Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radioactive decay data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Biodistributions, Myelosuppression, and Toxicities in Mice Treated with an Anti-CD45 Antibody Labeled with the alpha-Emitting Radionuclides Bismuth-213 or Astatine-211

We previously investigated 213Bi-labeled anti-CD45 antibody to replace total body irradiation as conditioning for hematopoietic cell transplantation in a canine model. While this allowed sustained engraftment of marrow, limited availability and high cost of 213Bi led to a preliminary investigation in mice of 211At-labeled antibody for the same application. To gain an understanding of the differences between the two radionuclides, biodistribution and myelosuppression/toxicity studies were conducted with 213Bi- and 211At-labeled rat anti-murine CD45 antibody, 30F11, conjugates. After injecting mice with 2-50 μCi on 10 μg 30F11 conjugate or 20 μCi on 2 or 40 μg conjugate, biodistributions, myelosuppression and non-hematological toxicities were evaluated. Biodistribution studies showed that the spleen had the highest concentration of radioactivity, ranging from167-417 % injected dose/gram (%ID/g) at 24 h after injection in the 211At studies and 45-166 %ID/g at 3 h after injection in the 213Bi studies. The higher concentrations observed for 211At-labeled 30F11 was likely due to its longer half-life which, permitted more localization of antibody to the spleen before decay. 211At was more effective at myelosuppression for the same (mCi) quantity of injected radioactivity. Injection of only 20 or 50 μCi 211At resulted in lethal myeloablation. There was severe reversible acute hepatic toxicity with 50 μCi 213Bi, but not with lower doses or any dose of 211At. No significant renal toxicity occurred with either radionuclide. The data suggested that considerably lower quantities of 211At-labeled anti-CD45 antibody than 213Bi-labeled antibody might be effective for myelosuppression.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

2017 Status report-Tritium aging studies on stainless steel: Effect of hydrogen, tritium and decay helium on the fracture-toughness properties of stem, cup and block forgings

The materials of construction of tritium reservoirs are forged stainless steels. During service, the structural properties of the stainless steel change over time because of the diffusion of tritium into the reservoir wall and its radioactive decay to helium-3. This aging effect can cause cracks to initiate and grow which could result in a tritium leak or delayed failure of a tritium reservoir. Numerous factors affect the tendency for crack formation and propagation and are being investigated in this program. The goal of the research is to provide relevant fracture mechanics data that can be used by the design agencies in their assessments of tritium reservoir structural integrity. In this status report, new experimental results are presented on the effects of tritium and decay helium on the cracking properties of specimens taken from actual tritium reservoir forgings instead of the experimental forgings of past programs. The properties measured are more representative of actual reservoir properties because the microstructure of the specimens tested are more like that of the actual tritium reservoirs. The program was designed to measure the effects of material variables on tritium compatibility and includes two stainless steels (Type 304L and 316L stainless steel), multiple yield strengths (360-500 MPa), and multiple forging shapes (Stem, Cup, and Block).

36 MATERIALS SCIENCE↗

Neutrinoless double beta decay sensitivity of the XLZD rare event observatory

The XLZD collaboration is developing a two-phase xenon time projection chamber with an active mass of 60–80 t capable of probing the remaining weakly interacting massive particle-nucleon interaction parameter space down to the so-called neutrino fog. In this work we show that, based on the performance of currently operating detectors using the same technology and a realistic reduction of radioactivity in detector materials, such an experiment will also be able to competitively search for neutrinoless double beta decay in 136 Xe using a natural-abundance xenon target. XLZD can reach a 3σ discovery potential half-life of 5.7 × 10 27 years (and a 90% CL exclusion of 1.3 × 10 28 years) with 10 years of data taking, corresponding to a Majorana mass range of 7.3–31.3 meV (4.8–20.5 meV). XLZD will thus exclude the inverted neutrino mass ordering parameter space and will start to probe the normal ordering region for most of the nuclear matrix elements commonly considered by the community.

2-phase xenon TPCs↗

Cosmogenic production of 37 Ar in the context of the LUX-ZEPLIN experiment

We estimate the amount of 37 Ar produced in natural xenon via cosmic-ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth’s surface. We then calculate the resulting 37 Ar concentration in a 10-tonne payload (similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage, and delivery to the underground facility. Using the spallation model by Silberberg and Tsao, the sea-level production rate of 37 Ar in natural xenon is estimated to be 0.024 atoms/kg/day. Assuming the xenon is successively purified to remove radioactive contaminants in 1-tonne batches at a rate of 1 tonne/month, the average 37 Ar activity after 10 tons are purified and transported underground is 0.058 − 0.090 𝜇⁢Bq/kg, depending on the degree of argon removal during above-ground purification. Such cosmogenic 37 Ar will appear as a noticeable background in the early science data, while decaying with a 35-day half-life. This newly noticed production mechanism of 37 Ar should be considered when planning for future liquid-xenon-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-proton radioactivity and three-body decay. V. Improved momentum distributions

Nowadays quantum-mechanical theory allows one to reliably calculate the processes of 2p radioactivity (true three-body decays) and the corresponding energy and angular correlations up to distances of the order of 10{sup 3} fm. However, the precision of modern experiments has now become sufficient to indicate some deficiency of the predicted theoretical distributions. In this paper we discuss extrapolation along the classical trajectories as a method to improve the convergence of the theoretical energy and angular correlations at very large distances (of the order of atomic distances), where only long-range Coulomb forces are still operating. The precision of this approach is demonstrated using the 'exactly' solvable semianalytical models with simplified three-body Hamiltonians. It is also demonstrated that for heavy 2p emitters, the 2p decay momentum distributions can be sensitive to the effect of screening by atomic electrons. We compare theoretical results with available experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The BiPo detector for ultralow radioactivity measurements

The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in {sup 208}Tl and {sup 214}Bi for the SuperNEMO double beta decay source foils. A modular prototype called BiPo-1 with 0.8 m{sup 2} of sensitive surface area has been running in the Modane Underground Laboratory since February 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in {sup 208}Tl. After more than one year of background measurement a surface activity of the scintillators of A({sup 208}Tl) = 1.5 {mu}Bq/m{sup 2} is reported here.Given this level of background, a larger BiPo3 detector having 3.25 m{sup 2} of active surface area, will able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of A({sup 208}Tl)<3-4 {mu}Bq/kg(90% C.L.) with a six month measurement. This detector is actually under construction and will be installed in the Canfranc Underground Laboratory mid 2011.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for one-phonon mixed-symmetry states in the radioactive nucleus {sup 140}Nd

Low-spin excited states of {sup 140}Nd have been studied via the {sup 140}Ce({sup 3}He,3n){sup 140}Nd reaction. The data show that one of the candidates for the one-phonon mixed-symmetry state (MSS) of {sup 140}Nd, namely, the 2{sub 3}{sup +} state at 2140 keV with an effective lifetime of 220(90) fs, exhibits a fast M1 decay to the 2{sub 1}{sup +} state. Thus, this state can be considered, at least, as a fragment of the one-phonon MSS of {sup 140}Nd. This is the first example where mixed symmetry character is tentatively assigned to a state of an unstable nucleus from the mass A{approx_equal}140 region based on the data on absolute M1 transition rates. However, the data are not conclusive on whether this decay exhausts the total M1 strength or whether the one-phonon MSS of {sup 140}Nd is fragmented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Revealing Physical Activity of GRB Central Engine with Macronova/Kilonova Data

The modeling of Li-Paczyński macronova/kilonova signals gives a reasonable estimate on the neutron-rich material ejected during the neutron star mergers. Usually the accretion disk is more massive than the macronova ejecta, with which the efficiencies of converting the disk mass into prompt emission of three merger-driven GRBs can hence be directly constrained. Supposing the macronovae/kilonovae associated with GRB 050709, GRB 060614, and GRB 130603B arose from radioactive decay of the r -process material, the upper limit on energy conversion efficiencies are found to be as low as ∼10{sup −6}–10{sup −4}. Moreover, for all three events, neutrino annihilation is likely powerful enough to account for the brief gamma-ray flashes. Neutrino annihilation can also explain the “extended” emission lasting ∼100 s in GRB 050709, but does not work for the one in GRB 060614. These progresses demonstrate that the macronova can serve as a novel probe of the central engine activity.

79 ASTRONOMY AND ASTROPHYSICS↗

A lanthanide-rich kilonova in the aftermath of a long gamma-ray burst

Observationally, kilonovae are astrophysical transients powered by the radioactive decay of nuclei heavier than iron, thought to be synthesized in the merger of two compact objects. Over the first few days, the kilonova evolution is dominated by a large number of radioactive isotopes contributing to the heating rate. On timescales of weeks to months, its behaviour is predicted to differ depending on the ejecta composition and the merger remnant. Previous work has shown that the kilonova associated with gamma-ray burst 230307A is similar to kilonova AT2017gfo, and mid-infrared spectra revealed an emission line at 2.15 micrometres that was attributed to tellurium. Here, in this study, we report a multi-wavelength analysis, including publicly available James Webb Space Telescope data and our own Hubble Space Telescope data, for the same gamma-ray burst. We model its evolution up to two months after the burst and show that, at these late times, the recession of the photospheric radius and the rapidly decaying bolometric luminosity (L bol ∝ t −2.7±0.4 , where t is time) support the recombination of lanthanide-rich ejecta as they cool.

79 ASTRONOMY AND ASTROPHYSICS↗

Special Considerations for the Removal and Disposal of Micro-Reactor Experiments

Idaho National Laboratory (INL) is preparing to host several microreactor experiments through 2030 and beyond. Two new test beds currently under development will operate as microreactor or nuclear system experiment user facilities. Test bed experiments will be performed in series, with each nuclear experiment installed, operated, and removed before installation of the subsequent experiment. The necessarily brief transition period between experiments introduces unique equipment removal and radioactive waste disposal challenges. This paper evaluates equipment removal and radioactive waste management topics associated with tight sequencing of nuclear experiments and presents some of the solutions and approaches currently planned to meet these special considerations for one such experiment, the Molten Chloride Reactor Experiment (MCRE), slated for operation at INL’s Laboratory for Operation and Testing in the United States (LOTUS). The MCRE project is a collaboration between Southern Company Services, TerraPower, and INL, among others, to provide integral nuclear data that will advance molten salt fast reactor technology. MCRE will be the first critical fast-spectrum circulating fuel system ever operated and the first experiment operated in the LOTUS test bed. The experiment will nominally operate at zero power with planned low power excursions as part of operational planning for MCRE has been to minimize at-power operations to limit fission product formation while still achieving experimental objectives. After the experiment is complete, MCRE will be allowed to radioactively decay for a short period (nominally 90 days) prior to system defueling, flushing, removal, and disposal of all MCRE equipment, readying the test bed for the next nuclear experiment. Equipment removal and radioactive waste disposal have been integral to MCRE project planning since the Cooperative Research and Development Agreement was formalized in 2021. Due to requirements for future use of the test bed, the MCRE system, of necessity, must be removed in a much shorter time frame than typical for historic reactor decommissioning projects at INL. This results in minimal time for radioactive decay, resulting in not only elevated radiation dose rates but also the presence of short-to-medium-lived isotopes not typically encountered in the reactor decommissioning and radioactive waste management space. Additional unique constraints placed on the project include lack of intrinsic remote-operations capabilities in the test bed, space constraints in the test bed once MCRE has been installed, and contamination minimization requirements to return the test bed to as-found conditions to enable future use. This paper discusses planned solutions to these challenges. Approaches for implementing remote or semi-remote technologies in a non-hot cell environment with limited space availability are discussed. The paper also summarizes the systems engineering approach for concept development and design of equipment removal systems, which are being implemented concurrent with the MCRE design phase, providing feedback to system designers to incorporate features enabling efficient and safe equipment removal approaches. The timing of this paper at a relatively early phase of the project is meant to highlight the importance of early planning for nuclear system decommissioning while reactor design is ongoing to allow design feedback on componentry driven from decommissioning system needs. As new, innovative nuclear reactor technologies enter the nuclear market sector, reactor experiments are crucial for providing new integral nuclear data that establish safe operational margins for technology advancement. Microreactor experiments at INL will require safe, effective, and timely decommissioning approaches, which in turn require nuclear systems designed to expedite decommissioning. In addition to the advancement of nuclear reactor technologies, these nuclear experiments provide an opportunity to demonstrate, deploy, and test new removal and disposal capabilities to support the next generation of nuclear reactor technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-C-9A-04: Alternative Analytic Solution to the Paralyzable Detector Model to Calculate Deadtime and Deadtime Loss

Purpose: Some common methods to solve for deadtime are (1) dual-source method, which assumes two equal activities; (2) model fitting, which requires multiple acquisitions as source decays; and (3) lossless model, which assumes no deadtime loss at low count rates. We propose a new analytic alternative solution to calculate deadtime for paralyzable gamma camera. Methods: Deadtime T can be calculated analytically from two distinct observed count rates M1 and M2 when the ratio of the true count rates alpha=N2/N1 is known. Alpha can be measured as a ratio of two measured activities using dose calibrators or via radioactive decay. Knowledge of alpha creates a system with 2 equations and 2 unknowns, i.e., T and N1. To verify the validity of the proposed method, projections of a non-uniform phantom (4GBq 99mTc) were acquired in using Siemens SymbiaS multiple times over 48 hours. Each projection has >100kcts. The deadtime for each projection was calculated by fitting the data to a paralyzable model and also by using the proposed 2-acquisition method. The two estimates of deadtime were compared using the Bland-Altmann method. In addition, the dependency of uncertainty in T on uncertainty in alpha was investigated for several imaging conditions. Results: The results strongly suggest that the 2-acquisition method is equivalent to the fitting method. The Bland-Altman analysis yielded mean difference in deadtime estimate of ∼0.076us (95%CI: -0.049us, 0.103us) between the 2-acquisition and model fitting methods. The 95% limits of agreement were calculated to be -0.104 to 0.256us. The uncertainty in deadtime calculated using the proposed method is highly dependent on the uncertainty in the ratio alpha. Conclusion: The 2-acquisition method was found to be equivalent to the parameter fitting method. The proposed method offers a simpler and more practical way to analytically solve for a paralyzable detector deadtime, especially during physics testing.

07 ISOTOPE AND RADIATION SOURCES↗

Minimizing Backgrounds for the SuperCDMS SNOLAB Dark-Matter Experiment

Astronomical and cosmological observations indicate that large amounts of some slowly moving, unseen Dark Matter pervades the universe and outweighs normal matter by a factor of five. The Standard Model of Physics has no contender with the properties of this as-yet-undetected particle, so experimentalists build state-of-the-art radiation detectors to attempt to directly measure this Dark Matter. The Super Cryogenic Dark Matter Search (SuperCDMS) at Snolab is one such experiment, currently being constructed. This experiment uses ultra-cold, superconducting, high-purity silicon and germanium detectors to measure low-energy nuclear recoils from the elastic scattering of Dark Matter. I contributed to the calibration of the energy scale of low-energy nuclear recoils in CDMS II silicon detectors by computing an improved livetime correction for calibration data to verify the Monte Carlo rate normalization. Results indicate that the phonon collection efficiency of nuclear recoils relative to electron recoils is 95.2$^{+0.9}_{-0.7\%}$, and the ionization collection efficiency of low-energy nuclear recoils in silicon is lower than Lindhard prediction, consistent with other recent measurements. Backgrounds from the progeny decay of the abundant, naturally-occurring radioactive isotope radon-222 obstruct the sensitivity of essentially every dark-matter search. Radon concentrations in the Snolab cavern would contribute prohibitively large backgrounds if the volume surrounding the detectors were not purged with a low-flow low-radon gas. By measuring the radon diffusion and emanation, we identified acceptable gasket materials for sealing this radon purge, ensuring that the radon-induced backgrounds will be significantly lower than the other experimental backgrounds. A radon emanation system with a gas handling system and low-background radon detector was commissioned and used to measure the radon emanation of the proposed gaskets. A low-cost apparatus was constructed to measure the radon diffusion of gaskets with a commercial radon detector. The sensitivity of future generations of dark-matter detectors are expected to be dominated by long-lived low-energy beta- and alpha-emitting radon daughters such as 210 Pb on detector surfaces. I describe simulations indicating the detector could also be used to reduce background from material impurities plaguing rare-event searches, the commissioning of a prototype demonstration detector, and a gas handling system necessary to operate the detector. I demonstrated that the gas handling system reduces the otherwise dominant backgrounds by a factor of 62. This detector will therefore be able to detect 32 Si and 210 Pb 100 times better than currently available screeners.

Bowles, Michael A.↗

Review of Monte Carlo simulations for backgrounds from radioactivity

For all experiments dealing with the rare event searches (neutrino, dark matter, neutrino-less double-beta decay), the reduction of the radioactive background is one of the most important and difficult tasks. There are basically two types of background, electron recoils and nuclear recoils. The electron recoil background is mostly from the gamma rays through the radioactive decay. The nuclear recoil background is from neutrons from spontaneous fission, (α, n) reactions and muoninduced interactions (spallations, photo-nuclear and hadronic interaction). The external gammas and neutrons from the muons and laboratory environment, can be reduced by operating the detector at deep underground laboratories and by placing active or passive shield materials around the detector. The radioactivity of the detector materials also contributes to the background; in order to reduce it a careful screening campaign is mandatory to select highly radio-pure materials. In this review I present the status of current Monte Carlo simulations aimed to estimate and reproduce the background induced by gamma and neutron radioactivity of the materials and the shield of rare event search experiment. For the electromagnetic background a good level of agreement between the data and the MC simulation has been reached by the XENON100 and EDELWEISS experiments, using the GEANT4 toolkit. For the neutron background, a comparison between the yield of neutrons from spontaneous fission and (α, n) obtained with two dedicated softwares, SOURCES-4A and the one developed by Mei-Zhang-Hime, show a good overall agreement, with total yields within a factor 2 difference. The energy spectra from SOURCES-4A are in general smoother, while those from MZH presents sharp peaks. The neutron propagation through various materials has been studied with two MC codes, GEANT4 and MCNPX, showing a reasonably good agreement, inside 50% discrepancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical/ administrative options for managing tritium MCL exceedances in P-area groundwater and Steel Creek

This white paper was requested by the Core Team (United States Department of Energy [USDOE], United States Environmental Protection Agency [USEPA], and South Carolina Department of Health and Environmental Control [SCDHEC]) at the P-Area Groundwater (PAGW) Operable Unit (OU) Scoping Meeting held in January 2017 to discuss recent data and potential alternatives in support of a focused Corrective Measures Study/Feasibility Study (CMS/FS). This white paper presents an overview of the problem, and a range of technical and administrative options for addressing the tritium contamination in groundwater and Steel Creek. As tritium cannot be treated practicably, alternatives are limited to media transfer, containment and natural attenuation principally relying on radioactive decay. Using other groundwater OU decisions involving tritium as precedent, Savannah River Nuclear Solutions (SRNS) recommends that final tritium alternatives be evaluated in a CMS/FS, understanding that the likely preferred remedy will include natural attenuation with land use controls (LUCs). This is based on the inability to significantly reduce tritium impact to Steel Creek using an engineered solution as compared to natural attenuation. The timing of this evaluation could be conducted concurrently with the final remedy evaluation for volatile organic compounds (VOCs).

54 ENVIRONMENTAL SCIENCES↗

The CUORE cryostat: An infrastructure for rare event searches at millikelvin temperatures

The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO 2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130 Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of ~10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MCNP Intrinsic Source Constructor (MISC): A User’s Guide

The MCNP Intrinsic Source Constructor (MISC) facilitates the construction of MCNP source definition cards for radioactive materials. Given a material nuclide specification, either weight or atom fractions of those nuclides, and either a weight or atom density of the material, MISC will construct the source spectrum distribution of a specified particle type. MISC also calculates the absolute number of particles emitted per second per unit mass or volume. Furthermore, if decay chain information is available in the data sets selected by the user, the initial isotopes specified by the user can be approximately decayed to the resulting isotopes after a specified amount of time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Carbon isotopes in the ocean model of the Community Earth System Model (CESM1)

Carbon isotopes in the ocean are frequently used as paleoclimate proxies and as present-day geochemical ocean tracers. In order to allow a more direct comparison of climate model results with this large and currently underutilized data set, we added a carbon isotope module to the ocean model of the Community Earth System Model (CESM), containing the cycling of the stable isotope 13 C and the radioactive isotope 14 C. We implemented the 14 C tracer in two ways: in the "abiotic" case, the 14 C tracer is only subject to air–sea gas exchange, physical transport, and radioactive decay, while in the "biotic" version, the 14 C additionally follows the 13 C tracer through all biogeochemical and ecological processes. Thus, the abiotic 14 C tracer can be run without the ecosystem module, requiring significantly fewer computational resources. The carbon isotope module calculates the carbon isotopic fractionation during gas exchange, photosynthesis, and calcium carbonate formation, while any subsequent biological process such as remineralization as well as any external inputs are assumed to occur without fractionation. Given the uncertainty associated with the biological fractionation during photosynthesis, we implemented and tested three parameterizations of different complexity. Compared to present-day observations, the model is able to simulate the oceanic 14 C bomb uptake and the 13 C Suess effect reasonably well compared to observations and other model studies. Lastly, at the same time, the carbon isotopes reveal biases in the physical model, for example, too sluggish ventilation of the deep Pacific Ocean.

54 ENVIRONMENTAL SCIENCES↗