Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small scale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Small-scale structure of the CO emission in S255 from lunar occultation observations

Two lunar occultations of the S255 H II region/molecular cloud complex were observed in the 2.6 mm CO line during 1978 and 1979. The resolution obtained (between 4 arcsec and 7 arcsec) enables us to resolve bright sources that are much smaller than the 44 arcsec telescope beam. In addition to the large-scale structure (approximately 10 arcmin in size) seen in previous CO maps, the observations reveal two high-temperature emission regions in the cloud core associated with two compact infrared sources about 20 arcsec apart. The first CO hot spot is larger in size with a Gaussian width of 41 arcsec + or - 7 arcsec and a peak temperature of 65 K. Its center falls between the two small infrared sources S255 IRS1 and IRS2. The linear size and peak temperature of this source are remarkably similar to those in the Orion Kleinmann-Low nebula. The second source is revealed from a discontinuous change in the CO line flux as the lunar limb crossed S255 IRS1. The size of this component is less than 7 arcsec; its temperature must exceed 200 K. No evidence is found for exceptionally high temperatures at the boundary of the two H II regions crossed during the occultations.

Schloerb, F. P.↗

Small Scale Polygons and the History of Ground Ice on Mars

Recent progress on polygon modeling has focused on the diameter and surface relief that we expect of thermal-contraction polygons in martian permafrost. With this in mind, we developed a finite-element model of thermal-contraction-crack behavior in permafrost in a martian climate. This model was generated from a finite element code by Jay Melosh (called TECTON) originally developed for terrestrial and planetary crustal-deformation studies. We adapted this model to martian permafrost by including time (and temperature) dependent rheologies, boundary conditions, and isotropic thermal-contraction, as well as several small adaptations to a martian environment. We tested our model extensively, including comparison to an analytic solution of pre-fracture stress. We recently published an analysis of two potential sources of water for forming the recent gullies. In this work we first evaluated the potential for near-surface ground ice (in the top meter or so of soil) to melt under conditions of solar heating on sloped surfaces at high obliquity, utilizing both thermal and diffusion-based ground-ice-stability models; our results suggested that the ground ice will sublimate, and the ice table will recede to greater depths before the melting temperature can be reached. An exception can occur only for extremely salt-rich ice, depressing the freezing point.

Mellon, Michael T.↗

Cloud and convection frequencies over the southeast United States as related to small-scale geographic features

Based on relatively high spatial and temporal resolution satelite data collected at 0700 CST and at each hour from 1000 CST to 1700 CST during the summer of 1986, cloud and convection variations over the area from Mississippi east to Georgia and from the Gulf of Mexico north to Tennessee are discussed. The data analyses show an average maximum cloud frequency over the land areas at 1400 local time and a maximum of deep convection one hour later. Both cloudiness and deep convection are found to be at a maximum during the nocturnal hours over the Gulf of Mexico. Cloud frequency shows a strong relationship to small terrain features. Small fresh water bodies have cloud minima relative to the surroundings in the afternoon hours. Higher, steep terrain shows cloud maxima and the adjacent lower terrain exhibits afternoon cloud minima due to a divergence of mountain breeze caused by the valley.

Gibson, Harold M.↗

Small-scale structure of O2(+) and proton hydrates in a Noctilucent Cloud and polar mesospheric summer echo of August 9/10 1991 above Kiruna

A novel mass spectrometer designed to measure simultaneously positive ion composition in the mesosphere, was successfully launched during the NLC-91 project. Instruments supporting the mass spectrometer were a probed to measure both electrons and positive ions as well as a wave propagation experiment. The location of the Noctilucent Clouds (NLC) was determined by a particle impact sensor to detect secondary electrons and ions from the impact of NLC particle. The density of proton hydrates and of the related total ions is depleted in the NLC region at 83 km. An improved detection limit of 5 x 10(exp 4)/cu m for positive ions and improved height resolution revealed for the first time large gradients in the O2(+), H(+)(H2O)2 and H(+)(H2O)6 densities within a small height range of the order of 50 m. Such gradients at the altitude of NLC and Polar Mesospheric Summer Echoes (PMSE) are associated with strong variability of mesospheric water vapor, temperature and neutral air density.

Balsiger, F.↗

Pervasive small-scale structure in molecular clouds

An unbiased CO survey of molecular cloud cores was completed, and the profiles were analyzed within the context of a model for emission from clumpy clouds. It was found that all sources observed contain a significant amount of structure that is not resolved with our 2.3-arcmin beam, and that the parameters which describe the degree of clumping span a remarkably narrow range of the possible values. We studied two separate samples of cloud cores: a large sample of warm cores from the Massachusetts-Stony Brook 12CO survey of the first galactic quadrant, and a sample of cool cores in the Taurus dark clouds chosen primarily on the basis of H2CO emission. We observed all sources in the 1-0 transition of 12CO and 13CO with the 5-m telescope of the Millimeter Wave Observatory. The 12CO/13CO ratios can be explained if there is unresolved structure giving rise to significant variations of opacity across the beam. Our model cloud consists of a large number of identical clumps distributed randomly in the beam. These clumps have velocity widths v small compared to the width of the observed profile, which is determined by the relative motion of the clumps. The entire cloud is isothermal and in local thermodynamic equilibrium. With these assumptions the intensity and linewidth ratios depend on three parameters: the abundance ratio; the peak 13CO opacity through a single clump, tau(0); and the average number of clumps on a line of sight N. Small tau(0) and large N correspond to the microturbulent limit, which is indistinguishable from a uniform gas distribution. In the other extreme, large tau(0) and snall N, at a given velocity at most one clump contributes to the profile on each line of sight. A figure is presented which shows the model parameters which reproduce the measured intensity and linewidth ratios for the sample of warm cores, assuming an abundance ratio of 75.

Martin, B.↗

Recent Work at Langley Research Center in the Development of a Graphite-Heated Small-Scale Hypersonic Nitrogen Tunnel

It is the purpose of this paper to discuss the development of and to present some preliminary data results which were obtained during the operation of a high-pressure-high-temperature induction-type heat exchanger. The subjects to be covered are: (1) An overall description of the induction heater and the various graphite elements tested in the heater; (2) Effects of the mass rate of flow on stagnation temperature; (3) Heat-transfer data on one heater element; (4) Effect of power input on gas stagnation temperature, and (5) The evaluation of mass flow technique as a method for determining true gas stagnation temperature.

HEAT EXCHANGER↗

Oxygen-hydrogen torch is a small-scale steam generator

Standard oxygen-hydrogen torch generates steam for corrosion-rate analysis of various metals. The steam is generated through local combustion inside a test chamber under constant temperature and pressure control.

Maskell, C. E.↗