Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “renewable heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Analysis of pumped thermal energy storage using particle media integrated with concentrating solar power

Pumped Thermal Energy Storage (PTES) is an electricity storage system that converts electricity into thermal energy which is stored and later transformed back into electricity. Previous work has illustrated that particles have low capital costs and can be operated over a wide range of temperatures. PTES with particle storage achieves higher round-trip efficiency and specific power output than when molten salt thermal energy storage is used. This article explores hybrid systems that combine PTES with Concentrating Solar Power (CSP). Hybrid systems share the majority of components thereby reducing costs compared to two stand-alone devices. In addition, hybrid systems can provide multiple services (such as renewable power generation and electricity storage services). Using particle thermal storage in these hybrid concepts provides freedom in choosing the design conditions, since a wide range of operating temperatures is allowable, therefore making it possible to identify hybrid system designs that have good performance. In this article, two concepts for hybrid PTES-CSP are introduced. Thermodynamic models are developed and these are used to evaluate the performance of two hybrid systems. These models account for turbomachinery efficiency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The “Solar Top-Up” Concept uses CSP to increase the temperature delivered by the charging heat pump. The discharging system uses a topping gas cycle and a bottoming steam cycle to fully exploit the available energy. Using solar heat to increase the maximum temperature from 750 K to 1100 K increases the round-trip efficiency from 41 % to 62 % and the specific work output from 88 kJ/kg to 301 kJ/kg. The second concept is a “Dual-Mode” device which provides both electricity storage and solar electricity generation with the same set of components. The PTES-mode and CSP-mode performance are optimized at different design values but careful parameter selection leads to good performance of both modes: one design produces PTES round-trip efficiency > 60 %, CSP heat engine efficiency > 40 %, and specific work outputs > 150 kJ/kg (for both cycles), when the particle receiver temperature is > 1200 K and maximum heat pump temperature is 1100 K.

14 SOLAR ENERGY↗

Optimizing district energy systems under uncertainty: Insights from a case study from Washington D.C., USA

This study investigates solutions for delivering affordable heating and cooling to a brownfield site, focusing on a case study in Washington, DC. Moving towards more diverse and resilient energy systems, we identify the optimal portfolio for a district energy system with diverse energy sources to meet the area’s energy demands. Our methodological approach integrates two detailed models: one calculating building-level energy demand and the other optimizing district energy technology choices based on their demand profiles, accounting for uncertainties in energy prices, policies, and other parameters. The results provide an economic comparison of district and individual supply options at the building level, emphasizing the flexibility district systems can offer to the electricity sector. District energy systems demonstrate cost-stabilization benefits amidst volatile energy prices and external uncertainties. For heating, district systems yield significant cost savings compared to individual solutions, driven by fuel flexibility and the use of local renewable energy sources. For cooling, district systems also show advantages, though individual systems may remain more cost-effective for smaller buildings. Additionally, district systems exhibit considerable flexibility on the heating side, as evidenced by variations in electricity consumption. We recommend future research to explore the relationship between the economics of district energy systems, particularly at the building level, and their flexibility potential for the electricity sector across diverse geographic contexts to reduce overall grid costs and promote grid reliability. This includes areas with distinct zoning laws, municipal priorities, utility structures, and funding mechanisms, such as the United States, and regions like Europe with pronounced electricity price volatility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OptiBench: An Optimization Benchmark Tool for Renewable Energy Problems

We propose a benchmark framework and visualization tool, OptiBench, for analyzing the performance of state-of-the-art optimization solvers across a variety of optimization problems in renewable energy research. Our framework is designed from the ground up in the Julia programming language and enables analysis at scale on high performance computing (HPC) systems. Our visualization tool allows effortless evaluation of optimization solver performance, robustness, and accuracy through intuitive plots, e.g., performance profiles, heat maps, and distribution plots. We have tested three benchmark suites relevant to the modeling of renewable energy systems, viz., CUTEst, PGLib-OPF, and WaterTAP water treatment optimization problems. We illustrate benchmarking of CUTEst using OptiBench on the National Renewable Energy Laboratory's (NREL) HPC Kestrel. Our findings indicate that MA57 HSL linear solver demonstrated the best overall performance for an experimental IPOPT implementation. Our work is ongoing and we intend to add support for more optimization solvers and benchmark test suites in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OptiBench: An Optimization Benchmark Tool for Renewable Energy Problems

We propose a benchmark framework and visualization tool, OptiBench, for analyzing the performance of state-of-the-art optimization solvers across a variety of optimization problems in renewable energy research. Our framework is designed from the ground up in the Julia programming language and enables analysis at scale on high performance computing (HPC) systems. Our visualization tool allows effortless evaluation of optimization solver performance, robustness, and accuracy through intuitive plots, e.g., performance profiles, heat maps, and distribution plots. We have tested three benchmark suites relevant to the modeling of renewable energy systems, viz., CUTEst, PGLib-OPF, and WaterTAP water treatment optimization problems. We illustrate benchmarking of CUTEst using OptiBench on the National Laboratory of the Rockies's (NLR) HPC Kestrel. Our findings indicate that MA57 HSL linear solver demonstrated the best overall performance for an experimental IPOPT implementation. Our work is ongoing and we intend to add support for more optimization solvers and benchmark test suites in the future.

97 MATHEMATICS AND COMPUTING↗

Building Load Control Using Distributionally Robust Chance-Constrained Programs with Right-Hand Side Uncertainty and the Risk-Adjustable Variants

Aggregation of heating, ventilation, and air conditioning (HVAC) loads can provide reserves to absorb volatile renewable energy, especially solar photo-voltaic (PV) generation. In this paper, we decide HVAC control schedules under uncertain PV generation, using a distributionally robust chance-constrained (DRCC) building load control model under two typical ambiguity sets: the moment-based and Wasserstein ambiguity sets. We derive mixed integer linear programming (MILP) reformulations for DRCC problems under both sets. Especially, for the Wasserstein ambiguity set, we use the right-hand side (RHS) uncertainty to derive a more compact MILP reformulation than the commonly known MILP reformulations with big-M constants. All the results also apply to general individual chance constraints with RHS uncertainty. Furthermore, we propose an adjustable chance-constrained variant to achieve tradeoff between the operational risk and costs. We derive MILP reformulations under the Wasserstein ambiguity set and second-order conic programming (SOCP) reformulations under the moment-based set. Using real-world data, we conduct computational studies to demonstrate the efficiency of the solution approaches and the effectiveness of the solutions. Summary of Contribution: The problem studied in this paper is motivated by a building load control problem that uses the aggregation of heating, ventilation, and air conditioning (HVAC) loads as flexible reserves to absorb uncertain solar photovoltaic (PV) generation. The problem is formulated as distributionally robust chance-constrained (DRCC) programs with right-hand side (RHS) uncertainty. In addition, we propose a risk-adjustable variant of the DRCC programs, where the risk level, instead of being predetermined, is treated as a decision variable. The paper aims to provide tractable reformulations and solution algorithms for both the (general) DRCC and the (general) adjustable DRCC models with RHS uncertainty.

97 MATHEMATICS AND COMPUTING↗

Porous Covalent Organic Polymers for Efficient Fluorocarbon‐Based Adsorption Cooling

Abstract Adsorption‐based cooling is an energy‐efficient renewable‐energy technology that can be driven using low‐grade industrial waste heat and/or solar heat. Here, we report the first exploration of fluorocarbon adsorption using porous covalent organic polymers (COPs) for this cooling application. High fluorocarbon R134a equilibrium capacities and unique overall linear‐shaped isotherms are revealed for the materials, namely COP‐2 and COP‐3. The key role of mesoporous defects on this unusual adsorption behavior was demonstrated by molecular simulations based on atomistic defect‐containing models built for both porous COPs. Analysis of simulated R134a adsorption isotherms for various defect‐containing atomistic models of the COPs shows a direct correlation between higher fluorocarbon adsorption capacities and increasing pore volumes induced by defects. Combined with their high porosities, excellent reversibility, fast kinetics, and large operating window, these defect‐containing porous COPs are promising for adsorption‐based cooling applications.

Zheng, Jian↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative techno-economic and environmental analysis of using nuclear energy and fossil energy with carbon sequestration in U.S. Gulf Coast petroleum refineries

U.S. Gulf Coast refineries have processing capacity of approximately 9.4 million barrels of crude oil per day—about 50% of U.S. national capacity—while consuming natural gas, electricity, and hydrogen, resulting in approximately 100 million metric tonnes (MMT) of onsite CO₂ emissions in 2022. This study evaluates two alternative refinery energy supply pathways: nuclear energy (NE) and fossil energy-derived hydrogen with carbon capture and sequestration (FE-CCS; autothermal reforming), intermittent renewable sources are not considered as they cannot reliably meet continuous industrial heat and hydrogen demands. Using publicly available data for refineries, we conducted a bottom-up, facility-level assessment to estimate energy use by type, well-to-gate refinery emissions, and associated costs of integration. Compared to current refinery operations using natural gas energy supply and conventional hydrogen production (steam methane reforming without sequestration), NE and FE-CCS could produce, respectively, average emissions reductions of 37% and 42%, total abatement costs of $\$$52–$\$$221 and $\$$211–$\$$612/MT CO₂, and additional costs of about $\$$0.2–$\$$6 and $\$$3–$\$$11 per barrel of crude, respectively. Our analysis indicates that 25 out of 27 refineries have lower total additional cost ($\$$/bbl.) for the NE scenario than the FE-CCS scenario, making a strong case for NE integration with petroleum refineries. This work's main contribution is a detailed bottom-up refinery-level analysis method that can be utilized by the worldwide refining industry and stakeholders as they assess different technological options, along with their costs and environmental impacts for a specific refinery operation.

Carbon capture and sequestration↗

Estimating the Impacts of Increasing Temperatures and the Efficacy of Climate Adaptation Strategies in Urban Microclimates with Deep Learning

As urbanization and climate change progress, understanding and addressing urban heat becomes a priority for climate adaptation efforts. High temperatures concentrated in the urban core can drive increased risk of heat-related death and illness as well as increased energy demand for cooling. However, modeling the urban microclimate is an ongoing field of research typically burdened by an imprecise description of the built environment, incomplete observational records, significant computational cost, and a lack of high-resolution estimates of the impacts of increasing temperatures. Here, we present computationally efficient machine learning methods that can improve the accuracy of urban temperature estimates when compared to historical reanalysis data. These models are applied to a neighborhood in Los Angeles, and we compare the energy benefits of heat mitigation strategies to the impacts of climate change. We find that cooling demand is likely to increase substantially through midcentury, but engineered high-albedo surfaces could lessen this increase by more than 50 %. The corresponding increase in winter gas heating offsets the summer cooling benefit in the current climate, but total annual energy use from combined heating and cooling with electric heat pumps benefits from the engineered heat mitigation strategies under both current and future climates.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Bulk Oxygen Capacity and Transient Redox Behavior of Foamed Lanthanum Strontium Manganese Perovskites

Synthesis of solar thermochemical hydrogen (STCH) production redox materials with engineered structures, for example, replica foams, can enable efficient heat and mass transport and are critical for scaled-up systems. Prior work has motivated the use of lanthanum strontium manganese (LSM)-type perovskites as foamed STCH materials, but the effect of their morphology on bulk and kinetic behavior has not been reported. In this work, replica and direct foamed samples of La 0.65 Sr 0.35 MnO 3-δ (LSM35) were fabricated and compared to synthesized powders and dense monoliths, and similarly synthesized CeO 2-δ (ceria) foams, regarding their specific reaction rates and bulk oxygen capacity/H 2 yields. Changes in oxygen capacity (Δδ) and reaction rates were measured between 1200 °C and 1400 °C by using fixed ratios of steam and hydrogen during both reduction and oxidation steps, allowing for analysis under practical high conversion conditions. Results suggest bulk behavior and reaction rates of the foamed LSM materials are comparable to their powder analogues. Differences in reaction rates were observed only when replica foamed samples were subjected to rapid laser heating (emulating conditions expected in solar furnaces), which is expected but has not been demonstrated at such a small scale. Here, foamed samples were further subjected to 50 redox cycles at 1400 °C to evaluate their stability. Results show no statistically significant decrease in hydrogen production for any of the foamed samples, but the direct foamed samples became brittle with time. Together, these results demonstrate the viability of replica foamed LSM perovskites for integration in scaled-up STCH systems.

08 HYDROGEN↗

The Effect of Process History on Grain Boundaries and Dislocation Substructures on Functional Properties of Nb for SRF Cavities: Plastic Formability and Microstructural Evolution. Final report

While much progress has been made in improving the performance of cavities in the past decade, reproducible performance remains elusive. This renewal of “The cost of grain boundaries on the performance of superconducting cavities” examines in further depth the interactions between forming and annealing processes and functional performance at the scale of dislocation substructure and grain boundaries. There are five tasks identified in the renewal, which are: Characterization / analysis of current cavity technology: Effect of deformation, heat treatment, surface treatments, and residual damage on cavity function (Lee and Bieler) Characterization of dislocation mechanisms in single and bicrystals (Bieler) Quantifying effects of impurities and deformation mechanisms in Nb using density functional theory calculations (Solanki) Crystal plasticity constitutive model development (Pourboghrat and Eisenlohr) Modeling and measuring thermal conductivity in thin layers (Wright)

36 MATERIALS SCIENCE↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled Heat Power Operation of Smart Buildings via Modular Pumped Hydro Storage

In the United States, building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings’ energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low-grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high-efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground level. This unique design eliminates the geographical limitation associated with the existing state-of-the-art energy storage technologies. It is easy to be scaled for building level, community level, and grid level applications. By using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g., from thermal storage, combined cooling, heat and power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Here, several groups of comparison experiments have been conducted, and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

H2@Scale 2.0: Realizing the Benefits of a Hydrogen-Based Energy System

Throughout the world, hydrogen is increasingly recognized as the critical, central component for a clean, sustainable, efficient, and economic energy system. Hydrogen is remarkable for its ability to carry, store, and interconvert energy - its chemical energy can be used for clean and efficient chemical conversions to products and fuels; electricity generation; and heat generation. Hydrogen can be used as a storage medium, even for seasonal storage, to enable larger-scale deployment and use of renewable electricity. As an energy carrier, hydrogen is central to cross-sector coupling and clean, efficient transportation fuels and industrial processes, enabling decarbonization of products and services while meeting customer expectations.

chemical conversions↗

Conversion of food waste to renewable energy: A techno-economic and environmental assessment

Increasing quantities of food waste have become a concern due to high disposal costs in landfills and high greenhouse gas emissions. With this increase in food waste generation, there is also an increasing demand for renewable natural gas to supplement traditional fossil fuel combustion and offset the impacts of climate change. Collecting food waste from landfills and turning it into renewable natural gas using anaerobic digestion could be a win-win option for both food waste disposal and renewable energy production. While some literature exists on the energy potential, economic feasibility, and environmental benefit of food waste disposal via anaerobic digestion, no existing study simultaneously evaluates the energy, economic and environmental effect of food waste to renewable energy via anaerobic digestion, especially on a plant and city scale. Further, this study is focused on the techno-economic and environmental assessment of food waste to energy via anaerobic digestion in order to fill this gap. Four anaerobic digestion pathways are considered in this study: flare, pipeline natural gas, combined heat and power, and combined cycle for efficient power generation. Using a city of 1M people the results show that renewable natural gas from food waste could supply the natural gas usage for 1.9% of residential use, 2.7% of commercial use, 1.1% of industrial use, 167.5% of the compressed natural gas vehicle fleet, 0.7% of electric power generation, or 2.5% of industrial high-temperature heating processes. All pathways except pipeline natural gas will have a positive net present value in the baseline scenario, and the pipeline natural gas pathway will become economically viable with a net present value of 31 USD/t of food waste with renewable energy credits. Lastly, all of the pathways achieve negative greenhouse gas emissions, which indicates that anaerobic digestion is a more environmentally friendly method for the handling of food waste than landfills.

03 NATURAL GAS↗