Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power electronics cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

First conduction cooled photoinjector status

SRF photoguns become a promising candidate to produce highly stable electrons for UEM/UED applications because of the ultrahigh shot-to-shot stability compared to room temperature RF photoguns. SRF technology was prohibitively expensive for industrial use until two recent advancements: Nb3Sn and conduction cooling. SRF gun can provide a CW operation capability while consuming only 2W of RF power which eliminates the need of an expensive high power RF system and saves a facility footprint. Euclid is developing a continuous wave (CW), 1.5-cell, MeV-scale SRF conduction cooled photogun operating at 1.3 GHz. We aim for generation of the first beam in 2024. In this paper, we present the most up-to-date progress including results of the first cool down of the gun-cavity in the newly developed conduction cooled cryomodule and LLRF system development.

43 PARTICLE ACCELERATORS↗

Pulse-by-pulse transient thermal deformation in crystal optics under high-repetition-rate FEL

Time-domain modeling of the thermal deformation of crystal optics can help define acceptable operational ranges across the pulse-energy repetition-rate phase space. In this paper, we have studied the transient thermal deformation of a water-cooled diamond crystal for a cavity-based X-ray free-electron laser (CBXFEL), either an X-ray free-electron laser oscillator (XFELO) or a regenerative amplifier X-ray free-electron laser (RAFEL), by numerical simulations including finite-element analysis and advanced data processing. Pulse-by-pulse transient thermal deformation of a 50 µm-thick diamond crystal has been performed with X-ray pulse repetition rates between 50 kHz and 1 MHz. Results for temperature and thermal deformation have been compared with the results of transient analysis using a continuous wave (CW) power loading. Temperature and thermal deformation results from pulse-by-pulse transient analysis vary with time about the results for the CW case for the same average power. The variation amplitude increases with pulse energy and decreases with repetition rate. When the repetition rate increases to infinity, both temperature and thermal deformation converge to the results for the CW case. Two critical time scales for the operation of crystal optics in a CBXFEL are (1) first-turn time, i.e. the time for the XFEL pulse to complete the first turn around the cavity so that the crystal sees the recirculated XFEL pulse, and (2) period-end time, i.e. the time that the next electron bunch arrives for the amplification, so that the crystal outcouples the amplified FEL power. For the same average power, simulation results show that the crystal thermal deformation seen by the XFEL beam decreases with repetition rate at the first-turn time of a 300 m-long cavity and increases with repetition rate at the period-end time. For the wavefront preservation requirement of the crystal optics, a pulse-energy versus repetition-rate phase space has been established. The upper bounds of the pulse energy at both first-turn and period-end times decreases with repetition rate, especially at the period-end time. The upper bound of the thermal deformation of the crystal at the period-end time for any repetition frequency can be estimated from the CW case. For a water-cooled diamond crystal of dimension 5 mm × 5 mm × 0.05 mm, the time to reach a quasi steady-state is about 50 ms for temperature and 50 µs for thermal deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Studies of CMS High-Granularity Calorimeter (HGCAL) Cassettes for the HL-LHC Upgrade

The CMS High Granularity Calorimeter (HGCAL) is a key endcap upgrade for the High-Luminosity LHC, designed to operate in an environment of extreme radiation and high particle rates. Each HGCAL cassette integrates silicon and scintillator modules, front-end ASICs, and a copper cooling plate that provides both mechanical integrity and thermal coupling using two-phase CO₂ cooling. Stable and uniform temperature control is essential to ensure reliable performance of the front-end electronics and to limit radiation-induced leakage currents in the silicon sensors. We present results from thermal characterization studies of pre-series HGCAL cassettes assembled and tested at Fermilab. Embedded RTD/PT1000 temperature sensors were used to measure gradients across copper cooling plates, module layers, and cassette edges under powering conditions representative of operation. The measured thermal behavior demonstrates effective heat transport through the cassette stack and highlights small but systematic variations correlated with geometry and assembly tolerances. These results validate the cooling performance of HGCAL cassettes.

Wang, Jinglu [Northwestern U.]↗

James Webb Space Telescope Mid Infra-Red Instrument Pulse-Tube Cryocooler Electronics

The latest generation of long life, space pulse-tube cryocoolers require electronics capable of controlling self-induced vibration down to a fraction of a newton and coldhead temperature with high accuracy down to a few kelvin. Other functions include engineering diagnostics, heater and valve control, telemetry and safety protection of the cryocooler subsystem against extreme environments and operational anomalies. The electronics are designed to survive the thermal, vibration, shock and radiation environment of launch and orbit, while providing a design life in excess of 10 years on-orbit. A number of our current generation high reliability radiation-hardened electronics units are in various stages of integration on several space flight payloads. This paper describes the features and performance of our latest flight electronics designed for the pulse-tube cryocooler that is the pre-cooler for a closed cycle Joule-Thomson cooler providing 6K cooling for the James Webb Space Telescope (JWST) Mid Infra-Red Instrument (MIRI). The electronics is capable of highly accurate temperature control over the temperature range from 4K to 15K. Self-induced vibration is controlled to low levels on all harmonics up to the 16th. A unique active power filter controls peak-to-peak reflected ripple current on the primary power bus to a very low level. The 9 kg unit is capable of delivering 360W continuous power to NGAS's 3-stage pulse-tube High-Capacity Cryocooler (HCC).

thermometry↗

A Multiwavelength Study of the Extreme AGN J2310-437

We present new X-ray, radio, and optical data for the unusual galaxy/cluster system J2310-437. Our results confirm the presence of an active nucleus and suggest an interpretation as an anomalous BL Lac object of bulk relativistic Doppler factor <2, with an optically deficient radio to X-ray spectrum. The radio, optical, and soft X-ray flux densities could lie along a single power-law function, lacking the curvature typical of BL Lac objects. Compared with other known sources that may have comparable multi-frequency spectra, J2310-437 is the most extreme. Its low isotropic optical/Ultraviolet (UV) radiation is consistent with the intensity of external photons governing the electron spectral break through Compton cooling; in this source the external photon density would be too low to produce a spectral break below the X-ray.

Worrall, D. M.↗

X-57 Electromagnetic Interference Design, Integration, and Test Consideration

X-57 is NASA’s first all electric aircraft that utilizes existing airframe of Tecnam 2006P GA aircraft integrated with new all electric power train. The objective of the project was to deliver high performing distributed electric propulsion system while developing US industry in the area of EAP. The project was divided into three distinct flight mods, each serving as a risk reduction efforts to final mod where full distributed power train with highly modified wing structure would be tested in flight. Flight weight, efficient power electronics are enablers for distributed, electric aircraft propulsion systems, and GRC team has developed high power and highly efficient SiC based converters for both cruise and high lift systems on the aircraft. Both controller’s development efforts demonstrate a means to achieve an in-the-nacelle controller with purely passive cooling while maintaining high efficiency. This paper describes the lessons learned on design, integration, and testing challenges that X-57 faced while developing these novel technologies.

Power Train↗

Autonomous quantum absorption refrigerators

Here, we propose a quantum absorption refrigerator using the quantum physics of resonant tunneling through quantum dots. The cold and hot reservoirs are fermionic leads, tunnel coupled via quantum dots to a central fermionic cavity, and we propose configurations in which the heat absorbed from the (very hot) central cavity is used as a resource to selectively transfer heat from the cold reservoir on the left to the hot reservoir on the right. Heat transport in the device is particle-hole symmetric; we find two regimes of cooling as a function of the dot energies—symmetric with respect to the Fermi energy of the reservoirs—and we associate them with heat transfer by electrons above the Fermi level and holes below the Fermi level. We also discuss optimizing the cooling effect by fine-tuning the energy of the dots as well as their linewidth and characterize regimes where the transport is thermodynamically reversible such that the Carnot coefficient of performance is achieved with zero cooling power delivered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Temperature Regenerators for Zero Boil-Off Liquid Hydrogen Pulse Tube Cryocoolers

Recently, a great deal of attention has been focused on zero boil-off (ZBO) propellant storage as a means of minimizing the launch mass required for long-term exploration missions. A key component of ZBO systems is the cooler. Pulse tube coolers offer the advantage of zero moving mass at the cold head, and recent advances in lightweight, high efficiency cooler technology have paved the way for reliable liquid oxygen (LOx) temperature coolers to be developed which are suitable for flight ZBO systems. Liquid hydrogen (LH2) systems, however, are another matter. For ZBO liquid hydrogen systems, cooling powers of 1-5 watts are required at 20 K. The final development from tier for these coolers is to achieve high efficiency and reliability at lower operating temperatures. Most of the life-limiting issues of flight Stirling and pulse tube coolers are associated with contamination, drive mechanisms, and drive electronics. These problems are well in hand in the present generation coolers. The remaining efficiency and reliability issues reside with the low temperature regenerators. This paper will discuss advances to be made in regenerators for pulse tube LH2 ZBO coolers, present some historical background, and discuss recent progress in regenerator technology development using alloys of erbium.

Salerno, Louis J.↗

Electrospun Silica Nanofibers as Passive Thermal Control Materials for the Extreme Environment of Low Earth Orbit

Effective thermal management is crucial for maintaining spacecraft and onboard systems at optimal temperatures, ensuring their longevity in space missions. Passive thermal management is particularly promising due to its lower power consumption compared to active systems. This study focuses on developing materials with low solar absorptance and large thermal emittance to facilitate self-cooling under the harsh thermal conditions of space. We employ electrospinning, a nano/micro-manufacturing technique, to create a lightweight, fibrous thermal control material from silica (SiO 2 ). Using scanning electron microscopy (SEM), we examine the nanoporous structure of the electrospun material. Its optical properties, including reflectance, transmittance, and absorptance across ultraviolet, visible, and infrared wavelengths, are assessed using spectrometers interfaced with integrating spheres. To test durability in space, we conduct high temperature endurance and ultraviolet resistance tests to observe changes in optical properties of the materials and evaluate their performance in low Earth orbit (LEO). We also compare the material's solar reflectance and thermal emittance to existing spacecraft materials. The findings suggest that electrospun silica nanofibers presents a new paradigm for passive thermal control in space applications.

thermal emittance↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

A high efficiency and low vibration liquid nitrogen cooling system for silicon crystal based x-ray optics

A compact low-cost cryocooling system has been designed, constructed, and tested at SLAC National Accelerator Laboratory. The cooling power is provided by natural convection and phase change of the liquid nitrogen. The initial application was to cool silicon crystal optics to the sub-100 K range. A silicon crystal of dimension (width × depth × height) 50 × 50 × 30 mm3 has been used with an electric heater on the top surface in this prototyping test. This system can effectively provide more than 80 W of cooling power to the optics with a consumption of liquid nitrogen less than 2.1 l/h. The vibration of the silicon crystal was monitored during the tests with added electric heater power on the crystal. We note the vibration of the silicon crystal due to liquid nitrogen boiling is negligible.

47 OTHER INSTRUMENTATION↗

Final Design and Analysis of the Superconducting Magnets for the Material Plasma Exposure Experiment

The Material Plasma Exposure eXperiment (MPEX), which has completed its final design, is a new linear plasma device to advance the understanding of plasma-material interactions through the generation and delivery of plasmas as they are expected in future fusion reactor divertors. MPEX will be a steady-state device to study high-fluence exposures of plasma-facing materials and components. The requirements for the magnetic field at the heating stages and the target make the application of superconducting coils necessary. The final designs for the superconducting magnets have been developed using three cryostat designs with warm bore diameters of 65 cm and 156 cm. The large bores are required to for other systems such as vacuum, water cooling, and RF power. There are 19 superconducting coils in MPEX that are contained in six cryostats. Although design, fabrication, and testing for the magnets as stand-alone units are straightforward, challenges will arise during the integration of the system. Various field profiles will be used during operation. The magnetic field where the electron cyclotron heating occurs needs to operate at both 1.25 and 2.50 T. Analyses that have been performed on the final design include designing the coils and determining operating currents to meet field requirements, forces between cryostats, the effects of coil and/or cryostat movement, and quench analysis. To ensure that the magnetic field requirements are met, a plan for monitoring the magnetic field at specified locations has been developed which includes the effect of coil and/or cryostat movement.

Burkhardt, Earle↗

Description of A 2.3 kW power transformer for space applications

The paper describes the principal features and special testing of a high-frequency high-power low-specific-weight (0.57 kg/kW) 2.3-kW electronic power transformer developed for space applications. The transformer is operated in a series resonant inverter supplying beam power to a 30-cm mercury ion thruster. High efficiency (above 98.5%) is obtained through careful detailed design. A number of unique heat removal techniques are discussed which control the winding temperature using only the available conductive cooling.

Hansen, I.↗

Cryogenic Cooling for Myriad Applications-A STAR Is Born

Cryogenics, the science of generating extremely low temperatures, has wide applicability throughout NASA. The Agency employs cryogenics for rocket propulsion, high-pressure gas supply, breathable air in space, life support equipment, electricity, water, food preservation and packaging, medicine, imaging devices, and electronics. Cryogenic liquid oxygen and liquid hydrogen systems are also replacing solid rocket motor propulsion systems in most of the proposed launch systems, a reversion to old-style liquid propellants. In the late 1980s, NASA wanted a compact linear alternator/motor with reduced size and mass, as well as high efficiency, that had unlimited service life for use in a thermally driven power generator for space power applications. Prior development work with free-piston Stirling converters (a Stirling engine integrated with a linear actuator that produces electrical power output) had shown the promise of that technology for high-power space applications. A dual use for terrestrial applications exists for compact Stirling converters for onsite combined heat and power units. The Stirling cycle is also usable in reverse as a refrigeration cycle suitable for cryogenic cooling, so this Stirling converter work promised double benefits as well as dual uses. The uses for cryogenic coolers within NASA abound; commercial applications are similarly wide-ranging, from cooling liquid oxygen and nitrogen, to cryobiology and bio-storage, cryosurgery, instrument and detector cooling, semiconductor manufacturing, and support service for cooled superconducting power systems.

Source record↗

Impulsive H-alpha diagnostics of electron-beam-heated solar flare model chromospheres

Time-dependent H-alpha profiles were computed for the dynamic model atmospheres of Fisher, Canfield, and McClymont (1985) simulating the effects of an intense impulsively initiated power-law beam of electrons incident on the chromosphere. The temporal response of H-alpha arises from three separate physical mechanisms, whose relative importance varies over the line profile. The fastest variations (typically less than 0.1 s for the explosive heating discussed here) arise from energy imbalance; these are apparent on chromospheric heating and cooling time scales and have their greatest amplitude at line center. Slower variations arise from ionization imbalance and are most apparent in the blue wing. The slowest variations arise from hydrodynamic effects and are related to the formation of a chromospheric condensation; these are most apparent in the red wing. These results provide a basis for the design and analysis of observations of H-alpha, in coordination with hard X-rays or microwaves, to test mechanisms of energy transport in solar flares.

Canfield, Richard C.↗

Lynx x-ray microcalorimeter

Lynx is an x-ray telescope, one of four large satellite mission concepts currently being studied by NASA to be a flagship mission. One of Lynx’s three instruments is an imaging spectrometer called the Lynx x-ray microcalorimeter (LXM), an x-ray microcalorimeter behind an x-ray optic with an angular resolution of 0.5 arc sec and ∼2 sq. m of area at 1 keV. The LXM will provide unparalleled diagnostics of distant extended structures and, in particular, will allow the detailed study of the role of cosmic feedback in the evolution of the Universe. We discuss the baseline design of LXM and some parallel approaches for some of the key technologies. The baseline sensor technology uses transition-edge sensors, but we also consider an alternative approach using metallic magnetic calorimeters. We discuss the requirements for the instrument, the pixel layout, and the baseline readout design, which uses microwave superconducting quantum interference devices and high-electron mobility transistor amplifiers and the cryogenic cooling requirements and strategy for meeting these requirements. For each of these technologies, we discuss the current technology readiness level and our strategy for advancing them to be ready for flight. We also describe the current system design, including the block diagram, and our estimate for the mass, power, and data rate of the instrument.

Simon R. Bandler↗

Anode power deposition in an applied-field segmented anode MPD thruster

Anode heat flux measurements of a water cooled segmented anode applied-field MPD thruster were made to investigate anode heat transfer phenomena. Pure argon and argon-hydrogen mixtures were used as propellants for a variety of thruster currents, propellant mass flow rates, and axial applied magnetic field strengths. The thruster was operated in two modes; with all four segments active, and with two of the segments floating. In addition, thrust and specific impulse were determined for each operating condition. The results show that the heat flux to the anode increases monotonically with axial magnetic field strength and thruster current. Between 50 and 75 percent of the anode heat flux is transported by the current carrying electrons. Convective and radiative heat transfer account for the remaining portion of the power deposited in the anode. The addition of hydrogen to the argon propellant results in the reduction of the fraction of anode power deposited by the anode fall to a level equivalent to that deposited by convection and radiation.

Myers, R. M.↗