Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “prototype energy model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Numerical wave modeling for operational and survival analyses of wave energy converters at the US Navy Wave Energy Test Site in Hawaii

The US Navy Wave Energy Test Site (WETS) is currently operating three grid-connected berths off Marine Corps Base Hawaii in support of technological development through scaled-model testing and pre-commercial prototyping. The location on the east shore of Oahu is open to year-round wind waves and seasonal north swells as well as severe seas from subtropical systems and hurricanes. We have assembled a spectral wave model system comprising WAVEWATCH III and SWAN on a hierarchy of global, regional, and nearshore computational grids. With wind forcing from global forecast and rean-alysis datasets as well as their regional downscaling, the system produces operational 7-day wave forecasts and a long-term hindcast. The daily forecasts, validated with real-time buoy measurements, facilitate safe deployment, operation, and retrieval of wave energy converters (WECs). The wave hindcast from 1979 to 2017 defines the intra- and inter-annual variations for statistical analysis of sea states and energy resources. Due to limited occurrences of hurricanes in Hawaii waters, their wind forcing is determined parametrically with simulated tracks from climate model downscaling. Finally, systematic analysis of the hindcast and simulation datasets provides significant wave heights from trade winds, swells, subtropical systems, and hurricanes with return periods up to 100 years for WECs survival analysis.

16 TIDAL AND WAVE POWER↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

Route Energy Prediction (RouteE) Powertrain Validation Report

The National Renewable Energy Laboratory's flagship package in the RouteE suite, RouteE-Powertrain, is a mesoscopic energy model that predicts vehicle energy consumption given discrete attributes that describe each segment or link in a vehicle's path on a road network. High-frequency, physics-based, powertrain simulators, such as NREL's FASTSim, are well-suited to model vehicle energy consumption when real driving data and a detailed understanding of the vehicle powertrain specifications are available. However, there are a variety of situations in the past, present (real-time), and future where high-frequency driving data and/or vehicle information may not be available, but reliable energy consumption is still desired, such as energy-aware vehicle routing. These are the ideal applications for RouteE-Powertrain. The suite of RouteE tools also includes RouteE-Compass, which is an eco-routing software that incorporates energy consumption into network routing algorithms, and RouteE-Mobile, which is a prototype smartphone navigation app to demonstrate the integrated capabilities of the RouteE suite for real-world eco-routing. The focus of this validation report is to share key metrics about the data sets and models behind RouteE-Powertrain. The set of RouteE-Powertrain models discussed in this report are made available through the RouteE web API through the NREL Developer Network.

33 ADVANCED PROPULSION SYSTEMS↗

Band Energy Dependence of Defect Formation in the Topological Semimetal Cd3As2

Cadmium Arsenide (Cd3As2) is a prototypical Dirac semimetal that manifests topological properties in a 3D bulk material. In defect-free Cd3As2, the Fermi level lies at a minimum in the density of states at the Dirac point, but experimentally it forms with excess electron carriers and an elevated EF, thereby masking the topological features. To computationally study the self-doping of Cd3As2, we combine density functional theory (DFT) calculations for defect formation energies with quasi-particle self-consistent GW (QSGW) electronic structure calculations. We demonstrate an innate dependence of the point defect formation energies on carrier concentrations and use the QSGW calculated density of states to extrapolate formation energies to arbitrary electron concentrations. This approach allows the quantitative modeling of thermodynamic defect equilibria in topological semimetals and is used to predict how Cd3As2 growth conditions affect the position of EF relative to the Dirac point.

CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS↗

Data-Enabled Predictive Control for Building HVAC Systems

Model predictive control is widely used as a control technology for the computation of optimal control inputs of building heating, ventilating, and air conditioning (HVAC) systems. However, both the benefits and widespread adoption of model predictive control (MPC) are hindered by the effort of model creation, calibration, and accuracy of the predictions. In this paper, we apply the data-enabled predictive control (DeePC) algorithm for designing controls for building HVAC systems. The algorithm solely depends on input/output data from the system to predict future state trajectories without the need for system identification. The algorithm relies on the idea that a vector space of all input–output trajectories of a discrete-time linear time-invariant (LTI) system is spanned by time-shifts of a single measured trajectory, given the input signal is persistently exciting. Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated building modeled in EnergyPlus is a modified commercial large office prototype building served by an air handling unit-variable air volume HVAC system. Temperature setpoints of zones are used as control variables to minimize the HVAC energy cost of the building considering a time-of-use electricity rate structure. Furthermore, sensitivity analysis is conducted to gain insights into the effect of parameter tuning on DeePC performance. Simulation results are used to illustrate the performance of the algorithm and compare the algorithm with model-based MPC and occupancy-based setpoint controller. Overall, DeePC achieves similar performance compared to MPC for lower engineering effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A high efficiency rooftop air conditioning system using multi-speed compressors

This study delineates a meticulous exploration of technologies to enhance the energy efficiency of rooftop air conditioning units, employing the DOE/ORNL heat pump design model for comprehensive engineering design and optimization. A baseline rooftop air conditioning unit, featuring a 13 ton (45.7 kW) cooling capacity and a 17.9 integrated energy efficiency ratio, served as the point of departure for substantive efficiency enhancements. Key modifications included the consolidation of two refrigerant circuits into one, integrating three parallel 2-stage (dual-speed) compressors, fan replacements with high-efficiency substitutes. Notably, a lower global warming potential refrigerant, R452B, was evaluated as a substitute for R-410A, demonstrating better performance in the lab prototype. Further, the achieved measured integrated energy efficiency ratio of 21.4 in the lab prototype surpassed the baseline integrated energy efficiency ratio. Comparative evaluations between R410A and R452B indicated heightened efficiency with the latter, showcasing a lab-demonstrated integrated energy efficiency ratio of 22.4 at the rated capacity of 13.8 ton (48.5 kW) and 23.9 integrated energy efficiency ratio at the rated capacity of 10 ton (35.2 kW). This research underscores the successful development of a rigorous, energy efficient rooftop air conditioning unit prototype with noteworthy environmental and economic implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ISRU System Model Tool: From Excavation to Oxygen Production

In the late 80's, conceptual designs for an in situ oxygen production plant were documented in a study by Eagle Engineering [1]. In the "Summary of Findings" of this study, it is clearly pointed out that: "reported process mass and power estimates lack a consistent basis to allow comparison." The study goes on to say: "A study to produce a set of process mass, power, and volume requirements on a consistent basis is recommended." Today, approximately twenty years later, as humans plan to return to the moon and venture beyond, the need for flexible up-to-date models of the oxygen extraction production process has become even more clear. Multiple processes for the production of oxygen from lunar regolith are being investigated by NASA, academia, and industry. Three processes that have shown technical merit are molten regolith electrolysis, hydrogen reduction, and carbothermal reduction. These processes have been selected by NASA as the basis for the development of the ISRU System Model Tool (ISMT). In working to develop up-to-date system models for these processes NASA hopes to accomplish the following: (1) help in the evaluation process to select the most cost-effective and efficient process for further prototype development, (2) identify key parameters, (3) optimize the excavation and oxygen production processes, and (4) provide estimates on energy and power requirements, mass and volume of the system, oxygen production rate, mass of regolith required, mass of consumables, and other important parameters. Also, as confidence and high fidelity is achieved with each component's model, new techniques and processes can be introduced and analyzed at a fraction of the cost of traditional hardware development and test approaches. A first generation ISRU System Model Tool has been used to provide inputs to the Lunar Architecture Team studies.

Santiago-Maldonado, Edgardo↗

Hierarchical Conceptual Model Event and Activity Domains for Forecasting State-Sponsored Civil Nuclear Power Activities

In FY20, the Savannah River National Laboratory and the Sanghani Center for Artificial Intelligence and Data Analytics (Virginia Tech) entered a collaboration funded by the Department of Energy’s Office of Defense Nuclear Nonproliferation Research and Development to develop a machine learning based modeling pipeline to extract proliferation events of interest from open data sources. The prototype modeling pipeline that was developed relies on the use of time dependent word embedding models to identify contextual shifts in key words and phrases that act as indicators of events of interest. The FY20- 21 efforts were focused on a narrow topical domain of forecasting “fissile core fabrication” at the Savannah River Site prior to its official announcement in 2018. In FY22, the research team was funded to continue development of the modeling pipeline by applying it to the problem of forecasting new, and/or significant changes to existing, civil nuclear power reactors around the world. In this effort, the development will focus on proving applicability to a broader topical domain and in data environments that may contain more sparse information, relative to the United States. In this report, the worldwide landscape of civil nuclear reactors is outlined, the timeline of interest is defined, and a hierarchical conceptual model is established to identify the activity domains of interest and the event domains of interest. This preliminary effort will guide the curation of a glossary of key terms for data acquisition, as well as the downstream modeling efforts.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Zigzag flow reactor for weekly thermochemical energy storage

This paper describes theoretical models and experimental performance of a novel Zigzag Flow Reactor (ZFR) for weekly thermochemical energy storage. The ZFR reduces redox-active metal oxide (MO x ) particles at high temperature (up to ~1100 °C) under inert gas sweep. A physical model demonstrates the approach to process equilibrium by minimizing the associated exergy destruction in a finite number of reaction steps, establishing the thermodynamic requirements for a practical reactor. The model results show several cost-relevant parameter tradeoffs, and the tradeoff analysis implies a cost-optimized set of boundary conditions. Numerical models and prototypes show that the ZFR enables significant gas phase homogenization while simultaneously enabling a customizable MO x residence time in the reactor, both key requirements for approaching an equilibrium process. A scaling model demonstrates the simplicity and affordability of sizing the ZFR to grid-scale levels, with fabrication costs at least five times lower than previously proposed scalable reactor concepts. As a result, a laboratory ZFR prototype achieved an energy storage density of ~90 Wh/kg with CaAl 0.2 Mn 0.8 O 3-δ as the MO x , at temperatures of ~850 °C in >10 h of total runtime.

Thermochemical energy storage↗

Quality Control Methods for Advanced Metering Infrastructure Data

While urban-scale building energy modeling is becoming increasingly common, it currently lacks standards, guidelines, or empirical validation against measured data. Empirical validation necessary to enable best practices is becoming increasingly tractable. The growing prevalence of advanced metering infrastructure has led to significant data regarding the energy consumption within individual buildings, but is something utilities and countries are still struggling to analyze and use wisely. In partnership with the Electric Power Board of Chattanooga, Tennessee, a crude OpenStudio/EnergyPlus model of over 178,000 buildings has been created and used to compare simulated energy against actual, 15-min, whole-building electrical consumption of each building. In this study, classifying building type is treated as a use case for quantifying performance associated with smart meter data. This article attempts to provide guidance for working with advanced metering infrastructure for buildings related to: quality control, pathological data classifications, statistical metrics on performance, a methodology for classifying building types, and assess accuracy. Advanced metering infrastructure was used to collect whole-building electricity consumption for 178,333 buildings, define equations for common data issues (missing values, zeros, and spiking), propose a new method for assigning building type, and empirically validate gaps between real buildings and existing prototypes using industry-standard accuracy metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and evaluation of a dilute flow particle-to-air heat exchanger for energy storage applications

The use of inert and redox-active particles for high-temperature energy storage requires the development of components that can efficiently transfer energy to high-pressure working fluids like supercritical carbon dioxide (sCO 2 ). Dilute flow reactors can enable high working fluid outlet temperatures and minimal parasitic losses compared to moving packed bed and fluidized bed reactors. This research uses both computational and experimental methods to explore the design trade-offs and practical challenges of a novel component for transferring energy from dilute flows of hot, reduced metal oxide (MO x ) particles to sCO 2 in tubes. A discretized thermal resistance network model, which accounts for particle hydrodynamics, multi-mode heat transfer, and reaction equilibrium, guides the design of a prototype device. This device is experimentally tested with a surrogate heat transfer fluids and inert particle temperatures up to 400°C and a heat duty exceeding 1 kW. The data are used to validate the thermal hydraulic sub-models, allowing for the simulation of reacting particle scenarios. Under nominal design conditions, the flow rate of reactive particles is predicted to be 30% lower than that of inert particles for the same energy recovered, with over 70% of the stored particle energy transferred to the sCO 2 . Furthermore, these findings can inform the design of more efficient energy recovery reactors for particle-based systems and can be integrated into system-level concentrated solar power models with thermal storage to optimize operating conditions.

14 SOLAR ENERGY↗

RF sheath induced sputtering on Proto-MPEX. I. Sheath equivalent dielectric layer for modeling the RF sheath

The pulsed linear plasma device Prototype Material Plasma Exposure eXperiment (Proto-MPEX) uses a radio frequency (RF) helicon antenna with an aluminum nitride ceramic window for plasma production. The RF sheath created under the helicon antenna is sufficient to cause ion impact energies to be greater than the sputtering threshold of the AlN helicon window material and for impurities to be created. In this study, we investigate the RF sheath on the inner diameter of the helicon window and its impact on the impurity production rates in Proto-MPEX. Three models—a 3D COMSOL finite element RF model of the Proto-MPEX helicon region, a rectified DC sheath potential model, and the 3D Global Impurity TRansport code—are coupled together to study impurity production and transportation. This novel method of impurity generation and transport modeling spans length scales ranging from the sheath (millimeters or less) up to the full device (meters) and can be applied to other radio frequency sources and antennas in a wide range of plasma physics studies, including basic plasmas, low-temperature processing plasmas, plasma thrusters, and fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sub-Scale Stage 1 Magnetic Gear for a Marine Hydrokinetic Generator

The goal of this project is to design, fabricate, and test a hermetically sealed 50 kilowatt (kW) multistage magnetically geared generator (MGG). In order to reduce risk, a sub-scale 5kW multistage MGG was first built. This project will benefit MHK device developers by providing an MHK PTO that overcomes the reliability concerns of the mechanical gears and the sizing constraints of the direct-drive generators. Measurement data for a 9.5:1 gear ratio magnetic gear with a measured peak torque of 227 N-m as well as the dual stage magnetic gear with a 63:1 gear ratio.

16 TIDAL AND WAVE POWER↗

Gas-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model

This report details a fully coupled neutronics thermal hydraulics reference plant model for a gas-cooled high-temperature pebble-bed reactor. The multiphysics model is developed on the Nuclear Regulatory Commission's Comprehensive Reactor Analysis Bundle (BlueCRAB) available on the Idaho National Laboratory high performance computer, which natively and seamlessly couples Griffin, Pronghorn, and the BISON MOOSE-based applications. Griffin provides the reactor physics capabilities including depletion to the equilibrium core, k-eigenvalue, adjoint, and transient solutions. Pronghorn solves the porous medium equations for the fluid regions and conduction in the solid regions. BISON solves thermal conduction problems for the average pebble and TRISO in the pebble-bed core thus providing the fuel and moderator spatial fields for each pebble burnup group. The neutronics feedback relies primarily on fuel and moderator temperatures. We present results for the coupled steady state equilibrium core and a protected loss of flow event. Although this model is to be considered prototypical with regard to the capabilities in BlueCRAB, its results are consistent with published work by the Institute of Nuclear and New Energy Technology (INET) in China and other research entities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

End-Use Analysis of ASHRAE Standard 90.1-2019

This article summarizes the analysis conducted by Pacific Northwest National Laboratory (PNNL), assessing expected end-use energy consumption in commercial buildings, based on recent editions of the model energy code for the commercial sector, ANSI/ASHRAE/IES Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. The results represent simulated energy use based on) Commercial Prototype Building Models1 across representative climate zones in the United States, as defined by Standard 90.1. PNNL examined the resulting simulation outputs to assess how energy is used across primary systems within prominent U.S. commercial building types to understand how energy is used in each building type at the end-use level and to identify areas for improvements in future code cycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combined TREAT-LOC and SATS LOCA Experiment Plan: Integral LOCA Experiments on High-Burnup Fuels

The Transient Reactor Test Facility (TREAT) loss-of-coolant (LOC) and high-burnup (HBu) experiment series, along with the Severe Accident Test Station (SATS) HBu experiment series, are integral LOC accident (LOCA) experiments planned under the DOE AFC program, which aim to support burnup extension needs by addressing identified R&D priorities in order to achieve an improved understanding of fuel fragmentation, relocation, and dispersal (FFRD) of HBu fuel during LOCA events. The data produced under this plan will be used to further validate and confirm existing models and inform future R&D and model development. The experimental program has been specifically designed to address knowledge gaps and opportunities identified through a detailed review of existing public knowledge on LOCA FFRD. The test program employs a unique combination of in- and out-of-pile experimental approaches and state-of-the-art facilities to provide a clear connection to the existing integral and semi-integral LOCA experiment database. The primary goal of the program is to investigate the impact of prototypic HBu fuel/cladding thermomechanical behaviors under postulated LWR LOCA conditions that have not yet been fully studied. These conditions correspond with prototypic decay-energy heatup (DEH) and stored-energy heatup (SEH) conditions. Importantly, TREAT’s unique capability will enable the first evaluation of the impact of SEH conditions on HBu fuels. The test program will emphasize the development of an improved mechanistic understanding of key experimental phenomena through independent experimental systems, development of a database to support fuel performance modeling tools and employing world-leading advanced materials characterization and in-situ diagnostics to evaluate FFRD. The results of the program will provide novel data to support modeling development and validation and will represent a significant advancement in evaluating prototypic conditions, as well as to inform the technical basis for LOCA-induced FFRD.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of low-exergy heating and cooling systems and topology optimization for deep energy savings at the urban district level

District energy systems have the potential to achieve deep energy savings by leveraging the density and diversity of loads in urban districts. However, planning and adoption of district thermal energy systems is hindered by the analytical burden and high infrastructure costs. It is hypothesized that network topology optimization would enable wider adoption of advanced (ambient temperature) district thermal energy systems, resulting in energy savings. In this study, energy modeling is used to compare the energy performance of “conventional” and “advanced” district thermal energy systems at the urban district level, and a partial exhaustive search is used to evaluate a heuristic for the topology optimization problem. For the prototypical district considered, advanced district thermal energy systems mated with low-exergy building heating and cooling systems achieved a source energy use intensity that was 49% lower than that of conventional systems. The minimal spanning tree heuristic was demonstrated to be effective for the network topology optimization problem in the context of a prototypical district, and contributes to mitigating the problem’s computational complexity. The work presented in this paper demonstrates the potential of advanced district thermal energy systems to achieve deep energy savings, and advances to addressing barriers to their adoption through topology optimization.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗