Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

TRISO PARTICLE FUEL POLISHING PROCESS COMPARISON

The investigation of the TRISO coated particles is important in terms of verification the quality of the nuclear fuel samples before placing them in the reactor core. To determine the degree of damage to the coated particles, the samples must be properly polished in order to uncover the inner layers. The poster presents a comparison of two polishing methods. Mechanical polishing method, which is used frequently for sample preparations generates additional mechanical damages in the studied fuel particle, thus directly affecting the experimental results. Due to that, a novel way to polish the samples is presented - an ionic polishing method. Based on the obtained results, it was concluded that the ion polishing method is better because the level of interference with the structures of the individual layers of the tested samples is much lower than with the mechanical method.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗

Oxygen Adsorption, Subsurface Oxygen Layer Formation and Reaction with Hydrogen on Surfaces of a Pt–Rh Alloy Nanocrystal

The oxygen adsorption and its catalytic reaction with hydrogen on Pt–Rh single crystals were studied at the nanoscale by Field Emission Microscopy (FEM) and Field Ion Microscopy (FIM) techniques at 700 K. Both FEM and FIM use samples prepared as sharp tips, apexes of which mimic a single nanoparticle of catalyst considering their similar size and morphology. Oxygen adsorption on Pt-17.4 at.%Rh samples leads to the formation of subsurface oxygen, which is manifested in the field emission (FE) patterns: for O2 exposure of ~3 Langmuir (L), {113} planes appear bright in the emission pattern, while for higher oxygen doses, i.e. 84 L, the bright regions correspond to the high index planes between the {012} and {011} planes. Formation of subsurface oxygen is probably accompanied by a surface reconstruction of the nanocrystal. The subsurface oxygen can be effectively reacted off by subsequent exposure of the sample to hydrogen gas at 700 K. The hydrogenation reaction was observed as a sudden, eruptive change of the brightness seen on the FE pattern. This reaction resulted in the recovery of the initial field emission pattern characteristic of a clean tip, with {012} facets being the most visible. It was shown that the oxygen accumulation-reduction process is completely reversible. The obtained results indicate that the presence of subsurface species must be considered in the description of reactive processes on Pt–Rh catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO 2 –Brine Contact Angle Measurements on Navajo, Nugget, Bentheimer, Bandera Brown, Berea, and Mt. Simon Sandstones

In this study, contact angles were measured for CO 2 bubbles on six different sandstones (Navajo, Nugget, Bentheimer, Bandera Brown, Berea, and Mt. Simon) that could potentially represent properties of CO 2 storage depositional environments. The impacts of pressure and temperature were studied by focusing on the CO 2 phase behavior in three different scenarios: gaseous, liquid, and supercritical conditions. Despite controlling the sample preparation and cleanliness, CO 2 -brine equilibration conditions, and pressure and temperature, there were inconsistencies in contact angle trends that could largely be attributed to natural sample heterogeneity resulting from localized variations in topography, surface roughness, and mineral composition across the surface. Despite these variations, the analysis of 298 measurements from this study showed that 81% of the contact angles were below 40° representing strongly water-wet to (moderately) water-wet behaviors. Also, 17.3% of the measurements were between 40° and 60° (weakly water-wet) and primarily belonged to small CO 2 bubbles (< 500 μm) that were heavily impacted by localized surface heterogeneity in natural sandstone samples. Additionally, only 1.7% of the measurements had angles greater than 60° and could be classified as CO 2 -wet behavior, but these measurements occurred on extremely small bubbles (100-200 μm) that were very dependent on localized surface heterogeneity. While some of the detailed physics of the CO 2 -brine-sandstone interface is still poorly understood, from an application standpoint, the sandstones of this study were best characterized as strongly water-wet to (moderately) water-wet.

03 NATURAL GAS↗

High-fidelity and high-resolution phase mapping of granites via confocal Raman imaging

Abstract In physical sciences such as chemistry and earth sciences, specifically for characterization of minerals in a rock, automated, objective mapping methods based on elemental analysis have replaced traditional optical petrography. However, mineral phase maps obtained from these newer approaches rely on conversion of elemental compositions to mineralogical compositions and thus cannot distinguish mineral polymorphs. Secondly, these techniques often require laborious sample preparations such as sectioning, polishing, and coating which are time-consuming. Here, we develop a new Raman imaging protocol that is capable of mapping unpolished samples with an auto-focusing Z-mapping feature that allows direct fingerprinting of different polymorphs. Specifically, we report a new methodology for generating high fidelity phase maps by exploiting characteristic peak intensity ratios which can be extended to any multi-phase, heterogenous system. Collectively, these enhancements allow us to rapidly map an unpolished granite specimen (~ 2 × 2 mm) with an exceptionally high accuracy (> 97%) and an extremely fine spatial resolution (< 0.3–2 µm).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-Ray Fingerprinting Techniques for Recognizing A Hydrological Role in the Formation of Minerals on the Surface of Mars

Previous work has demonstrated the ability of a miniaturized XRD-XRF instrument to perform in-situ analyses without sample preparation or acquisition. Deployment of this instrument on a Martian rover will allow a large number of rapid qualitative analyses, which will maximize the diversity of samples studied and selected for possible return. As a first step in designing a decision tree for recognizing minerals in complex mixtures, d spacings were plotted against intensity for several mineral groups comprising rock and soil types inferred for the surface of Mars (weathered basalt, playa and hydrothermal deposits, clay-rich soils). In all groups, d spacings cluster in a range from about 1-4 angstroms, which can under certain circumstances obscure patterns for individual phases. However, within the silicate family, minerals containing either bound OH- or molecules of H20 (clays, micas, amphiboles, zeolites) are characterized by a shift of peaks to higher d spacings. Large d spacings (greater than about 7 angstroms) thus act as a first-order filter for distinguishing hydrous from anhydrous silicates. The ability to quickly verify the presence of silicates that have interacted with water has important implications for using mineral chemistry and structure to help decipher the hydrologic and atmospheric history of Mars. This represents a beginning for developing more sophisticated methods of pattern recognition. These will combine XRD and XRF analyses with optical data to rapidly7 discern environmentally diagnostic assemblages without the necessity of identifying every peak individual mineral phase.

Metzger, Ellen P.↗

A Boosted Critical Temperature of 166 K in Superconducting D 3 S Synthesized from Elemental Sulfur and Hydrogen

The discovery of superconductivity in H 3 S at 203 K marked an advance towards room-temperature superconductivity and demonstrated the potential of H-dominated compounds to possess a high critical temperature (T c ). There have been numerous reports of the H-S system over the last five years, but important questions remain unanswered. It is crucial to verify whether the Tc was determined correctly for samples prepared from compressed H 2 S, since they are inevitably contaminated with H-depleted byproducts. Here, we prepare stoichiometric H 3 S by direct in situ synthesis from elemental S and excess H 2 . The Im$_\bar{3}$ m phase of D 3 S samples exhibits a T c significantly higher than previously reported values (ca. 150 K), reaching a maximum T c of 166 K at 157 GPa. Furthermore, we confirm that the sharp decrease in T c below 150 GPa is accompanied by continuous rhombohedral structural distortions and demonstrate that the Cccm phase is nonmetallic, with molecular H 2 units in the crystal structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of Silicon in Hydrazine

Inductively coupled plasma-mass spectrometry (ICP-MS) is a highly sensitive technique sometimes used for the trace determination of silicon at a mass-to-charge (m/z) ratio of 28, the most abundant natural isotope of silicon. Unfortunately, ICP-MS is unable to differentiate between other sources of m/z 28 and false positive results for silicon will result when other sources of m/z 28 are present. Nitrogen was a major source of m/z 28 and contributes to the m/z 28 signal when hydrazine sample or nitric acid preservative is introduced into the plasma. Accordingly, this work was performed to develop a sample preparation step coupled with an ICP-MS analysis that minimized non-silicon sources of m/z 28. In the preparatory step of this method, the hydrazine sample was first decomposed predominately to nitrogen gas and water with copper-catalyzed hydrogen peroxide. In the analysis step, ICP-MS was used without nitric acid preservative in samples or standards. Glass, a potential source of silicon contamination, was also avoided where possible. The method was sensitive, accurate, and reliable for the determination of silicon in monopropellant grade hydrazine (MPH) in AF-E-332 elastomer leaching tests. Results for silicon in MPH were comparable to those reported in the literature for other studies.

McClure, Mark B.↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

Nanometer Scale Imaging to Develop Quantitative Descriptors of Bipolar Membrane Junction Structure

Swings in pH can be achieved by electrically polarizing a bipolar membrane (BPM) to drive water dissociation at the BPM junction for electrochemical conversion and separation processes. BPM junction design is critical to tailor performance for specific applications; however, characterization techniques capable of resolving the nanometer scale physical structure of the junction are limited. We present sample preparation, imaging, and analysis workflows that are adaptable to a variety of BPM junction architectures. Atomic force microscopy produces BPM junction images with nanometer scale lateral resolution for samples with and without a graphene oxide water dissociation catalyst in the junction. Subsequent image segmentation and analysis quantify line edge roughness and catalyst layer thickness as descriptors of junction structure. Comparison of pre- and post-electrodialysis junctions suggests electric field-induced alignment of catalyst particles during electrodialysis. This characterization workflow can inform manufacturing protocols, computational modeling, and failure mode analysis for next-generation BPMs.

97 MATHEMATICS AND COMPUTING↗

Characterization of actinide abundances and isotopic compositions by HR-ICP-MS

In this report, we present actinide isotopic and elemental data from fallout melt glass using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). This is an analytical technique that requires minimal sample preparation. These data are directly compared to the results of high precision isotopic analyses and elemental assay by multi-collector (MC-) ICP-MS, which requires lengthy sample processing involving spiking and purifying aliquots of individual elements. The comparison shows broad overlap between the results of the two techniques. Thus, although the data obtained by HR-ICP-MS is of significantly lower precision, it is a viable method to obtain actinide elemental and isotopic data on a more rapid timeframe than traditional high-precision techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COMPAS: Compositional mineralogy with a photoacoustic spectrometer

There is an important need for an in situ method of mineral and rock identification and quantification that provides true absorption spectra for a wide spectral range for lunar lander/rover missions. Many common minerals such as feldspars, magnetite, ilmenite, and amorphous fine solids or glasses, can exhibit flat spectral reflectances in the 400-2500 nm spectral region that render inaccurate or difficult their spectral detection and quantitative analysis. Ideal rock and mineral spectra are, of course, pure absorption spectra that are independent of the spectral effects of scattering, particle size, and distribution that can result in a suppression or distortion of their spectral features. This ideal seldom pertains to real samples. Since sample preparation is difficult and may fundamentally alter the observed diffuse spectral reflectance, an in situ spectral measurement method for rocks and minerals on the Moon, insensitive to the sample morphology, would be invaluable. Photoacoustic spectroscopy is a well-established technique appropriate for this task that has been widely applied in condensed-phase spectral studies of complex, highly light scattering, unprepared samples of everything from coal to whole blood, including rock and mineral characterization. A Compositional Mineralogy Photoacoustic Spectrometer, or COMPAS, can enable in situ spectral measurement of rocks and minerals, bypassing the major limitations of diffuse reflectance spectroscopy. COMPAS spectral capabilities for rock and mineral samples will be incorporated into an instrument prototype specifically for lunar measurements, compatible with rover capabilities.

Smith, W. Hayden↗

Constraints on Exposure Ages of Lunar and Asteroidal Regolith Particles

Mineral grains in lunar and asteroidal regolith samples provide a unique record of their interaction with the space environment. Exposure to the solar wind results in implantation effects that are preserved in the rims of grains (typically the outermost 100 nm), while impact processes result in the accumulation of vapor-deposited elements, impact melts and adhering grains on particle surfaces. These processes are collectively referred to as space weathering. A critical element in the study of these processes is to determine the rate at which these effects accumulate in the grains during their space exposure. For small particulate samples, one can use the density of solar flare particle tracks to infer the length of time the particle was at the regolith surface (i.e., its exposure age). We have developed a new technique that enables more accurate determination of solar flare particle track densities in mineral grains <50 micron in size that utilizes focused ion beam (FIB) sample preparation combined with transmission electron microscopy (TEM) imaging. We have applied this technique to lunar soil grains from the Apollo 16 site (soil 64501) and most recently to samples from asteroid 25143 Itokawa returned by the Hayabusa mission. Our preliminary results show that the Hayabusa grains have shorter exposure ages compared to typical lunar soil grains. We will use these techniques to re-examine the track density-exposure age calibration from lunar samples reported by Blanford et al. (1975).

Berger, Eve L.↗

Nanometer-Scale Imaging of Inhomogeneous Active Charge Carriers in Arsenic-Doped CdTe Thin Films

We report nanometer-scale imaging of active carrier distribution of As-doped CdTe films by scanning capacitance microscopy (SCM). We developed SCM sample preparation for CdTe by ion-milling followed by thermal processing. The nanometer-resolution carrier delineation for CdTe was validated by imaging on a CdTe cross-section sample made by a molecular beam epitaxy layer stack with As-doping concentrations of 10^15 ~10^18 /cm 3 . We found that the carrier distribution in As-doped films was significantly nonuniform, with inhomogeneity ranging from sub-um to a few um and concentration variation of one order of magnitude (low 10^16 to low 10^17 /cm 3 ). This nonuniformity is distributed randomly, independent of grain structure and grain boundary (GB). We used Kelvin probe force microscopy (KPFM) and cathodoluminescence (CL) to further map the surface potential and radiative illumination on the same area as the SCM image. Higher potential and lower CL intensity were found on GBs but not on SCM contrast, illustrating positive GB charging and GB recombination but not GB-distinguished doping. The overall KPFM potential image is in rough agreement with the SCM carrier distribution, in terms of Fermi-level position relative to the bandgap edge - thus resulting in the band-edge potential fluctuation. Nonuniform carrier concentration, potential fluctuation, and defect recombination can all together cause the Voc deficit of the As-doped CdTe device.

14 SOLAR ENERGY↗

Ultra-high SERS detection of consumable coloring agents using plasmonic gold nanostars with high aspect-ratio spikes

Solution-based SERS detection by using a portable Raman instrument has emerged as an important tool due to its simplicity, and flexibility for rapid and on-site screening of analyte molecules. However, this method has several shortcomings, including poor sensitivity especially for weak-affinity analyte molecules, where there is no close contact between the plasmonic metal surface and analyte molecule. Examples of weak-affinity molecules include pigment molecules that are commonly used as a consumable coloring agent, such as allura red (AR), and sunset yellow (SY). As high consumption of colorant agents has been shown to cause adverse effects on human health, there is a strong need to develop a simple and practical sensing system with high sensitivity for these agents. Here we present a novel, highly sensitive solution-based SERS detection method for AR, and SY by using CTAC capped gold nanostars (GNS) having different aspect ratios (GNS-2, GNS-4, and GNS-5) without utilizing any aggregating agents which can enhance SERS signal however it reduces batch to batch reproducibility. The influence of the aspect ratio of GNS on SERS properties was investigated. We have achieved a limit of detection (LOD) of AR and SY as low as 0.5 and 1 ppb, respectively by using GNS-5 with the advantages of minimal sample preparation by just mixing the analyte solution into a well plate containing GNS solution. In addition, excellent colloidal stability and reproducibility have further enhanced the applicability in real-world samples. Altogether, our results evidence that the solution-based SERS detection platform using high aspect-ratio GNS can be applied for practical application to detect pigment molecules in real samples with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Routine Beryllium-10 analysis from post-detonation debris and geologic materials [Slides]

Beryllium (Be) isotope measurements provide insight into weapon design, yield, etc. Sample preparation nor measurement capability currently existed at LANL. Potential capability directly benefits nuclear forensics venture. PI Goehring has nearly 20 years of Be chemistry experience, including method implementation with difficult samples.

07 ISOTOPE AND RADIATION SOURCES↗

An optimized approach and inflation media for obtaining complimentary mass spectrometry-based omics data from human lung tissue

Human disease states are biomolecularly multifaceted and can span across phenotypic states, therefore it is important to understand diseases on all levels, across cell types, and within and across microanatomical tissue compartments. To obtain an accurate and representative view of the molecular landscape within human lungs, this fragile tissue must be inflated and embedded to maintain spatial fidelity of the location of molecules and minimize molecular degradation for molecular imaging experiments. Here, we evaluated agarose inflation and carboxymethyl cellulose embedding media and determined effective tissue preparation protocols for performing bulk and spatial mass spectrometry-based omics measurements. Mass spectrometry imaging methods were optimized to boost the number of annotatable molecules in agarose inflated lung samples. This optimized protocol permitted the observation of unique lipid distributions within several airway regions in the lung tissue block. Laser capture microdissection of these airway regions followed by high-resolution proteomic analysis allowed us to begin linking the lipidome with the proteome in a spatially resolved manner, where we observed proteins with high abundance specifically localized to the airway regions. We also compared our mass spectrometry results to lung tissue samples preserved using two other inflation/embedding media, but we identified several pitfalls with the sample preparation steps using this preservation method. Overall, we demonstrated the versatility of the inflation method, and we can start to reveal how the metabolome, lipidome, and proteome are connected spatially in human lungs and across disease states through a variety of different experiments.

59 BASIC BIOLOGICAL SCIENCES↗

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.↗