Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Smart Focal-Plane Technology for Micro-Instruments and Micro-Rovers

It is inevitable that micro-instruments and micro-rovers for space exploration will contain one or more focal-plane arrays for imaging spectroscopy or navigation. In this paper, we explore the state-if-the-art in focal-plane technology for visible sensors. Also discussed is present research activity in advanced focal-plane technology with particular emphasis on the development of smart sensors. The paper concludes with a discussion of possible future directions for the advancement of the technology.

Fossum, Eric R.↗

Development of a 1K x 1K GaAs QWIP Far IR Imaging Array

In the on-going evolution of GaAs Quantum Well Infrared Photodetectors (QWIPs) we have developed a 1,024 x 1,024 (1K x1K), 8.4-9 microns infrared focal plane array (FPA). This 1 megapixel detector array is a hybrid using the Rockwell TCM 8050 silicon readout integrated circuit (ROIC) bump bonded to a GaAs QWIP array fabricated jointly by engineers at the Goddard Space Flight Center (GSFC) and the Army Research Laboratory (ARL). The finished hybrid is thinned at the Jet Propulsion Lab. Prior to this development the largest format array was a 512 x 640 FPA. We have integrated the 1K x 1K array into an imaging camera system and performed tests over the 40K-90K temperature range achieving BLIP performance at an operating temperature of 76K (f/2 camera system). The GaAs array is relatively easy to fabricate once the superlattice structure of the quantum wells has been defined and grown. The overall arrays costs are currently dominated by the costs associated with the silicon readout since the GaAs array fabrication is based on high yield, well-established GaAs processing capabilities. In this paper we will present the first results of our 1K x 1K QWIP array development including fabrication methodology, test data and our imaging results.

Jhabvala, M.↗

NASA Tech Briefs, September 2007

Topics covered include; Rapid Fabrication of Carbide Matrix/Carbon Fiber Composites; Coating Thermoelectric Devices To Suppress Sublimation; Ultrahigh-Temperature Ceramics; Improved C/SiC Ceramic Composites Made Using PIP; Coating Carbon Fibers With Platinum; Two-Band, Low-Loss Microwave Window; MCM Polarimetric Radiometers for Planar Arrays; Aperture-Coupled Thin-Membrane L-Band Antenna; WGM-Based Photonic Local Oscillators and Modulators; Focal-Plane Arrays of Quantum-Dot Infrared Photodetectors; Laser Range and Bearing Finder With No Moving Parts; Microrectenna: A Terahertz Antenna and Rectifier on a Chip; Miniature L-Band Radar Transceiver; Robotic Vision-Based Localization in an Urban Environment; Programs for Testing an SSME-Monitoring System; Cathodoluminescent Source of Intense White Light; Displaying and Analyzing Antenna Radiation Patterns; Payload Operations Support Team Tools; Space-Shuttle Emulator Software; Soft Real-Time PID Control on a VME Computer; Analyzing Radio-Frequency Coverage for the ISS; Nanorod-Based Fast-Response Pressure-Sensitive Paints; Capacitors Would Help Protect Against Hypervelocity Impacts; Diaphragm Pump With Resonant Piezoelectric Drive; Improved Quick-Release Pin Mechanism; Designing Rolling-Element Bearings; Reverse-Tangent Injection in a Centrifugal Compressor; Inertial Measurements for Aero-assisted Navigation (IMAN); Analysis of Complex Valve and Feed Systems; Improved Path Planning Onboard the Mars Exploration Rovers; Robust, Flexible Motion Control for the Mars Explorer Rovers; Solar Sail Spaceflight Simulation; Fluorine-Based DRIE of Fused Silica; Mechanical Alloying for Making Thermoelectric Compounds; Process for High-Rate Fabrication of Alumina Nanotemplates; Electroform/Plasma-Spray Laminates for X-Ray Optics; An Automated Flying-Insect Detection System; Calligraphic Poling of Ferroelectric Material; Blackbody Cavity for Calibrations at 200 to 273 K; KML Super Overlay to WMS Translator; High-Performance Tiled WMS and KML Web Server; Modeling of Radiative Transfer in Protostellar Disks; Composite Pulse Tube; Photometric Calibration of Consumer Video Cameras; Criterion for Identifying Vortices in High- Pressure Flows; Amplified Thermionic Cooling Using Arrays of Nanowires; Delamination-Indicating Thermal Barrier Coatings; Preventing Raman Lasing in High-Q WGM Resonators; Procedures for Tuning a Multiresonator Photonic Filter; Robust Mapping of Incoherent Fiber-Optic Bundles; Extended-Range Ultrarefractive 1D Photonic Crystal Prisms; Rapid Analysis of Mass Distribution of Radiation Shielding; Modeling Magnetic Properties in EZTB; Deep Space Network Antenna Logic Controller; Modeling Carbon and Hydrocarbon Molecular Structures in EZTB; BigView Image Viewing on Tiled Displays; and Imaging Sensor Flight and Test Equipment Software.

Source record↗

Proton Radiation Effects on HgCdTe Avalanche Photodiode Detectors

Space radiation damage and proton induced transient effects were evaluated on 4.4 μm cutoff HgCdTe avalanche photodiode (APD) arrays developed by Leonardo DRS. Device performances as a function of total dose up to 100 krad (Si) were measured with ~60 MeV protons on 3 types of APD samples: 4x4 pixel APD fanout arrays with and without connection to a read-out integrated circuit (ROIC), and a 2x8 pixel photon counting APD focal plane array (FPA). A gamma-ray test was also conducted to study ionization effects. Both APD arrays exhibited a small decrease in the quantum efficiency and a linear increase in the dark current with the proton fluence. The 2x8 pixel photon counting FPA also exhibited an increase in the dark count rate with proton dose. After the proton irradiation and an overnight room temperature warm-up, the APD dark currents at 80 K increased significantly in both types of APD arrays. All radiation damage to these HgCdTe APD arrays annealed out after baking them at >85 °C for several hours. Transient protons through the devices were found to cause large pulses at the detector output but recover within 1 μs.

Xiaoli Sun↗

The Fourier-Kelvin Stellar Interferometer Mission Concept

The Fourier-Kelvin Stellar Interferometer (FKSI) is a mission concept for an imaging interferometer for the mid-infrared spectral region (5-30 microns). FKSI is conceived as a scientific and technological precursor to TPF as well as Space Infrared Interferometric Telescope (SPIRIT), Submillimeter Probe Evolution of Cosmic Structure (SPECS), and Single Aperture for Infrared Observatory (SAFIR). It will also be a high angular resolution system complementary to Next Generation Space Telescope (NGST). The scientific emphasis of the mission is on the evolution of protostellar systems, from just after the collapse of the precursor molecular cloud core, through the formation of the disk surrounding the protostar, the formation of planets in the disk, and eventual dispersal of the disk material. FKSI will also search for brown dwarfs and Jupiter mass and smaller planets, and could also play a very powerful role in the investigation of the structure of active galactic nuclei and extra-galactic star formation. We are in the process of studying alternative interferometer architectures and beam combination techniques, and evaluating the relevant science and technology tradeoffs. Some of the technical challenges include the development of the cryocooler systems necessary for the telescopes and focal plane array, light and stiff but well-damped truss systems to support the telescopes, and lightweight and coolable optical telescopes. The goal of the design study is to determine if a mid-infrared interferometry mission can be performed within the cost and schedule requirements of a Discovery class mission. At the present time we envision the FKSI as comprised of five one meter diameter telescopes arranged along a truss structure in a linear non-redundant array, cooled to 35 K. A maximum baseline of 20 meters gives a nominal resolution of 26 mas at 5 microns. Using a Fizeau beam combination technique, a simple focal plane camera could be used to obtain both Fourier and spectral data simultaneously for a given orientation of the array. The spacecraft will be rotated to give sufficient Fourier data to reconstruct complex images of a broad range of astrophysical sources.

Danchi, W. C.↗

The Fourier-Kelvin Stellar Interferometer (FKSI): A Discovery Class TPF/DARWIN Pathfinder Mission Concept

The Fourier-Kelvin Stellar Interferometer (FKSI) is a mission concept for an imaging and nulling interferometer for the mid-infrared spectral region (5-30 microns). FKSI is conceived as a scientific and technological pathfinder to TPF/DARWIN as well as SPIRIT, SPECS, and SAFIR. It will also be a high angular resolution system complementary to NGST. The scientific emphasis of the mission is on the evolution of protostellar systems, from just after the collapse of the precursor molecular cloud core, through the formation of the disk surrounding the protostar, the formation of planets in the disk, and eventual dispersal of the disk material. FKSI will also search for brown dwarfs and Jupiter mass and smaller planets, and could also play a very powerful role in the investigation of the structure of active galactic nuclei and extra-galactic star formation. We have been studying alternative interferometer architectures and beam combination techniques, and evaluating the relevant science and technology tradeoffs. Some of the technical challenges include the development of the cryocooler systems necessary for the telescopes and focal plane array, light and stiff but well-damped truss systems to support the telescopes, and lightweight and coolable optical telescopes. We present results of detailed design studies of the FKSI starting with a design consisting of five one meter diameter telescopes arranged along a truss structure in a linear non-redundant array, cooled to 35 K. A maximum baseline of 20 meters gives a nominal resolution of 26 mas at 5 microns. Using a Fizeau beam combination technique, a simple focal plane camera could be used to obtain both Fourier and spectral data simultaneously for a given orientation of the array. The spacecraft will be rotated to give sufficient Fourier data to reconstruct complex images of a broad range of astrophysical sources. Alternative and simpler three and two telescope designs emphasizing nulling and spectroscopy also have been investigated and will be discussed.

Danchi, W. C.↗

Analysis of rotationally symmetric arrays of apertures on conducting spherical surfaces

Rotationally symmetric arrays of circular waveguide fed apertures on conducting spherical surfaces have been analyzed. Representation of the outside electromagnetic fields in terms of spherical transmission line modes permit the array analysis to be viewed as a spherical waveguide junction discontinuity problem. The apertures, in general, carry dual polarized circular waveguide TE11 modes. Two independent formulations - the unit cell method and the eigenexcitation method that take rotational symmetry into account - are developed and are checked against each other numerically for computational accuracy. These two formulations are analytically linked as discrete Fourier series pairs. It is seen that mutual coupling along the array decays more rapidly when the polarization of excitation is perpendicular to the array plane than when it is parallel to it. This analysis has been applied in the performance analysis of the Dome Lens phased array radar antenna.

Bondyopadhyay, Probir K.↗

Light-concentrating microcone array for improving performance of infrared imaging devices

Light-harvesting low-index (n=1.6) microconical arrays are proposed for increasing the sensitivity and the signal-to-noise ratio (SNR) of mid-wave infrared (MWIR) focal plane arrays (FPAs) used in thermal cameras. Numerical modeling showed a 3-D Power enhancement factor ~ 50 in MWIR for 10° tapered microcones with Dt/Db = 60 μm/8μm and h=150μm, where Dt and Db are the top and bottom diameters of microcones, respectively. Such microconical arrays were fabricated in photoresist by using a nanoscribe tool directly on top of the front-illuminated Ni/Si Schottky-barrier, and three-fold enhancement in the photocurrent response was observed. The proposed approach permits increase of the SNR and the operation temperature of the MWIR imaging devices.

Astratov, Vasily N.↗

Active pixel sensor array with multiresolution readout

An imaging device formed as a monolithic complementary metal oxide semiconductor integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node. There is also a readout circuit, part of which can be disposed at the bottom of each column of cells and be common to all the cells in the column. The imaging device can also include an electronic shutter formed on the substrate adjacent the photogate, and/or a storage section to allow for simultaneous integration. In addition, the imaging device can include a multiresolution imaging circuit to provide images of varying resolution. The multiresolution circuit could also be employed in an array where the photosensitive portion of each pixel cell is a photodiode. This latter embodiment could further be modified to facilitate low light imaging.

Fossum, Eric R.↗

Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph

A single-pixel prototype of a W-band detector module with a digital back-end was developed to serve as a building block for large focal-plane arrays of monolithic millimeter-wave integrated circuit (MMIC) detectors. The module uses low-noise amplifiers, diode-based mixers, and a WR10 waveguide input with a coaxial local oscillator. State-of-the-art InP HEMT (high electron mobility transistor) MMIC amplifiers at the front end provide approximately 40 dB of gain. The measured noise temperature of the module, at an ambient temperature of 300 K, was found to be as low as 450 K at 95 GHz. The modules will be used to develop multiple instruments for astrophysics radio telescopes, both on the ground and in space. The prototype is being used by Stanford University to characterize noise performance at cryogenic temperatures. The goal is to achieve a 30-50 K noise temperature around 90 GHz when cooled to a 20 K ambient temperature. Further developments include characterization of the IF in-phase (I) and quadrature (Q) signals as a function of frequency to check amplitude and phase; replacing the InP low-noise amplifiers with state-of-the-art 35-nm-gate-length NGC low-noise amplifiers; interfacing the front-end module with a digital back-end spectrometer; and developing a scheme for local oscillator and IF distribution in a future array. While this MMIC is being developed for use in radio astronomy, it has the potential for use in other industries. Applications include automotive radar (both transmitters and receivers), communication links, radar systems for collision avoidance, production monitors, ground-penetrating sensors, and wireless personal networks.

Kangaslahti, Pekka P.↗

NASA Tech Briefs, March 2004

Topics covered include: 1) Advanced Signal Conditioners for Data-Acquisition Systems; 2) Downlink Data Multiplexer; 3) Viewing ISS Data in Real Time via the Internet; 4) Autonomous Environment-Monitoring Networks; 5) Readout of DSN Monitor Data; 6) Parallel-Processing Equalizers for Multi-Gbps Communications; 7) AIN-Based Packaging for SiC High-Temperature Electronics; 8) Software for Optimizing Quality Assurance of Other Software; 9) The TechSat 21 Autonomous Sciencecraft Experiment; 10) Software for Analyzing Laminar-to-Turbulent Flow Transitions; 11) Elastomer Filled With Single-Wall Carbon Nanotubes; 12) Modifying Ship Air-Wake Vortices for Aircraft Operations; 13) Strain-Gauge Measurement of Weight of Fluid in a Tank; 14) Advanced Docking System With Magnetic Initial Capture; 15) Blade-Pitch Control for Quieting Tilt-Rotor Aircraft; 16) Solar Array Panels With Dust-Removal Capability; 17) Aligning Arrays of Lenses and Single-Mode Optical Fibers; 18) Automatic Control of Arc Process for Making Carbon Nanotubes; 19) Curved-Focal-Plane Arrays Using Deformed-Membrane Photodetectors; 20) Role of Meteorology in Flights of a Solar-Powered Airplane; 21) Model of Mixing Layer With Multicomponent Evaporating Drops; 22) Solution-Assisted Optical Contacting; 23) Improved Discrete Approximation of Laplacian of Gaussian; 24) Utilizing Expert Knowledge in Estimating Future STS Costs; 25) Study of Rapid-Regression Liquefying Hybrid Rocket Fuels; and 26) More About the Phase-Synchronized Enhancement Method.

Source record↗

Dual Common Planes for Time Multiplexing of Dual-Color QWIPs

A proposed improved method of externally controlled time multiplexing of the readouts of focal-plane arrays of pairs of stacked quantum-well infrared photodetectors (QWIPs) that operate in different wavelength bands is based on a dual-detector-common-plane circuit configuration. The method would be implemented in a QWIP integrated-circuit chip hybridized with a readout integrated-circuit (ROIC) chip.

Rafol, Sir B.↗

Antennas, Arrays, and Systems for Submillimter-Wave Radio Astronomy

In this paper we present the design and development of a 16-pixel submillimeter-wave array instrument using SIS technology. We show that this instrument concept demonstration and component development dramatically simplifies the fabrication, assembly, and integration of large focal plane arrays at these frequencies. This advancement is enabled by the innovative array architecture with silicon microlens based antenna arrays, highly sensitive SIS mixers at these frequencies, integrated SiGe BiCMOS based low-noise intermediate frequency (IF) amplifiers, and silicon micromachined packaging.

Chattopadhyay, Goutam↗

Design of Si micro-cone light concentrators for heterogeneous integration with MWIR FPAs

Using 3-D finite difference time domain (FDTD) modeling, it is shown that micro-cone arrays obtained by anisotropic wet etching of Si have high potential for concentrating light on compact photodetector mesas of mid-wave infrared (MWIR) focal plane arrays (FPAs). The proposed structures can be heterogeneously integrated with FPAs possessing high quantum efficiency. They can be used to reduce the thermal noise and, potentially, increase the operating temperature of FPAs while maintaining high sensitivity of the photodetectors.

Astratov, Vasily N.↗

The new near-infrared array camera at the University of Rochester

A near-infrared array camera system has been constructed for use in the 1-5 micron region. The camera is based on a 32 x 32 element InSb focal plane array. The performance of most of the individual detectors in the system is found to be comparable to or better than the performance of any single-element InSb detector system currently in use. A thorough description of the camera system and its image processing subsystems is given, and some sample images are provided.

Forrest, W. J.↗

Fast, High-Precision Readout Circuit for Detector Arrays

The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.

Rider, David M.↗

Imaging spectrometer - An advanced multispectral imaging concept

The concept of an imaging spectrometer, which is being studied as a potential Space Shuttle experiment, is evaluated as a 'push-broom' imager that includes a spectrometer to disperse each line of imaging information into its spectral components. Using this instrument, the dispersed energy falls upon a two-dimensional focal plane array that detects both spatial and spectral information. As the line field of view is advanced over the earth by the motion of the spacecraft, the focal plane is read out constantly, which produces 'push-broom' images at multiple wavelengths. Ground instantaneous fields of view of 10 m in the visual and 20 m in the infrared are provided by the system, at a spectral resolution of 20 nm over the range from 0.4-2.5 microns. The system utilizes a triple-pass Schmidt optical system with a mosaic focal plane. A subset of the data stream is selected and encoded for transmission by the use of onboard processing.

Wellman, J. B.↗