Ultrafast Adsorbate Excitation Probed with Subpicosecond-Resolution X-Ray Absorption Spectroscopy

We use a pump-probe scheme to measure the time evolution of the C K-edge x-ray absorption spectrum from CO/Ru(0001) after excitation by an ultrashort high-intensity optical laser pulse. Because of the short duration of the x-ray probe pulse and precise control of the pulse delay, the excitation-induced dynamics during the first picosecond after the pump can be resolved with unprecedented time resolution. By comparing with density functional theory spectrum calculations, we find high excitation of the internal stretch and frustrated rotation modes occurring within 200 fs of laser excitation, as well as thermalization of the system in the picosecond regime. The ~100 fs initial excitation of these CO vibrational modes is not readily rationalized by traditional theories of nonadiabatic coupling of adsorbates to metal surfaces, e.g., electronic frictions based on first order electron-phonon coupling or transient population of adsorbate resonances. Finally, we suggest that coupling of the adsorbate to nonthermalized electron-hole pairs is responsible for the ultrafast initial excitation of the modes.

47 OTHER INSTRUMENTATION↗

Technology Development of a Solid State 266 nm Laser for NASA’s Dragonfly Mission

NASA’s Dragonfly mission is a rotorcraft lander which will explore several geologic locations on Saturn’s moon, Titan and investigate evidence of surface-level prebiotic chemistry as well as search for chemical signatures of water-based and/or hydrocarbon-based life. To perform molecular composition investigations in-situ, the payload includes the Dragonfly Mass Spectrometer (DraMS), being developed at NASA’s Goddard Space Flight Center (GSFC). DraMS will utilize laser desorption mass spectrometry (LDMS) to interrogate surface samples and measure the organic composition. Enabling this science capability is the Throttled Hydrocarbon Analysis by Nanosecond Optical Source (THANOS) laser being developed at NASA-GSFC. The THANOS laser is comprised of a solid state, passively Q-Switched Nd:YAG oscillator which is frequency converted to 266 nm and utilizes a RTP high voltage electro-optic for pulse energy control. The laser outputs <2.0 ns pulses with a maximum energy of approximately 200 uJ which can be emitted in 1 - 50 shot bursts at 100 Hz while performing LDMS science operations. While operating, the laser has the capability to throttle its UV pulse energy output from full attenuation to maximum energy to provide varying levels of fluence on samples in the DraMS instrument. This paper reports the technology development and space qualification effort of the THANOS laser including vibration, thermal vacuum cycling, radiation as well as Titan atmospheric composition optical damage testing performed at NASA-GSFC from 2019 through 2022.

Matthew W Mullin↗

Fabrication of carbon nanoribbons from carbon nanotube arrays

Inter-allotropic transformations of carbon are provided using moderate conditions including alternating voltage pulses and modest temperature elevation. By controlling the pulse magnitude, small-diameter single-walled carbon nanotubes are transformed into larger-diameter single-walled carbon nanotubes, multi-walled carbon nanotubes of different morphologies, and multi-layered graphene nanoribbons.

36 MATERIALS SCIENCE↗

Power supply circuit with multiple stages for converting high voltage to low voltage and power train having the same

A power supply circuit for converting a first voltage to a second voltage where the first voltage is greater than the second voltage, and a power train having the same, are provided. The power supply circuit may have multiple stages and each stage of the power supply circuit may include a first circuit block configured to provide a start-up power to a second circuit block; a second circuit block configured to generate a Pulse-Width-Modulation (PWM) signal that controls a pulse duration of a transistor; a third circuit block configured to activate or deactivate the transistor based on the PWM signal; a fourth circuit block configured to reset a magnetic flux in a transformer to a zero state when the transistor is deactivated; and a fifth circuit block configured to maintain an output of a stage below a predetermined value by adjusting a voltage across the transformer.

Singh, Brij N.↗

Integrating solids and gases for attosecond pulse generation

Here, control of the field of few-cycle optical pulses has had an enormous impact on attosecond science. Subcycle pulses open the potential for non-adiabatic phase matching while concentrating the electric field so it can be used most efficiently. However, subcycle field transients have been difficult to generate. We exploit the perturbative response of a sub-100 µm thick monocrystalline quartz plate irradiated by an intense few-cycle 1.8 µm pulse, which creates a phase-controlled supercontinuum spectrum. Within the quartz, the pulse becomes space–time coupled as it generates a parallel second harmonic. Vacuum propagation naturally leads to a subcycle electric-field transient whose envelope is sculpted by the carrier envelope phase of the incident radiation. We show that a second medium (either gas or solid) can generate isolated attosecond pulses in the extreme ultraviolet region. With no optical elements between the components, the process is scalable to very high energy pulses and allows the use of diverse media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and experimental demonstration of feedback adaptive RMP ELM controller toward complete long pulse ELM suppression on KSTAR

Operation of a fusion power plant requires robust edge localized mode (ELM) suppression simultaneously with high plasma performance. In this study, we describe a novel feedback adaptive resonant magnetic perturbation (RMP) ELM controller designed to address this problem by achieving optimized ELM suppression through the advanced application of 3D RMPs. From real-time $D_α$ data, the controller is achievable robust ELM suppression while simultaneously minimizing the applied RMP in order to enhance plasma performance. In real time, the instantaneous ELM-frequency is analyzed with an adaptive feedback algorithm to determine amplitudes and phases of RMP coil currents that will maximize plasma performance while maintaining ELM suppression. When applied through the KSTAR plasma control system in several experiments using $textiti{n}$ = 1 RMPs, robust ELM suppression is achieved and sustained in feedback while reducing the RMP strength to ~65% of its initial value. Minimization of the RMP strength in this manner not only allows for operation of longer discharges due to a decrease in flux consumption but also allows for a strong recovery of up to ~60% of $β_N$ throughout the ELM-free period.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sub-Femtosecond Stark Control of Molecular Photoexcitation with Near Single-Cycle Pulses

Electric fields can tailor molecular potential energy surfaces by interaction with the electronic state-dependent molecular dipole moment. Recent developments in optics have enabled the creation of ultrashort few-cycle optical pulses with precise control of the carrier envelope phase (CEP) that determines the offset of the maxima in the field and the pulse envelope. This opens news ways of controlling ultrafast molecular dynamics by exploiting the CEP. In this work, we show that the photoabsorption efficiency of oriented H 2 CSO (sulfine) can be controlled by tuning the CEP. As a result, we further show that this control emanates from a resonance condition related to Stark shifting of the electronic energy levels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-resonant dynamic stark control of vibrational motion with optimized laser pulses

The term dynamic Stark control (DSC) has been used to describe methods of quantum control related to the dynamic Stark effect, i.e., a time-dependent distortion of energy levels. Here, we employ analytical models that present clear and concise interpretations of the principles behind DSC. Within a linearly forced harmonic oscillator model of vibrational excitation, we show how the vibrational amplitude is related to the pulse envelope, and independent of the carrier frequency of the laser pulse, in the DSC regime. Furthermore, we shed light on the DSC regarding the construction of optimal pulse envelopes — from a time-domain as well as a frequency-domain perspective. Finally, in a numerical study beyond the linearly forced harmonic oscillator model, we show that a pulse envelope can be constructed such that a vibrational excitation into a specific excited vibrational eigenstate is accomplished. The pulse envelope is constructed such that high intensities are avoided in order to eliminate the process of ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method for controlling energy density for reliable pulsed laser deposition of thin films

We have established a methodology to stabilize the laser energy density on a target surface in pulsed laser deposition of thin films. To control the focused laser spot on a target, we have imaged a defined aperture in the beamline (so called image-focus) instead of focusing the beam on a target based on a simple “lens-focus.” To control the laser energy density on a target, we have introduced a continuously variable attenuator between the output of the laser and the imaged aperture to manipulate the energy to a desired level by running the laser in a “constant voltage” mode to eliminate changes in the lasers’ beam dimensions. This methodology leads to much better controllability/reproducibility for reliable pulsed laser deposition of high performance electronic thin films.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High power pulse systems for surface processing

A high-power pulsed surface processing system includes insulated-gate bipolar transistors (IGBT) to replicate desirable pulse structures with high precision, at low cost, and with high reliability within a single system. The pulsed surface processing system includes a power supply, an anode and a cathode, a dual gate driver supplying power to one or more IGBT gates, and one or more capacitor banks. Pulse formation software controls the timing and duration of electrical pulses to the electrodes. A freewheeling diode protects the system from an abrupt reduction of current in the circuit. The high-power pulsed surface processing system may be used to control versatile and complex pulse structures while with precise control of instantaneous pulse powers, pulse timing, and process control. The inclusion of dual gate drivers also offers the ability for multiple pulsers to be created and “slaved” together for a wide variety of custom processes.

Tian, Hui↗

Effects of pulse duration on magnetostimulation thresholds

Purpose: Medical imaging techniques such as magnetic resonance imaging and magnetic particle imaging (MPI) utilize time-varying magnetic fields that are subject to magnetostimulation limits, which often limit the speed of the imaging process. Various human-subject experiments have studied the amplitude and frequency dependence of these thresholds for gradient or homogeneous magnetic fields. Another contributing factor was shown to be number of cycles in a magnetic pulse, where the thresholds decreased with longer pulses. The latter result was demonstrated on two subjects only, at a single frequency of 1.27 kHz. Hence, whether the observed effect was due to the number of cycles or due to the pulse duration was not specified. In addition, a gradient-type field was utilized; hence, whether the same phenomenon applies to homogeneous magnetic fields remained unknown. Here, the authors investigate the pulse duration dependence of magnetostimulation limits for a 20-fold range of frequencies using homogeneous magnetic fields, such as the ones used for the drive field in MPI. Methods: Magnetostimulation thresholds were measured in the arms of six healthy subjects (age: 27 ± 5 yr). Each experiment comprised testing the thresholds at eight different pulse durations between 2 and 125 ms at a single frequency, which took approximately 30–40 min/subject. A total of 34 experiments were performed at three different frequencies: 1.2, 5.7, and 25.5 kHz. A solenoid coil providing homogeneous magnetic field was used to induce stimulation, and the field amplitude was measured in real time. A pre-emphasis based pulse shaping method was employed to accurately control the pulse durations. Subjects reported stimulation via a mouse click whenever they felt a twitching/tingling sensation. A sigmoid function was fitted to the subject responses to find the threshold at a specific frequency and duration, and the whole procedure was repeated at all relevant frequencies and pulse durations. Results: The magnetostimulation limits decreased with increasing pulse duration (T{sub pulse}). For T{sub pulse} < 18 ms, the thresholds were significantly higher than at the longest pulse durations (p < 0.01, paired Wilcoxon signed-rank test). The normalized magnetostimulation threshold (B{sub Norm}) vs duration curve at all three frequencies agreed almost identically, indicating that the observed effect is independent of the operating frequency. At the shortest pulse duration (T{sub pulse} ≈ 2 ms), the thresholds were approximately 24% higher than at the asymptotes. The thresholds decreased to within 4% of their asymptotic values for T{sub pulse} > 20 ms. These trends were well characterized (R{sup 2} = 0.78) by a stretched exponential function given by B{sub Norm}=1+αe{sup −(T{sub p}{sub u}{sub l}{sub s}{sub e}/β){sup γ}}, where the fitted parameters were α = 0.44, β = 4.32, and γ = 0.60. Conclusions: This work shows for the first time that the magnetostimulation thresholds decrease with increasing pulse duration, and that this effect is independent of the operating frequency. Normalized threshold vs duration trends are almost identical for a 20-fold range of frequencies: the thresholds are significantly higher at short pulse durations and settle to within 4% of their asymptotic values for durations longer than 20 ms. These results emphasize the importance of matching the human-subject experiments to the imaging conditions of a particular setup. Knowing the dependence of the safety limits to all contributing factors is critical for increasing the time-efficiency of imaging systems that utilize time-varying magnetic fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Binary Optimal Control of Single-Flux-Quantum Pulse Sequences

We introduce a binary, relaxed gradient, trust-region method for optimizing pulse sequences for single flux quanta (SFQ) control of a quantum computer. The pulse sequences are optimized with the goal of realizing unitary gate transformations. Each pulse has a fixed amplitude and duration. Here we model this process as an binary optimal control problem, constrained by Schrödinger’s equation, where the binary variables indicate whether each pulse is on or off. We introduce a first-order trust-region method, which takes advantage of a relaxed gradient to determine an optimal pulse sequence that minimizes the gate infidelity, while also suppressing leakage to higher energy levels. The proposed algorithm has a computational complexity of O(p log(p)), where p is the number of pulses in the sequence. We present numerical results for the H and X gates, where the optimized pulse sequences give gate fidelity’s better than 99.9%, in ≈ 25 trust-region iterations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionization-Based Optical Structures for the Control of Short-Pulse Lasers (Abbreviated LDRD Report)

The intensity of light from the highest-power lasers is limited by the size of the optics required to amplify, compress, transport, and focus a laser beam. Indeed, optics damage puts strict constraints on the laser energy density that solid optics can sustain; this leads to enormous optics sizes and limits the maximum intensity that these lasers can achieve. In this project we investigated new types of diffractive optics based on mixtures of neutral gas and plasmas. The basic idea is to interfere laser beams in a gas near the ionization threshold, so that plasma is created in the constructive interference regions (i.e., the “bright” fringes of the interference pattern) while the destructive interference regions remain a neutral gas. The resulting refractive index modulation, due to the different indices in gas vs. plasma, effectively turns such structures into diffractive optics elements. We proposed several new types of optics based on this general concept: i) reflection gratings, which can act as mirrors of “pulse cleaners” to eliminate laser pre-pulse; ii) transmission gratings, as part of a new type of pulse compression scheme with the potential to achieve laser intensities orders of magnitude above what is currently feasible using solid-state optics; and iii) holographic lenses, to focus high-power lasers. We conducted laboratory experiments which demonstrated high efficiency reflection gratings, paving the way for practical applications of our new concepts.