Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “secure operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Optimization of the Post-Operational Phase on Two Belgian Multi-Unit Nuclear Power Plants: the Case of the Non-Fissile Irradiated Core Items - 20156

The current legal framework in Belgium foresees the progressive phase out of nuclear power between October 2022 (Doel 3) and December 2025 (Doel 2). Upon its definitive shutdown, each unit of the Tihange and Doel sites will enter a Post-Operational Phase (POP) and be prepared for its Decontamination and Decommissioning (D and D). Prior to obtaining the D and D license, the Operator Electrabel is legally required to remove any non-fissile irradiated core items stored in the deactivation pools. The non-fissile irradiated core items consist essentially of control rods, poison rods and source thimbles as well as thimble plugs and foreign materials irradiated during operation: - Their significant content in highly radiant radionuclides (up to 6 TBq of Co-60 per kg of irradiated material) renders all existing operational waste management processes inadequate due to insufficient biological shielding; - Their high concentrations in long-lived radionuclides call for their disposal in a geological repository for which no final design nor waste acceptance criteria are expected prior to 2050. Uncertainties in the Belgian energy supply and security, however, require the Operator to be prepared for a partial nuclear phase out, where one or more units would benefit from lifetime extension while the remaining units would undergo decommissioning. The present paper aims at presenting how Electrabel, in partnership with Tractebel, addressed this challenge by maximizing the use of synergies within the respective sites as well as between both sites themselves, all the while accounting for site specificities. The most recent results and state of progress of the project will be detailed and the first lessons learned will be shared. The project has been split in multiple tasks and phased as follows: - An inventory phase aimed at mapping the contents, origin, composition and history of the non-fissile irradiated core items; - A pre-characterization phase based on neutron activation models; - A waste sorting phase aimed at separating waste forms for which an evacuation route exists from those for which such route does not exist; - A feasibility phase aimed at exploring all possible scenarios for the management of non-fissile irradiated core items and identifying the optimal feasible solution for each site; - A preparation phase (currently ongoing), developing further the optimal solution and ensuring that back-up solutions are available for any foreseeable change of context (licensing issue, modification in the nuclear phase-out program, etc.) and initiating early contacts with potential subcontractors for segmentation works and cask manufacturers, as well as the Belgian regulatory body and waste management agency. This phase also foresees the investigation of destructive and non-destructive radiological measurements to support the detailed characterization of the waste forms; - A realization phase (future work). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

1MV Febetron Pulse Generator Operator's Manual

The Febetron Pulse Generator (FPG) is an experimental assembly used to store electrical energy for a period of time and then release that energy over a short duration pulse to achieve high instantaneous power outputs. The FPG is an ideal device to be used for a variety high energy physics experiments. For mobility and ease of repeatable operation, the FPG is secured on a rolling test fixture and paired with a diagnostic and controls rack. The combination of the FPG, test fixture cart, SF6 gas cart, and controls rack is identified as the Pulse Generator Testing Assembly (PGTA). This document outlines all necessary information regarding the working principles, assembly/disassembly, maintenance, operation, uses, hazards, and experimental procedures of the 1 Mega Volt (MV) PGTA. This document, in addition to the manufacturer’s manuals, should be utilized as a reference whenever working with the PGTA and any of its components.

42 ENGINEERING↗

On Secured Spinning Reserve Deployment of Energy-Limited Resources Against Contingencies

Featured with fast response abilities and high ramp rates, energy storage systems (ESS), such as pumped-storage hydropower (PSH) plants and battery storage systems (BSS), are considered as key first-responders to provide spinning reserve in response to system contingencies. However, ESSs are energy-limited resources, and their sustained spinning reserve deployment is restricted by the stored energy and available capacity. Indeed, the spinning reserve deployment against contingencies may deviate actual state-of-charge (SOC) from the scheduled value, inducing potential SOC boundary violations and non-dispatchability in later hours. This paper proposes the post-contingency operation model and the spinning reserve secure constraints to address these issues. The post-contingency operation model describes that spinning reserve from ESSs is promptly deployed when contingency occurs, and then gradually substituted by quick-start units when they are switched online. By leveraging this operation strategy, spinning reserve secure constraints in terms of SOC headrooms are adopted to guarantee its deplorability. Furthermore, a modified IEEE 118-bus system with multiple PSHs and BSSs is used to verify the proposed approach.

13 HYDRO ENERGY↗

Chapter Nine - Automated Optimal Control in Energy Systems: The Reinforcement Learning Approach

With the development of smart grid technologies an increasing number of new devices and participants have joined modern energy systems and are inevitably making them more complicated and interdependent than ever. Optimally controlling such a complex energy system and maintaining its operation in a high-efficient, secure, and resilient manner are challenging tasks to the system operators. Fortunately, the revolution in deep learning and artificial intelligence (AI), both from hardware and algorithms perspectives, has provided new ideas and solutions to many previously intractable problems. As a result, this advance in computer science also sparked great research interests in utilizing AI in solving engineering problems related to the modern energy systems. Among many AI techniques, deep reinforcement learning (DRL) has demonstrated great potential for solving sequential optimization problems, which are very common in the engineering domains. Its ability to handle nonlinearity and stochasticity in controlled systems has out-competed many traditional optimal control algorithms. Therefore in this chapter, we focus on the state-of-the-art of DRL concepts and related algorithms, compare their pros and cons with traditional optimal control approaches and discuss the typical workflow for leveraging RL in solving complex problems in modern energy systems.

artificial intelligence↗

Driving Economics and Reducing Risks: The Business Case for Security-by-Design in Nuclear Power

This report provides an analysis of the financial, operational, and strategic advantages of incorporating Security-by-Design (SeBD) early in the lifecycle of nuclear power plant projects. By framing security as a foundational design element rather than a late-stage add-on, owners, vendors, and operators can reduce budget overruns, strengthen regulatory compliance, and increase revenue opportunities. The report details key lifecycle phases, highlighting the strategic imperative for organizations (including project developers, investors, vendors, and regulators) to adopt SeBD. Drawing on industry estimates, real-world case studies, and comparative cost analyses, the findings underscore that even a modest upfront investment in SeBD can yield substantial long-term returns by preventing costly retrofit activities, minimizing regulatory delays, and positioning nuclear vendors for the ability to adapt in the evolving security market. By avoiding excessive retrofit expenses and positioning security as a built-in feature rather than an afterthought, nuclear projects can protect their financial performance, enhance public trust, and secure a competitive edge in an increasingly complex global energy market. The authors advocate for SeBD’s strategic implementation, supported by established quality management methodologies, thereby promoting continuous improvement and defect avoidance. Ultimately, early SeBD integration represents a strategic investment, yielding significant returns by preventing costly retrofits and positioning nuclear projects for enhanced competitiveness and public trust.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber-Informed Engineering Guidance—Implementing CIE in Early Systems Engineering Lifecycle Stages

Traditionally, cybersecurity is not considered in the design process. Design engineers typically focus on building safety and reliability into their products and applications. Security against malicious cyber incidents is often an afterthought, resulting in deployment of security solutions during installation or operation. Unfortunately, waiting to consider cybersecurity until later in the systems engineering lifecycle often results in less effective and more expense security. Idaho National Laboratory (INL) developed the concept of Cyber-Informed Engineering (CIE) in 2015 to provide a framework that enables cybersecurity to be built into systems beginning at the conceptual design stage. In addition to ongoing research by INL, the U.S. Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response has recently developed a National CIE Strategy document for incorporating CIE into the design and operation of infrastructure systems reliant on digital monitoring or controls. This paper provides a brief review of this National CIE Strategy as well as a roadmap to historical, current, and future CIE research by INL through the U.S. DOE Office of Nuclear Energy (NE) Cybersecurity Crosscutting Technology Development Program. A near-term focus of the DOE-NE’s research and development is to extend the foundational CIE work into detailed guidance for implementation during initial systems engineering stages in nuclear digital instrumentation and control projects and to demonstrate use of the guidance in an integrated energy systems project.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation and Demonstration of the Digital Twin Certification System Remote Operations Framework

Microreactors are one promising advanced-reactor concept being pursued by the nuclear industry. They are distinguished by a relatively low power output of 20 MWth or less. These microreactors are intended for deployment in applications where conventional small-capacity power solutions, such as diesel generators, are either economically unfeasible or logistically challenging. Such applications include providing electric power and/or heat for remote communities, mining sites, defense installations, and humanitarian and disaster-relief missions. An important feature for the successful deployment of microreactors is their capability to be operated remotely. This capability can significantly reduce staffing costs by eliminating the need for licensed operators to be physically present at each reactor site. Instead, operators can be centralized in a single remote operations center placed in an economically advantageous location, thereby optimizing resources by consolidating expertise and enhancing operational efficiency. However, the implementation of a remote operation system for nuclear reactors raises new concerns regarding the security, reliability, and resilience of such a system. One way in which remote operations can be supported in a manner that maintains system security, reliability, and resilience is through the use of digital twins in a novel framework designed to verify and validate sensor data and commands communicated between the remote operations center and reactor. This framework, known as the Digital Twin Certification System (DTCS), has previously been proposed as an operations architecture that can bring security and resiliency levels of remote nuclear-reactor operations to a level acceptable for commercial deployment. This paper moves the proposed DTCS architecture from concept to reality by presenting the implementation and testing of the system. The rationale and implementation of the DTCS using tools such as DeepLynx and Apache Airflow, is covered in-depth. This is followed by a demonstration of the DTCS by applying the implemented system architecture to the Single Primary Heat Extraction and Removal Emulator, a small-scale non-nuclear test bed that emulates thermal behavior of a microreactor. The demonstration includes both normal and abnormal operating scenarios to highlight how the DTCS can increase the security, reliability, and resilience of a remote operations system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation and Demonstration of the Digital Twin Certification System Remote Operations Framework

Microreactors are one promising advanced-reactor concept being pursued by the nuclear industry. They are distinguished by a relatively low power output of 20 MWth or less. These microreactors are intended for deployment in applications where conventional small-capacity power solutions, such as diesel generators, are either economically unfeasible or logistically challenging. Such applications include providing electric power and/or heat for remote communities, mining sites, defense installations, and humanitarian and disaster-relief missions. An important feature for the successful deployment of microreactors is their capability to be operated remotely. This capability can significantly reduce staffing costs by eliminating the need for licensed operators to be physically present at each reactor site. Instead, operators can be centralized in a single remote operations center placed in an economically advantageous location, thereby optimizing resources by consolidating expertise and enhancing operational efficiency. However, the implementation of a remote operation system for nuclear reactors raises new concerns regarding the security, reliability, and resilience of such a system. One way in which remote operations can be supported in a manner that maintains system security, reliability, and resilience is through the use of digital twins in a novel framework designed to verify and validate sensor data and commands communicated between the remote operations center and reactor. This framework, known as the Digital Twin Certification System (DTCS), has previously been proposed as an operations architecture that can bring security and resiliency levels of remote nuclear-reactor operations to a level acceptable for commercial deployment. This paper moves the proposed DTCS architecture from concept to reality by presenting the implementation and testing of the system. The rationale and implementation of the DTCS using tools such as DeepLynx and Apache Airflow, is covered in-depth. This is followed by a demonstration of the DTCS by applying the implemented system architecture to the Single Primary Heat Extraction and Removal Emulator, a small-scale non-nuclear test bed that emulates thermal behavior of a microreactor. The demonstration includes both normal and abnormal operating scenarios to highlight how the DTCS can increase the security, reliability, and resilience of a remote operations system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

PUF-Based Two-Factor Authentication Protocol for Securing the Power Grid Against Insider Threat

Recent advances in smart grid technologies have enabled additional distributed control paradigms that allow more efficient and reliable operation. However, this creates new security concerns for the grid, such as attackers using spoofed grid control devices to generate false measurements. This paper introduces a two-factor authentication protocol leveraging standard public-key cryptography as one authentication factor and a hardware-based fingerprint, known as a Physical Unclonable Function, as a second authentication factor. This protocol incurs a small overhead and prevents cyber-attacks even when an adversary is able to compromise the cryptographic keys stored in the non-volatile memory of an intelligent control device.

42 ENGINEERING↗

Does practice make perfect? Lessons learned from full-scale power system incident response exercise

While threats to the energy sector occur daily, few utilities get the opportunity to fully test out their detection and response mechanisms to advanced threats in the real world. With the high demand for reliability, few grid operators would allow execution of simulated cyber-attacks on their live systems. The DOE-funded Liberty Eclipse project offers a unique opportunity for small and large utilities and coops to practice their combined IT/OT responses to a live red team executing attacks against an isolated power system on an island in New York. Both cyber teams and power operations teams must work together to detect and respond to attacks, even restoring the power system against extreme impacts. Lessons learned from these exercises reveal key takeaways for understanding what a real attack against the electric sector will look like, gaps in execution of the best-laid plans when the pressure of a real event is bearing down, and how organizations can better prepare for advanced attacks by optimizing participation in exercises. This presentation will discuss successes and opportunities for improvement both in how utilities can prepare for and respond to events, as well as how full-scale IT/OT exercises can be coordinated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LLNL Kimberlina 1.2 NUFT Simulations June 2018 (v2)

This dataset contains the output 6,000, 3-dimensional reactive multi-phase flow and transport aquifer simulations of brine and CO2 leakage into a protective aquiver in California’s San Joaquin Valley and input data files detailing the geologic mesh, aquifer physical properties and CO2 and brine injection rates. This data set was generated as an ongoing effort with the US DOE National Risk Assessment Partnership (NRAP) to evaluate the effectiveness of monitoring techniques to detect brine and CO2 leakage from legacy wells into underground sources of drinking water overlaying a CO2 storage reservoir. Each simulation contains a unique set of input parameters, generated stochastically. The outputs consist of these upper three geologic layers (from top): the Etchegoin, Macoma-Chanac, Santa Margarita-McLure formations. These simulations span the several distances (1, 3 and 6 km or wells W31-0.2, W31-0.5 and W31-1.0, respectively) from the CO2 injector, initiated from bottom hole pressure and saturation to calculate wellbore leakage from the storage reservoir, with low and high regional groundwater gradients and wellbore leakage into 5 leaky nodes. The dataset includes 1,000 unique simulations for each distance, which each contain a unique aquifer heterogeneity, aquifer and caprock permeability, and two model generations are included with a high permeability (prod07) and hybrid permeability (prod09). The range of permeability distributions is listed in Table 1. Each model generation consists of 3,000 simulations. Included in the dataset are the leakage rates determined from 2D wellbore models which utilize the pressure and CO2 saturation from LBL's reservoir simulations, NUFT mesh files with distributed lithology, NUFT rocktab files which describe the material properties for the geologic layers and the NUFT input files and post-processed output 'ntab' files. Each ntab file contains spatial (rows) and temporal (columns) model output tables for each model cell, the locations (x,y,z) and dimensions for each cells (dx, dy, dz). Table 1. Permeability distribution ranges for prod07 and prod09 model generations Geologic Layer: Permeability Range (log10 m^2) prod07 prod09 Etchegoin -12.92 to -10.92 -13.70 to -11.44 Macoma-Chanac -12.72 to -10.72 -13.50 to -11.24 Santa Margarita-McLure -12.70 to -10.70 -13.48 to -11.22 The input files used to generate the model include which are included in the dataset are: Time series of CO2 leakage input into the model (ex: Q_brn.W31-0.2.sim1000.layers123.tab) Time series of CO2 leakage input into the model (ex: Q_CO2.W31-0.2.sim1000.layers123.tab) Physical properties of the aquifer materials detailing the aquifer porosity, solid density, partitioning coefficients, permeabilities and van-Genuchten parameters detailed in a NUFT rocktab file: (ex: sim1000.usnt.rocktab) Numerical mesh and geologic data assigned to each model cell detailed in a NUFT genmsh format (ex: sim1000.mesh_k16.prod07.trans.genmsh) The primary output parameters are: pH (use absolute value) Change in TDS (mg/kg) Change in Pressure (Pa) Change CO2 gas saturation (fraction range 0.0-1.0) for example, the directory /p/lscratchh/mansoor1/nrap/kimberlina/prod09/mainfiles/sim1000/W31- 0.2 contains: sim1000.W31-0.2.trans.pH.red.ntab sim1000.W31-0.2.no_bg.trans.TDS.red.ntab sim1000.W31-0.2.usnt.P.deltabg.red.ntab sim1000.W31-0.2.usnt.CO2_sat.deltabg.red.ntab Each row in the NTAB files consist of model output per numerical grid cell. Each output file contains 33 columns (variables), including the information of numerical records, geologic location and sizes and the simulated parameter values over time. The first 13 variables are about numerical records and relative geologic information for a simulation grid: 1. index: simulation index 2. i: the ith grid of x-axis 3. j: the ith grid of y-axis 4. k: the ith grid of z-axis 5. element_ref: element reference 6. nuft_ind: nuft index 7. x: grid location in the x axis direction 8. y: grid location in the y axis direction 9. z: grid location in the z axis direction 10. dx: grid length in the x axis direction 11. dy: grid length in the y axis direction 12. dz: grid length in the z axis direction 13. volume: volume of the simulation grid The remainder (14, 15, 16...) variables are the simulated parameter values over time, take Pressure as an example, are: 14. 0.0y: initial pressure per cell. 15. 10.0y: simulated pressure at the end of the 10th year. 16. 20.0y: simulated pressure at the end of the 20th year. ... (repeated for every 10 years until 200 years)... The model extends 10,000 m, 5,000 m and 1,411 m in the x,y and z dimensions, respectively. The mesh consists of 164,832 cells with mesh dimensions of 101 x 51 x 32 (nx, ny, nz), with cell dimensions ranging from 100 m laterally (along x and y-axis) and model layers are as designated in the z-axis: Layer 1: atmosphere (1e-30 m thick) Layer 2: upper caprock (10 m thick) Layers 3-13: Etchegoin (536.23 m thck) Layers 14-27: Macoma-Chanac (679.04 m thick) Layers 28-32: Santa Margarita-McLure (185.94 m thick) The wellbore is placed along node i=51, j=26, and extends vertically along 5 nodes from the top to the bottom of the model. Special instructions when extracting files: Each Gzip archive (ex: prod07.sim1000-sim00099.tar.gz) contains 100 simulations. Gzip archives should be transferred into base directories (ie. In Linux: mkdir prod07; mv prod07.*.tar.gz prod07/.) before extracting, or files will be overwritten. Each sub-simulation tree should have the following file structure pattern (using the linux 'tree' command): |-- prod07 | |-- sim0001 | |-- W31-0.2 | | |-- Q_brn.W31-0.2.sim0001.layers123.tab | | |-- Q_co2.W31-0.2.sim0001.layers123.tab | | |-- sim0001.W31-0.2.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-0.2.trans.pH.red.ntab | | |-- sim0001.W31-0.2.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-0.2.usnt.P.deltabg.red.ntab | |-- W31-0.5 | | |-- Q_brn.W31-0.5.sim0001.layers123.tab | | |-- Q_co2.W31-0.5.sim0001.layers123.tab | | |-- sim0001.W31-0.5.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-0.5.trans.pH.red.ntab | | |-- sim0001.W31-0.5.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-0.5.usnt.P.deltabg.red.ntab | |-- W31-1.0 | | |-- Q_brn.W31-1.0.sim0001.layers123.tab | | |-- Q_co2.W31-1.0.sim0001.layers123.tab | | |-- sim0001.W31-1.0.no_bg.trans.TDS.red.ntab | | |-- sim0001.W31-1.0.trans.pH.red.ntab | | |-- sim0001.W31-1.0.usnt.CO2_sat.deltabg.red.ntab | | |-- sim0001.W31-1.0.usnt.P.deltabg.red.ntab | |-- sim0001.mesh_k16.prod07.trans.genmsh Disclaimer This document was prepared as an account of work sponsored by an agency of the United States government. Neither the United States government nor Lawrence Livermore National Security, LLC, nor any of their employees makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or Lawrence Livermore National Security, LLC. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or Lawrence Livermore National Security, LLC, and shall not be used for advertising or product endorsement purposes. Lawrence Livermore National Laboratory is operated by Lawrence Livermore National Security, LLC, for the U.S. Department of Energy, National Nuclear Security Administration under Contract DE-AC52-07NA27344. This report was reviewed and released as LLNL-MI-753464.

aquifer↗

Enhancing Cloud Cybersecurity: Prescriptive Controls for Operational Technology

This whitepaper provides strategic insights and recommendations into security cloud-based solutions for electric utilities, encompassing operational technology (OT), virtual power plants (VPP), distributed energy resources (DERs), applications, networks, and data storage as they transition to and leverage cloud infrastructure through managed service providers (MSPs) and cloud service providers (CSPs). Principles derived from established frameworks serve as a foundation for best practices across cybersecurity projects and remove the constraints of settling on a single framework. For organizations that prefer not to integrate a specific framework altogether, elements of the proposed approach could be adopted or tailored to best fit defined requirements and expected functionalities. The Cirrus assessment, a utility cloud feasibility tool, and the roadmap it provides serve as a precursor to this paper, which seeks to be a valuable resource for defining next steps following cloud technology integration feasibility appraisal. With its comprehensive approach to adoption, the Cirrus framework offers strategic guidance on responsibly preparing for or deploying a utility cloud solution. The previously published whitepaper, “Use Case-Informed Framework for Utility Cloud Migration,” details the guiding strategy, research, and deployment of cloud solutions within electric and interconnected grid systems. Before implementing the controls suggested in this document, it is recommended that stakeholders complete Cirrus's cloud integration assessment and pair the results with their unique cybersecurity controls to form a comprehensive cloud-based utility cybersecurity plan. The Cirrus outcome will consider a series of future architectures for the grid before and after the energy transition and evaluate the arguments for and against cloud applications for each electric and interconnected grid layer. This document is a companion to the original whitepaper, "Use Case-Informed Framework for Utility Cloud Migration" to further identify and recommend security controls based on Cirrus’s cloud integration assessment output. The following whitepaper outlines the cybersecurity controls that secure cloud-service models pertinent to the electric sector using the predefined categories identify, protect, detect, and respond and recover. The objective is to outline prescriptive security controls based on the type of architecture and data stored in the cloud. The focus includes dissecting the shared responsibility model and elucidating what on-premises Infrastructure as a Service (IaaS), Platform as a Service (PaaS), and Software as a Service (SaaS) entail. A pivotal consideration in this context is allocating responsibility for foundational cybersecurity aspects—having used Cirrus for the cloud integration assessment. The ensuing controls detailed herein also represent a checklist of controls necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and strategic foresight in a safe and responsible manner.

42 ENGINEERING↗

1. Physical Security Engineering by Design for Nuclear Facilities; 2. Nuclear Power Plant Site Security Management – A Security Strategy; 3. The UAE Women in Nuclear Energy Security

1. Security by design, or SeBD, is a comprehensive approach that integrates the physical protection system of a nuclear plant into every stage of its existence. This includes planning, designing, constructing, commissioning, and operating the facility, using a combination of analytical, physical, technological, and procedural measures. Essentially, SeBD involves intentionally applying and incorporating security into all aspects of design and operation throughout the entire lifecycle of a facility. By implementing this methodology throughout various phases such as program development, process implementation, staff training and procedures management in conjunction with plant equipment, facilities can be optimized to minimize security risks without compromising functional design requirements. This ultimately improves the overall security posture of the site and reduces the need for costly modifications or additional security resources post-design. 2. A site security strategy is a living document that is revised on a periodic or event-driven basis, ensuring that site security operations and corresponding procedures provide long-term, effective protection for the entire nuclear power plant (NPP) site. A site security strategy aims to mitigate threats across the entire NPP site via in-depth defense approaches and mutual support; therefore, if a layer is omitted or altered, then the effect across all layers must be re-evaluated. Therefore, the aim of the site security strategy is to provide an appropriate, scalable security regime that deters, denies, delays, and detects incidents and, equally importantly, reassures legitimate users and the regulator that due diligence and regulatory compliance have been achieved, ensuring that the site is safe and secure. Robust access control for vehicles and pedestrians is at the heart of the strategy. Vehicle and pedestrian searching and screening are seen as the strongest mitigation methods against vehicle- and pedestrian-borne attacks. The security strategy must also be supported through comprehensive staff training and the development of robust processes, procedures, and planning. If all these measures are to be effective, then training must be implemented during each phase of construction, partial operation/commissioning, and full operation. No single element of site security is completely isolated from the influence of other elements. Ideally, consideration of all key elements will result in a security strategy that is integrated and proportional to the threat and that does not over specify individual security solutions through the application of isolated measures but rather applies a holistic, all-encompassing approach. 3. When women enter the labor force, numerous positive outcomes emerge, including increased GDP, educational gains, and decreased maternal mortality. Despite these benefits, women's employment rates and equality vary significantly worldwide as does support for women in the workforce. This paper will explore the multifaceted benefits of women's employment, the factors influencing labor force participation rates, and the urgency to achieve gender equality as outlined in the 2015 United Nations Sustainable Development Goals (SDGs). It will then examine the emerging presence of women in the traditionally male-dominated nuclear field, specifically within the United Arab Emirates (UAE) as a testament to their resilience and determination to break social norms and advance gender equality.

Zineddin, Dr. Z.↗

Operational Forecasting of Induced Seismicity (CRADA Final Report)

This was a collaborative effort between Lawrence Livermore National Security, LLC ("LLNS"), as manager and operator of Lawrence Livermore National Laboratory ("LLNL"), The Regents of the University of California, as manager and operator of Lawrence Berkeley National Laboratory (Collectively, Contractors) and Nanometrics, Inc. ("Participant"), to develop a toolkit called "Operational Forecasting of Induced Seismicity (ORION)" that includes a decision tree method for operational forecasting of induced seismicity rates related to fluid disposal operations.

58 GEOSCIENCES↗

National Criticality Experiments Research Center (NCERC) - capabilities and recent measurements

The National Criticality Experiments Research Center (NCERC) located at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS) and operated by Los Alamos National Laboratory (LANL) is home to four critical assemblies which are used to support of range of missions, including nuclear criticality safety and nuclear nonproliferation. Additionally, subcritical systems can also be assembled at NCERC. NCERC is providing critical and subcritical experiments valuable to the nuclear data community and experiments performed at NCERC are often published as benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. This manuscript will give a broad overview of recent experiments performed at NCERC, upcoming experiments, and why integral measurements are important and useful to the nuclear data community. The four critical assemblies are GODIVA IV, FLATTOP, COMET, and PLANET. GODIVA IV is a cylindrical metal fast burst reactor, the fourth in the GODIVA series that dates back to the 1950’s. FLATTOP is an highly enriched uranium (HEU) or Pu core reflected by natural uranium. COMET and PLANET are vertical lift assemblies, where one half of the reactor can be lifted to the upper half of the reactor to create a critical system. Some recent experiments include various critical intermediate energy assemblies with lead, and subcritical measurements of plutonium reflected by copper, tungsten, and nickel. Work is also underway to make a better measurement of the critical mass of neptunium, using a neptunium sphere surrounded by nickel shells. Additionally, measurements will be performed next year with HEU shells from Rocky Flats. These HEU shells will be stacked together to make larger systems, allowing for a large range of criticality (from subcritical to delayed critical). Other upcoming measurements include an HEU critical assembly sensitive to intermediate energy neutrons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.

Giraldo, Jairo↗

Efficient Clustering of Software Vulnerabilities using Self Organizing Map (SOM)

The common vulnerabilities and exposures (CVE) database was created with a mission to ``identify, define, and catalog publicly disclosed cybersecurity vulnerabilities''. This rich body of information can be used to enable rapid and efficient response to secure and defend cyber operations and protect critical cyber infrastructure. The main goal of this paper is to develop a visual analytics tool to enable deep analysis of CVEs using unsupervised clustering techniques. We enhance our analysis by first mapping CVEs to hierarchical-classes in Common Weakness Enumeration (CWE) using information in the National Vulnerability Database (NVD). Both the mapping and the numerical representation of CVEs are enabled by V2W-BERT, which uses natural language processing of the extensive information in NVD to generate a large tabular database of 137,226 CVE entries from 1999 to 2020, where each CVE is represented by a vector of 768 numerical features. The vectorized data is processed by Self-Organizing Maps (SOM), which is an unsupervised machine learning technique for dimensionality reduction, visual representation and clustering. Using a Torus map of 6417 units, we achieve ~10-fold data compression of ~140k CVEs using SOM. The trained map is further clustered using standard K-means clustering into 138 clusters of CVEs. We conducted a brief investigation of the rich mapping of CVEs to best-matching-units to K-means clusters, as well as CVEs to CWEs. For example, this novel mapping provided insight into the role of CWE-59 and CWE-264 in several CVEs that is otherwise hard to explore in the original data. We conclude that our this novel approach will not only enable deep analysis of the complex relationships between CVEs and CWEs, but also a mechanism to quickly respond to and design mitigation actions for rapidly evolving vulnerabilities that have not been mapped to existing CWEs.

Panchal, Khyati↗