Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A setup for simultaneous measurement of infrared spectra and light scattering signals: Watching amyloid fibrils grow from intact proteins

A setup for the simultaneous measurement of mid-infrared spectra and static light scattering is described that can be used for the analysis of the formation of nanoscale and microscopic aggregates from smaller molecules to biopolymers. It can be easily integrated into sample chambers of infrared spectrometers or combined with laser beams from tunable infrared lasers. Here, its use for the analysis of the formation of amyloid fibrils from intact proteins is demonstrated. The formation of amyloid fibrils or plaques from proteins is a widespread and pathogenetic relevant process, and a number of diseases are caused and correlated with the deposition of amyloid fibrils in cells and tissues. The molecular mechanisms of these transformations, however, are still unclear. We report here the simultaneous measurement of infrared spectra and static light scattering for the analysis of fibril formation from egg-white lysozyme. The transformation of the native form into non-native forms rich in β-sheet structure is measured by analysis of the amide I spectral region in the infrared spectra, which is sensitive for local structures. At the same time, light scattering signals at forward direction as well as the forward/backward ratio, which are sensitive for the number of scattering centers and their approximate sizes, respectively, are collected for the analysis of fibril growth. Thermodynamic and kinetic parameters as well as mechanistic information are deduced from the combination of the two complementary techniques.

36 MATERIALS SCIENCE↗

Design of a compact ultrahigh vacuum-compatible setup for the analysis of chemical vapor deposition processes

Optimizing thin film deposition techniques requires contamination-free transfer from the reactor into an ultrahigh vacuum (UHV) chamber for surface science analysis. A very compact, multifunctional Chemical Vapor Deposition (CVD) reactor for direct attachment to any typical UHV system for thin film analysis was designed and built. Besides compactness, fast, easy, and at the same time ultimately clean sample transfer between reactor and UHV was a major goal. It was achieved by a combination of sample manipulation parts, sample heater, and a shutter mechanism designed to fit all into a NW38 Conflat six-ways cross. The present reactor design is versatile to be employed for all commonly employed variants of CVD, including Atomic Layer Deposition. A demonstration of the functionality of the system is provided. First results of the setup (attached to an Omicron Multiprobe x-ray photoelectron spectroscopy system) on the temperature dependence of Pulsed Spray Evaporation-CVD of Ni films from Ni acetylacetonate as the precursor demonstrate the reactor performance and illustrate the importance of clean sample transfer without breaking vacuum in order to obtain unambiguous results on the quality of CVD-grown thin Ni films. The widely applicable design holds promise for future systematic studies of the fundamental processes during chemical vapor deposition or atomic layer deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute determination of photoluminescence quantum efficiency using an integrating sphere setup

An integrating sphere-based setup to obtain a quick and reliable determination of the internal quantum efficiency of strongly scattering luminescent materials is presented. In literature, two distinct but similar measurement procedures are frequently mentioned: a “two measurement” and a “three measurement” approach. Both methods are evaluated by applying the rigorous integrating sphere theory. It was found that both measurement procedures are valid. Additionally, the two methods are compared with respect to the uncertainty budget of the obtained values of the quantum efficiency. An inter-laboratory validation using the two distinct procedures was performed. The conclusions from the theoretical study were confirmed by the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A flexible experimental setup for femtosecond time-resolved broad-band ellipsometry and magneto-optics

A versatile experimental setup for femtosecond time-resolved ellipsometry and magneto-optical Kerr effect measurements in the visible light range is described. The apparatus is based on the pump-probe technique and combines a broad-band probing beam with an intense near-infrared pump. According to Fresnel scattering matrix formalism, the analysis of the reflected beam at different polarization states of the incident probe light allows one to determine the diagonal and the off-diagonal elements of the dielectric tensor in the investigated sample. Moreover, the pump-probe method permits to study the dynamics of the dielectric response after a short and intense optical excitation. The performance of the experimental apparatus is tested on CrO{sub 2} single crystals as a benchmark.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated setup for magnetic hysteresis characterization based on a voltage controlled current source with 500 kHz full power bandwidth and 10 A peak-to-peak current

This paper describes the design of a system for the characterization of magnetic hysteresis behavior in soft ferrite magnetic cores. The proposed setup can test magnetic materials exciting them with controlled arbitrary magnetic field waveforms, including the capability of providing a DC bias, in a frequency bandwidth up to 500 kHz, with voltages up to 32 V peak-to-peak, and currents up to 10 A peak-to-peak. In order to have an accurate control of the magnetic field waveform, the system is based on a voltage controlled current source. The electronic design is described focusing on closed loop feedback stabilization and passive components choice. The system has real-time hysteretic loop acquisition and visualization. The comparisons between measured hysteresis loops of sample magnetic materials and datasheet available ones are shown. Results showing frequency and thermal behavior of the hysteresis of a test sample prove the system capabilities. Moreover, the B-H loops obtained with a multiple waveforms excitation signal, including DC bias, are reported. The proposal is a low-cost and replicable solution for hysteresis characterization of magnetic materials used in power electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact electrically detected magnetic resonance setup

Electrically detected magnetic resonance (EDMR) is a commonly used technique for the study of spin-dependent transport processes in semiconductor materials and electro-optical devices. Here, we present the design and implementation of a compact setup to measure EDMR, which is based on a commercially available benchtop electron paramagnetic resonance (EPR) spectrometer. The electrical detection part uses mostly off-the-shelf electrical components and is thus highly customizable. We present a characterization and calibration procedure for the instrument that allowed us to quantitatively reproduce results obtained on a silicon-based reference sample with a “large-scale” state-of-the-art instrument. This shows that EDMR can be used in novel contexts relevant for semiconductor device fabrication like clean room environments and even glove boxes. As an application example, we present data on a class of environment-sensitive objects new to EDMR, semiconducting organic microcrystals, and discuss similarities and differences to data obtained for thin-film devices of the same molecule.

36 MATERIALS SCIENCE↗

Transparency of graphene for low-energy electrons measured in a vacuum-triode setup

Graphene, being an atomically thin conducting sheet, is a candidate material for gate electrodes in vacuum electronic devices, as it may be traversed by low-energy electrons. The transparency of graphene to electrons with energies between 2 and 40 eV has been measured by using an optimized vacuum-triode setup. The measured graphene transparency equals ∼60% in most of this energy range. Based on these results, nano-patterned sheets of graphene or of related two-dimensional materials are proposed as gate electrodes for ambipolar vacuum devices.

36 MATERIALS SCIENCE↗

X-ray pinhole camera setups used in the Atomki ECR Laboratory for plasma diagnostics

Imaging of the electron cyclotron resonance (ECR) plasmas by using CCD camera in combination with a pinhole is a non-destructive diagnostics method to record the strongly inhomogeneous spatial density distribution of the X-ray emitted by the plasma and by the chamber walls. This method can provide information on the location of the collisions between warm electrons and multiple charged ions/atoms, opening the possibility to investigate the direct effect of the ion source tuning parameters to the plasma structure. The first successful experiment with a pinhole X-ray camera was carried out in the Atomki ECR Laboratory more than 10 years ago. The goal of that experiment was to make the first ECR X-ray photos and to carry out simple studies on the effect of some setting parameters (magnetic field, extraction, disc voltage, gas mixing, etc.). Recently, intensive efforts were taken to investigate now the effect of different RF resonant modes to the plasma structure. Comparing to the 2002 experiment, this campaign used wider instrumental stock: CCD camera with a lead pinhole was placed at the injection side allowing X-ray imaging and beam extraction simultaneously. Additionally, Silicon Drift Detector (SDD) and High Purity Germanium (HPGe) detectors were installed to characterize the volumetric X-ray emission rate caused by the warm and hot electron domains. In this paper, detailed comparison study on the two X-ray camera and detector setups and also on the technical and scientific goals of the experiments is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimized setup for two-dimensional convection experiments in thin liquid films

We present a novel experimental setup to investigate two-dimensional thermal convection in a freestanding thin liquid film. Such films can be produced in a controlled way on the scale of 5–1000 nm. Our primary goal is to investigate convection patterns and the statistics of reversals in Rayleigh-Bénard convection with varying aspect ratio. Additionally, questions regarding the physics of liquid films under controlled conditions can be investigated, like surface forces, or stability under varying thermodynamical parameters. The film is suspended in a frame which can be adjusted in height and width to span an aspect ratio range of Γ = 0.16–10. The top and bottom frame elements can be set to specific temperature within T = 15 °C to 55 °C. A thickness to area ratio of approximately 10{sup 8} enables only two-dimensional fluid motion in the time scales relevant for turbulent motion. The chemical composition of the film is well-defined and optimized for film stability and reproducibility and in combination with carefully controlled ambient parameters allows the comparison to existing experimental and numerical data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact setup for the production of {sup 87}Rb |F = 2, m{sub F} = + 2〉 Bose-Einstein condensates in a hybrid trap

We present a compact experimental apparatus for Bose-Einstein condensation of {sup 87}Rb in the |F = 2, m{sub F} = + 2〉 state. A pre-cooled atomic beam of {sup 87}Rb is obtained by using an unbalanced magneto-optical trap, allowing controlled transfer of trapped atoms from the first vacuum chamber to the science chamber. Here, atoms are transferred to a hybrid trap, as produced by overlapping a magnetic quadrupole trap with a far-detuned optical trap with crossed beam configuration, where forced radiofrequency evaporation is realized. The final evaporation leading to Bose-Einstein condensation is then performed by exponentially lowering the optical trap depth. Control and stabilization systems of the optical trap beams are discussed in detail. The setup reliably produces a pure condensate in the |F = 2, m{sub F} = + 2〉 state in 50 s, which includes 33 s loading of the science magneto-optical trap and 17 s forced evaporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme ultraviolet time- and angle-resolved photoemission setup with 21.5 meV resolution using high-order harmonic generation from a turn-key Yb:KGW amplifier

Characterizing and controlling electronic properties of quantum materials require direct measurements of nonequilibrium electronic band structures over large regions of momentum space. Here, we demonstrate an experimental apparatus for time- and angle-resolved photoemission spectroscopy using high-order harmonic probe pulses generated by a robust, moderately high power (20 W) Yb:KGW amplifier with a tunable repetition rate between 50 and 150 kHz. By driving high-order harmonic generation (HHG) with the second harmonic of the fundamental 1025 nm laser pulses, we show that single-harmonic probe pulses at 21.8 eV photon energy can be effectively isolated without the use of a monochromator. The on-target photon flux can reach 5 × 1010 photons/s at 50 kHz, and the time resolution is measured to be 320 fs. The relatively long pulse duration of the Yb-driven HHG source allows us to reach an excellent energy resolution of 21.5 meV, which is achieved by suppressing the space-charge broadening using a low photon flux of 1.5 × 108 photons/s at a higher repetition rate of 150 kHz. The capabilities of the setup are demonstrated through measurements in the topological semimetal ZrSiS and the topological insulator Sb2−xGdxTe3.

Liu, Yangyang↗

Demonstration of an x-ray Raman spectroscopy setup to study warm dense carbon at the high energy density instrument of European XFEL

We present a proof-of-principle study demonstrating x-ray Raman Spectroscopy (XRS) from carbon samples at ambient conditions in conjunction with other common diagnostics to study warm dense matter, performed at the high energy density scientific instrument of the European x-ray Free Electron Laser (European XFEL). We obtain sufficient spectral resolution to identify the local structure and chemical bonding of diamond and graphite samples, using highly annealed pyrolytic graphite spectrometers. Due to the high crystal reflectivity and XFEL brightness, we obtain signal strengths that will enable accurate XRS measurements in upcoming pump–probe experiments with a high repetition-rate, where the samples will be pumped with high-power lasers. Molecular dynamics simulations based on density functional theory together with XRS simulations demonstrate the potential of this technique and show predictions for high-energy-density conditions. Our setup allows simultaneous implementation of several different diagnostic methods to reduce ambiguities in the analysis of the experimental results, which, for warm dense matter, often relies on simplifying model assumptions. The promising capabilities demonstrated here provide unprecedented insights into chemical and structural dynamics in warm dense matter states of light elements, including conditions similar to the interiors of planets, low-mass stars, and other celestial bodies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mapping the ghost free bigravity into braneworld setup

We discuss whether or not bigravity theory can be embedded into the braneworld setup. As a candidate, we consider Dvali-Gabadadze-Porrati two-brane model with the Goldberger-Wise radion stabilization. We will show that we can construct a ghost free model whose low energy spectrum is composed of a massless graviton and a massive graviton with a small mass. As is expected, the behavior of this effective theory is shown to be identical to the ghost free bigravity. Unfortunately, this correspondence breaks down at a relatively low energy due to the limitation of the adopted stabilization mechanism.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recommendations on setup in simulating atmospheric gravity waves under conventionally neutral boundary layer conditions

Wind farm-induced atmospheric gravity waves have been the subject of recent research as they can impact wind farm performance. Pressure variations associated with gravity waves can contribute to the global blockage effect and wind farm wake recovery. Therefore, accurate numerical simulation of flow fields, where wind-farm-induced gravity waves may be produced, is important. Three main considerations in such simulations are the overall domain size, the use of Rayleigh damping near domain boundaries to dampen gravity waves, and advection damping at the inlet to prevent spurious oscillations. Often these considerations are treated ad hoc rather than systematically. This work aims to test and extend the systematic modelling of internal gravity waves proposed in a preliminary investigation to modelling of both internal and trapped gravity waves. The preliminary study identifies the length scales to set the domain and damping layer sizes and the time scale to configure the Rayleigh damping coefficient but under linearly stratified conditions. Large eddy simulations of flow through a wind farm canopy are performed under conventionally neutral boundary layer (CNBL) conditions to test the validity of proposed setups for CNBL conditions. Background atmospheric parameters, such as Froude number (Fr), inversion height (H i ), and inversion layer Froude number (Fr i ) control most of the atmospheric gravity wave characteristics. We validated for CBNL conditions that the effective wavelengths of the internal gravity waves are the correct length scale to configure the domain size and damping layer thickness. Likewise, the optimum damping coefficient to dampen the internal gravity waves relates to the free atmosphere's buoyancy frequency or buoyant perturbations' time scale. We infer that the damping coefficient in the inversion layer may relate to the inversion buoyancy frequency to effectively dampen the trapped gravity waves. Moreover, the advection damping length is linked to the horizontal wavelength of the trapped gravity waves in the inversion layer to prevent spurious waves at the inlet by retaining wave energy accumulation.

17 WIND ENERGY↗

EXILL—a high-efficiency, high-resolution setup for γ-spectroscopy at an intense cold neutron beam facility

In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10 8 n s -1 cm -2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr 3 :(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 10 5 Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr 3 :(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of 133 Ba, 60 Co and 152 Eu as well as data from the reactions 27 Al(n,γ) 28 Al and 35 Cl(n,γ) 36 Cl in the energy range from 30 keV up to 10 MeV.

47 OTHER INSTRUMENTATION↗

A tilted pulse-front setup for femtosecond transient grating spectroscopy in highly non-collinear geometries

We demonstrate a tilted pulse-front transient grating (TG) technique that allows to optimally utilize time resolution as well as TG line density while probing under grazing incidence as typically done in extreme ultraviolet (EUV) or soft x-ray (SXR) experiments. Our optical setup adapts the pulse front tilt of the two pulses that create the TG to the grazing incident pulse. Here, we demonstrate the technique using all 800 nm femtosecond laser pulses for TG generation on a vanadium dioxide film. We probe that grating via diffraction of a third 800 nm pulse. The time resolution of 90 fs is an improvement by a factor of 30 compared to our previous experiments on the same system. Lastly, the scheme paves the way for EUV and SXR probing of optically induced TGs on any material.

36 MATERIALS SCIENCE↗

Fighting decoherence in a continuous two-qubit odd- or even-parity measurement with a closed-loop setup

A parity measurement on two qubits, each consisting of a single atom in a cavity, can be realized by measuring the phase shift of a probe beam which interacts sequentially with the two qubits, but imperfections lead to decoherence within the subspaces of a given parity. We demonstrate that a different setup, where the probe light interacts repeatedly with the qubits, can reduce the rate of decoherence within the odd- or the even-parity subspace significantly. We consider both the case of a resonant and the case of a nonresonant light-atom interaction and find that the performance is comparable if the parameters are chosen appropriately.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improved setup for producing slow beams of cold molecules using a rotating nozzle

Intense beams of cold and slow molecules are produced by supersonic expansion out of a rapidly rotating nozzle, as first demonstrated by M. Gupta and D. Herschbach [J. Phys. Chem. A 103, 10670 (1999); 105, 1626 (2001)]. An improved setup is presented that is able to accelerate or decelerate cold atomic and molecular beams by up to 500 m/s. Technical improvements are discussed and beam parameters are characterized by detailed analysis of time-of-flight density distributions. The possibility of combining this beam source with electrostatic fields for guiding polar molecules is demonstrated.

74 ATOMIC AND MOLECULAR PHYSICS↗