At least 271 records · Page 15

Sonar

Sonar contains software for managing a HPC performance-monitoring software stack. This includes streaming data into a distributed Kafka message queue, storing/querying from a distributed Cassandra database, and front-end tools for secure access, visualization, and analytics of facility-wide performance data.

Gimenez, AlfredoA.↗

Knowledge-based monitoring of the pointing control system on the Hubble space telescope

A knowledge-based system for the real time monitoring of telemetry data from the Pointing and Control System (PCS) of the Hubble Space Telescope (HST) that enables the retention of design expertise throughout the three decade project lifespan by means other than personnel and documentation is described. The system will monitor performance, vehicle status, success or failure of various maneuvers, and in some cases diagnose problems and recommend corrective actions using a knowledge base built using mission scenarios and the more than 4,500 telemetry monitors from the HST.

Dunham, Larry L.↗

Electrical Resistivity Tomography Monitoring of In Situ Soil Flushing at the Hanford 100-K East Area: 100KE Soil Flushing Monitoring

Former operations in the 100-KE Area at the Hanford Site resulted in vadose zone hexavalent chromium that provides a source of groundwater contamination. Previous efforts to remediate vadose zone chromium involved excavation and offsite treatment of contaminated soils. Although much of the chromium was removed, contamination still exists in native soil between the water table and the bottom of the pit, which has since been backfilled. In-situ soil flushing was tested at the 100-KE Area to accelerate the removal of the remaining hexavalent chromium in the vadose zone. Soil flushing works by applying clean flush water at the surface, which mobilizes and transports chromium as it migrates downward to the water table. Once the chromium reaches the water table, it is hydraulically contained, extracted, and treated through pump and treat operations. The efficacy of soil flushing is directly related to the volume of clean water that infiltrates through contaminated soils. Therefore, performance monitoring requires and understanding of flush water migration through the vadose zone. It is challenging to comprehensively assess soil flushing performance via borehole access due to the limited volume of investigation afforded by a given wellbore. As an alternative, 3D time-lapse electrical resistivity tomography (ERT) was tested as a method of monitoring the distribution of flush water over time within the vadose zone. ERT is a method of imaging the bulk electrical conductivity of the subsurface, which is highly dependent on water saturation levels in unconsolidated and unsaturated sediments. Thus, the timing and location of changes in bulk conductivity caused by soil flushing can be used to infer flush water migration pathways. In this report we present results of 3D time-lapse ERT imaging during two separate soil flushing campaigns conducted during the spring and summer months of 2022 and 2023. Results show generally that: 1) Pit backfill materials appear to nominally have larger permeability than native soils. Consequently, the boundary between pit backfill and native soil had a significant impact on flush water migration, causing some flush water to migrate along the pit boundary to the bottom of the pit. 2) Non-uniform flows, likely caused by variations in hydrogeologic properties, developed in the pit backfill materials, resulting in uneven flush water distribution on the southern margin of the soil flushing zone. 3) Redistribution of water at the interface between backfill materials and Hanford formation materials likely facilitated elevated and uniform distribution of flush water within native soils beneath the deeper parts of the pit boundary beneath the center of the flush zone, which presumably overlie soils with elevated chromium contamination. These areas appear to have been infiltrated by higher volumes of flush water than the northern and southern margins of the flush zone. 4) In comparison to 2022, high flush water application rates significantly improved flush water distribution throughout the target flushing zone. 5) Imaging resolution was limited to a depth of approximate 20 meters below the land surface, due primarily to limitations on the lateral extent of the surface ERT array. The ~10 m region of the vadose zone between approximately 130 meters elevation and the water table at approximately 120 meters elevation was unresolved.

100 Area↗

Space shuttle propulsion systems on-board checkout and monitoring system development study (extension). Volume 1: Summary and technical results

An analysis was conducted of the space shuttle propulsion systems to define the onboard checkout and monitoring function. A baseline space shuttle vehicle and mission were used to establish the techniques and approach for defining the requirements. The requirements were analyzed to formulate criteria for implementing the functions of preflight checkout, performance monitoring, fault isolation, emergency detection, display, data storage, postflight evaluation, and maintenance retest.

Source record↗

QMI: Rising to the Space Station Design Challenge

The Quench Module Insert (QMI) materials processing furnace is being designed to operate for 8000 hours over four years on the International Space Station (ISS) as part of the first Materials Science Research Rack (MSRR-1) of the Materials Science Research Facility (MSRF). The Bridgman-type furnace is being built for the directional solidification processing of metals and alloys in the microgravity environment of space. Most notably it will be used for processing aluminum and related alloys. Designing for the space station environment presents intriguing design challenges in the form of a ten-year life requirement coupled with both limited opportunities for maintenance and resource constraints in the form of limited power and space. The long life requirement has driven the design of several features in the furnace, including the design of the heater core, the selection and placement of the thermocouples, overall performance monitoring, and the design of the chill block. The power and space limitations have been addressed through a compact furnace design using efficient vacuum insulation. Details on these design features, as well as development test performance results to date, are presented.

Carswell, W. E.↗

Field Test Bed for Vadose-Zone Monitoring Approaches - 20404

In the Central Plateau at the U.S. Department of Energy Hanford Site, a large inventory of contaminants resides in unsaturated sediments within the approximately 100-meter-thick vadose zone, posing a potential continuing risk to groundwater. Vadose zone remedies used to address these contaminants will require performance monitoring to provide feedback during implementation and for long-term verification that remedial action objectives have been met. Passive approaches may also need long-term monitoring to demonstrate that the flux of contaminants from the vadose zone to the groundwater are below thresholds established to meet groundwater protection goals. Collection of physical (e.g., groundwater or sediment) samples is a common method for identifying contaminant concentration distributions, but this approach is limited by the number of locations and the frequency with which data can be collected. In situ vadose zone measurements have evolved over the past few years to include key measurements of water content, soil water pressure, temperature, and chemical concentration. However, the current generation of sensors is designed for relatively short-term use in near-surface soils or sediments. Geophysical methods have been evolving but are also limited in that they have not been designed for the specific long-term vadose zone monitoring needs at the Hanford Site. Overall, monitoring under unsaturated conditions can be difficult due to the need to install and maintain instrumentation over a large area and depth and the need to identify preferential flow pathways due to geologic and chemical heterogeneities over long periods. Thus, a vadose zone monitoring test bed was initiated to address these challenges and identify cost-effective approaches for implementation and postclosure monitoring of the deep vadose zone. The monitoring test bed is expected to provide valuable field-scale information for the design of vadose zone monitoring systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Wireless Subsurface Microsensors for Health Monitoring of Thermal Protection Systems

Low cost access to space is a primary goal for both NASA and the U.S. aerospace industry. Integrated subsystem health diagnostics is an area where major improvements have been identified for potential implementation into the design of new reusable launch vehicles (RLVS) in order to reduce life cycle costs, increase safety margins and improve mission reliability. A number of efforts are underway to use existing and emerging technologies to establish new methods for vehicle health monitoring on operational vehicles as well as X-vehicles. This paper summarizes a joint effort between several NASA centers and industry partners to develop rapid wireless diagnostic tools for failure management and long-term TPS performance monitoring of thermal protection systems (TPS) on future RLVS. An embedded wireless microsensor suite is being designed to allow rapid subsurface TPS health monitoring and damage assessment. This sensor suite will consist of both passive overlimit sensors and sensors for continuous parameter monitoring in flight. The on-board diagnostic system can be used to radio in maintenance requirements before landing and the data could also be used to assist in design validation for X-vehicles. For a 3rd generation vehicle, wireless diagnostics should be at a stage of technical development that will allow use for intelligent feedback systems for guidance and navigation control applications and can also serve as feedback for TPS that can intelligently adapt to its environment.

Pallix, Joan↗

Diagnosis and Prognosis of Weapon Systems

The Prognostics Framework is a set of software tools with an open architecture that affords a capability to integrate various prognostic software mechanisms and to provide information for operational and battlefield decision-making and logistical planning pertaining to weapon systems. The Prognostics NASA Tech Briefs, February 2005 17 Framework is also a system-level health -management software system that (1) receives data from performance- monitoring and built-in-test sensors and from other prognostic software and (2) processes the received data to derive a diagnosis and a prognosis for a weapon system. This software relates the diagnostic and prognostic information to the overall health of the system, to the ability of the system to perform specific missions, and to needed maintenance actions and maintenance resources. In the development of the Prognostics Framework, effort was focused primarily on extending previously developed model-based diagnostic-reasoning software to add prognostic reasoning capabilities, including capabilities to perform statistical analyses and to utilize information pertaining to deterioration of parts, failure modes, time sensitivity of measured values, mission criticality, historical data, and trends in measurement data. As thus extended, the software offers an overall health-monitoring capability.

Nolan, Mary↗

Accelerating Multiphase Simulations With Denoising Diffusion Model Driven Initializations

This study introduces a hybrid fluid simulation approach that integrates generative diffusion models with physics‐based simulations, aiming at reducing the computational costs of flow simulations while still honoring all the physical properties of interest. Pore‐scale simulations enhance our understanding of applications such as assessing hydrogen and storage efficiency in underground reservoirs. Nevertheless, they are computationally expensive and the presence of non‐unique solutions can require multiple simulations within a single geometry. To overcome the computational cost hurdle, we propose a method that couples generative diffusion models and physics‐based simulations. While training the data‐driven model, we simultaneously generate initial conditions and perform physics‐based simulations using these. This integrated approach enables us to receive real‐time feedback on a single compute node equipped with both CPUs and GPUs. By efficiently managing these processes within a single compute node, we can continuously monitor performance and halt training once the model meets the specified criteria. To test our model, we generate realizations in a real Berea sandstone fracture which shows that our technique is up to 4.4 times faster than commonly used flow simulation initializations.

36 MATERIALS SCIENCE↗

Converter/Compressor Building Solid Waste Management Unit (SWMU) #89 Monitoring Well 21 Area Interim Measure Work Plan

This Work Plan details the approach and design for the Interim Measure (IM) to remediate groundwater within the MW21 Area where VOC concentrations exceed Florida Department of Environmental Protection Natural Attenuation Default Concentrations. The IM includes in-situ bioremediation via injection of emulsified vegetable oil (EVO) and emulsified zero-valent iron (EZVI). The in-situ bioremediation technology consists of injecting an electron donor substrate into the subsurface to promote microbial breakdown of VOCs. The EVO injections for this IM are designed based on the use of Provectus ERD-CH4, which is a vegetable oil/carbon substrate mixture. The EZVI injections for this IM are designed based on the use of Provectus EZVI-CH4. The IM treatment layout consists of nine injection locations of EVO at approximately 10-foot radius of influence (ROI) and three injections locations of EZVI at approximately 6-foot ROI. The injection method will be direct push using a DPT rig. The overall injection depths range from 7 to 17 ft bls. The 7 ft bls top depth is designed to be 2 ft below the water table to prevent substrates from reaching the top of the water table. Injections are planned to be implemented using 2 ft intervals and will take place using a bottom-up approach to 2 ft below the water table. This work plan further describes the IM design, injection calculations, performance monitoring plan, and provides an injection layout. Revision 1 of this Work Plan includes quarterly performance sampling during Year 1 in accordance with F.A.C. 62-780. These changes are reflected in Section 7 and Table 2 of the Work Plan.

Mark J Jonnet↗

Science Data Report for the Optical Properties Monitor (OPM) Experiment

This science data report describes the Optical Properties Monitor (OPM) experiment and the data gathered during its 9-mo exposure on the Mir space station. Three independent optical instruments made up OPM: an integrating sphere spectral reflectometer, vacuum ultraviolet spectrometer, and a total integrated scatter instrument. Selected materials were exposed to the low-Earth orbit, and their performance monitored in situ by the OPM instruments. Coinvestigators from four NASA Centers, five International Space Station contractors, one university, two Department of Defense organizations, and the Russian space company, Energia, contributed samples to this experiment. These materials included a number of thermal control coatings, optical materials, polymeric films, nanocomposites, and other state-of-the-art materials. Degradation of some materials, including aluminum conversion coatings and Beta cloth, was greater than expected. The OPM experiment was launched aboard the Space Shuttle on mission STS-81 in January 1997 and transferred to the Mir space station. An extravehicular activity (EVA) was performed in April 1997 to attach the OPM experiment to the outside of the Mir/Shuttle Docking Module for space environment exposure. OPM was retrieved during an EVA in January 1998 and was returned to Earth on board the Space Shuttle on mission STS-89.

Wilkes, D. R.↗

Drilling Down I/O Bottlenecks with Cross-layer I/O Profile Exploration

I/O performance monitoring tools such as Darshan and Recorder collect I/O-related metrics on production systems and help understand the applications' behavior. However, some gaps prevent end-users from seeing the whole picture when it comes to detecting and drilling down to the root causes of I/O performance slowdowns and where those problems originate. These gaps arise from limitations in the available metrics, their collection strategy, and the lack of translation to actionable items that could advise on optimizations. This paper highlights such gaps and proposes solutions to drill down to the source code level to pinpoint the root causes of I/O bottlenecks scientific applications face by relying on cross-layer analysis combining multiple performance metrics related to I/O software layers. We demonstrate with two real applications how metrics collected in high-level libraries (which are closer to the data models used by an application), enhanced by source-code insights and natural language translations, can help streamline the understanding of I/O behavior and provide guidance to end-users, developers, and supercomputing facilities on how to improve I/O performance. Using this cross-layer analysis and the heuristic recommendations, we attained up to 6.9× speedup from run-as-is executions.

Ather, Hammad↗

Stream discharge and water quality data for East Fork Poplar Creek beginning 2012

This data note describes 15-min discharge and in situ water quality data at two locations along East Fork Poplar Creek in east Tennessee, USA. Data records include temperature, gauge height, water surface elevation above mean sea level, and volumetric discharge. Water quality measurements include temperature, specific conductance, pH, dissolved oxygen (percent saturation and concentration), turbidity, and less extensive fDOM data at one site. The data records begin in 2012 at one site and 2015 at the second site; monitoring at both sites is ongoing (as of 2021). The goal of this data collection is to improve understanding of watershed functions, hydrologic dynamics, and material flux. The data will contribute to site conceptual and numerical models, exposure and risk evaluation, remediation selection and design, and performance monitoring. The data are publicly available and can be accessed via unique url or DOI.

54 ENVIRONMENTAL SCIENCES↗

INL Environmental Monitoring Plan (DOE/ID-11088 Rev. 5)

This plan provides a high-level summary of environmental monitoring performed by various organizations within and around the Idaho National Laboratory (INL) Site as required by U.S. Department of Energy (DOE) Order 435.1, Radioactive Waste Management, and DOE Order 458.1, Radiation Protection of the Public and the Environment, Guide DOE/EH-0173T, Environmental Regulatory Guide for Radiological Effluent Monitoring and Environmental Surveillance, and in accordance with 40 Code of Federal Regulations (CFR) 61, National Emission Standards for Hazardous Air Pollutants. The purpose of these orders is to 1) implement sound stewardship practices that protect the air, water, land, and other natural and cultural resources that may be impacted by DOE operations, and 2) to establish standards and requirements for the operations of DOE and DOE contractors with respect to protection of the environment and members of the public against undue risk from radiation. This plan describes the organizations responsible for conducting environmental monitoring across the INL Site, the rationale for monitoring, the types of media being monitored, where the monitoring is conducted, and where monitoring results can be obtained. Detailed monitoring procedures, program plans, or other governing documents used by contractors or agencies to implement requirements are referenced in this plan. This plan covers all planned monitoring and environmental surveillance. Non-routine activities such as special research studies and characterization of individual sites for environmental restoration are outside the scope of this plan.

54 ENVIRONMENTAL SCIENCES↗

Performance Understanding and Analysis for Exascale Data Management Workflows (Collaboration)

The general approach of the MONA project is depicted in Figure 1. The figure shows performance monitoring applied to an I/O workflow associated with a scientific simulation, with online measurements captured from this workflow informing methods for workflow reconfiguration and dynamic adjustment. The goal is to maintain suitable levels of Quality of Service for workflow execution, by understanding the underlying causes of workflow performance and behavior. One outcome will be workflow performance models able to characterize realistic workflows. Another outcome will be performance ‘mini-apps’ implementing such workflow behavior. Out of scope for this project are advanced methods for online workflow control.

97 MATHEMATICS AND COMPUTING↗

Vertical Characterization of Flow and Contaminant Concentration in New Hanford Extraction Wells

Effective groundwater remediation should focus on high-concentration, low-permeability zones within the aquifer, as these areas often present significant challenges to contaminant removal. Characterizing the vertical distribution of contamination in an aquifer is therefore critical for optimizing and monitoring pump-and-treat (P&T) systems to meet target cleanup timelines. Flow patterns driven by hydraulic gradients and variations in permeability are described to provide insight into contaminant mass removal from long-screened wells. The objective of this multi-phase work is to provide actionable recommendations for improving remedy performance monitoring and P&T operations, which ongoing evaluations will address. This report summarizes the preliminary results of vertical flow and contaminant distribution monitoring in new extraction wells at the Hanford Site.

54 ENVIRONMENTAL SCIENCES↗

The Exascale Framework for High Fidelity coupled Simulations (EFFIS): Enabling whole device modeling in fusion science

We present the Exascale Framework for High Fidelity coupled Simulations (EFFIS), a workflow and code coupling framework developed as part of the Whole Device Modeling Application (WDMApp) in the Exascale Computing Project. EFFIS consists of a library, command line utilities, and a collection of run-time daemons. Together, these software products enable users to easily compose and execute workflows that include: strong or weak coupling, in situ (or offline) analysis/visualization/monitoring, command-and-control actions, remote dashboard integration, and more. We describe WDMApp physics coupling cases and computer science requirements that motivate the design of the EFFIS framework. Furthermore, we explain the essential enabling technology that EFFIS leverages: ADIOS for performant data movement, PerfStubs/TAU for performance monitoring, and an advanced COUPLER for transforming coupling data from its native format to the representation needed by another application. Finally, we demonstrate EFFIS using coupled multi-simulation WDMApp workflows and exemplify how the framework supports the project’s needs. We show that EFFIS and its associated services for data movement, visualization, and performance collection does not introduce appreciable overhead to the WDMApp workflow and that the resource-dominant application’s idle time while waiting for data is minimal.

97 MATHEMATICS AND COMPUTING↗

Improved Line Outage Detection in Transmission Systems with Few PMUs

Unlike transmission systems, distribution systems historically lack enough measurements, making their real-time monitoring almost impossible. Recent deployment of diverse types of devices such as phasor measurement units (PMUs), smart meters, solar inverters and weather information sensors opens up new ways of monitoring these systems, with the assistance of customized machine learning (ML) applications. The paper describes a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams and creates synchronous measurement snapshots to be used by a hybrid robust state estimator (SE) which provides not only accurate state estimates but also real-time feedback for ML model refinement. Improved monitoring performance due to the use of developed computational framework is experimentally observed by simulated scenarios on an electric utility’s distribution system.