Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Integrated Biophysical Modeling and Image Analysis: Application to Neuro-Oncology

Central nervous system (CNS) tumors come with vastly heterogeneous histologic, molecular, and radiographic landscapes, rendering their precise characterization challenging. The rapidly growing fields of biophysical modeling and radiomics have shown promise in better characterizing the molecular, spatial, and temporal heterogeneity of tumors. Integrative analysis of CNS tumors, including clinically acquired multi-parametric magnetic resonance imaging (mpMRI) and the inverse problem of calibrating biophysical models to mpMRI data, assists in identifying macroscopic quantifiable tumor patterns of invasion and proliferation, potentially leading to improved (a) detection/segmentation of tumor subregions and (b) computer-aided diagnostic/prognostic/predictive modeling. This article presents a summary of (a) biophysical growth modeling and simulation,(b) inverse problems for model calibration, (c) these models' integration with imaging workflows, and (d) their application to clinically relevant studies. We anticipate that such quantitative integrative analysis may even be beneficial in a future revision of the World Health Organization (WHO) classification for CNS tumors, ultimately improving patient survival prospects.

60 APPLIED LIFE SCIENCES↗

A Review of Doses for Dental Imaging in 2010–2020 and Development of a Web Dose Calculator

Dental imaging is one of the most common types of diagnostic radiological procedures in modern medicine. We introduce a comprehensive table of organ doses received by patients in dental imaging procedures extracted from literature and a new web application to visualize the summarized dose information. We analyzed articles, published after 2010, from PubMed on organ and effective doses delivered by dental imaging procedures, including intraoral radiography, panoramic radiography, and cone-beam computed tomography (CBCT), and summarized doses by dosimetry method, machine model, patient age, and technical parameters. Mean effective doses delivered by intraoral, 1.32 (0.60–2.56) μSv, and panoramic, 17.93 (3.47–75.00) μSv, procedures were found to be about1% and 15% of that delivered by CBCT, 121.09 (17.10–392.20) μSv, respectively. In CBCT imaging, child phantoms received about 29% more effective dose than the adult phantoms received. The effective dose of a large field of view (FOV) (>150 cm2) was about 1.6 times greater than that of a small FOV (<50 cm2). The maximum CBCT effective dose with a large FOV for children, 392.2 μSv, was about 13% of theeffective dose that a person receives on average every year from natural radiation, 3110 μSv. Monte Carlo simulations of representative cases of the three dental imaging procedures were then conducted to estimate and visualize the dose distribution within the head. The user-friendly interactive web application (available at http://dentaldose.org) receives user input, such as the number of intraoral radiographs taken, and displays total organ and effective doses, dose distribution maps, and a comparison with other medical and natural sources of radiation. The web dose calculator provides a practical resource for patients interested in understanding the radiation doses delivered by dental imaging procedures.

Lee, Hawon↗

XRIPL

XRIPL is a library of tools for processing x-ray radiographs and extracting contours of interest within the image using computer vision techniques. Features include spatial calibration, denoising, background and attenuation correction through pseudo-flatfielding, watershed segmentation, contour processing, and visualization. The details of the XRIPL analysis pipeline are published in the Proceedings of the 23rd Topical Conference on High-Temperature Plasma Diagnostics Proceedings (LA-UR-20-30133) [1]. [1] P. M. Kozlowski, Y. Kim, B. M. Haines, H. F. Robey, T. J. Murphy, H. M. Johns, and T. S. Perry. Use of Computer Vision for analysis of image data sets from high temperature plasma experiments. Review of Scientific Instruments 92, 033532 (2021) https://doi.org/10.1063/5.0040285

Kozlowski, Pawel↗

TRINIDI (Time-of-Flight Resonance Imaging with Neutrons for Isotopic Density Inference)

This software is an open-source Python library that provides tools for processing hyperspectral neutron time-of-flight radiography data. This type of data allows material decomposed reconstructions to be generated with the use of material characteristic spectral responses and the algorithms provided in this code library. The software library will contain tools for pre-processing the neutron measurement data, estimating measurement system parameters, reconstructing material decomposed radiographs, and computing material decomposed computed tomography (CT). Furthermore, it will have capability to generate and process simulated neutron time-of-flight data with the goal of benchmarking and demonstrating the tools that are provided. The software will include thorough documentation and application examples.

Balke, Thilo↗

Imaging Bragg Edge Analysis TooLs for Engineering Structures (iBeatles)

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) provides pulsed neutrons with energies varying from epithermal to cold. In preparation for VENUS, the neutron imaging beamline to be located at beam port 10, we have performed a series of experiments focused on wavelength-dependent radiography and computed tomography for a broad range of applications, from materials science to biological tissues.One of the time-of-flight (TOF) techniques that is of interest to the scientific community is the 2-dimensional mapping of phases and average crystalline plane orientation in samples both ex-situ and during applied stresses such as tensile loading and heating. This technique is known as Bragg edgeimaging and relies on the identification of changes of transmission values, fitting of the edge to measure its displacement, and thus identify the shift in lattice parameter due to stresses. One of the challenges of TOF imaging measurements is the amount of data and the inability to observe Bragg edge shifts in real time during an experiment. Thus, we have been focusing on creating a Python-based interface that allows fast data processing and instantaneous mapping and fitting of the Bragg edges, and their evolution through time. Python libraries and Jupyter notebooks have been implemented to facilitate decision making during an experiment. The advantage of the notebooks is the possibility to guide an experiment as they can quickly process and display Bragg edge data. These notebooks can be used independently, or can be combined in a Python Graphical User Interface (GUI) tool called iBeatles. This interface permits visualization and fitting of the Bragg edges, and ultimately back-projects the fitting results onto the radiographs to display a strain map. Assuming data collection has sufficient statistics, the strain mapping analysis can be performed on a pixel-by-pixel basis. This development is a step forward toward a better user experience at the future VENUS beamline in terms of live feedback and productivity. Analysis that used to take days of switching between different applications can now be done in minutes within the

Bilheux, JeanChristophe [Oak Ridge National Labora↗

The 6-minute walk test predicts mortality in a pulmonary nontuberculous mycobacteria-predominant bronchiectasis cohort

Background: Bronchiectasis is a chronic lung condition frequently associated with nontuberculous mycobacteria pulmonary (NTM) disease. Persons with these conditions are at increased risk of mortality. Patient reported outcome (PRO) instruments and the 6-minute walk test (6MWT) have been shown to predict mortality for several lung conditions, but these measures have not been fully evaluated for bronchiectasis and NTM. Methods: We conducted a retrospective cohort study among adult patients enrolled in a natural history study of bronchiectasis at the National Heart, Lung, and Blood Institute. Electronic medical records were queried for demographic, clinical, microbiologic, radiographic, and PRO instrument data: St. George’s Respiratory Questionnaire (SGRQ), Medical Research Council Dyspnea Scale, and the Pulmonary Symptom Severity Score (PSSS). The study baseline date was defined as the patient’s first visit after January 1st, 2015 with a SGRQ or 6MWT completed. Follow-up was defined as the interval between the study baseline visit and date of death or December 31st, 2019. Sex-stratified Cox proportional-hazards regression was conducted to identify predictors of mortality. Separate models were run for each PRO and 6MWT measure, controlling for age, body mass index (BMI), fibrocavitary disease status, and M. abscessus infection. Results: In multivariable Cox proportional-hazards regression models, the PSSS-severity (aHR 1.29, 95% CI 1.04–1.59), the 6MWT total distance walked (aHR 0.938, 95% CI 0.896–0.981) and distance saturation product (aHR 0.930, 95% CI 0.887–0.974) independently predicted mortality. In addition, BMI was significantly predictive of mortality in all models. Conclusions: The 6MWT and a PRO instrument capturing symptom severity are independently predictive of mortality in our cohort of bronchiectasis patients.

6-minute walk test↗

Enhanced material identification via momentum-integrated muon scattering tomography

Cosmic ray muons, originating from interactions in the upper atmosphere, possess high energy and unique penetrative capabilities suitable for non-traditional radiographic inspection. This study explores their application in various fields such as nuclear fuel cask monitoring, nuclear reactor imaging, and archaeology, leveraging the principle of multiple Coulomb scattering for imaging dense materials. While muon scattering tomography has shown promise, accurately measuring muon momentum remains challenging. This research introduces the Momentum Integrated Point-of-Closest Approach (mPoCA) algorithm, integrating muon momentum data into the traditional Point-of-Closest Approach (PoCA) framework. Utilizing the Cherenkov muon spectrometer, renowned for precise muon momentum estimation, the mPoCA algorithm offers a novel imaging approach. Simulations conducted with GEANT4 evaluate the mPoCA algorithm’s performance against the standard PoCA method, demonstrating superior image resolution and enhanced material identification capabilities, particularly in distinguishing materials like uranium and lead. These findings underscore the potential of the mPoCA algorithm for advancing muon scattering tomography applications.

36 MATERIALS SCIENCE↗

Fresnel zone plate development for x-ray radiography of hydrodynamic instabilities at the National Ignition Facility

The study of Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high energy densities at the National Ignition Facility (NIF) requires high spatial resolution imaging. We demonstrate the potential of Fresnel zone plates (FZPs) to achieve resolution that would unlock such studies. FZPs are circular aperiodic gratings that use diffraction to focus x rays and produce an image with high spatial resolution. Taking into account the NIF’s challenging environment, we have designed a specific array of five FZPs for a zinc backlighter to take a radiograph of a target with 9 keV x rays. We measured a mean resolution for the FZP of 1.9µm±0.5µm and a ±1mm depth of focus at an x-ray calibration facility as well as a 2.3µm±0.4µm resolution on a resolution wire mesh shot on the NIF. We also performed an in-depth analysis of the image quality to assess the capability to resolve the small features present in RT and RM instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal focal spot characterization and modeling of the NIF ARC kilojoule picosecond laser

The advanced radiographic capability (ARC) laser system, part of theNational Ignition Facility (NIF) at Lawrence Livermore National Laboratory, is a short-pulse laser capability integrated into the NIF. The ARC is designed to provide adjustable pulse lengths of ~1–38 ps in four independent beamlets, each with energies up to 1 kJ (depending on pulse duration). A detailed model of the ARC lasers has been developed that predicts the time- and space-resolved focal spots on target for each shot. Measurements made to characterize static and dynamic wavefront characteristics of the ARC are important inputs to the code. Modeling has been validated with measurements of the time-integrated focal spot at the target chamber center (TCC) at low power, and the space-integrated pulse duration at high power, using currently available diagnostics. In this work, these simulations indicate that each of the four ARC beamlets achieves a peak intensity on target of up to a few 10 18 W=cm 2 .

47 OTHER INSTRUMENTATION↗

Plasma mirror focal spot quality for glass and aluminum mirrors for laser pulses up to 20 ps

High-intensity short-pulse lasers are being pushed further as applications continue to demand higher laser intensities. Uses such as radiography and laser-driven particle acceleration require these higher intensities to produce the necessary x-ray and particle fluxes. Achieving these intensities, however, is limited by the damage threshold of costly optics and the complexity of target chambers. This is evidenced by the Advanced Radiographic Capability (ARC) short-pulse laser at the National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory, producing four high-energy ≈1 kJ laser pulses at 30 ps pulse duration, being limited to an intensity of 10 18 W/cm 2 by the large focal spot size of ≈100 µm. Due to the setup complexity of NIF, changing the location of the final focusing parabola in order to improve the focal spot size is not an option. Therefore, this leads to the possible use of disposable ellipsoidal plasma mirrors (PMs) placed within the chamber, close to the target in an attempt to refocus the four ARC beams. However, the behavior of PMs at these relatively long pulse durations (tens of picoseconds) is not well characterized. The results from the COMET laser at the Jupiter Laser Facility carried out at 0.5 to 20 ps pulse durations on flat mirrors are presented as a necessary first step towards focusing curved mirrors. The findings show defocusing at longer pulse durations and higher intensities, with less degradation when using aluminum coated mirrors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MAD using INRAD and Radiography [Slides]

We have previously evaluated Intrinsic Radiation Detection Algorithms from vendors for the Department of Homeland Security. These algorithms have limited spectra capability due to both the relatively low spectral content of the signal due to the use of PVT in the Radiation Portal detectors as well as relatively simple algorithms which are based on energy windowing and other simple algorithms to perform classification of Special Nuclear Material. Current detection algorithms are suceptible to nuissance alarms due to Naturally Occuring Radiation (NORM) and variations in background suppression. In this work, we propose to fuse the intrinsic radiation and radiographic data in conjunction with well-established machine learning algorithms to developed enhanced Threat Object detection capability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Cherenkov Gamma Ray Detectors on High-Energy-Density Systems

Cherenkov gamma ray detectors are a valuable diagnostic technique for HED systems. Inertial confinement fusion is working towards high gain ignition. Gamma rays from ICF systems can help inform the degradation mechanisms preventing ignition: Carbon ablator is not being degraded, unlike the DT fuel; carbon γ timing can estimate shell energy during bangtime and may suggest hot spot cooling rate; and Cherenkov detectors are also used for high spatial and temporal resolution ICF mix studies on OMEGA. Cherenkov systems also inform energy spectrum of radiographic sources: ARC laser and Mercury pulsed power machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayes Inference Engine (BIE) Test Plan: TiltConeBeamCombo

The Bayes Inference Engine (BIE) is a general software tool intended to be used primarily in the analysis of radiographic data for density. An analysis is set up in the BIE by representing the problem as a collection of modules called glyphs. All glyphs to be used in creating the forward model of the experiment will be tested separately for a range of inputs. The testing of the adjoint code is performed in a separate document.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayes Inference Engine (BIE) Test Plan: TiltConeBeamComboDMLinear

The Bayes Inference Engine (BIE) is a general software tool intended to be used primarily in the analysis of radiographic data for density. An analysis is set up in the BIE by representing the problem as a collection of modules called glyphs. All glyphs to be used in creating the forward model of the experiment will be tested separately for a range of inputs.

97 MATHEMATICS AND COMPUTING↗

Bayes Inference Engine (BIE) Test Plan: TiltConeBeamComboDMGeometric

The Bayes Inference Engine (BIE) is a general software tool intended to be used primarily in the analysis of radiographic data for density. An analysis is set up in the BIE by representing the problem as a collection of modules called glyphs. All glyphs to be used in creating the forward model of the experiment will be tested separately for a range of inputs.

97 MATHEMATICS AND COMPUTING↗

Bayes Inference Engine (BIE) Test Plan: TiltConeBeamFVT

The Bayes Inference Engine (BIE) is a general software tool intended to be used primarily in the analysis of radiographic data for density. An analysis is set up in the BIE by representing the problem as a collection of modules called glyphs. All glyphs to be used in creating the forward model of the experiment will be tested separately for a range of inputs. The testing of the adjoint code is performed in a separate document.

97 MATHEMATICS AND COMPUTING↗

Q-6 DARHT Weather Enclosure Project Upgrades Design Review

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is adding a weather enclosure for the vessel area that will require the Detonation Science and Technology Group’s (Q-6) support for installing new cabling infrastructure to support capacitive discharge unit (CDU) firing operations and diagnostics. The requirement’s work scope is described in Q-6-TR-0034U*, Q-6 Support for the DARHT Weather Enclosure Upgrade Project, Customer Requirements Review (CRR).

42 ENGINEERING↗

DARHT Axis 1 Time-Resolved Injector Energy Measurement

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

47 OTHER INSTRUMENTATION↗