Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reduce task”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

WM26 Paper Multi-Robot Collaboration for Hazardous Environments

Hazardous nuclear and industrial facilities are rarely designed for robots. Work in these domains demand precise manipulation and robust mobility in cluttered, constrained spaces where off-the-shelf platforms struggle and “one-size-fits-all” machines become costly and complex. Idaho National Laboratory (INL) is developing an autonomous, multi-robot inspection system that coordinates task-specific platforms rather than relying on a single omni-tool robot. An electric truck serves as a power and compute hub for a custom manipulator co-developed with Florida International University (FIU), a commercial mini crawler, a pan–tilt–zoom camera, and a Nexxis Argus LiDAR mapping system. Working in concert, these robots generate spatial, radiation, and temperature maps of the pit environments at the Hanford Waste Tank Farms. These systems will capture visual records and environmental telemetry to allow for analysis post inspection. The system architecture uses Robot Operating System 2 (ROS 2) for publish/subscribe integration, NVIDIA Isaac Sim and Unity for simulation and visualization, and algorithms such as NVBlox to fuse data into unified 3D overlays. This robot-agnostic approach reduces operator burden by enabling autonomy across heterogeneous platforms and lets each robot be used where it is strongest. Having autonomous functions means operators don’t have to fully control multiple different components. The ease of use could allow for more widespread adoption of advanced robotics at waste management sites that see continued use. By coordinating simpler, purpose-built mechanisms, the approach lowers design and manufacturing complexity, reduces capital risk in contaminated settings, and improves controllability for complex inspection and manipulation tasks. We present the architecture, early results, and lessons learned from building and deploying this coordinated multi-robot system, with the goal of accelerating safe, cost-effective adoption of advanced robotics at waste-management sites.

42 - ENGINEERING↗

Methods for the Automated Determination of Sustained Maximum Amplitudes in Oscillating Signals

Machine condition monitoring has been proven to reduce machine downtime and increase productivity. The state-of-the-art research uses vibration monitoring for tasks such as maintenance and tool wear prediction. A less explored aspect is how vibration monitoring might be used to monitor equipment sensitive to vibration. In a manufacturing environment, one example of where this might be needed is in monitoring the vibration of optical linear encoders used in high-precision machine tools and coordinate measuring machines. Monitoring the vibration of sensitive equipment presents a unique case for vibration monitoring because an accurate calculation of the maximum sustained vibration is needed, as opposed to extracting trends from the data. To do this, techniques for determining sustained peaks in vibration signals are needed. Here, this work fills this gap by formalizing and testing methods for determining sustained vibration amplitudes. The methods are tested on simulated signals based on experimental data. Results show that processing the signal directly with the novel Expire Timer method produces the smallest amounts of error on average under various test conditions. Additionally, this method can operate in real-time on streaming vibration data.

Industrial Internet of Things↗

TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-00: Eye Lens Dosimetry for Patients and Staff

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

Dosimetric effects caused by couch tops and immobilization devices: Report of AAPM Task Group 176

The dosimetric impact from devices external to the patient is a complex combination of increased skin dose, reduced tumor dose, and altered dose distribution. Although small monitor unit or dose corrections are routinely made for blocking trays, ion chamber correction factors, e.g., accounting for temperature and pressure, or tissue inhomogeneities, the dose perturbation of the treatment couch top or immobilization devices is often overlooked. These devices also increase skin dose, an effect which is also often ignored or underestimated. These concerns have grown recently due to the increased use of monolithic carbon fiber couch tops which are optimal for imaging for patient position verification but cause attenuation and increased skin dose compared to the “tennis racket” style couch top they often replace. Also, arc delivery techniques have replaced stationary gantry techniques which cause a greater fraction of the dose to be delivered from posterior angles. A host of immobilization devices are available and used to increase patient positioning reproducibility, and these also have attenuation and skin dose implications which are often ignored. This report of Task Group 176 serves to present a survey of published data that illustrates the magnitude of the dosimetric effects of a wide range of devices external to the patient. The report also provides methods for modeling couch tops in treatment planning systems so the physicist can accurately compute the dosimetric effects for indexed patient treatments. Both photon and proton beams are considered. A discussion on avoidance of high density structures during beam planning is also provided. An important aspect of this report are the recommendations the authors make to clinical physicists, treatment planning system vendors, and device vendors on how to make measurements of surface dose and attenuation and how to report these values. For the vendors, an appeal is made to work together to provide accurate couch top models in planning systems.

60 APPLIED LIFE SCIENCES↗

Development of an Optimized Gasoline Surrogate Formulation for PACE Experiments and Simulations

New powertrain solutions are needed to address societal challenges stemming in part from a transportation sector which relies heavily on combustion of conventional hydrocarbon fuels like gasoline. One way to advance new solutions is through predictive simulations. Predictive simulations can potentially limit the extent of experimental validations, reduce time spent in engineering design cycles, unlock new strategies for high efficiency combustion with power density, and minimize tailpipe emissions. However, the simulation tools currently available are either too computationally expensive, inadequate in their accuracy, or a combination of the two. A DOE-funded consortium of national laboratories called the Partnership to Advance Combustion Engines (PACE) seeks to address this gap by rapidly delivering new knowledge and tools which enable market-competitive powertrain solutions for light-duty vehicles. Approaches to modeling combustion in powertrain systems typically incorporate computational fluid dynamics (CFD) simulations with chemical kinetic models. These CFD simulations generally use surrogate fuels featuring a limited number of existing components in a reduced kinetic model to limit computational costs. Such surrogate fuels often sacrifice matching several or more combustion and physical properties of the target gasoline fuel. Validation of surrogate fuels is also often only pursued for a small subset of standard metrics such as research or motor octane number (RON, MON). The purpose of this project is to develop an optimal E10 gasoline surrogate fuel suitable for tasks across PACE to facilitate rapid common analysis and progression toward consortium goals. This project received contributions from tasks led by eight PACE principal investigators. The project funding here reflects all tasks under Pitz, whose tasks also contributed to additional PACE projects. Based on the optimal gasoline surrogate fuel composition, a reduced chemical kinetic model will be shared with PACE researchers, industry, and the broader combustion community.

33 ADVANCED PROPULSION SYSTEMS↗

High Energy Yield Distributed Architecture for Large Commercial and Utility-Scale PV Systems

Photovoltaic energy has come a long way from its early days when small cells were fabricated in the labs in the early 50s. While it took a long time for PV modules to mature into what we now see in the market and in rooftops across the world, the power electronics has been lagging behind & was always the weakest point in the PV plant, being responsible for the majority of failures & robbing the PV plants of their full potential by losing precious Watts in the process of converting power from DC to AC. Since the early days of PV power, it has been recognized that the modules need to operate at their maximum power point in order to extract as much power as is available from the PV modules at a given time of day and year. Numerous maximum power point devices were developed to do just this. While effective at extracting as much power as they can, soon after there was a realization that in a PV installation where a central inverter is used, many losses occur, hence energy yield losses. This has led to thinking about alternative architectures where the maximum power point tracking (MPPT) is performed much closer to the modules rather than at a central inverter. Several architectures were proposed ranging from a microinverter, microconverter, string inverter, string optimizer, and to a multi-string inverter or optimizer. While these architectures promise to increase the energy yield by 5% to 25% (depending where MPPT is located), & recovering losses due to shading, soiling, mismatch … there were no real studies and implementations in the field to corroborate these numbers. The program that GE Global Research proposed & received funding for is aimed at a type of distributed architectures, namely the dc architectures where only the MPPT function is distributed across the PV plant. Further, the project is concerned with choosing the right architecture for large scale commercial & utility scale plants but not residential installations. Findings from Task 1- Define Requirements & Develop Architecture- showed that for large scale commercial & utility PV plants, locating the MPPT at the string level with a string size of >3kW is the most cost effective solution & that the increase in energy yield of 6% to 8% is more than enough to make up for the increased cost due to additional power electronics. Our study also shows that in addition to an increase in energy yield, having a dc/dc converter at the string level brings additional benefits such as increased array visibility, allowing for increased monitoring and diagnostics; high and constant dc bus voltage which allows for reducing losses further and optimizing the inverter; and ability to detect ground and arc faults. Task 2 focused on designing a suitable dc/dc converter that meets the requirements defined in Task 1: Efficiency, Cost, & Reliability. For this task, we surveyed and simulated all candidate topologies known by the practitioners in the field. We also generated a novel topology, simulated it, & compared it to existing topologies. Our novel topology being a partial power processing converter came out on top due to its simplicity (fewer parts), it high efficiency, its reliability, and its lower cost. In the remaining tasks of the project, we built the hardware, tested it first in the lab, then in the field and once we worked out all the bugs and issues and were confident our system was robust, we installed it on the rooftop and started collecting the data by mid-Q3 2012. We shared our work with the scientific community in the form of conference & Journal papers, hence contributing to the general understanding of this technology area. The methods, techniques, and hardware developed under this project have all been tested in the field over long periods of time, and under many conditions and have been shown to be robust and reliable. The converters built and developed under this program have been in operation in the field since mid-June 2012, and no hardware failures have been recorded. While some software issues have been seen, none have been showstoppers. The cost analysis of the hardware showed that it meets the cost target set in the requirement document developed in the trade-off study. Improving the performance of solar installations for commercial and utility scale plants contributes to reducing their cost of ownership, hence spreading them to a larger section of the society and making them affordable. Our project contributed to the understanding of the distributed architectures, showed that PV plants’ cost of electricity can be reduced through additional power electronics which allows for harvesting more energy from the plant. When the project started in 2009, the cost of PV energy was still high, hence there was a real need to increase the energy yield, hence reduce the levelized cost of electricity (LCOE). While costs have come down significantly, the need for increasing the energy yield is still relevant, hence the project results, hardware, and techniques developed are still pertinent today. By taking this project from concept to rooftop demonstration, we showed that the technology is mature enough, robust enough, and has the potential to be used by many more customers, hence benefiting the public in general through the spread of PV energy, which ultimately contributes to reducing our dependency on fossil fuel, improving the environment, and creating more jobs.

14 SOLAR ENERGY↗

SU-F-18C-02: Evaluations of the Noise Power Spectrum of a CT Iterative Reconstruction Technique for Radiation Therapy

Purpose: To quantitatively assess the noise power spectrum (NPS) of the new, commercially released CT iterative reconstruction technique, iDose{sup 4} from Philips, to compare it with filtered back-projection techniques (FBP), and to provide clinical practice suggestions for radiation therapy. Methods: A uniform phantom was CT imaged with 120kVp tube potential over a range of mAs (250-3333). The image sets were reconstructed using two reconstruction algorithms (FBP and iDose{sup 4} with noise reduction levels 1, 3, and 6) and three reconstruction filters (standard B, smooth A, and sharp C), after which NPS variations were analyzed and compared on region of interest (ROI) sizes (16×16 to 128×128 pixels), ROI radii (0–65 mm), reconstruction algorithms, reconstruction filters, and mAs. Results: The NPS magnitude and shape depended considerably on ROI size and location for both reconstruction algorithms. Regional noise variance became more stationary as ROI size decreased, minimizing NPS artifacts. The optimal 32×32-pixel ROI size balanced the trade-off between stationary noise and adequate sampling. NPS artifacts were greatest at the center of reconstruction space and decreased with increasing ROI distance from the center. The optimal ROI position was located near the phantom's radial midpoint (∼40mm). For sharper filters, the NPS magnitude and the maximum magnitude frequency increased. Higher dose scans yielded lower NPS magnitudes for both reconstruction algorithms and all filters. Compared to FBP, the iDose{sup 4} algorithm reduced the NPS magnitude while preferentially reducing noise at mid-range spatial frequencies, altering noise texture. This reduction was more significant with increasing iDose{sup 4} noise reduction level. Conclusion: Compared to pixel standard deviation, NPS has greater clinical potential for task-based image quality assessment, describing both the magnitude and spatial frequency characteristics of image noise. While iDose{sup 4} reduces the NPS magnitude more dramatically than FBP, further studies are needed to assess the impacts of noise texture alteration on its clinical usage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nexus: a modular workflow management system for quantum simulation codes

The management of simulation workflows is a significant task for the individual computational researcher. Automation of the required tasks involved in simulation work can decrease the overall time to solution and reduce sources of human error. A new simulation workflow management system, Nexus, is presented to address these issues. Nexus is capable of automated job management on workstations and resources at several major supercomputing centers. Its modular design allows many quantum simulation codes to be supported within the same framework. Current support includes quantum Monte Carlo calculations with QMCPACK, density functional theory calculations with Quantum Espresso or VASP, and quantum chemical calculations with GAMESS. Users can compose workflows through a transparent, text-based interface, resembling the input file of a typical simulation code. A usage example is provided to illustrate the process.

97 MATHEMATICS AND COMPUTING↗

Position-momentum uncertainty relations in the presence of quantum memory

A prominent formulation of the uncertainty principle identifies the fundamental quantum feature that no particle may be prepared with certain outcomes for both position and momentum measurements. Often the statistical uncertainties are thereby measured in terms of entropies providing a clear operational interpretation in information theory and cryptography. Recently, entropic uncertainty relations have been used to show that the uncertainty can be reduced in the presence of entanglement and to prove security of quantum cryptographic tasks. However, much of this recent progress has been focused on observables with only a finite number of outcomes not including Heisenberg’s original setting of position and momentum observables. Here, we show entropic uncertainty relations for general observables with discrete but infinite or continuous spectrum that take into account the power of an entangled observer. As an illustration, we evaluate the uncertainty relations for position and momentum measurements, which is operationally significant in that it implies security of a quantum key distribution scheme based on homodyne detection of squeezed Gaussian states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status of h-BN quasi-bulk crystals and high efficiency neutron detectors

III-nitrides have fomented a revolution in the lighting industry and are poised to make a huge impact in the field of power electronics. In the III-nitride family, the crystal growth and use of hexagonal BN (h-BN) as an ultrawide bandgap (UWBG) semiconductor are much less developed. Bulk crystals of h-BN produced by the high-temperature/high-pressure and the metal flux solution methods possess very high crystalline and optical qualities but are impractical to serve as substrates or for device implementation as their sizes are typically in millimeters. The development of crystal growth technologies for producing thick epitaxial films (or quasi-bulk or semi-bulk crystals) in large wafer sizes with high crystalline quality is a prerequisite for utilizing h-BN as an UWBG electronic material. Compared to traditional III-nitrides, BN has another unique application as solid-state neutron detectors, which however, also require the development of quasi-bulk crystals to provide high detection efficiencies because the theoretical efficiency (ηi) relates to the detector thickness (d) by ηi=1−e−dλ, where λ denotes the thermal neutron absorption length which is 47 μm (237 μm) for 10B-enriched (natural) h-BN. We provide an overview and recent progress toward the development of h-BN quasi-bulk crystals via hydride vapor phase epitaxy (HVPE) growth and the attainment of thermal neutron detectors based on 100 μm thick 10B-enriched h-BN with a record efficiency of 60%. The thermal neutron detection efficiency was shown to enhance at elevated temperatures. Benchmarking the crystalline and optical qualities of h-BN quasi-bulk crystals with the state-of-the-art mm-sized bulk crystal flakes and 0.5 μm thick epitaxial films identified that reducing the density of native defects such as vacancies remains the most critical task for h-BN quasi-bulk crystal growth by HVPE.

Physics↗

Efficient Data Management in Neutron Scattering Data Reduction Workflows at ORNL

Oak Ridge National Laboratory (ORNL) experimental neutron science facilities produce 1.2 TB a day of raw event-based data that is stored using the standard metadata-rich NeXus schema built on top of the HDF5 file format. Performance of several data reduction workflows is largely determined by the amount of time spent on the loading and processing algorithms in Mantid, an open-source data analysis framework used across several neutron sciences facilities around the world. The present work introduces new data management algorithms to address identified input output (I/O) bottlenecks on Mantid. First, we introduce an in-memory binary-tree metadata index that resemble NeXus data access patterns to provide a scalable search and extraction mechanism. Second, data encapsulation in Mantid algorithms is optimally redesigned to reduce the total compute and memory runtime footprint associated with metadata I/O reconstruction tasks. Results from this work show speed ups in wall-clock time on ORNL data reduction workflows, ranging from 11% to 30% depending on the complexity of the targeted instrument-specific data. Nevertheless, we highlight the need for more research to address reduction challenges as experimental data volumes increase.

Godoy, William↗

EQC: Ensembled Quantum Computing for Variational Quantum Algorithms

Variational quantum algorithms (VQA), which are comprised of a classical optimizer and a parameterized quantum circuit, emerges as one of the most promising approaches of harvesting quantum power in the noisy-intermediate-scale-quantum (NISQ) era. However, the deployment of VQAs on today's NISQ devices often faces considerable system noise and prohibitively slow training speeds. On the other hand, the expensive supporting sources and infrastructure make quantum computers extremely keen on high utilization. In this paper, we propose a novel way of thinking about a quantum backend: rather than relying on one physical device which tends to introduce platform-specific noise and bias, a quantum ensemble, which distributes quantum tasks across parallel devices, can serve as a virtualized quantum computer for offering reduced noise levels through an adaptive mixture and also provide significantly improved training speeds through parallelization. With this idea, we build a distributive VQA optimization framework called DVQA, serving as the first effort in adopting parallel quantum devices for cooperative VQA training. To further constraint noise and speed-up convergence, we design a model for individual NISQ devices concerning their properties and running conditions, and propose a weighting mechanism for regularizing the returned gradients. Extensive evaluations on 10 IBM-Q quantum devices using the VQE example show that the distributive VQA training framework can substantially boost the training speed by 10.5x on average (up to 86x and at least 5.2x) with improved training accuracy.

Stein, Samuel A.↗

Distributed-Memory Parallel JointNMF

Joint Nonnegative Matrix Factorization (JointNMF) is a hybrid method for mining information from datasets that contain both feature and connection information. We propose distributed-memory parallelizations of three algorithms for solving the JointNMF problem based on Alternating Nonnegative Least Squares, Projected Gradient Descent, and Projected Gauss-Newton. We extend well-known communication-avoiding algorithms using a single processor grid case to our coupled case on two processor grids. We demonstrate the scalability of the algorithms on up to 960 cores (40 nodes) with 60% parallel efficiency. The more sophisticated Alternating Nonnegative Least Squares (ANLS) and Gauss-Newton variants outperform the first-order gradient descent method in reducing the objective on large-scale problems. We perform a topic modelling task on a large corpus of academic papers that consists of over 37 million paper abstracts and nearly a billion citation relationships, demonstrating the utility and scalability of the methods.

Eswar, Srinivas↗

Automatic identification and classification of Palomar Transient Factory astrophysical objects in GLADE

Palomar Transient Factory (PTF) is a comprehensive detection system for the identification and classification of transient astrophysical objects. In this paper, we make two significant contributions to the PTF pipeline. First, we present an experimental study that evaluates a novel implementation of the real-time classifier in GLADE - a parallel data processing system that combines the efficiency of a database with the extensibility of map-reduce. We show how each stage in the classifier maps optimally into GLADE tasks by taking advantage of the unique features of the system - range-based data partitioning, columnar storage, multi-query execution, and in-database support for complex aggregate computation. Second, we introduce a novel parallel similarity join algorithm for advanced transient classification. In conclusion, we implement this algorithm in GLADE and execute it on a massive supercomputer with more than 3,000 threads, achieving more than three orders of magnitude improvement over the PostgreSQL solution.

79 ASTRONOMY AND ASTROPHYSICS↗

Manufacturing conversion for energy efficiency

The Flambeau River Papers Manufacturing Conversion for Energy Efficiency Project has identified the following goals and objectives: 1. A low pressure accumulator tank will be installed to capture low pressure gases for reuse. The estimated cost is $\$$2.1 million with an energy savings of $\$$500,000 annually or enough natural gas savings to heat 590 average Wisconsin homes. 2. Replace the steam turbine and upgrade Paper Machine #3, the largest of Flambeau River Papers machines, at a cost of $\$$6.265 million. The result will save enough natural gas to heat 141 average homes, or about $\$$1.2-million each year. 3. Install a new cyclonic and cell fracturing technology dryer to reduce moisture in both sludge and biomass wastes. The estimated cost of this task is $\$$1.5-million with an annual energy savings of $\$$700,000. It will also eliminate all coal burning at Flambeau River Papers (7,200 tons of coal annually).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗