Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shielding design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Parallel Monte Carlo Methods for Heterogeneous Hardware Computer Systems Using GPUs and Coprocessors: Recent Development of ARCHER Code - Paper 54

Traditional methods of accelerating Monte Carlo (MC) calculations typically use CPUs as the computing unit. The parallelism is based upon multithreading on a multi-core processor, and message passing interface (MPI) across many processors and nodes. In recent years, the hardware accelerators have been introduced by the high performance computing industry as an alternative approach to achieve massive parallelism. Hardware accelerators have the advantage of high Floating-point Operations Per Second (FLOPS) and high energy efficiency. Examples include graphics processing units (GPUs) and coprocessors. Compute-intensive programs can be off-loaded to them to be concurrently executed by hundreds or thousands of active threads. Existing production MC codes, however, cannot be directly compiled or executed on the new platforms. It is therefore necessary to rewrite or redevelop the code using the hardware accelerator specific programming models and APIs. Several studies have been conducted on using GPUs to accelerate MC calculations in reactor analysis and medical physics. In this paper, we present the recent progress at Rensselaer Polytechnic Institute (RPI) in developing a new parallel MC code called ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environments) for coupled photon-electron transport simulations. The code is designed as a test bed to evaluate the efficacy of heterogeneous computing systems for low-cost MC-based radiation dosimetric calculations. The code has three variants corresponding to three parallel hardware platforms: ARCHER-CPU (multi-core CPU), ARCHER-GPU (Nvidia GPU) and ARCHER-COP (Intel Xeon Phi coprocessor). The code has been used for several applications, including CT imaging dosimetry, radiotherapy dosimetry and radiation shielding design. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

FRIB Fragment Pre-separator Radiation Environment Studies - Paper 133

The Facility for Rare Isotope Beams (FRIB), a project supported by the US DOE Office of Science, is under construction at Michigan State University. The project will use projectile fragmentation and induced in-flight fission of heavy ion beams at energies of 200 MeV/u and higher, and at a beam power of 400 kW, to produce rare isotope beams for nuclear physics experiments. The production of rare isotope beams during FRIB operations creates a high radiation environment in the fragment pre-separator area where the production target is located. Adequate shielding must be placed around the beam line components to ensure personnel protection during and after the operations. Detailed radiation transport studies in the fragment pre-separator area are necessary and have been performed for proper shielding choices. We calculate neutron and photon fluxes and their energy distributions, and evaluate prompt and residual dose equivalent rates in the hot cell and prompt dose equivalent rates in the MSM gallery outside of the cell where people might be present during normal operations. We also calculate dose equivalent rates in the MSM gallery when the activated components are placed in front of the MSM lead glass window on the hot cell side. We show that the resulting dose equivalent rates are conservative even for the most neutron-rich energetic beams. These calculations guide local shielding design and support operations. (authors)

43 PARTICLE ACCELERATORS↗

The NASA Radiation Health Program

The Space Radiation Health Program (SRHP) is defined in terms of motivation and methodology with specific reference given to the impacts of HZE particles and solar energetic particles. The biological hazards are mentioned that can be associated with the two particle types and ionizing radiation in general. The lack of data on the impact of such radiation and effective shielding countermeasures is identified as the primary motivation for worst-case assumptions. However, the resulting shielding designs can potentially overestimate the thickness by a factor of 10 and add unnecessarily to vehicle take-off mass. A space-based validation system is proposed to complement ground-based investigations of the effects of ionizing radiation in interplanetary space. The Lifesat satellite is proposed as a part of the SRHP effort to determine the requirements for protection and future shielding specifications.

Schimmerling, Walter↗

A Review of Tungsten Heavy Alloy Utilization in Isotope Transport Containers - 13380

A common requirement for radioisotope transport containers is that they provide both durable and efficient shielding of penetrating gamma radiation. This is the case for transport of both spent nuclear fuel as well as intentionally created radioisotopes for medical or other uses. Tungsten heavy alloy (WHA) provides a unique engineering property set for such shielding - easily surpassing more commonly used lead alloys in both strength and attenuation. This family of alloys contains typically 90-98 wt.% W in combination with transition metals such as Ni and Fe. WHA is manufactured in near net shape blanks by liquid phase sintering of compacted powder shapes to full metallurgical density parts. This powder metallurgy approach is described in its ability to provide excellent material utilization and affords efficient manufacturing of various shapes required for gamma shields or collimators. WHAs offer very high density (approaching 19 g/cc) in combination with relatively high thermal conductivity, low thermal expansion, ambient corrosion resistance, and can be provided with mechanical properties comparable to many medium carbon steels. As such, they can be machined to complex, damage resistant geometries using common metal cutting tools and methods. WHA additionally provides a lower toxicity alternative to Pb- or U-based gamma shielding. Given the specialty nature of WHA, specific metallurgical characteristics are reviewed to assist shielding designers who may otherwise encounter difficulties locating important alloy selection and fabrication details. Contained within this materials and applications overview are guidelines for WHA component design, alloy selection, and practical machining, finishing, and assembly considerations. The microstructure of WHA is that of a metal matrix composite. This factor has specific implications in the design of components for stress service as well as their protection in the presence of electrolytes. WHA is also discussed in the broader context of materials compatibility, as it is rarely used in isolated monolithic shapes. Alloy selection for new applications is often made primarily on the basis of density. An alternative strategy to this selection approach is presented which proposes that mechanical requirements for a given shielding use be the primary selection criterion over density. Standard commercial grades of WHA for radiation shielding are defined by specifications such as AMS-T-21014 and ASTM B777. These specifications define 4 density classes of as-sintered WHA. Compositional options, as well as post-sinter processing of WHA, are discussed for shielding components that must exhibit higher levels of ductility or very low magnetic permeability. In addition to the mechanical advantages over Pb-based shielding, the higher linear attenuation of energetic photons for various grades of WHA (as calculated by the NIST XCOM routine) are presented for selected photon energies of interest to illustrate the shield volume reduction generally possible through the use of tungsten-based shielding. While W provides inefficient attenuation of neutrons in a mixed radiation environment, its secondary role in shielding gamma radiation produced as a result of neutron capture is also described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Workload and transmission data for the installation of a digital breast tomosynthesis system

Purpose: Digital breast tomosynthesis (DBT) differs from conventional mammography in target/filter, kVp range, and imaging geometry. The aim of this study was to assess the breast input exposure of a DBT system by completing a workload survey of DBT installations, and to determine the parameters {alpha}, {beta}, and {gamma} in the Archer equation for the primary radiation generated by the clinical workload distributions. Methods: The authors conducted a retrospective survey of the x-ray breast imaging performed between September 2011 and September 2012 in three clinical DBT rooms equipped with Selenia Dimensions systems (Hologic Inc., Bedford, MA). A total of 343 examinations were analyzed to calculate the workload (mA-minute) and the primary air kerma at 1 m from the source (K{sup 1}). Transmission curves were calculated for the primary radiation generated by the workload distributions of the DBT rooms, and were fitted to the Archer equation. Results: There were large variations in patient volume and workload in the three examination rooms. In all these rooms, the average tube voltage (kVp) was about 31, the average K{sup 1} per patient was 16-21 mGy, and the average mA-minute per patient was 1.4-2.2 times higher than that of the mammography room described in NCRP Report No. 147. Most DBT screening examinations consisted of four two-dimensional mammographic views plus four tomosynthesis scans; the numbers of views acquired in diagnostic examinations varied widely. Tomosynthesis scans contributed about 30% of total mA-minute and about 50% of K{sup 1}. For the primary radiation generated by the clinical workload distributions, {alpha} was similar to that of 40-45 kVp W/Al (target/filter), and {alpha}+{beta} was similar to that of 30 kVp W/Al. Conclusions: The workload (mA-minute and K{sup 1}) distributions of mammographic examinations with DBT differ from conventional mammography. A field survey of patient volume and x-ray tube usage is important for the shielding design of DBT facilities. The clinical workloads and transmission data presented in this paper may be useful for clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of Graphical User Interface for ARRBOD (Acute Radiation Risk and BRYNTRN Organ Dose Projection)

The space radiation environment, particularly solar particle events (SPEs), poses the risk of acute radiation sickness (ARS) to humans; and organ doses from SPE exposure may reach critical levels during extra vehicular activities (EVAs) or within lightly shielded spacecraft. NASA has developed an organ dose projection model using the BRYNTRN with SUMDOSE computer codes, and a probabilistic model of Acute Radiation Risk (ARR). The codes BRYNTRN and SUMDOSE, written in FORTRAN, are a Baryon transport code and an output data processing code, respectively. The ARR code is written in C. The risk projection models of organ doses and ARR take the output from BRYNTRN as an input to their calculations. BRYNTRN code operation requires extensive input preparation. With a graphical user interface (GUI) to handle input and output for BRYNTRN, the response models can be connected easily and correctly to BRYNTRN in friendly way. A GUI for the Acute Radiation Risk and BRYNTRN Organ Dose (ARRBOD) projection code provides seamless integration of input and output manipulations, which are required for operations of the ARRBOD modules: BRYNTRN, SUMDOSE, and the ARR probabilistic response model. The ARRBOD GUI is intended for mission planners, radiation shield designers, space operations in the mission operations directorate (MOD), and space biophysics researchers. The ARRBOD GUI will serve as a proof-of-concept example for future integration of other human space applications risk projection models. The current version of the ARRBOD GUI is a new self-contained product and will have follow-on versions, as options are added: 1) human geometries of MAX/FAX in addition to CAM/CAF; 2) shielding distributions for spacecraft, Mars surface and atmosphere; 3) various space environmental and biophysical models; and 4) other response models to be connected to the BRYNTRN. The major components of the overall system, the subsystem interconnections, and external interfaces are described in this report; and the ARRBOD GUI product is explained step by step in order to serve as a tutorial.

Kim, Myung-Hee↗

Plasma shield for in-air beam processes

A novel concept/apparatus, the Plasma Shield, is introduced in this paper. The purpose of the Plasma Shield is designed to shield a target object chemically and thermally by engulfing an area subjected to beam treatment with inert plasma. The shield consists of a vortex-stabilized arc that is employed to shield beams and workpiece area of interaction from an atmospheric or liquid environment. A vortex-stabilized arc is established between a beam generating device (laser, ion or electron gun) and a target object. The arc, which is composed of a pure noble gas, engulfs the interaction region and shields it from any surrounding liquids like water or reactive gases. The vortex is composed of a sacrificial gas or liquid that swirls around and stabilizes the arc. The successful Plasma Shield was experimentally established and very high-quality electron beam welding with partial plasma shielding was performed. The principle of the operation and experimental results are discussed in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light charged ion measurements and Monte Carlo calculations from thick targets bombarded by protons and heavy ions - 25435

The data presented in this work are from experiments performed in November 2016 and November 2017 at the National Aeronautics and Space Administration (NASA) Space Radiation Laboratory at Brookhaven National Laboratory (BNL). The secondary light charged ions (Z=1 and 2 ions) and neutrons produced by 400-, 800-, and 2500-AMeV protons and 400-, 800-, and 1500-AMeV He, C, Si, Fe ions bombarding thick targets (20, 40, and 60 g/cm{sup 2} aluminum and high-density polyethylene (HDPE), and 20 and 60 g/cm{sup 2} combination of aluminum and HDPE) were measured with organic liquid scintillators and sodium iodide (NaI) detectors. The organic liquid scintillators were positioned at 10 deg., 30 deg., 45 deg., 60 deg., 80 deg., and 135 deg. with respect to the beam direction, while NaI detectors were placed at 10 deg. and 30 deg. off the beam axis. The double-differential thick-target secondary light charged ion yields measured by organic liquid scintillators are of main interest here. In the analysis, after applying pulse shape discrimination to separate protons, deuterons, tritons, helium-3, and helium-4 particles, the time of flight technique was used to produce the secondary charged particle angular-energy spectra. Additionally, the spectra were compared with simulation results using the Monte Carlo simulation code, PHITS version 2.88. To obtain favorable statistics in PHITS calculations, ring-type detectors were modeled, which have the same distances and equivalent angles with the experimental setup. These experimental data will be integrated into the uncertainty analysis for NASA to optimize future GCR shielding design. (authors)

43 PARTICLE ACCELERATORS↗

Steam Dryer Segmentation and Packaging at Grand Gulf Nuclear Station - 13577

Entergy recently performed an Extended Power Up-rate (EPU) on their Grand Gulf Nuclear Station, near Port Gibson, Mississippi. To support the EPU, a new Steam Dryer Assembly was installed during the last refueling outage. Due to limited access into the containment, the large Replacement Steam Dryer (RSD) had to be brought into the containment in pieces and then final assembly was completed on the refueling floor before installation into the reactor. Likewise, the highly contaminated Original Steam Dryer (OSD) had to be segmented into manageable sections, loaded into specially designed shielded containers, and rigged out of containment where they will be safely stored until final disposal is accomplished at an acceptable waste repository. Westinghouse Nuclear Services was contracted by Entergy to segment, package and remove the OSD from containment. This work was performed on critical path during the most recent refueling outage. The segmentation was performed underwater to minimize radiation exposure to the workers. Special hydraulic saws were developed for the cutting operations based on Westinghouse designs previously used in Sweden to segment ABB Reactor Internals. The mechanical cutting method was selected because of its proven reliability and the minimal cutting debris that is generated by the process. Maintaining stability of the large OSD sections during cutting was accomplished using a custom built support stand that was installed into the Moisture Separator Pool after the Moisture Separator was installed back in the reactor vessel. The OSD was then moved from the Steam Dryer Pool to the Moisture Separator Pool for segmentation. This scenario resolved the logistical challenge of having two steam dryers and a moisture separator in containment simultaneously. A water filtration/vacuum unit was supplied to maintain water clarity during the cutting and handling operations and to collect the cutting chips. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Transport properties associated with carbon-phenolic ablators

Entry vehicle heat shields designed for entry into the atmosphere of the outer planets are usually made of carbonaceous material such as carbon-phenolic ablator. Ablative injection of this material is an important mechanism for reducing the heat at the surface of the entry vehicle. Conductive transport properties in the shock layer are important for some entry conditions. The kinetic theory of gases has been used to calculate the transport properties for 17 gaseous species obtained from the ablation of carbon-phenolic heat shields. Results are presented for the pure species and for the gas mixture.

Biolsi, L.↗

LOW SCATTER, HIGH KILOVOLT, A-SI FLAT PANEL X-RAY DETECTOR

We have been using amorphous silicon (a-Si) flat panel detectors in high energy (>400 kV) cone beam computed tomography (CT) applications for a number of years. We have found that these detectors have a significant amount of internal scatter that degrades the accuracy of attenuation images. The scatter errors cause cupping and streaking artifacts that are practically indistinguishable from beam hardening artifacts. Residual artifacts remain after beam hardening correction and over correction increases noise in CT reconstructions. Another important limitation of existing detectors is that they have a high failure rate, especially when operating at megavolt x-ray energies even with a well collimated beam. Due to the limitations of the current detectors, we decided to design a detector specifically for high energies that has significantly reduced scatter. In collaboration with IMTEC, we have built a prototype amorphous silicon flat panel detector that has both improved imaging response and increased lifetime. LANL's contribution is the ''transparent panel concept''(patent pending), in which structures in the x-ray beam path are either eliminated or made as transparent to x-rays as practical (low atomic number and low areal density). This reduces scatter, makes attenuation measurements more accurate, improves the ability to make corrections for beam hardening, and increases signal to noise ratio in DR images and CT reconstructions. IMTEC's contribution is an improved shielding design that will increase the lifetime of the panel. Preliminary results showing the dramatic reduction in self scatter from the panel will be presented as well as the effect of this improvement on CT images.

36 MATERIALS SCIENCE↗

Fully energy-dependent HZETRN (a galactic cosmic-ray transport code)

For extended manned space missions, the radiation shielding design requires efficient and accurate cosmic-ray transport codes that can handle the physics processes in detail. The Langley Research Center galactic cosmic-ray transport code (HZETRN) is currently under development for such design use. The cross sections for the production of secondary nucleons in the existing HZETRN code are energy dependent only for nucleon collisions. The approximation of energy-independent, heavy-ion fragmentation cross section is now removed by implementing a mathematically simplified energy-dependent stepping formalism for heavy ions. The cross section at each computational grid is obtained by linear interpolation from a few tabulated data to minimize computing time. Test runs were made for galactic cosmic-ray transport through a liquid hydrogen shield and a water shield at solar minimum. The results show no appreciable change in total fluxes or computing time compared with energy-independent calculations. Differences in high LET (linear energy transfer) spectra are noted, however, because of the large variation in cross sections at the low-energy region. The high LET components are significantly higher in the new code and have important implications on biological risk estimates for heavy-ion exposure.

Shinn, Judy L.↗

Transmission of broad W/Rh and W/Al (target/filter) x-ray beams operated at 25-49 kVp through common shielding materials

Purpose: To provide transmission data for broad 25-39 kVp (kilovolt peak) W/Rh and 25-49 kVp W/Al (target/filter, W-tungsten, Rh-rhodium, and Al-aluminum) x-ray beams through common shielding materials, such as lead, concrete, gypsum wallboard, wood, steel, and plate glass. Methods: The unfiltered W-target x-ray spectra measured on a Selenia Dimensions system (Hologic Inc., Bedford, MA) set at 20-49 kVp were, respectively, filtered using 50-{mu}m Rh and 700-{mu}m Al, and were subsequently used for Monte Carlo calculations. The transmission of broad x-ray beams through shielding materials was simulated using Geant4 low energy electromagnetic physics package with photon- and electron-processes above 250 eV, including photoelectric effect, Compton scattering, and Rayleigh scattering. The calculated transmission data were fitted using Archer equation with a robust fitting algorithm. Results: The transmission of broad x-ray beams through the above-mentioned shielding materials was calculated down to about 10{sup -5} for 25-39 kVp W/Rh and 25-49 kVp W/Al. The fitted results of {alpha}, {beta}, and {gamma} in Archer equation were provided. The {alpha} values of kVp Greater-Than-Or-Slanted-Equal-To 40 were approximately consistent with those of NCRP Report No. 147. Conclusions: These data provide inputs for the shielding designs of x-ray imaging facilities with W-anode x-ray beams, such as from Selenia Dimensions.

36 MATERIALS SCIENCE↗

Shielding implications for secondary neutrons and photons produced within the patient during IMPT

Purpose: Intensity modulated proton therapy (IMPT) uses a combination of computer controlled spot scanning and spot-weight optimized planning to irradiate the tumor volume uniformly. In contrast to passive scattering systems, secondary neutrons and photons produced from inelastic proton interactions within the patient represent the major source of emitted radiation during IMPT delivery. Various published studies evaluated the shielding considerations for passive scattering systems but did not directly address secondary neutron production from IMPT and the ambient dose equivalent on surrounding occupational and nonoccupational work areas. Thus, the purpose of this study was to utilize Monte Carlo simulations to evaluate the energy and angular distributions of secondary neutrons and photons following inelastic proton interactions within a tissue-equivalent phantom for incident proton spot energies between 70 and 250 MeV.Methods: Monte Carlo simulation methods were used to calculate the ambient dose equivalent of secondary neutrons and photons produced from inelastic proton interactions in a tissue-equivalent phantom. The angular distribution of emitted neutrons and photons were scored as a function of incident proton energy throughout a spherical annulus at 1, 2, 3, 4, and 5 m from the phantom center. Appropriate dose equivalent conversion factors were applied to estimate the total ambient dose equivalent from secondary neutrons and photons.Results: A reference distance of 1 m from the center of the patient was used to evaluate the mean energy distribution of secondary neutrons and photons and the resulting ambient dose equivalent. For an incident proton spot energy of 250 MeV, the total ambient dose equivalent (3.6 Multiplication-Sign 10{sup -3} mSv per proton Gy) was greatest along the direction of the incident proton spot (0 Degree-Sign -10 Degree-Sign ) with a mean secondary neutron energy of 71.3 MeV. The dose equivalent decreased by a factor of 5 in the backward direction (170 Degree-Sign -180 Degree-Sign ) with a mean energy of 4.4 MeV. An 8 Multiplication-Sign 8 Multiplication-Sign 8 cm{sup 3} volumetric spot distribution (5 mm FWHM spot size, 4 mm spot spacing) optimized to produce a uniform dose distribution results in an ambient dose equivalent of 4.5 Multiplication-Sign 10{sup -2} mSv per proton Gy in the forward direction.Conclusions: This work evaluated the secondary neutron and photon emission due to monoenergetic proton spots between 70 and 250 MeV, incident on a tissue equivalent phantom. Example calculations were performed to estimate concrete shield thickness based upon appropriate workload and shielding design assumptions. Although lower than traditional passive scattered proton therapy systems, the ambient dose equivalent from secondary neutrons produced by the patient during IMPT can be significant relative to occupational and nonoccupational workers in the vicinity of the treatment vault. This work demonstrates that Monte Carlo simulations are useful as an initial planning tool for studying the impact of the treatment room and maze design on surrounding occupational and nonoccupational work areas.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-G-213-00: The International Electrotechnical Commission (IEC): What Is It and Why Should Medical Physicists Care?

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

Effects of High-Density Impacts on Shielding Capability

Spacecraft are shielded from micrometeoroids and orbital debris (MMOD) impacts to meet requirements for crew safety and/or mission success. In the past, orbital debris particles have been considered to be composed entirely of aluminum (medium-density material) for the purposes of MMOD shielding design and verification. Meteoroids have been considered to be low-density porous materials, with an average density of 1 g/cu cm. Recently, NASA released a new orbital debris environment model, referred to as ORDEM 3.0, that indicates orbital debris contains a substantial fraction of high-density material for which steel is used in MMOD risk assessments [Ref.1]. Similarly, an update to the meteoroid environment model is also under consideration to include a high-density component of that environment. This paper provides results of hypervelocity impact tests and hydrocode simulations on typical spacecraft MMOD shields using steel projectiles. It was found that previous ballistic limit equations (BLEs) that define the protection capability of the MMOD shields did not predict the results from the steel impact tests and hydrocode simulations (typically, the predictions from these equations were too optimistic). The ballistic limit equations required updates to more accurately represent shield protection capability from the range of densities in the orbital debris environment. Ballistic limit equations were derived from the results of the work and are provided in the paper.

Christiansen, Eric L.↗

TU-G-213-02: IEC Subcommittee 62B (Diagnostic Imaging Equipment): Recent and Active Projects

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗

TU-G-213-03: IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

The International Electrotechnical Commission (IEC) writes standards that manufacturers of electrical equipment must comply with. Medical electrical equipment, such as medical imaging, radiation therapy, and radiation dosimetry devices, fall under Technical Committee 62. Of particular interest to medical physicists are the standards developed within Subcommittees (SC) 62B, which addresses diagnostic radiological imaging equipment, and 62C, which addresses equipment for radiation therapy, nuclear medicine and dosimetry. For example, a Working Group of SC 62B is responsible for safety and quality assurance standards for CT scanners and a Working Group of SC 62C is responsible for standards that set requirements for dosimetric safety and accuracy of linacs and proton accelerators. IEC standards thus have an impact on every aspect of a medical physicist’s job, including equipment testing, shielding design, room layout, and workflow. Consequently, it is imperative that US medical physicists know about existing standards, as well as have input on those under development or undergoing revision. The structure of the IEC and current standards development work will be described in detail. The presentation will explain how US medical physicists can learn about IEC standards and contribute to their development. Learning Objectives: Learn about the structure of the IEC and the influence that IEC standards have on the design of equipment for radiology and radiation therapy. Learn about the mechanisms by which the US participates in the development and revision of standards. Understand the specific requirements of several standards having direct relevance to diagnostic and radiation therapy physicists.

60 APPLIED LIFE SCIENCES↗