Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A Scalable Hardware-and-Human-in-the-Loop Grid-interactive Efficient Building Equipment Performance Dataset

This project developed a publicly available, high-fidelity dataset about the interactions among humans, homes, and heat pumps supporting grid interactive efficient buildings to balance demand on the grid with comfort for occupants. Laboratory measurements and simulations of the hardware capture the second-scale electric power dynamics of heat pumps providing grid services like load shifting and load shedding. Field measurements, behavior tracking, and qualitative surveys of people in their homes over multiple years—including experimentally adjusting the heating and cooling system to provide grid services—to capture the reciprocal effect of human behavior on grid services, and grid services on human comfort. Taken together, these data capture the complete Hardware and Human in the loop system for residential heat pumps, reducing large uncertainties in simulation for design, and models for control of heat pumps, and grid-interactive buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Theory of one-element pumps for propulsion

A basic theory for one-element propulsion pumps is developed. A limit to the obtainable efficiency is established and relationships among pump-performance parameters that result in the greatest efficiency are indicated. It is shown that the peripheral velocity of the pump is directly related to ship speed and some relationships between performance parameters and pump geometry are developed. Mathematical models of pump performance are included.

Levy, J.↗

ComStock Measure Scenario Documentation: Laboratory-Informed Modeling of Standard Performance Heat Pump Rooftop Units

This measure scenario replaces gas and electric resistance RTUs in the U.S. commercial building stock with standard efficiency commercial off the shelf heat pump rooftop units. This study uses performance data informed by NREL laboratory testing of a standard efficiency 7.5-ton heat pump RTU. This is the key distinction between this measure scenario and a similar ComStock measure scenario - Standard Performance Heat Pump Rooftop Units - that uses published manufacturer data tables to inform performance. These two scenarios are compared in this report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficient supercritical water desalination using a high-temperature heat pump: A zero liquid discharge desalination

Supercritical water desalination (SCWD) is zero liquid discharge technology that can potentially control the solubility of different electrolytes. However, SCWD is an energy-intensive process and requires high-quality thermal heat (> 450 °C). This study proposes the integration of a high-temperature heat pump to reduce the SCWD energy requirement. The integrated system energy consumption improves by 36% for 3.5% feed concentration and 14% for 20% feed, and the distillate cost reduces by 15% and 10%. Another benefit of the proposed integration is the system can be operated using only electricity as a heat source, as is the case with commonly used high-recovery thermal desalination technology. The integrated SCWD-heat pump system shows superior performance compared to the commercially used brine concentrator and crystallizer system. It is approximately 20% more energy-efficient for 25% feed concentration and 8% cheaper. Hence, the integrated SCWD-heat pump has the potential to outperform the pre-existing high-recovery desalination technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quadratic strong coupling in AlN Kerr cavity solitons

Photonic platforms with χ (2) nonlinearity offer new degrees of freedom for Kerr frequency comb development. Here, we demonstrate Kerr soliton generation at 1550 nm with phase-matched quadratic coupling to the 775 nm harmonic band in a single AlN microring and thus the formation of dual-band mode-locked combs. In the strong quadratic coupling regime where the χ (2) phase-matching window overlaps the pump mode, the pump-to-harmonic-comb conversion efficiency is optimized. However, the strong quadratic coupling also drastically modifies the Kerr comb generation dynamics and decreases the probability of soliton generation. By engineering the χ (2) phase-matching wavelength, we are able to achieve a balance between high conversion efficiency and high soliton formation rate under the available pump power and microring quality factors. Our numerical simulations confirm the experimental observations. These findings provide guidance on tailoring single-cavity dual-band coherent comb sources.

Gong, Zheng (ORCID:0000000301704870)↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Qualification and Commissioning of Helium Flow Loop Experiment for Blanket Design Measurements

Sufficient cooling of plasma-facing materials remains an outstanding challenge in the design of fusion reactor blankets in commercial power demonstration plants. Due to its chemical inertness and low neutron interaction cross section, pressurized helium is a candidate coolant fluid for such systems; however, helium has a small thermal mass compared to liquid coolants, potentially reducing heat removal performance. To address this need, a number of heat transfer enhancements have been proposed to improve the cooling efficiency of such components, thereby decreasing pumping power needs and improving overall plant efficiency. Toward this end, a helium flow loop experiment (HFLE) has been designed and commissioned to test advanced passive heat transfer enhancements in unit-cell test sections, providing necessary data for model validation and subsequent system design. The HFLE is designed to provide flow of pressurized (up to 4 MPa) helium at flow rates up to 80 g/s, enabling heat transfer and pressure drop measurements in test pieces at Reynolds numbers in excess of 180 000. To explore the effects of novel and complex heat transfer enhancements, test sections are produced via additive manufacturing, providing geometries not typically obtainable by conventional machining. Here in this work, we present results from HFLE commissioning and the initial thermal-hydraulic tests of an additively manufactured rifled-rib test section. Results are compared to smooth pipe correlations, and plans are described for future HFLE measurements. These preliminary experiments indicate the utility of the HFLE for heat transfer enhancement testing and simulation validation activities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lasing characteristics of ZrO{sub 2} − Y{sub 2}O{sub 3} − Ho{sub 2}O{sub 3} crystals pumped by a Tm : LiYF{sub 4} laser

Two-micron lasing is obtained on the {sup 5}I{sub 7} → {sup 5}I{sub 8} transition of Ho{sup 3+} ions in ZrO{sub 2} − Y{sub 2}O{sub 3} −Ho{sub 2}O{sub 3} crystals upon resonance pumping into the {sup 5}I{sub 7} level of these ions by a pulsed laser based on a Tm : LiYF{sub 4} crystal. The efficiency of conversion of pump radiation incident on the crystal to laser radiation and the slope lasing efficiency at a pulse duration of 8 ms and a pulse repetition rate of 10 Hz were 25% and 28%, respectively. (paper)

36 MATERIALS SCIENCE↗

Virtual refrigerant charge sensor for variable-speed heat pumps based on feature selection

The refrigerant charge level in heat pump systems significantly impacts their energy efficiency. Virtual refrigerant charge (VRC) sensing technology has been comprehensively investigated and well-established due to its lower cost compared to physical sensors. However, the previous VRC research often relied on expert judgment and physical reasoning for their variable selection, which can potentially select redundant (or highly correlated) or insignificant features, and it is also primarily focused on single-speed systems. To address these challenges, this study proposes a VRC algorithm for variable-speed heat pumps that selects features through a rigorous feature selection method in combination with physical insights. We also propose a piecewise linear model structure segmented by subcooling temperature to accurately predict charge levels, particularly when subcooling temperatures are substantially low. The proposed algorithm was evaluated using experimental data of a residential R410A heat pump, and the performance was compared with two baseline VRC algorithms. The results are: (1) The proposed algorithm outperforms for the case with subcooling temperature less than 1 °C. (2) The proposed algorithm achieves a tested mean absolute percentage error (MAPE) of 4.23%, and improves the overall accuracy for cooling conditions by approximately 60%, compared with the two baseline algorithms. (3) The proposed algorithm uses two fewer features and improves the accuracy for undercharge cooling conditions by 68.0%, compared with baseline algorithm 2. These improvements enhance prediction accuracy and prevent overfitting, providing a more reliable refrigerant charge level prediction and helping improve the heat pump energy efficiency.

Liang, Chenjiyu↗

Consumer Guide to Geothermal Heat Pumps

Learn how geothermal heat pumps can provide energy efficient heating and cooling using the earth's natural heat. This fact sheet from Energy Saver includes information on how geothermal heat pumps work, how they are different from air-source heat pumps, the types of geothermal heat pumps, and how they can help you save energy and money.

geothermal heat pump, heating, cooling, Energy Sav↗

Coherent Doppler lidar for automated space vehicle, rendezvous, station-keeping and capture

Recent advances in eye-safe, short wavelength solid-state lasers offer real potential for the development of compact, reliable, light-weight, efficient coherent lidar. Laser diode pumping of these devices has been demonstrated, thereby eliminating the need for flash lamp pumping, which has been a major drawback to the use of these lasers in space based applications. Also these lasers now have the frequency stability required to make them useful in coherent lidar, which offers all of the advantages of non-coherent lidar, but with the additional advantage that direct determination of target velocity is possible by measurement of the Doppler shift. By combining the Doppler velocity measurement capability with the inherent high angular resolution and range accuracy of lidar it is possible to construct Doppler images of targets for target motion assessment. A coherent lidar based on a Tm,Ho:YAG 2-micrometer wavelength laser was constructed and successfully field tested on atmospheric targets in 1990. This lidar incorporated an all solid state (laser diode pumped) master oscillator, in conjunction with a flash lamp pumped slave oscillator. Solid-state laser technology is rapidly advancing, and with the advent of high efficiency, high power, semiconductor laser diodes as pump sources, all-solid-state, coherent lidars are a real possibility in the near future. MSFC currently has a feasibility demonstration effort under way which will involve component testing, and preliminary design of an all-solid-state, coherent lidar for automatic rendezvous, and capture. This two year effort, funded by the Director's Discretionary Fund is due for completion in 1992.

Dunkin, James A.↗

A Year-Round Energy-Efficient Fresh Air Handling System with Two-Stage Heat Pumps and Lake Water Pre-Treatment

Supplying fresh air is important for indoor air quality, but the energy consumption to treat fresh air is significant. The main problems in existing fresh air system include: supplying single-temperature water to treat fresh air and not applying natural energy sufficiently restrict the efficiency improvement of cooling and heat sources; unused air handling devices under most operating conditions throughout the year increase the fan energy consumption. Thus, this study proposes an efficient fresh air system that uses lake water to pre-treat fresh air and two-stage heat pumps for further treatment, and the unused air handling devices in the system are bypassed. A fresh air system in northern China is selected as a case to show the annual energy performance of the proposed system, and a comparative analysis is conducted between the proposed system and a traditional system. The results show that the annual energy-savings of the proposed system compared to the traditional system come from fans, and compressors, which are 56.5%, and 31.1%, respectively, with an entire system energy saving of 32.2%. The proposed system can achieve an annual system coefficient of performance (COP) of 5.5. This study provides potential for further improving the energy efficiency in fresh air treatment.

Liang, Chenjiyu↗

Inducer analysis/pump model development

Current design of high performance turbopumps for rocket engines requires effective and robust analytical tools to provide design information in a productive manner. The main goal of this study was to develop a robust and effective computational fluid dynamics (CFD) pump model for general turbopump design and analysis applications. A finite difference Navier-Stokes flow solver, FDNS, which includes an extended k-epsilon turbulence model and appropriate moving zonal interface boundary conditions, was developed to analyze turbulent flows in turbomachinery devices. In the present study, three key components of the turbopump, the inducer, impeller, and diffuser, were investigated by the proposed pump model, and the numerical results were benchmarked by the experimental data provided by Rocketdyne. For the numerical calculation of inducer flows with tip clearance, the turbulence model and grid spacing are very important. Meanwhile, the development of the cross-stream secondary flow, generated by curved blade passage and the flow through tip leakage, has a strong effect on the inducer flow. Hence, the prediction of the inducer performance critically depends on whether the numerical scheme of the pump model can simulate the secondary flow pattern accurately or not. The impeller and diffuser, however, are dominated by pressure-driven flows such that the effects of turbulence model and grid spacing (except near leading and trailing edges of blades) are less sensitive. The present CFD pump model has been proved to be an efficient and robust analytical tool for pump design due to its very compact numerical structure (requiring small memory), fast turnaround computing time, and versatility for different geometries.

Cheng, Gary C.↗

A highly efficient, 10-J output signal amplifier for ultra-intense all-OPCPA systems

Optical parametric chirped-pulse amplification (OPCPA) using high-energy Nd:glass lasers has the potential to produce ultra-intense pulses (>10 23 W/cm 2 ). We report on the performance of the final high-efficiency amplifier in an OPCPA system based on large-aperture (63 x 63-mm 2 ) partially deuterated potassium dihydrogen phosphate (DKDP) crystals. Here, the seed beam (170 nm, 240 mJ) was provided by the preceding OPCPA stages. The maximum pump-to-signal conversion efficiency of 37% was achieved with a 52-mm-long DKDP crystal and 40-J pump energy at 527 nm due to the flattop super-Gaussian pump beam profile and flat-in-time pulse shape. The 11.8-J output signal was compressed to 19 fs.

42 ENGINEERING↗

Liquid rocket engine centrifugal flow turbopumps

Design criteria and recommended practices are discussed for the following configurations selected from the design sequence of a liquid rocket engine centrifugal flow turbopump: (1) pump performance including speed, efficiency, and flow range; (2) impeller; (3) housing; and (4) thrust balance system. Hydrodynamic, structural, and mechanical problems are addressed for the achievement of required pump performance within the constraints imposed by the engine/turbopump system. Materials and fabrication specifications are also discussed.

Source record↗

Performance Results from DOE Cold Climate Heat Pump Challenge Field Validation

Space conditioning and water heating consume over 40% of the nation’s primary energy use and represent a significant component of many homeowners’ monthly energy bill. However, in cold climates, performance of heat pumps has traditionally suffered as the units have been unable to efficiently transfer heat from colder outdoor air temperatures to warm the interior space of homes. Optimizing heat pumps for cold climates (5 °F and below) requires coordinated effort to ensure heat pump technologies can be enjoyed by Americans living in these regions. The DOE Cold Climate Heat Pump (CCHP) Challenge sought to address this challenge by partnering with industry to develop, test, and validate the performance of new, highly efficient heat pumps in real homes. The Challenge, launched in 2021, brought together leading heating, ventilation, and air conditioning (HVAC) manufacturers to develop prototype units optimized for performance at cold climates. This report summarizes results from the field validation that occurred 2022-2024.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Amplified spontaneous emission from europium-based molecular complexes coupled to photonic crystal cavities

Rare-earth ion-based materials bear many remarkable optical properties that render them highly appealing for lighting and quantum-related applications. However, their small oscillator strength and weak emission often pose limitations. Here, in this work, we synthesize and couple Eu(III)-based molecular complexes to nanobeam photonic crystals supporting air modes. A reasonable spatial overlap between the molecular complexes and cavity modes leads to an average spontaneous emission coupling efficiency of 0.19. Our pump power-dependent photoluminescence measurements evidence amplified spontaneous emission from the molecular complexes with an amplification threshold as low as 4.4 W/cm 2 , likely benefiting from the efficient coupling. These findings suggest that integrating rare-earth ion-based molecular complexes with photonic structures could be a viable approach for regulating their emission characteristics for particular applications.

36 MATERIALS SCIENCE↗