyberattack scenarios with varying mitigation options and quantify effectiveness, producing numerical data for risk-informed decisions. This paper uses EMRALD to demonstrate that dynamic numerical risk analysis can be used for cyber threat modeling to provide insights for design decision-making and optimize defense strategies. Keywords: cyber modeling; cyber-physical systems; numerical cyber modeling

97 - MATHEMATICS AND COMPUTING↗

Methodology for the Incorporation of Passive Component Aging Modeling into the RAVEN/ RELAP-7 Environment

Passive system, structure and components (SSCs) will degrade over their operation life and this degradation may cause to reduction in the safety margins of a nuclear power plant. In traditional probabilistic risk assessment (PRA) using the event-tree/fault-tree methodology, passive SSC failure rates are generally based on generic plant failure data and the true state of a specific plant is not reflected realistically. To address aging effects of passive SSCs in the traditional PRA methodology [1] does consider physics based models that account for the operating conditions in the plant, however, [1] does not include effects of surveillance/inspection. This paper represents an overall methodology for the incorporation of aging modeling of passive components into the RAVEN/RELAP-7 environment which provides a framework for performing dynamic PRA. Dynamic PRA allows consideration of both epistemic and aleatory uncertainties (including those associated with maintenance activities) in a consistent phenomenological and probabilistic framework and is often needed when there is complex process/hardware/software/firmware/ human interaction [2]. Dynamic PRA has gained attention recently due to difficulties in the traditional PRA modeling of aging effects of passive components using physics based models and also in the modeling of digital instrumentation and control systems. RAVEN (Reactor Analysis and Virtual control Environment) [3] is a software package under development at the Idaho National Laboratory (INL) as an online control logic driver and post-processing tool. It is coupled to the plant transient code RELAP-7 (Reactor Excursion and Leak Analysis Program) also currently under development at INL [3], as well as RELAP 5 [4]. The overall methodology aims to: • Address multiple aging mechanisms involving large number of components in a computational feasible manner where sequencing of events is conditioned on the physical conditions predicted in a simulation environment such as RELAP-7. • Identify the risk-significant passive components, their failure modes and anticipated rates of degradation • Incorporate surveillance and maintenance activities and their effects into the plant state and into component aging progress. • Asses aging affects in a dynamic simulation environment 1. C. L. SMITH, V. N. SHAH, T. KAO, G. APOSTOLAKIS, “Incorporating Ageing Effects into Probabilistic Risk Assessment –A Feasibility Study Utilizing Reliability Physics Models,” NUREG/CR-5632, USNRC, (2001). 2. T. ALDEMIR, “A Survey of Dynamic Methodologies for Probabilistic Safety Assessment of Nuclear Power Plants, Annals of Nuclear Energy, 52, 113-124, (2013). 3. C. RABITI, A. ALFONSI, J. COGLIATI, D. MANDELLI and R. KINOSHITA “Reactor Analysis and Virtual Control Environment (RAVEN) FY12 Report,” INL/EXT-12-27351, (2012). 4. D. ANDERS et.al, "RELAP-7 Level 2 Milestone Report: Demonstration of a Steady State Single Phase PWR Simulation with RELAP-7," INL/EXT-12-25924, (2012).

97 MATHEMATICS AND COMPUTING↗