Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pointing control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Topological and symmetry-enriched random quantum critical points

In this work, we study how symmetry can enrich strong-randomness quantum critical points and phases, and lead to robust topological edge modes coexisting with critical bulk fluctuations. These are the disordered analogs of gapless topological phases. Using real-space and density matrix renormalization group approaches, we analyze the boundary and bulk critical behavior of such symmetry-enriched random quantum spin chains. We uncover a new class of symmetry-enriched infinite randomness fixed points: while local bulk properties are indistinguishable from conventional random singlet phases, nonlocal observables, and boundary critical behavior are controlled by a different renormalization group fixed point. We also illustrate how such new quantum critical points emerge naturally in Floquet systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Learning Provably Stable Local Volt/Var Controllers for Efficient Network Operation

Here this paper develops a data-driven framework to synthesize local Volt/Var control strategies for distributed energy resources (DERs) in power distribution grids (DGs). Aiming to improve DG operational efficiency, as quantified by a generic optimal reactive power flow (ORPF) problem, we propose a two-stage approach. The first stage involves learning the manifold of optimal operating points determined by an ORPF instance. To synthesize local Volt/Var controllers, the learning task is partitioned into learning local surrogates (one per DER) of the optimal manifold with voltage input and reactive power output. Since these surrogates characterize efficient DG operating points, in the second stage, we develop local control schemes that steer the DG to these operating points. We identify the conditions on the surrogates and control parameters to ensure that the locally acting controllers collectively converge, in a global asymptotic sense, to a DG operating point agreeing with the local surrogates. We use neural networks to model the surrogates and enforce the identified conditions in the training phase. AC power flow simulations on the IEEE 37-bus network empirically bolster the theoretical stability guarantees obtained under linearized power flow assumptions. The tests further highlight the optimality improvement compared to prevalent benchmark methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand Flexibility Controls Library using Semantics (DFLEXLIBS) v0.1

DFLEXLIBS is a library/repository of HVAC-based demand flexibility control applications developed using Python. The library is based on portable control applications that exclusively contain control logic and are abstract to building details, such as point names and communication protocols. The library leverages semantic models and control platform-oriented interfaces to configure and run the controls in specific buildings. To date, the library contains two applications and two interfaces (for BOPTEST and VOLTTRON) and has been demonstrated in five heterogeneous buildings.

Paul, Lazlo↗

Interaction-driven quantum anomalous Hall insulator in a Dirac semimetal

Here, the interaction-driven quantum anomalous Hall (QAH) insulator has been sought for a long time in a Dirac semimetal with linear band touching points at the Fermi level. By combining exact diagonalization, density matrix renormalization group, and analytical methods, we study a spinless fermion system on the checkerboard lattice with twofold rotational symmetry, which realizes two Dirac band touching points in the absence of interaction. At weak coupling, the Dirac semimetal is stable. At a finite density-density repulsive interaction, we analyze possible symmetry broken states, and find that an QAH state is stabilized when the interaction strength exceeds the energy scale controlling the separation between the Dirac points. Through numerical simulations, we verify the existence of the QAH phase with spontaneous time-reversal symmetry breaking and quantized Chern number C = 1.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Divertor detachment and heat exhaust mitigation control in KSTAR with tungsten divertor

KSTAR has recently undergone an upgrade to use a new tungsten divertor to run experiments in ITER-relevant scenarios. Even with a high melting point of tungsten, it is important to control the heat flux impinging on tungsten divertor targets to minimize sputtering and contamination of the core plasma. Heat flux on the divertor is often controlled by increasing the degree of detachment of scrape-off layer plasma from the target plates. In this work, we have demonstrated successful divertor detachment and heat exhaust dissipation control experiments using two different methods. The first method uses attachment fraction as a control variable which is estimated using ion saturation current measurements from embedded Langmuir probes in the divertor. The second method uses a novel machine-learning-based surrogate model of 2D UEDGE simulation database, DivControlNN. We demonstrated running inference operation of DivControlNN in realtime to estimate heat flux at the divertor and use it as the control variable in a feedback loop with impurity gas flow. We present interesting insights from these experiments including a systematic approach to tuning controllers and discuss future improvements in the control infrastructure and control variables for future burning plasma experiments.

KSTAR tungsten divertor operations↗

Report for 2.2.1 Task 5: Develop and Document a State-Based Alarm System for a Nuclear Power Plant Control Room Using Machine Learning

Idaho National Laboratory (INL) has contracted IFE to support human factors research and the development of leading-edge technology to support control room operators as the U.S. fleet undergoes modernization and digitalization in legacy plants and control rooms. As the nuclear industry starts to shift to more digital controls and systems, these upgrades provide more information to the main control room in the form of digital signals and values. Also, an increase in the number of alarms points is provided by the vendors. New digital control rooms shift from main control boards to soft controls, and alarm panels to a single display. This change to a single display has created a problem of alarm waterfall, a situation in which the addition of new alarm points causes an overload of information to the operator during either a plant disturbance or other than normal full power operations. IFE’s goal is to find a workable solution to assist operators in both handling and understanding incoming alarms during emergency situations under these waterfall conditions.

99 GENERAL AND MISCELLANEOUS↗

WEC fault modelling and condition monitoring: A graph-theoretic approach

The nature of wave resources usually requires wave energy converter (WEC) components to handle peak loads (i.e., torques, forces, and powers) that are many times greater than their average loads, accelerating equipment degradation. Moreover, due to their isolated nature and harsh operating environment, WEC systems are projected to possess high operations and maintenance (O&M) cost, i.e., around 27% of their leveled cost of energy. As such, developing techniques to mitigate these costs through the application of condition monitoring and fault tolerant control will significantly impact the economic feasibility of grid connected WEC power. Toward this goal, models of faulty components are developed in the open source modeling platform, WEC-Sim, to estimate the performance and measurable states of a WEC operating with likely device and sensor failures. Two types of faulty component models are then applied to a point absorber WEC model with basic controller damping and spring forces. Resulting changes in device behavior are recorded as a benchmark, and a graph-theoretic approach is proposed for fault detection and identification utilizing multivariate time series. Simulation results demonstrate that these faults can greatly affect the WEC performance, and that the proposed method can effectively detect and classify different types of faults.

16 TIDAL AND WAVE POWER↗

Flexible Resource Scheduler for FAST-DERMS (FRS-FASTDERMS) v0.9

The Flexible Resource Scheduler is a hierarchical controller that manages the distributed energy resources in a distribution substation or distribution feeder to provide a firm commitment of power flow at the substation or feeder head to be scheduled in transmission-level markets as an aggregated demand resource. It is the reference controller for the FAST-DERMS Architecture, developed in tandem with the architecture under the DOE FAST-DERMS project. It is comprised of a day-ahead stochastic optimization, which schedules substation power flow and reserves, a intra-hour MPC, which generates dispatch base points for DER, and a real-time PID controller maintaining that dispatches DER to maintain the substation power around the base points. The repository also includes a representative aggregator controller, and all of the necessary components to run a simulation using PNNL's GridAPPS-D software with the controller.

MacDonald, Jason [Lawrence Berkeley National Labor↗

Enabling integrated AI control on DIII-D: a control system design with state-of-the-art experiments

We present the design and application of a general algorithm for Prediction And Control using MAchiNe learning (PACMAN) in DIII-D. Machine learning (ML)-based predictors and controllers have shown great promise in achieving regimes in which traditional controllers fail, such as tearing mode (TM) free scenarios, ELM-free scenarios and stable advanced tokamak conditions. The architecture presented here was deployed on DIII-D to facilitate the end-to-end implementation of advanced control experiments, from diagnostic processing to final actuation commands. This paper describes the detailed design of the algorithm and explains the motivation behind each design point. We also describe several successful ML control experiments in DIII-D using this algorithm, including a reinforcement learning controller targeting advanced non-inductive plasmas, a wide-pedestal quiescent H-mode ELM predictor, an Alfvén Eigenmode controller, a Model Predictive Control plasma profile controller and a state-machine TM predictor-controller. There is also discussion on guiding principles for real-time ML controller design and implementation.

machine learning↗

Advances in physics and applications of 3D magnetic perturbations on the J-TEXT tokamak

In the last two years, three major technical improvements have been made on J-TEXT in supporting of the expanded operation regions and diagnostic capabilities. (1) The successful commission of the 105 GHz/500 kW/1 s electron cyclotron resonance heating (ECRH) system increasing the core electron temperature from 0.9 keV up to around 1.5 keV. (2) The poloidal divertor configuration with an X-point in the high-field side has been achieved. In particular, the 400 kW electron cyclotron wave has also been successfully injected into the diverted plasma. (3) A 256-channel electron cyclotron emission imaging diagnostic system and two sets of four-channel Doppler backscattering diagnostics have been successfully developed on J-TEXT, allowing detailed measurement of the electron temperature and density fluctuations for turbulence and MHD research. The locked mode (LM), especially the 2/1 LM, is one of the biggest threats to the plasma operation. Both the thresholds of 2/1 and 3/1 LM are observed to vary non-monotonically on electron density. The electrode biasing was applied successfully to unlock the LM from either a rotating or static resonant magnetic perturbation (RMP) field. In the presence of 2/1 LM, three kinds of standing wave (SW) structures have been observed to share a similar connection to the island structure, i.e. the nodes of the SWs locate around the O- or X-points of the 2/1 island. The control and mitigation of disruption is essential to the safe operation of ITER, and it has been systematically studied by applying a RMP field, massive gas injection (MGI) and shattered pellet injection on J-TEXT. When the RMP-induced 2/1 LM is larger than a critical width, the MGI shutdown process can be significantly influenced. If the phase difference between the O-point of LM and the MGI valve is +90° (or –90°), the penetration depth and the assimilation of impurities can be enhanced (or suppressed) during the pre-thermal quench (TQ) phase and result in a faster (or slower) TQ. A secondary MGI can also suppress the runaway electron (RE) generation, if the additional high-Z impurity gas arrives at the plasma edge before TQ. When the secondary MGI has been applied after the formation of the RE current plateau, the RE current can be dissipated, and the dissipation rate increases with the injected impurity quantity but saturates with a maximum of 28 MA s –1 . The non-local transport is experimentally observed in the ion transport channel. The electron thermal diffusivity significantly increases with the ECRH power. Theoretical work shows that significant intrinsic current can be driven by electromagnetic turbulence, and the robust formation mechanism of the E × B staircase is identified from the Hasegawa–Wakatani system.

divertor↗

Fairness-Aware Distributed Energy Coordination for Voltage Regulation in Power Distribution Systems

The accelerating deployment of solar photovoltaics into low-voltage distribution networks can cause reverse power flow and overvoltage problems. However, if coordinated properly, the real and reactive power flexibility of these resources enables distribution operators to manage their networks more efficiently. Existing literature is rich in droop-based control (Volt-Watt and Volt-VAr) and optimization-based distributed energy coordination for four-quadrant control of photovoltaics to prevent overvoltage issues. While optimal coordination can effectively mitigate overvoltage, it tends to treat resources at sensitive parts of the grid unfairly. Here, to address this concern, we propose a distributed optimal power flow formulation that incorporates fairness in curtailing photovoltaic generation and utilizes the reactive power capability of smart inverters. The proposed distributed formulation allows for scalable resource aggregation that can be leveraged to achieve fairness within a certain segment of the grid and/or fairness across the entire network. Fair curtailment of photovoltaic systems is demonstrated with aggregation at each of two layers in a distribution network: 1) area-level fairness and 2) feeder-level fairness. To explore the trade-off between fairness and optimal utilization, the fairness-aware control actions are compared against the performance of a centralized controller that aims to maximize the aggregate PV generation without incorporating fairness. Simulation results show that introducing area-level fairness increased curtailment by 0.0101 percentage points and feeder-level fairness increased curtailment by 0.0458 percentage points compared to a fairness-agnostic control.

Poudel, Shiva↗

Additional Degree of Freedom for WEC Model

'Additional Degree of Freedom for WEC' - WEC-Sim numerical model from RFTS 1 TEAMER project. An increase in wave energy converter (WEC) efficiency requires not only consideration of the nonlinear effects in the WEC dynamics and the power take-off (PTO) mechanisms, but also more integrated treatment of the whole system, i.e., the buoy dynamics, the PTO system, and the control strategy. It results in an optimization formulation that has a nonquadratic and nonstandard cost functional. This model presents the application of real-time nonlinear model predictive controller (NMPC) to two degrees of freedom point absorber type WEC with highly nonlinear PTO characteristics. The nonlinear effects, such as the fluid viscous drag, are also included in the plant dynamics. The controller may be implemented on a real-time target machine, and the WEC device is emulated in real-time using the WECSIM toolbox. Please see the ‘ReadMe’ within the root directory for an explanation of how to set-up and run the model. An article covering the development of this model is attached as "Real-Time Nonlinear Model Predictive Controller for Multiple Degrees of Freedom Wave Energy Converters with Non-Ideal Power Take-Off"

16 TIDAL AND WAVE POWER↗

Real-Time Nonlinear Model Predictive Controller for Multiple Degrees of Freedom Wave Energy Converters with Non-Ideal Power Take-Off

An increase in wave energy converter (WEC) efficiency requires not only consideration of the nonlinear effects in the WEC dynamics and the power take-off (PTO) mechanisms, but also more integrated treatment of the whole system, i.e., the buoy dynamics, the PTO system, and the control strategy. It results in an optimization formulation that has a nonquadratic and nonstandard cost functional. This article presents the application of real-time nonlinear model predictive controller (NMPC) to two degrees of freedom point absorber type WEC with highly nonlinear PTO characteristics. The nonlinear effects, such as the fluid viscous drag, are also included in the plant dynamics. The controller is implemented on a real-time target machine, and the WEC device is emulated in real-time using the WECSIM toolbox. The results for the successful performance of the design are presented for irregular waves under linear and nonlinear hydrodynamic conditions.

Haider, Ali S. (ORCID:0000000246513157)↗

Quantum simulation of an exotic quantum critical point in a two-site charge Kondo circuit

Tuning a material to the cusp between two distinct ground states can produce physical properties that are unlike those in either of the neighbouring phases. Advances in the fabrication and control of quantum systems have raised the tantalizing prospect of artificial quantum simulators that can capture such behaviour. A tunable array of coupled qubits should have an appropriately rich phase diagram, but realizing such a system with either tunnel-coupled semiconductor quantum dots or metal nanostructures has proven difficult. The challenge for scaling up to clusters or lattices is to ensure that each element behaves essentially identically and that the coupling between elements is uniform, while also maintaining tunability of the interactions. Here we study a nanoelectronic circuit comprising two coupled hybrid metal–semiconductor islands, combining the strengths of both materials to form a potentially scalable platform. The semiconductor component allows for controllable inter-site couplings at quantum point contacts, while the metal component’s effective continuum of states means that different sites can be made equivalent by tuning local potentials. The couplings afforded by this architecture can realize an unusual quantum critical point resulting from frustrated Kondo interactions. In this study, the observed critical behaviour matches theoretical predictions, verifying the success of our experimental quantum simulation.

36 MATERIALS SCIENCE↗

Computational Fluid Dynamics-Based Modeling of Methane Flows Around Oil and Gas Equipment

Recent studies estimate that emissions from oil and gas production facilities contribute between 20 and 50% of the total methane ( CH 4 ) emitted in the US; therefore, quantifying and reducing these emissions are crucial for achieving climate goals. Methane quantification depends on both measuring methane concentrations and converting them to emissions through a modeling framework. Currently, simple atmospheric dispersion models are primarily used to quantify emissions and concentrations, but these estimates are highly uncertain when quantifying emissions from complex aerodynamic sources, such as oil and gas facilities. This investigation used a CFD modeling approach, which can account for aerodynamic complexity but has hitherto not been used to model methane concentrations downwind of a methane release of a known rate, and compared it against in situ measurements. High-time-resolution (1 Hz) methane concentration and meteorological data were measured during experiments conducted at the METEC on 21 March and 11 July 2024. The METEC site configuration, measured wind data, and controlled emission rates were used as input for the CONVERGE CFD model to model downwind CH 4 concentration. The modeling was carried out between 20 and 70 m, from two different points of release in two separate controlled-release experiments, one from a separator and another from a wellhead. In these experiments, we found that the CFD model could predict the CH 4 concentrations downwind of the release to a good degree. The model was evaluated on multiple metrics to assess its performance in estimating methane concentrations at typical fence line distances (∼30 m). These results help us to understand external flows and the ability of CFD models to predict downwind concentrations in aerodynamically complex environments.

03 NATURAL GAS↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A machine learning-based fast frequency response control for a VSC-HVDC system

An HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation. However, most of existing HVDC frequency control strategies are coupled with system primary frequency control and secondary frequency control. Since the traditional system frequency control is dominated by the thermal generators, the advantage of the fast response of the HVDC system is not made fully used. The development of a frequency response estimation based on a machine learning algorithm provides another approach to improve the frequency response capability of the HVDC system. Different from other frequency deviation tracking strategies, a machine learning based HVDC frequency response control can directly increase the power flow of a HVDC system by estimation of the system generator or load lost. In this paper, a fast frequency response control using a HVDC system for a large power system disturbance based on the multivariate random forest regression (MRFR) algorithm is proposed. The simulation is carried out with an integrated power system model based on the North American interconnections. The simulation results indicate that the proposed MRFR based frequency response control can significantly improve the frequency low point during an event, while stabilizing the frequency in advance.

42 ENGINEERING↗