Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Designs and Modeling of Architect Multi-material Scintillator System

We present a new conceptual radiation detector, the Architected Multimaterial Scintillator System, that utilizes a scintillator composed of multiple materials arranged in architected structures to enable new capabilities. By structuring differently-dyed materials, the wavelength of the scintillation light encodes additional information in radiation measurements. These structures can be realized through additive manufacture (3D-printing). Two classes of this concept are described and modelled using Monte Carlo simulations to evaluate their performance. The first detector design uses dye microstructures to encode particle tracking information, allowing for directional neutron detection and gamma/neutron discrimination. The second design uses a dye gradient to indicate the position of radiation along the gradient. The simulation results indicate this new concept in radiation detection can achieve strong performance in a variety of capabilities including particle identification, directionality and spectroscopy measurements, and particle position reconstruction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Carbon-13 Radiofrequency Amplification by Stimulated Emission of Radiation of the Hyperpolarized Ketone and Hemiketal Forms of Allyl [1- 13 C]Pyruvate

13 C hyperpolarized pyruvate is an emerging MRI contrast agent for sensing molecular events in cancer and other diseases with aberrant metabolic pathways. This metabolic contrast agent can be produced via several hyperpolarization techniques. Despite remarkable success in research settings, widespread clinical adoption faces substantial roadblocks because the current sensing technology utilized to sense this contrast agent requires the excitation of 13 C nuclear spins that also need to be synchronized with MRI field gradient pulses. Here, we demonstrate sensing of hyperpolarized allyl [1- 13 C]pyruvate via the stimulated emission of radiation that mitigates the requirements currently blocking broader adoption. Specifically, 13 C Radiofrequency Amplification by Stimulated Emission of Radiation ( 13 C RASER) was obtained after pairwise addition of parahydrogen to a pyruvate precursor, detected in a commercial inductive detector with a quality factor (Q) of 32 for sample concentrations as low as 0.125 M with 13 C polarization of 4%. Moreover, parahydrogen-induced polarization allowed for the preparation of a mixture of ketone and hemiketal forms of hyperpolarized allyl [1- 13 C]pyruvate, which are separated by 10 ppm in 13 C NMR spectra. This is a good model system to study the simultaneous 13 C RASER signals of multiple 13 C species. This system models the metabolic production of hyperpolarized [1- 13 C]lactate from hyperpolarized [1- 13 C]pyruvate, which has a similar chemical shift difference. Our results show that 13 C RASER signals can be obtained from both species simultaneously when the emission threshold is exceeded for both species. On the other hand, when the emission threshold is exceeded only for one of the hyperpolarized species, 13 C stimulated emission is confined to this species only, therefore enabling the background-free detection of individual hyperpolarized 13 C signals. Furthermore, the reported results pave the way to novel sensing approaches of 13 C hyperpolarized pyruvate, potentially unlocking hyperpolarized 13 C MRI on virtually any MRI system–an attractive vision for the future molecular imaging and diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Alpha Spectrometry Results for Groundwater Samples Collected in Northern Iraq and a Summary of the Environmental Setting of the Adaya Burial Site

The Radiation Protection Center (RPC) of the Iraqi Ministry of Environment continues to evaluate the potential health impacts associated with the Adaya Burial Site, which is located 33 kilometers (20.5 miles) southwest of Mosul. This report documents the radiological analyses of 16 groundwater samples collected from wells located in the vicinity of the Adaya Burial Site and at other sites in northern Iraq. The Adaya Burial Site is a high-risk dump site because a large volume of radioactive material and contaminated soil is located on an unsecure hillside above the village of Tall ar Ragrag. The uranium activities for the 16 water samples in northern Iraq are considered to be naturally occurring and do not indicate artificial (man-made) contamination. With one exception, the alpha spectrometry results for the 16 wells that were sampled in 2019 indicate that the water quality concerning the three uranium isotopes (Uranium-233/234, Uranium-235/236, and Uranium-238) was acceptable for potable purposes (drinking and cooking). However, Well 7 in Mosul had a Uranium-233/234 activity concentration that slightly exceeded the World Health Organization guidance level. Eight of the 16 wells are located in the villages of Tall ar Ragrag and Adaya and had naturally occurring uranium concentrations. Wells in the villages of Tall ar Ragrag and Adaya are located near the Adaya Burial Site and should be sampled on an annual schedule. The list of groundwater analytes should include metals, total uranium, isotopic uranium, gross alpha/beta, gamma spectroscopy, organic compounds, and standard water quality parameters. Our current understanding of the hydrogeologic setting in the vicinity of the Adaya Burial Site is solely based on villager's domestic wells, topographic maps, and satellite imagery. To better understand the hydrogeologic setting, a Groundwater Monitoring Program needs to be developed and should include the installation of twelve groundwater monitoring wells in the vicinity of Tall ar Ragrag and the Adaya Burial Site. Characterization of the limestone aquifer and overlying alluvium is needed. RPC should continue to support health assessments for the villagers in Tall ar Ragrag and Adaya. Collecting samples for surface water (storm water), airborne dust, vegetation, and washway sediment should be conducted on a routine basis. Human access to the Adaya Burial Site needs to be strictly limited. Livestock access on or near the burial site needs to be eliminated. The surface-water exposure pathway is likely a greater threat than the groundwater exposure pathway. Installation of a surface-water diversion or collection system is recommended in order to reduce the potential for humans and livestock to come in contact with contaminated water and sediment. To reduce exposure to villagers, groundwater treatment should be considered if elevated uranium or other contaminants are detected in drinking water. Installing water-treatment systems would likely be quicker to accomplish than remediation and excavation of the Adaya Burial Site. The known potential for human exposure to uranium and metals (such as arsenic, chromium, selenium, and strontium) at the Adaya Burial Site is serious. Additional characterization , mitigation, and remediation efforts should be given a high priority.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Data trustworthiness signatures for nuclear reactor dynamics simulation

With the increased reliance on digitization in industrial control systems, the need for effective monitoring techniques has risen dramatically. Specifically, there is now a growing concern about the so-called false data injection (FDI) attacks. These attacks aim to alter the raw sensors’ data to cause malicious outcomes. Any serious FDI algorithm is based on an intimate knowledge of the system and its associated physics models, which renders conventional outlier/anomaly detection techniques almost obsolete in the face of such attacks. Thus, a critical need has emerged to develop a new class of defense methods that are capable of detecting FDI attacks under the assumption that the attacker has a strong familiarity with the system and its physics modeling. This class of defense methods are denoted by model-based defenses which are premised on the assumption that the attacker, while having a good understanding of the system, does not have full privileged access to all proprietary data and historical records of operation. However, (s)he is assumed to be capable of learning system behavior using self-learning techniques during an initial lie-in-wait period. To defend against this scenario, we propose a new model-based randomized window algorithm that searches time-series data for signatures that can serve as classifiers between normal and FDI scenarios. The classifiers are based on the correlations between the dominant degrees of freedom (DOFs) and the less-dominant DOFs (expected to be very sensitive to the system details that are unknown to the attacker). For demonstration, RELAP5 models are employed to calculate representative nuclear reactor behavior during a number of transient scenarios. Finally, falsified data are injected into the RELAP5-simulated behavior, and the proposed signature-identification algorithm is employed to detect the injected data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Computational Imaging for Intelligence in Highly Scattering Aerosols (Final Report)

Natural and man-made degraded visual environments pose major threats to national security. The random scattering and absorption of light by tiny particles suspended in the air reduces situational awareness and causes unacceptable down-time for critical systems and operations. To improve the situation, we have developed several approaches to interpret the information contained within scattered light to enhance sensing and imaging in scattering media. These approaches were tested at the Sandia National Laboratory Fog Chamber facility and with tabletop fog chambers. Computationally efficient light transport models were developed and leveraged for computational sensing. The models are based on a weak angular dependence approximation to the Boltzmann or radiative transfer equation that appears to be applicable in both the moderate and highly scattering regimes. After the new model was experimentally validated, statistical approaches for detection, localization, and imaging of objects hidden in fog were developed and demonstrated. A binary hypothesis test and the Neyman-Pearson lemma provided the highest theoretically possible probability of detection for a specified false alarm rate and signal-to-noise ratio. Maximum likelihood estimation allowed estimation of the fog optical properties as well as the position, size, and reflection coefficient of an object in fog. A computational dehazing approach was implemented to reduce the effects of scatter on images, making object features more readily discernible. We have developed, characterized, and deployed a new Tabletop Fog Chamber capable of repeatably generating multiple unique fog-analogues for optical testing in degraded visual environments. We characterized this chamber using both optical and microphysical techniques. In doing so we have explored the ability of droplet nucleation theory to describe the aerosols generated within the chamber, as well as Mie scattering theory to describe the attenuation of light by said aerosols, and correlated the aerosol microphysics to optical properties such as transmission and meteorological optical range (MOR). This chamber has proved highly valuable and has supported multiple efforts inclusive to and exclusive of this LDRD project to test optics in degraded visual environments. Circularly polarized light has been found to maintain its polarization state better than linearly polarized light when propagating through fog. This was demonstrated experimentally in both the visible and short-wave infrared (SWIR) by imaging targets made of different commercially available retroreflective films. It was found that active circularly polarized imaging can increase contrast and range compared to linearly polarized imaging. We have completed an initial investigation of the capability for machine learning methods to reduce the effects of light scattering when imaging through fog. Previously acquired experimental long-wave images were used to train an autoencoder denoising architecture. Overfitting was found to be a problem because of lack of variability in the object type in this data set. The lessons learned were used to collect a well labeled dataset with much more variability using the Tabletop Fog Chamber that will be available for future studies. We have developed several new sensing methods using speckle intensity correlations. First, the ability to image moving objects in fog was shown, establishing that our unique speckle imaging method can be implemented in dynamic scattering media. Second, the speckle decorrelation over time was found to be sensitive to fog composition, implying extensions to fog characterization. Third, the ability to distinguish macroscopically identical objects on a far-subwavelength scale was demonstrated, suggesting numerous applications ranging from nanoscale defect detection to security. Fourth, we have shown the capability to simultaneously image and localize hidden objects, allowing the speckle imaging method to be effective without prior object positional information. Finally, an interferometric effect was presented that illustrates a new approach for analyzing speckle intensity correlations that may lead to more effective ways to localize and image moving objects. All of these results represent significant developments that challenge the limits of the application of speckle imaging and open important application spaces. A theory was developed and simulations were performed to assess the potential transverse resolution benefit of relative motion in structured illumination for radar systems. Results for a simplified radar system model indicate that significant resolution benefits are possible using data from scanning a structured beam over the target, with the use of appropriate signal processing.

58 GEOSCIENCES↗

Event Response and Criticality Alarm Systems [Slides]

The smallest accident, in terms of fission yield and dose rate, that a criticality alarm system is required to detect. Need for a CAS shall be evaluated for all activities in which the inventory in individual unrelated areas exceeds 700g U-235, 500g U-233, 450 g Pu-239 OR 450g of any combination of these three isotopes. Unique configurations exist such that critical mass requirements may be less than the limits noted above.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volume 4: Detection Systems and Ultra-Cold Neutrons

As part of the Sustaining and Enhancing Nuclear Science (SENSe) initiative at Oak Ridge National Laboratory (ORNL), the prospect of adding new detection systems to support High Flux Isotope Reactor (HFIR) operations and to advance scientific research has prompted many ideas and discussions regarding potential features, configurations, locations, and applications. A working group of ORNL staff members was organized to further develop the concepts and recommending one or more configurations to best support future HFIR operations and scientific capacities and to provide order-of-magnitude cost estimates and timing. The areas of investigation included fast access detection systems, non-scattering beamline instruments, shielded detection instruments, and an ultracold neutron source. In each case, the focus was to develop world leading capabilities that would be unmatched by any other facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

It’s Not What You Take Up, It’s What You Keep: How Discoveries from Diverse Disciplines Directed the Development of the FDG PET/CT Scan

Although imaging glucose metabolism with positron emission tomography combined with X-ray CT (FDG-PET/CT) has become a standard diagnostic modality for the discovery and surveillance of malignant tumors and inflammatory processes, its origins extend back to more than a century of notable discoveries in the fields of inorganic and organic chemistry, nuclear physics, mathematics, biochemistry, solute transport physiology, metabolism, and imaging, accomplished by pioneering and driven investigators, of whom at least ten were recipients of the Nobel Prize. These tangled and diverse roots eventually coalesced into the FDG-PET/CT method, that through its many favorable characteristics inherent in the isotope used ( 18 F), the accurate imaging derived from coincidence detection of positron annihilation radiation combined with computed tomography, and the metabolic trapping of 2-deoxy-2-[ 18 F] fluoro-d-glucose (FDG) in tissues, provides safety, sensitivity, and specificity for tumor and inflammation detection. Here, the authors hope that this article will increase the appreciation among its readers of the insight, creativity, persistence, and drive of the many investigators who made this technique possible. This article is followed by a review of the many applications of FDG-PET/CT to the gastrointestinal tract and hepatobiliary system (Mandelkern in Dig Dis Sci 2022)

2-DG↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Can the GPM IMERG Final Product Accurately Represent MCSs’ Precipitation Characteristics over the Central and Eastern United States?

Mesoscale convective systems (MCSs) play an important role in water and energy cycles as they produce heavy rainfall and modify the radiative profile in the tropics and midlatitudes. An accurate representation of MCSs’ rainfall is therefore crucial in understanding their impact on the climate system. The V06B Integrated Multisatellite Retrievals from Global Precipitation Measurement (IMERG) half-hourly precipitation final product is a useful tool to study the precipitation characteristics of MCSs because of its global coverage and fine spatiotemporal resolutions. However, errors and uncertainties in IMERG should be quantified before applying it to hydrology and climate applications. This study evaluates IMERG performance on capturing and detecting MCSs’ precipitation in the central and eastern United States during a 3-yr study period against the radar-based Stage IV product. The tracked MCSs are divided into four seasons and are analyzed separately for both datasets. IMERG shows a wet bias in total precipitation but a dry bias in hourly mean precipitation during all seasons due to the false classification of nonprecipitating pixels as precipitating. These false alarm events are possibly caused by evaporation under the cloud base or the misrepresentation of MCS cold anvil regions as precipitating clouds by the algorithm. IMERG agrees reasonably well with Stage IV in terms of the seasonal spatial distribution and diurnal cycle of MCSs precipitation. A relative humidity (RH)-based correction has been applied to the IMERG precipitation product, which helps reduce the number of false alarm pixels and improves the overall performance of IMERG with respect to Stage IV.

54 ENVIRONMENTAL SCIENCES↗

J-GEM optical and near-infrared follow-up of gravitational wave events during LIGO’s and Virgo’s third observing run

The Laser Interferometer Gravitational-wave Observatory Scientific Collaboration and Virgo Collaboration (LVC) sent out 56 gravitational-wave (GW) notices during the third observing run (O3). The Japanese Collaboration for Gravitational wave ElectroMagnetic follow-up (J-GEM) performed optical and near-infrared observations to identify and observe an electromagnetic (EM) counterpart. We constructed a web-based system that enabled us to obtain and share information on candidate host galaxies for the counterpart, and the status of our observations. Candidate host galaxies were selected from the GLADE catalog with a weight based on the 3D GW localization map provided by LVC. We conducted galaxy-targeted and wide-field blind surveys, real-time data analysis, and visual inspection of observed galaxies. We performed galaxy-targeted follow-ups to 23 GW events during O3, and the maximum probability covered by our observations reached 9.8%. Among these, we successfully started observations for 10 GW events within 0.5 days after the detection. This result demonstrates that our follow-up observation has the potential to constrain EM radiation models for a merger of binary neutron stars at a distance of up to ~100 Mpc with a probability area of ≤ 500 deg 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gravitational waves from more attractive dark binaries

Abstract The detection of gravitational waves (GWs) has led to a deeper understanding of binaries of ordinary astrophysical objects, including neutron stars and black holes. In this work, we point out that binary systems may also exist in a dark sector with astrophysical-mass macroscopic dark matter. These “dark binaries”, when coupled to an additional attractive long-range dark force, may generate a stochastic gravitational wave background (SGWB) with a characteristic spectrum different from ordinary binaries. We find that the SGWB from planet-mass dark binaries is detectable by space- and ground-based GW observatories. The contribution to the SGWB today is smaller from binaries that merge before recombination than after, avoiding constraints on extra radiation degrees of freedom while potentially leaving a detectable GW signal at high frequencies up to tens of GHz.

Astronomy & Astrophysics↗

Integration of Nuclear Material Accounting Data and Process Monitoring Data for Improvement on Detection Probability in Safeguarding Electrochemical Processing Facilities (Final Technical Report)

The KAERI advanced spent fuel conditioning process (ACP) process is a critical component of the US- South Korean nuclear cooperation and the following “123 Agreement.” Its development has received considerable attention in both countries. The ACP is an electrochemical processing (pyroprocessing) that recycles over 96% of the used nuclear fuel (UNF). It is also intrinsically proliferation-resistant in theory. In normal operation, the U/TRU product is very hot radiologically. In addition, the Cm provides a high level of spontaneous neutrons, making the product unsuitable for weapon use. However, as pointed in some study, “the need for safeguards to protect against the diversion and misuse of separated plutonium applies essentially equally to all grades of plutonium.” As pointed by many studies, the well-established traditional Nuclear Material Accounting (NMA) approach cannot be directly applied to electrochemical processing because of the lack of an input accountability tank, the non-continuous material flow, and the unsatisfactory level of confidence in sampling methods. Therefore, nuclear safeguards remain a grand challenge in the developing of commercial electrochemical separations facilities, especially around the heart of such facilities, the electrorefiner (ER) systems. In contrast to NMA data, process monitoring (PM) data is normally an indirect measurement of the SNM and is acquired much more frequently. In a broad sense, PM includes monitoring by various types of equipment, e.g. radiation detectors, cameras, voltage, current sensors. Because it is already being collected by the operator, the additional cost to safeguards is low. It has long been believed that PM data can supplement NMA data and help improve safeguards, although the benefits are hard to quantify. The U.S. DOE’s Material Protection, Accounting, and Control Technology (MPACT) campaign has made substantial investments into innovative PM sensor technology and predictive model development for real- or near real-time measurement and prediction of molten salt density and level, salt composition and actinide concentration especially Pu, the cell voltage, and the cell current to supplement traditional NMA. For aqueous-based reprocessing facilities, it is reported that PM, integrated with traditional NMA, have a high detection probability for specific diversions. For electrochemical reprocessing, preliminary studies have shown that PM data can support traditional NMA in various ways by providing a basis to estimate some of the in-processing nuclear material inventories. Despite early success, further studies on fusion of PM data and NMA data are still needed, which is the goal of this proposed work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparative Performance Evaluation of Large Language Models for Extracting Molecular Interactions and Pathway Knowledge

Understanding the interactions and regulatory relationships among biomolecules is essential for deciphering complex biological systems and elucidating the mechanisms behind diverse biological functions. Traditionally, the collection of such molecular interaction data has relied on expert curation, a process that is both time-consuming and labor-intensive. To address these limitations, this study explores the use of large language models (LLMs) to automate the genome-scale extraction of molecular interaction knowledge. Here, we evaluate the performance of various LLMs on key biological tasks, including the identification of protein-protein interactions, detection of genes associated with pathways influenced by low-dose radiation, and inference of gene regulatory relationships. Our findings demonstrate that larger LLMs tend to perform better, particularly in extracting intricate gene and protein interactions. Despite their strengths, these models face challenges in recognizing functionally diverse gene groups and highly correlated regulatory relationships. Through a comprehensive analysis using established molecular interaction and pathway databases, we show that LLMs possess the potential to identify relevant biomolecules and predict their interactions, offering valuable insights and marking a significant step toward AI-driven biological knowledge discovery.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Investigation of cosmic ray impact on transmon qubits with different materials through fast decay detection at Fermilab’s SQMS laboratory

Noise sources affecting superconducting qubits, such as cosmic rays and ambient gamma radiation, have garnered attention for their potential impact. These radiations deposit energy in the qubit's substrate, generating high-energy phonons that break Cooper pairs, leading to the formation of quasi-particles. When these quasi-particles tunnel across Josephson junctions, they induce qubit de-excitation, causing relaxation errors. In this study, we employ a fast feedback mechanism for performing qubit reset to detect decay events with high time resolution. This capability along with frequency multiplexed readout allows us to explore error correlations across time and space. Transmon qubits, manufactured within the Superconducting Quantum Materials and Systems (SQMS) center [1], are investigated at the above-ground lab. We study the impact of cosmic rays on qubits with different encapsulations, geometries, and locations on the same or different chips. We present preliminary findings and discuss the implications for the performance of contemporary quantum hardware.

Roy, Tanay↗