Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A combined reflectometry and quartz crystal microbalance with dissipation setup for surface interaction studies

We have developed an instrument for surface interaction studies, which combines a newly invented four detector optical reflectometry setup with quartz crystal microbalance with dissipation (QCM-D) monitoring. The design is such that data from both techniques can be obtained simultaneously on the same sensor surface, with the same signal-to-noise ratio and time resolution, as for the individual techniques. In addition, synchronized information about structural transformations, molecular mass, and the hydration of thin films on solid surfaces can be obtained on the same specimen, as validated by monitoring the formation of supported lipid bilayers on a silica-coated QCM sensor surface. We emphasize that the optical (molecular) mass can be separated from the acoustic mass including hydrodynamically coupled solvent, which means, in turn, that the amount of solvent sensed by the QCM-D technique can be dynamically resolved during adsorption processes. In addition, the advantage/necessity to use four, compared to two, detector reflectometry is emphasized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated setup for the fabrication and measurement of magnetoresistive nanoconstrictions in ultrahigh vacuum

A UHV instrument is presented for in situ fabrication of nanostructures and in situ investigation of their magnetoresistance. Nanostructures of diverse shape and size are created from thin films utilizing a focused ion beam. The magnetic nanostructures are contacted via a micromanipulator, which makes it possible to address the individual structures. The system is additionally equipped with a scanning electron microscope column, which is used for damage-free navigation and control of the structuring and contacting. First magnetoresistance measurements of structures carved into a Permalloy film demonstrate the high sensitivity and the flexibility of the new setup.

36 MATERIALS SCIENCE↗

Setup for FIR scattering on plasma crystals

We propose a new method for the investigation of plasma crystals. It is equivalent to the X-ray scattering methods of solid state physics but using far infrared (FIR) laser beams with wavelengths comparable to the Debye length of the system. This method could provide information about structure and dynamics of large 3D plasma crystals. Such crystals with up to 1 million particles have been realised in CCP discharges using micron sized Melamin-Formaledhyd (MF) particles. We present the setup of the FIR laser system, scattering arrangement, and plasma chamber. Results are discussed including video analysis of plasma crystals and FIR scattering on test samples.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tomographic Imaging of Glass/Epoxy Composite with a Laser Based Ultrasonics Setup

The present work is an attempt to augment the classical laser-based-ultrasonics setup for tomographic imaging purposes. A Glass/epoxy composite with steel insert is the test specimen and time-of-flight data has been used for tomographic reconstruction. Multiplicative algebraic reconstruction technique is used for this limited-view experiment. The resulting image is able to bring out the strong metal features.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design And Performance Of Optical Detectors Fabrication Setup Using Pulsed Laser Deposition (PLD)

PLD system was used in the preparation of nano structured thin layers to be used as optical detectors. Our home made on--axis PLD setup utilizes XeCl excimer laser (308 nm, Pulse duration of 7 ns, repetition rate of 200 Hz). The laser energy is kept at 8 mj, and the vacuum chamber has been pumped to a background pressure of 10{sup -5} mbar. The films can be grown at different substrate temperatures in the range of 25-400 deg. C. The substrate temperature was always kept below 400 deg. C by using advanced temperature control system. The target-to-substrate distance was variable from 2 to 6 cm. SiO{sub 2} was used as substrates because of its low refractive index and high transparency in the UV, visible and near infrared ranges of spectra. LIPS technique has been used for plasma diagnoses during film deposition, using a double monochromator provided with photon detector. Homogenous thin films in the order of 20-200 nm thickness were obtained. Moreover, both amorphous and crystalline thin films can be obtained by adjusting the substrate temperature, target--substrate distance, type of substrate and finally pressure of ambient gas.

36 MATERIALS SCIENCE↗

Inner-shell photoionization spectroscopy on deposited metal clusters using soft x-ray synchrotron radiation: An experimental setup

Exploration of mass-selected clusters by soft x-ray synchrotron radiation is well suited to receive element specific information on clusters in contact with a support and to systematically follow the evolution of size-dependent electronic and geometrical properties from the smallest clusters toward the bulk. Here we describe an experimental setup, which combines cluster synthesis, mass selection, soft landing, ultrahigh vacuum transfer, and photoionization experiments such as x-ray photoelectron spectroscopy, x-ray absorption, and Auger electron spectroscopy. First spectroscopic results and experimental conditions are briefly discussed for Cu{sub 19} deposited onto the natural oxide layer of a Si-wafer surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of the {sup 15}N(p,gamma){sup 16}O reaction at the LUNA accelerator with a gas target setup

The {sup 15}N(p,gamma){sup 16}O reaction links the CN cycle to the NO cycle allowing for the production of the oxygen and fluorine isotopes during the hydrogen burning in novae and AGB stars. This reaction has been intensively studied by the LUNA collaboration.In this contribution the experiment performed using a BGO detector and a windowless gas target setup is described. The measurement of the astrophysical S-factor has been done in the center of mass energy range from 90 keV to 230 keV. The cross section is found to be a factor two lower than previously believed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atmospheric pressure plasma jets beyond ground electrode as charge overflow in a dielectric barrier discharge setup

With a proper combination of applied voltage and the width of ground electrode, atmospheric pressure plasma jets extending beyond the ground electrode, whether it sits on the downstream or the upstream side, can be equally obtained with a dielectric barrier discharge setup, which can be ascribed to the overflow of deposited charges [J. Appl. Phys. 106, 013308 (2009)]. Here, we show that, by using narrower ground electrodes, such an overflow jet can be successfully launched at a much reduced voltage (down to below 10 kV). Moreover, by using transparent and triadic ground electrodes, development of charge overflow beneath the ground electrode was temporally and spatially resolved. Temporal evolution of discharge currents measured on the severed ground electrode helps establish the propagation dynamics of discharges along the dielectric surface beneath ground electrode, and also reinforces the conception that the streamer's head is in connection to the active electrode via a conducting channel. A small propagation velocity of 3.3x10{sup 3} m/s was measured for the ''overflow'' jet inside the dielectric tube. The availability of such overflow jets is enormously advantageous concerning their application to living bodies, to which the high voltage at active electrode is lethally dangerous.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Searching for spacetime granularity: analyzing a concrete experimental setup

In this work we show that the spin pendulum techniques developed by the Eoet-Wash group could be used to put very stringent bounds on the free parameters of a Lorentz invariant phenomenological model of quantum gravity. The model is briefly described as well as the experimental setup that we have in mind.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and application of setup for ac magnetic field in neutron scattering experiments

We report on a new setup developed for neutron scattering experiments in periodically alternating magnetic fields at the sample position. The assembly consisting of rf generator, amplifier, wide band transformer, and resonance circuit. It allows to generate homogeneous ac magnetic fields over a volume of a few cm{sup 3} and variable within a wide range of amplitudes and frequencies. The applicability of the device is exemplified by ac polarized neutron reflectometry (PNR): a new method established to probe remagnetization kinetics in soft ferromagnetic films. Test experiments with iron films demonstrate that the ac field within the accessible range of frequencies and amplitudes produces a dramatic effect on the PNR signal. This shows that the relevant ac field parameters generated by the device match well with the scales involved in the remagnetization processes. Other possible applications of the rf unit are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A measurement setup for acquiring the local magnetic properties of plastically deformed soft magnetic materials

This paper introduces a new measurement setup for extraction of the local magnetic properties. With the help of finite element method simulations, modifications are made on the previous double-C-yoke method. Small dimension measuring coils are applied in the stray field produced by the magnetic circuit to evaluate the local magnetic properties of the specified part of the specimen. Through the measurements with the plastically deformed materials at different temperatures, it indicates that the magnetic properties of soft magnetic materials are quite sensitive to plastic straining. After high-temperature thermal treatment on the plastically deformed specimen, the local magnetic properties exhibit an obvious recovery.

36 MATERIALS SCIENCE↗

Femtosecond broadband fluorescence upconversion spectroscopy: Improved setup and photometric correction

A setup for fluorescence upconversion spectroscopy (FLUPS) is described which has 80 fs temporal response (fwhm) for emission in the spectral range 425-750 nm. Broadband phase matching is achieved with tilted gate pulses at 1340 nm. Background from harmonics of the gate pulse is removed and sensitivity increased compared to previous designs. Photometric calibration of the upconversion process is performed with a set of fluorescent dyes. For Coumarin 153 in methanol the peak position, bandwidth, and asymmetry depending on delay time are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Online in situ x-ray diffraction setup for structural modification studies during swift heavy ion irradiation

The high energy density of electronic excitations due to the impact of swift heavy ions can induce structural modifications in materials. We present an x-ray diffractometer called ALIX (''Analyse en Ligne sur IRRSUD par diffraction de rayons X''), which has been set up at the low-energy beamline (IRRadiation SUD - IRRSUD) of the Grand Accelerateur National d'Ions Lourds facility, to allow the study of structural modification kinetics as a function of the ion fluence. The x-ray setup has been modified and optimized to enable irradiation by swift heavy ions simultaneously to x-ray pattern recording. We present the capability of ALIX to perform simultaneous irradiation-diffraction by using energy discrimination between x-rays from diffraction and from ion-target interaction. To illustrate its potential, results of sequential or simultaneous irradiation-diffraction are presented in this article to show radiation effects on the structural properties of ceramics. Phase transition kinetics have been studied during xenon ion irradiation of polycrystalline MgO and SrTiO{sub 3}. We have observed that MgO oxide is radiation-resistant to high electronic excitations, contrary to the high sensitivity of SrTiO{sub 3}, which exhibits transition from the crystalline to the amorphous state during irradiation. By interpreting the amorphization kinetics of SrTiO{sub 3}, defect overlapping models are discussed as well as latent track characteristics. Together with a transmission electron microscopy study, we conclude that a single impact model describes the phase transition mechanism.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic energy calibration algorithm for an RBS setup

This work describes a computer algorithm for automatic extraction of the energy calibration parameters from a Rutherford Back-Scattering Spectroscopy (RBS) spectrum. Parameters like the electronic gain, electronic offset and detection resolution (FWHM) of a RBS setup are usually determined using a standard sample. In our case, the standard sample comprises of a multi-elemental thin film made of a mixture of Ti-Al-Ta that is analyzed at the beginning of each run at defined beam energy. A computer program has been developed to extract automatically the calibration parameters from the spectrum of the standard sample. The code evaluates the first derivative of the energy spectrum, locates the trailing edges of the Al, Ti and Ta peaks and fits a first order polynomial for the energy-channel relation. The detection resolution is determined fitting the convolution of a pre-calculated theoretical spectrum. To test the code, data of two years have been analyzed and the results compared with the manual calculations done previously, obtaining good agreement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A versatile elevated-pressure reactor combined with an ultrahigh vacuum surface setup for efficient testing of model and powder catalysts under clean gas-phase conditions

A small-volume reaction cell for catalytic or photocatalytic testing of solid materials at pressures up to 1000 Torr has been coupled to a surface-science setup used for standard sample preparation and characterization under ultrahigh vacuum (UHV). The reactor and sample holder designs allow easy sample transfer from/to the UHV chamber, and investigation of both planar and small amounts of powder catalysts under the same conditions. The sample is heated with an infrared laser beam and its temperature is measured with a compact pyrometer. Combined in a regulation loop, this system ensures fast and accurate temperature control as well as clean heating. The reaction products are automatically sampled and analyzed by mass spectrometry and/or gas chromatography (GC). Unlike previous systems, our GC apparatus does not use a recirculation loop and allows working in clean conditions at pressures as low as 1 Torr while detecting partial pressures smaller than 10{sup −4} Torr. The efficiency and versatility of the reactor are demonstrated in the study of two catalytic systems: butadiene hydrogenation on Pd(100) and CO oxidation over an AuRh/TiO{sub 2} powder catalyst.

36 MATERIALS SCIENCE↗

LHDAC setup for high temperature and high pressure studies

A ytterbium fibre laser (λ = 1.07 μm) based laser heated diamond anvil cell (LHDAC) facility has been recently set up at HP and SRPD, BARC for simultaneous high temperature and high pressure investigation of material properties. Synthesis of GaN was carried out at pressure of ∼9 GPa and temperature of ∼1925 K in a Mao-Bell type diamond anvil cell (DAC) using the LHDAC facility. The retrieved sample has been characterized using our laboratory based micro Raman setup.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A setup for simultaneous measurement of infrared spectra and light scattering signals: Watching amyloid fibrils grow from intact proteins

A setup for the simultaneous measurement of mid-infrared spectra and static light scattering is described that can be used for the analysis of the formation of nanoscale and microscopic aggregates from smaller molecules to biopolymers. It can be easily integrated into sample chambers of infrared spectrometers or combined with laser beams from tunable infrared lasers. Here, its use for the analysis of the formation of amyloid fibrils from intact proteins is demonstrated. The formation of amyloid fibrils or plaques from proteins is a widespread and pathogenetic relevant process, and a number of diseases are caused and correlated with the deposition of amyloid fibrils in cells and tissues. The molecular mechanisms of these transformations, however, are still unclear. We report here the simultaneous measurement of infrared spectra and static light scattering for the analysis of fibril formation from egg-white lysozyme. The transformation of the native form into non-native forms rich in β-sheet structure is measured by analysis of the amide I spectral region in the infrared spectra, which is sensitive for local structures. At the same time, light scattering signals at forward direction as well as the forward/backward ratio, which are sensitive for the number of scattering centers and their approximate sizes, respectively, are collected for the analysis of fibril growth. Thermodynamic and kinetic parameters as well as mechanistic information are deduced from the combination of the two complementary techniques.

36 MATERIALS SCIENCE↗

Design of a compact ultrahigh vacuum-compatible setup for the analysis of chemical vapor deposition processes

Optimizing thin film deposition techniques requires contamination-free transfer from the reactor into an ultrahigh vacuum (UHV) chamber for surface science analysis. A very compact, multifunctional Chemical Vapor Deposition (CVD) reactor for direct attachment to any typical UHV system for thin film analysis was designed and built. Besides compactness, fast, easy, and at the same time ultimately clean sample transfer between reactor and UHV was a major goal. It was achieved by a combination of sample manipulation parts, sample heater, and a shutter mechanism designed to fit all into a NW38 Conflat six-ways cross. The present reactor design is versatile to be employed for all commonly employed variants of CVD, including Atomic Layer Deposition. A demonstration of the functionality of the system is provided. First results of the setup (attached to an Omicron Multiprobe x-ray photoelectron spectroscopy system) on the temperature dependence of Pulsed Spray Evaporation-CVD of Ni films from Ni acetylacetonate as the precursor demonstrate the reactor performance and illustrate the importance of clean sample transfer without breaking vacuum in order to obtain unambiguous results on the quality of CVD-grown thin Ni films. The widely applicable design holds promise for future systematic studies of the fundamental processes during chemical vapor deposition or atomic layer deposition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗