Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “range measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Discrete range clustering using Monte Carlo methods

For automatic obstacle avoidance guidance during rotorcraft low altitude flight, a reliable model of the nearby environment is needed. Such a model may be constructed by applying surface fitting techniques to the dense range map obtained by active sensing using radars. However, for covertness, passive sensing techniques using electro-optic sensors are desirable. As opposed to the dense range map obtained via active sensing, passive sensing algorithms produce reliable range at sparse locations, and therefore, surface fitting techniques to fill the gaps in the range measurement are not directly applicable. Both for automatic guidance and as a display for aiding the pilot, these discrete ranges need to be grouped into sets which correspond to objects in the nearby environment. The focus of this paper is on using Monte Carlo methods for clustering range points into meaningful groups. One of the aims of the paper is to explore whether simulated annealing methods offer significant advantage over the basic Monte Carlo method for this class of problems. We compare three different approaches and present application results of these algorithms to a laboratory image sequence and a helicopter flight sequence.

Chatterji, G. B.↗

GRAIL - A Microwave Ranging Instrument to Map Out the Lunar Gravity Field

Gravity Recovery and Interior Laboratory, or GRAIL, is a NASA mission to map out the gravity field of the moon to an unprecedented level of detail. The instrument for this mission is based on GRACE (Gravity Recovery and Climate Experiment), an earth-orbiting mission currently mapping out the gravity field of the earth. This paper will describe the similarities and differences between these two instruments with a focus on the microwave ranging measurements used to determine the gravity parameters and the testbed built at Jet Propulsion Laboratory to demonstrate micron level ranging capability. The onboard ultrastable oscillator and RF instruments will be described and noise contributions discussed.

Enzer, Daphna G.↗

Detection of the isotopes of heavy cosmic ray nuclei

A counter telescope designed to detect and resolve the isotopic composition of cosmic ray nuclei heavier than neon is being prepared. The telescope consists of a rather conventional charge measuring array using two scintillator elements and two solid Cerenkov radiators of differing refractive index. The mass measurement is obtained by combining the velocity information from one or both of the Cerenkov radiators operating near their threshold with residual range measured in a block of nuclear emulsion. Path length corrections and particle location in the emulsions is provided by a spark chamber fired in coincidence with potentially suitable particles. The telescope has a geometry factor of 530 sq cm sr roughly. It should be able to resolve the isotopes of iron over the energy range of 300 to 720 Mev/n and those of neon over 300 to 400 MeV/n. The expected response and characteristics of the telescope are described in detail and the sensitivity to rare isotopes discussed.

Gilman, C. M.↗

Nonlocal subpicosecond delay metrology using spectral quantum interference

Precise knowledge of position and timing information is critical to support elementary protocols such as entanglement swapping on quantum networks. While approaches have been devised to use quantum light for such metrology, they largely rely on time-of-flight (ToF) measurements with single-photon detectors and, therefore, are limited to picosecond-scale resolution owing to detector jitter. In this work, we demonstrate an approach to distributed sensing that leverages phase modulation to map changes in the spectral phase to coincidence probability, thereby overcoming the limits imposed by single-photon detection. By extracting information about the joint biphoton phase, we measure a generalized delay—the difference in signal–idler arrival, relative to local radio frequency (RF) phase modulation. For nonlocal ranging measurements, we achieve (2$σ$) precision of ±0.04 ps and for measurements of the relative RF phase, (2$σ$) precision of ±0.7°. We complement this fine timing information with ToF data from single-photon time-tagging to demonstrate absolute measurement of time delay. By relying on off-the-shelf telecommunications equipment and standard quantum resources, this approach has the potential to reduce overhead in practical quantum networks.

42 ENGINEERING↗

Structural alignment sensor

Comparative Michelson interferometers are discussed as well as the operating range potential of a structural alignment sensor (SAS) which requires only one laser mode. Schematics are presented for the distance measurement logic, the basic SAS system, the SAS optical layout, the coarse measurement signal processor, and the measured range resolution.

Davis, L.↗

Forced Diffusion Chamber Monitoring of Soil CO2 Fluxes from 2019 to Present at NGEE Arctic Teller Site, Mile Marker 27, Alaska

Soil CO2 efflux was monitored at the NGEE Arctic Teller Site, Mile Marker 27, in Alaska. Monitoring was performed beginning in June 2019 using EOSense forced diffusion soil CO2 flux sensors at up to six sites characterized by varying vegetation cover, topographic position, and soil temperature and moisture. Dataset includes measurements of soil CO2 flux and chamber temperature. Time interval between measurements ranges from 5 minutes to 3 hours. Included are EOSense chamber locations as *.kml and *.png files, six *.csv files with measurements, and two *.csv reporting format files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Electron beam fluorescence system to measure gas density in impulse facilities

Very rapid measurements, ranging from a few microsecond to milliseconds in duration, characterize studies made in shock regions or behind them. A system to measure gas density under such conditions in a 15.24-cm (6-in.) expansion tube is described. The basic elements are an electron beam of moderate energy and high current capability, an optical detector, and the associated electronics and data readout equipment. A heated-cathode electron gun, capable of pulsed operation and delivering up to 200 milliamperes current, provides the source of electrons. Optics include a simple collector lens, aperture, collimator lens, filters, and a photomultiplier tube. The photomultiplier output signal was recorded by means of photographed oscilloscope traces for pulsed beam operation.

Hoppe, J. C.↗

Some measured and calculated effects of forward velocity on propeller noise

Test flights using a twin-engine, high-wing, light STOL transport plane powered by free turbine engines driving three-bladed propellers, were conducted at the NASA Wallops Flight Center. A ground-based acoustic measuring range was set up, and aircraft tracking information was supplied by a radar system. The noise of the unshrouded propeller was measured under static and forward flight conditions, and the measurements were compared with theory. Under static conditions, the principal noise is related to the unsteady loading associated with the interaction of the propeller with persistent turbulent eddies passing through the propeller disk. Through the use of existing prediction techniques, it was shown that changes in the geometry such as different airfoil thickness distribution can affect the radiated acoustic pressure signatures. This test program confirmed that lower propeller noise levels are produced in forward flight than under static conditions and that the most significant reductions occur at the midfrequencies which dominate perceived and A-weighted noise levels.

Pegg, R. J.↗

Prospects for coherent lidar systems and technology development

A coherent lidar is a powerful technique for remote measurements of velocity fields, and at middle infrared wavelengths it also has advantages compared with direct-detection lidar in extended range measurement of atmospheric species. These qualities are obtained at the cost of additional complexity and more stringent requirements on the coherence properties of the lasers which are used. An attempt is made to summarize the technological requirements of certain coherent lidar applications and discuss relevant technology development, emphasizing the CO2 and solid-state laser components.

Menzies, Robert T.↗

Eliminating Signal Bias Caused by Vacuum System Backstreaming in the Diagnostic Residual Gas Analyzer of ITER

In fusion neutral gas analysis, such as with the Diagnostic Residual Gas Analyzer (DRGA) for ITER, the primary measurement range of interest comprises the low-amu species (1 to 6), especially deuterium and helium. The challenge in successfully obtaining accurate measurements is two-fold. First, the sensitivity of the method must be sufficient to resolve trace amounts accurately; typically, one percent or less. Second, the gas signal from the fusion processes must be free of bias caused by the latent presence (from system outgassing and/or vacuum backstreaming) of these gases to enable accurate interpretation of the measured signal. This latter criterion can be problematic for the lightest gases since there is a propensity for some fraction of the pumped gas load to undergo a phenomenon known as backstreaming. This behavior is manifested in pumping systems for gas properties related to relative atomic weight (lightest) and size (smallest). Backstreaming results in a significant amount of the pumped gas undertaking a reverse flow and re-entering the measurement region; thus, contaminating the forward, real-time measurement. To fully eliminate this adverse effect, a conductance-limiting device – or orifice – has been installed in the high-vacuum pumping system of the present ITER DRGA prototype. The system was already equipped with a secondary turbomolecular pump (TMP), but with limited effectiveness against backstreaming in the inter-pump volume (IPV). This orifice is placed within the suction inlet coupling of the secondary TMP, which is downstream of the IPV. Its objective is to eliminate the backstreaming phenomenon by increasing the back pressure in the IPV. However, the orifice sizing must take into consideration other factors, such as the diagnostic measurement objectives. For example, in the ITER DRGA, one of the measurement requirements is a dynamic response time of ~1s. Fortunately, an added benefit of the pumping restriction created by the orifice is that the upstream pressure increase is beneficial for the DRGA’s optical gas analysis (OGA) sensors. These sensors are attached to the IPV in the present design. The glow discharges, when used as an OGA light source, will typically have a brighter light emission with increasing plasma cell pressure. In addition to the fusion machine research sector, there are other potential applications of this pumping technique where the monitoring of lighter gas concentrations is essential, such as the photolithography process for the semiconductor fabrication of integrated circuits. This presentation will describe the vacuum system used to demonstrate a process to eliminate backstreaming as well as show test results to verify the accomplishment of this critical objective.

Marcus, Chris↗

Precision geodesy and geodynamics using Starlette laser ranging

The French Starlette satellite, launched in February 1975, was the first satellite specifically designed to minimize the effects of nongravitational forces and to obtain the highest possible accuracy for laser range measurements. It has been found that Starlette represents a valuable complement to the U.S. geodetic satellites. In an analysis of Starlette laser ranging data conducted by Marsh and Williamson (1978), it was concluded that by tailoring a gravity model to a specific satellite and observation period, substantial improvements in data fits and, therefore, in orbit accuracy could be achieved. In the present analyses, a tailored gravity model has been derived for Starlette from the data acquired for the 4-year period, 1975-1978. Attention is given to the solution for geodetic and geodynamic parameters and polar motion.

Marsh, J. G.↗

Differential sea-state bias: A case study using TOPEX/POSEIDON data

We used selected data from the NASA altimeter TOPEX/POSEIDON to calculate differences in range measured by the C and Ku-band altimeters when the satellite overflew 5 to 15 m waves late at night. The range difference is due to free electrons in the ionosphere and to errors in sea-state bias. For the selected data the ionospheric influence on Ku range is less than 2 cm. Any difference in range over short horizontal distances is due only to a small along-track variability of the ionosphere and to errors in calculating the differential sea-state bias. We find that there is a barely detectable error in the bias in the geophysical data records. The wave-induced error in the ionospheric correction is less than 0.2% of significant wave height. The equivalent error in differential range is less than 1% of wave height. Errors in the differential sea-state bias calculations appear to be small even for extreme wave heights that greatly exceed the conditions on which the bias is based. The results also improved our confidence in the sea-state bias correction used for calculating the geophysical data records. Any error in the correction must influence Ku and C-band ranges almost equally.

Stewart, Robert H.↗

Improved Measurement of Dispersion in an Optical Fiber

An improved method of measuring chromatic dispersion in an optical fiber or other device affords a lower (relative to prior such methods) limit of measurable dispersion. This method is a modified version of the amplitude-modulation (AM) method, which is one of the prior methods. In comparison with the other prior methods, the AM method is less complex. However, the AM method is limited to dispersion levels . 160 ps/nm and cannot be used to measure the symbol of the dispersion. In contrast, the present modified version of the AM method can be used to measure the symbol of the symbol of the dispersion and affords a measurement range from about 2 ps/nm to several thousand ps/nm with a resolution of 0.27 ps/nm or finer. The figure schematically depicts the measurement apparatus. The source of light for the measurement is a laser, the wavelength of which is monitored by an optical spectrum analyzer. A light-component analyzer amplitude-modulates the light with a scanning radio-frequency signal. The modulated light is passed through a buffer (described below) and through the device under test (e.g., an optical fiber, the dispersion of which one seeks to measure), then back to the light-component analyzer for spectrum analysis. Dispersion in the device under test gives rise to phase shifts among the carrier and the upper and lower sideband components of the modulated signal. These phase shifts affect the modulation-frequency component of the output of a photodetector exposed to the signal that emerges from the device under test. One of the effects is that this component goes to zero periodically as the modulation frequency is varied.

Huang, Shouhua↗

Conductance measurement circuit with wide dynamic range

A conductance measurement circuit to measure conductance of a solution under test with an output voltage proportional to conductance over a 5-decade range, i.e., 0.01 uS to 1000 uS or from 0.1 uS to 10,000 uS. An increase in conductance indicates growth, or multiplication, of the bacteria in the test solution. Two circuits are used each for an alternate half-cycle time periods of an alternate squarewave in order to cause alternate and opposite currents to be applied to the test solution. The output of one of the two circuits may be scaled for a different range optimum switching frequency dependent upon the solution conductance and to enable uninterrupted measurement over the complete 5-decade range. This circuitry provides two overlapping ranges of conductance which can be read simultaneously without discontinuity thereby eliminating range switching within the basic circuitry. A VCO is used to automatically change the operating frequency according to the particular value of the conductance being measured, and comparators indicate which range is valid and also facilitate computer-controlled data acquisition. A multiplexer may be used to monitor any number of solutions under test continuously.

Mount, Bruce E.↗

Lidar stratospheric ozone measurements at the observatoire de Haute Provence (France)

Strastospheric ozone monitoring is of particular importance to confirm present day theories predicting a maximal ozone depletion, due to chlorofluorocarbon emission, in the 35 to 45 km altitude range. Measurements presently rely on both ground based and satellite-borne passive experiments. Such systems have been recently shown to have intrinsic limitations mainly due to atmospheric aerosol presence and calibration problems. During the last few years, active lidar profiling of the ozone vertical distribution by the Differential Absorption Laser technique (DIAL) in the UV wavelength range has been developed using two different laser sources: a Nd-YAG pumped dye laser which enables a large tuning range of the UV emitted wavelengths; and exciplex laser sources using xenon chloride as an active medium and emitting at 308 nm, the off wavelength being usually generated by Raman shifting techniques. Advantages and limitations of using both of these systems are briefly discussed.

Godin, S.↗

Critical configurations (determinantal loci) for range and range difference satellite networks

The observational modes of Geometric Satellite Geodesy are discussed. The geometrical analysis of the problem yielded a regression model for the adjustment of the observations along with a suitable and convenient metric for the least-squares criterion. The determinantal loci (critical configurations) for range networks are analyzed. An attempt is made to apply elements of the theory of variants for this purpose. The use of continuously measured range differences for loci determination is proposed.

Tsimis, E.↗

The complete polarization state of a storm of millisecond bursts from Jupiter

Normal bursts with right-hand (RH) elliptical polarization, millisec S-bursts with RH elliptical polarization, and S-bursts with left-hand (LH) elliptical polarization, are presently observed in an extended storm of decametric radiation from Jupiter's Io-related source, 'Io-B'. This radiation was 100 percent elliptically polarized at all frequencies in the 14-31 MHz range measured. For an 80-min period, there was a mixture of RH and LH elliptically polarized S bursts in the 14-20 MHz range. An examination of the origin of a Faraday-rotation difference between RH and LH elliptical bursts suggests that some Faraday rotation occurs in the Io torus; this was traversed more centrally by the LH bursts from the southern auroral zone than the HH bursts from the northern auroral zone.

Dulk, G. A.↗

Improved Estimate of Phobos Secular Acceleration from MOLA Observations

We report on new observations of the orbital position of Phobos, and use them to obtain a new and improved estimate of the rate of secular acceleration in longitude due to tidal dissipation within Mars. Phobos is the inner-most natural satellite of Mars, and one of the few natural satellites in the solar system with orbital period shorter than the rotation period of its primary. As a result, any departure from a perfect elastic response by Mars in the tides raised on it by Phobos will cause a transfer of angular momentum from the orbit of Phobos to the spin of Mars. Since its discovery in 1877, Phobos has completed over 145,500 orbits, and has one of the best studied orbits in the solar system, with over 6000 earth-based astrometric observations, and over 300 spacecraft observations. As early as 1945, Sharpless noted that there is a secular acceleration in mean longitude, with rate (1.88 + 0.25) 10(exp -3) degrees per square year. In preparation for the 1989 Russian spacecraft mission to Phobos, considerable work was done compiling past observations, and refining the orbital model. All of the published estimates from that era are in good agreement. A typical solution (Jacobson et al., 1989) yields (1.249 + 0.018) 10(exp -3) degrees per square year. The MOLA instrument on MGS is a laser altimeter, and was designed to measure the topography of Mars. However, it has also been used to make observations of the position of Phobos. In 1998, a direct range measurement was made, which indicated that Phobos was slightly ahead of the predicted position. The MOLA detector views the surface of Mars in a narrow field of view, at 1064 nanometer wavelength, and can detect shadows cast by Phobos on the surface of Mars. We have found 15 such serendipitous shadow transit events over the interval from xx to xx, and all of them show Phobos to be ahead of schedule, and getting progressively farther ahead of the predicted position. In contrast, the cross-track positions are quite close to the predicted values. Assuming that the along-track discrepancy is small enough that we can linearize the corrections, we model the mean orbital longitude as a quadratic function of time, and solve for corrections to the constant, linear, and quadratic terms. The time span of the recent observations is insufficient to properly resolve this issue alone, but when the 127 years of prior observations are added, we find a solution which reduces misfit to the new observations considerably, and makes no significant change to the fit to earlier observations. Our estimate for the secular acceleration term is (1.367 + 0.006) degrees per square year. The corresponding rate of energy dissipation is 3.34 MW. From a geophysical perspective, a more interesting parameter than the secular acceleration itself is the tidal lag angle, or tidal quality factor Q, for Mars. Unfortunately, the limiting error source in that determination is remaining uncertainty in the tidal Love numbers at harmonic degrees 2,3, and even 4. Until those parameters are better constrained, improvement in the orbital model of Phobos will not provide corresponding benefits for understanding the interior of Mars.

Bills, Bruce↗