Comparison of Standards and Technical Requirements of Grid-Connected Wind Power Plants in China and the United States

The rapid deployment of wind power has made grid integration and operational issues focal points in industry discussions and research. Compliance with grid connection standards for wind power plants (WPPs) is crucial to ensuring the reliable and stable operation of the electric power grid. This report compares the standards for grid-connected WPPs in China to those in the United States to facilitate further improvements in wind power standards and enhance the development of wind power equipment. Detailed analyses of power quality, low-voltage ride-through capability, active power control, reactive power control, voltage control, and wind power forecasting are provided to enhance the understanding of grid codes in the two largest markets of wind power. This study compares WPP interconnection standards and technical requirements in China to those in the United States.

17 WIND ENERGY↗

Empirical Validation of Building Energy Modeling using Flexible Research Platform

Recently, efforts have been made to provide reliable empirical data for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, to enable improved accuracy of building energy model (BEM) engines and improved characterization of their accuracy. The motivation for this effort is that the use of reliable empirical validation data sets in the evaluation of building energy modeling tools will lead to more consistent and validated simulation engines across all software vendors. This would expedite the use of building energy modeling in designing new buildings and retrofitting existing buildings, which delivers more energy efficient buildings.As part of a three-year multi-lab empirical validation project sponsored by U.S. DOE, this research project generated cooling season test plans by reviewing ASHRAE Standard 140, and the tests were performed based on the test plan. Finally, the experimental data sets were compared with the EnergyPlus model to demonstrate the validation procedure.

Im, Piljae↗

Evaluating the Performance of the IEEE Standard 1366 Method for Identifying Major Event Days

IEEE Standard 1366 offers a method for segmenting reliability performance data to isolate the effects of major events from the underlying year-to-year trends in reliability. Recent analysis by the IEEE Distribution Reliability Working Group (DRWG) has found that reliability performance of some utilities differs from the expectations that helped guide the development of the Standard 1366 method. This paper proposes quantitative metrics to evaluate the performance of the Standard 1366 method in identifying major events and in reducing year-to-year variability in utility reliability. The metrics are applied to a large sample of utility-reported reliability data to assess performance of the method with alternative specifications that have been considered by the DRWG. We find that none of the alternatives perform uniformly 'better' than the current Standard 1366 method. That is, none of the modifications uniformly lowers the year-to-year variability in System Average Interruption Duration Index without major events. Instead, for any given alternative, while it may lower the value of this metric for some utilities, it also increases it for other utilities (sometimes dramatically). Thus, we illustrate some of the trade-offs that must be considered in using the Standard 1366 method and highlight the usefulness of the metrics we have proposed in conducting these evaluations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State Spotlight on Resilience: The Michigan Public Service Commission and Data Informed Accountability

Resilience activities are an emerging area within regulatory utility policy. As resilience frameworks develop, many Public Utility Commissions (PUCs) are looking to initiate resilience activities and have identified enhancing grid reliability as a practical starting point. Reliability describes the grid’s ability to deliver electricity steadily and without interruptions under normal or “blue sky” conditions. Reliability is measured using industry standard metrics such as outage frequency (SAIFI) and outage duration (SAIDI). Resilience is broader, reflecting the grid’s ability to both withstand and recover from disruptions, particularly those caused by extreme events such as severe storms. A reliable grid minimizes routine disruptions; a resilient grid ensures the system can recover quickly when disruptions occur, preventing them from escalating into widespread or prolonged crises.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Moving Toward Quantifying Reliability - The Next Step in a Rapidly Maturing PV Industry: Preprint

Some may say that PV modules are moving toward being a simple commodity, but most major PV customers ask: 'How can I minimize chances of a module recall?' Or, 'How can I quantify the added value of a 'premium' module?' Or, 'How can I assess the value of an old PV system that I'm thinking of purchasing?' These are all questions that PVQAT (the International PV Quality Assurance Task Force) and partner organizations are working to answer. Defining standard methods for ensuring minimal acceptable quality of PV modules, differentiating modules that provide added value in the toughest of environments, and creating a process (e.g. through IECRE [1]) that can follow a PV system from design through installation and operation are tough tasks, but having standard approaches for these will increase confidence, reduce costs, and be a critical foundation of a mature PV industry. This paper summarizes current needs for new tests, some challenges for defining those tests, and some of the key efforts toward development of international standards, emphasizing that meaningful quantification of reliability (as in defining a service life prediction) must be done in the context of a specific product with design parameters defined through a quality management system.

14 SOLAR ENERGY↗

A Revised International Standard for Gearboxes in Wind Turbine Systems

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

gearbox↗

A Revised International Standard for Gearboxes in Wind Turbine Systems: Preprint

Gearbox and wind turbine design and application standards have contributed significantly to improvements in reliability over the past two decades. The International Electrotechnical Commission (IEC) 61400-4 standard of wind turbine gearbox design is currently being revised by a joint working group (JWG) of experts in IEC TC 88 (wind energy) and International Organization for Standardization (ISO) TC60 (gears) to further that effort. Experts from ISO TC4 (rolling bearings) and ISO TC28 (lubricants) have actively participated. This revision has implemented lessons learned from industry use of edition 1 since its publication in 2012. The main document, IEC 61400-4, was pared down to essential design requirements and application-specific recommendations along with a design verification framework. The JWG leveraged concurrent development of other standards, such as IEC 61400-8 on wind turbine structures, to replace edition 1 content. These are described along with how this works with the IEC Renewable Energy certification scheme for wind turbines (IECRE-WE). The JWG recognized the interest in maintaining informative parts of edition 1 including annexes on wind turbine architecture and loads, bearing and gear arrangements, bearing selection, lubrication system descriptions and lubricant performance recommendations. This information was retained in two technical reports: IEC/TR 61400-4-2 Lubrication and IEC/TR 61400-4-3 Explanatory Notes. Additionally, a technical specification, IEC/TS 61400-4-1, was drafted to provide a reliability calculation method for comparing different design options or conditions. Salient elements of these documents are described. All four documents were recently distributed for IEC/ISO review, ballot, and comment. Publication is expected in 2023.

ENGINEERING,WIND ENERGY↗

EMT data generation

The integration of inverter-based resources (IBRs) in power systems is accelerating, bringing with it significant benefits such as reduced greenhouse gas emissions, improved grid resilience, and increased energy independence. Despite these advantages, the widespread adoption of IBRs introduces several challenges, including issues related to grid stability, increased operational complexity, and the need for updated regulatory frameworks. To address these challenges, IEEE released Standard 2800 in 2022, which sets forth the necessary interconnection capabilities and performance criteria for IBRs connected to transmission and sub-transmission systems. This standard outlines the performance requirements to ensure the reliable integration of IBRs into the bulk power system. Furthermore, in 2023, the North American Electric Reliability Corporation (NERC) published a reliability guideline for electromagnetic transient (EMT) modeling of BPS-connected IBRs. This guideline provides recommendations for developing EMT model requirements, performing model quality checks, and implementing verification practices specifically for EMT models representing BPS-connected inverter-based resources in reliability studies conducted by transmission planners and planning coordinators. These standards and guidelines have a profound impact on EMT studies for transmission networks, influencing system stability analyses, grid recovery and resynchronization processes, fault ride-through evaluations, protection and coordination strategies, advanced control methodologies, and the inclusion of IBRs in transient models of transmission networks. As a result, the generation of EMT data is crucial for conducting various transient-based studies to understand the impact of IBRs. EMT data generation use cases serve as the basis for scenarios in event detection and identification use cases, providing comprehensive details about EMT data generation for transmission grids with inverter-based resources. These use cases supply sufficient training and validation datasets for subsequent EMT analysis algorithms.

Xia, Qianxue↗

Preliminary Measurements of Partial Discharge Inception Voltage Degradation with Constant Temperature Aging of Magnet Wire Twisted Pairs for Electric Aircraft Motors

Electric aircraft require high reliability electric motors to meet the stringent safety standards of the aviation industry. Motor winding insulation lifetime and reliability models for electric aircraft applications are needed to enable design of high reliability and high-performance electric motors for aviation applications. Three primary stresses effect the lifetime of motor winding insulation: thermochemical, mechanical, and electrical. This paper presents preliminary experiments on twisted pairs of magnet wire targeting understanding the thermo-chemical degradation of motor winding insulation through constant temperature thermal aging. Three types of magnet wire twisted pairs where tested: polyimide insulated magnet wire, epoxy coated polyimide insulated magnet wire, and epoxy potted polyimide magnet wire. The degradation of the samples over time at temperature was tracked using partial discharge inception voltage measurements. These initial experiments were used for development of procedures and expertise in partial discharge testing and thermo-chemical aging to inform future testing. The preliminary nature of these experiments should be noted when viewing the results. Lessons learned from the experiments are documented.

Thomas Tallerico↗

A Ground-Based Comparison of the Muscle Atrophy Research and Exercise System (MARES) and a Standard Isokinetic Dynamometer

PURPOSE: 1) To compare the test-to-test reliability of Muscle Atrophy Research and Exercise System (MARES) with a standard laboratory isokinetic dynamometer (ISOK DYN) and; 2) to determine if measures of peak torque and total work differ between devices. METHODS: Ten subjects (6M, 4F) completed two trials on both MARES and an ISOK DYN in a counterbalanced order. Peak torque values at 60 deg & 180 deg / s were obtained from five maximal repetitions of knee extension (KE) and knee flexion (KF). Total work at 180 deg / s was determined from the area under the torque vs. displacement curve during twenty maximal repetitions of KE and KF. Reliability of measures within devices was interpreted from the intraclass correlation coefficient (ICC) and compared between devices using the ratio of the within-device standard deviations. Indicators of agreement for the two devices were evaluated from: 1) a calculation of concordance (rho) and; 2) the correlation between the mean of measures versus the delta difference between measures (m u vs delta). RESULTS: For all outcome measures ICCs were high for both the ISOK DYN (0.95-0.99) and MARES (0.90-0.99). However, ratios of the within-device standard deviation were 1.3 to 4.3 times higher on MARES. On average, a wide range (3.3 to 1054 Nm) of differences existed between the values obtained. Only KE peak torque measured at 60 deg & 180 deg / s showed similarities between devices (rho = 0.91 & 0.87; Pearson's r for m u vs delta = -0.22 & -0.37, respectively). CONCLUSION: Although MARES was designed for use in microgravity it was quite reliable during ground-based testing. However, MARES was consistently more variable than an ISOK DYN. Future longitudinal studies evaluating a change in isokinetic peak torque or total work should be limited within one device.

Hackney, K. J.↗

Development of Offshore Wind Recommended Practice for U.S. Waters: Preprint

This paper discusses how the American Petroleum Institute oil and gas standards were interfaced with International Electrotechnical Commission and other wind turbine and offshore industry standards to provide guidance for reliable engineering design practices for offshore wind energy systems.

17 WIND ENERGY↗

Hg(+) Frequency Standards

In this paper we review the development of Hg(+) microwave frequency standards for use in high reliability and continuous operation applications. In recent work we have demonstrated short-term frequency stability of 3 x 10(exp -14)/nu(sub tau) when a cryogenic oscillator of stability 2-3 x 10(exp 15) was used a the local oscillator. The trapped ion frequency standard employs a Hg-202 discharge lamp to optically pump the trapped Hg(+)-199 clock ions and a helium buffer gas to cool the ions to near room temperature. We describe a small Hg(+) ion trap based frequency standard with an extended linear ion trap (LITE) architecture which separates the optical state selection region from the clock resonance region. This separation allows the use of novel trap configurations in the resonance region since no optical pumping is carried out there. A method for measuring the size of an ion cloud inside a linear trap with a 12-rod trap is currently being investigated. At approx. 10(exp -12), the 2nd order Doppler shift for trapped mercury ion frequency standards is one of the largest frequency offsets and its measurement to the 1% level would represent an advance in insuring the very long-term stability of these standards to the 10(exp -14) or better level. Finally, we describe atomic clock comparison experiments that can probe for a time variation of the fine structure constant, alpha = e(exp 2)/2(pi)hc, at the level of 10(exp -20)/year as predicted in some Grand Unified String Theories.

Prestage, John D.↗

Calibration of multisite raters for prospective visual reads of amyloid PET scans

Abstract INTRODUCTION In multicenter Alzheimer's disease studies, amyloid positron emission tomography (PET) visual reads are typically performed centrally by a few experts. Incorporating a broader reader network enhances scalability and generalizability. METHODS Ten neuroimaging experts from eight Alzheimer's Disease Research Centers (ADRCs) visually read 180 amyloid PET scans (30 scans and 15 duplicate scans for each of four tracers, imaged across a wide variety of scanners), using preferred reading software without anatomical imaging or quantitation. Scans were classified as elevated or non‐elevated per tracer‐specific criteria. Inter‐ and intra‐rater agreement was assessed. RESULTS Inter‐rater agreement was substantial (Fleiss’κ = 0.78), with full consensus on 69% of scans. Inter‐rater reliability was substantial to perfect across tracers (Fleiss’κ = 0.70–0.87). Intra‐rater agreement was substantial to perfect (Cohen'sκ = 0.79‐1). Scans with intermediate (10–40 Centiloid) quantitation had lower reader agreement. DISCUSSION A multicenter expert network achieved substantial agreement classifying amyloid PET scans. These scans provide a standard for reader training and reliability assurance in future studies. Highlights Calibration methods ensure reliable amyloid positron emission tomography (PET) visual reads across multiple raters. Substantial agreement is possible across readers using their preferred tools. Agreement is also substantial regardless of the amyloid PET tracer used. Scans with intermediate (10–40 Centiloid) quantitation have lower reader agreement. The calibration set will become a training tool for amyloid PET visual read studies.

Neurosciences & Neurology↗

Flaw Tolerance Assessment for DOE Standard SNF Dry Storage Canisters - 26550

The U.S. DOE has designed four spent nuclear fuel (SNF) dry storage canisters for storing DOE standardized SNFs. The DOE standard canisters are cylindrical shells with a diameter of 24 inches (610 m) or 18 inches (457 m), a wall thickness of 0.5 inches (12.7 m) or 0.375 inches (9.53 m), and a length of 15 feet (4.57 m) or 10 feet (3.05 m). These DOE canister geometries are completely different from commercial canisters. The latter may experience chloride-induced stress cracking corrosion (CI-SCC) because they are stored near coastal regions. The former may not experience CI-SCC but face different challenges because they are stored in the SNF storage facilities. Because of large residual stresses, mechanical flaws may occur in the DOE canisters during long-distance transportation or lifting handling. To date, only limited structural integrity analyses were carried out through drop tests on the DOE canisters, but a more general flaw tolerance assessment has not been performed. Therefore, the failure assessment diagram (FAD)-based fracture mechanics method, as codified by the latest API 579-1/ASME FFS-1-2021 Edition, is adopted in this work to assess surface flaw tolerance for DOE canisters under operation loading and welding residual stresses (WRS), where the new code-recommended WRS distributions are used. To more adequately consider the transverse distribution of WRS, an equivalent WRS distribution is proposed to account for the WRS reduction with distance from the weld centerline. Moreover, the closed-form solutions of stress intensity factor K, which serves as the crack driving force during subcritical crack growth, are developed from the tabular data of the K factors provided in API 579-1/ASME FFS-1 and used to determine more accurate flaw sizes at flaw instability. Subsequently, the Level 2 assessment procedures with 12 assessment steps, as codified and detailed in API 579-1 and ASME FFS-1, are followed to assess the flaw tolerance for the surface flaws in the DOE standard canisters with consideration of normal or accident operation loads combined with WRS. The assessment results show that the four designs of DOE standard canisters can tolerate all surface flaws that meet the code permitted maximum sizes of a flaw length of 8 inches (i.e., 200 mm) and a flaw depth of 80% wall thickness. This demonstrates that all designs of DOE standard canisters are robust and reliable.

DOE standard canister↗

Efficiency and Reliability Analyses of AC and 380V DC Distribution in Data Centers

Modern data centers consume large amounts of electricity, resulting in high operational costs. The efficiency of a data center power distribution system can be increased, and the operational cost reduced, if the number of power conversion stages can be minimized and more efficient converters, such as wide bandgap (WBG) converters, are used. This can be achieved by using DC distribution voltage at the rack level by eliminating extra conversion stages. In this paper, benchmarks for both AC and 380V DC data centers were developed and efficiency analyses were performed for an entire year. The impact of integrating photovoltaic (PV) systems into the data centers has also been analyzed in both cases in terms of efficiency. The results show that 380V DC data centers are more efficient than AC data centers with and without PV integration. Furthermore, the reliability of an AC system was compared to a 380V DC architecture with Tier-IV standard. Monte-Carlo simulations were used to perform reliability analyses for different levels of redundancy in the Uninterruptible Power Supply (UPS) system for both cases. In conclusion, the simulation results showed that the 380V DC distribution system had a higher level of reliability than the AC distribution system in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cloud-based Testbed for Adaptive Under-Frequency Load Shedding with High DER Penetration

Increasing penetration of distributed energy resources and behind-the-meter renewables may soon disrupt the efficacy of critical protection schemes, such as under-frequency load shedding (UFLS). Improved data exchange and coordination across the transmission-distribution boundary will be required to maintain reliability of bulk electric system. Standards-based data integration platforms using agreed-upon semantic vocabularies, such as the Common Information Model, will be key to enabling adaptive protection schemes requiring synthesized data from both the bulk power system and behind-the-meter resources. This paper introduces a cloud-based open-source data integration environment and UFLS clustering algorithm being developed to enable adaptive relay coordination between transmission and distribution utilities in the state of Vermont.

Anderson, Alexander A.↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗