Charged Particle Tracking for the GlueX Detector

The GlueX experiment is a new experiment under construction at the Thomas Jefferson National Accelerator Facility designed to study gluonic degrees of freedom via the production of ``hybrid'' mesons with exotic quantum numbers. At full luminosity, the trigger rate is expected to be on the order of 150 kHz and the data rate to tape is expected to be on the order of 300 MB/s. In order to reduce the reconstruction time, the current GlueX analysis framework is multi-threaded such that multiple events can be analyzed in parallel on multi-core machines. The tracking code presents the largest bottleneck in the event reconstruction. By taking advantage of Single-Instruction, Multiple-Data (SIMD) instructions in the three-vector and matrix operations needed in the tracking code, the reconstruction can be sped up considerably. The current status of the tracking reconstruction for GlueX will be presented.

Taylor, Simon↗

The HEP.TrkX Project: deep neural networks for HL-LHC online and offline tracking

Particle track reconstruction in dense environments such as the detectors of the High Luminosity Large Hadron Collider (HL-LHC) is a challenging pattern recognition problem. Traditional tracking algorithms such as the combinatorial Kalman Filter have been used with great success in LHC experiments for years. However, these state-of-the-art techniques are inherently sequential and scale poorly with the expected increases in detector occupancy in the HL-LHC conditions. The HEP.TrkX project is a pilot project with the aim to identify and develop cross-experiment solutions based on machine learning algorithms for track reconstruction. Machine learning algorithms bring a lot of potential to this problem thanks to their capability to model complex non-linear data dependencies, to learn effective representations of high-dimensional data through training, and to parallelize easily on high-throughput architectures such as GPUs. This contribution will describe our initial explorations into this relatively unexplored idea space. Furthermore, we will discuss the use of recurrent (LSTM) and convolutional neural networks to find and fit tracks in toy detector data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The gravity extension for MCNP 6.2

Standard MCNP particle tracking takes place along straight-line trajectories from interaction point to interaction point. There is a feature within MCNP that is planned for deprecation that provides surface boundary conditions for approximating gravity for planetary cases, but this feature is not applicable to a cold neutron beam. A new extension has been developed to track particles along parabolic trajectories with a constant acceleration. MCNP contains 1st and 2nd-order surfaces as well as a special case of 4th-order surfaces for simple tori, and the intersection of parabolic trajectories with these surfaces becomes 2nd, 4th, and 8th-order equations in time, respectively. Solving these equations utilizes a fast algorithm for finding the roots of polynomials. Finally, the theory, MCNP input card, and examples of using this new feature will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle-Displacement Tracking In Particle-Image Velocimetry

Particle images processed rapidly and automatically into velocity-vector maps. This technique requires no processing of photographic plates, no tedious visual recognition and manual designation of large numbers of image features for subsequent processing, little or no interruption by technician and is order of magnitude faster than any of prior techniques.

Wernet, Mark P.↗

Leveraging Topological Events in Tracking Graphs for Understanding Particle Diffusion

Abstract Single particle tracking (SPT) of fluorescent molecules provides significant insights into the diffusion and relative motion of tagged proteins and other structures of interest in biology. However, despite the latest advances in high‐resolution microscopy, individual particles are typically not distinguished from clusters of particles. This lack of resolution obscures potential evidence for how merging and splitting of particles affect their diffusion and any implications on the biological environment. The particle tracks are typically decomposed into individual segments at observed merge and split events, and analysis is performed without knowing the true count of particles in the resulting segments. Here, we address the challenges in analyzing particle tracks in the context of cancer biology. In particular, we study the tracks of KRAS protein, which is implicated in nearly 20% of all human cancers, and whose clustering and aggregation have been linked to the signaling pathway leading to uncontrolled cell growth. We present a new analysis approach for particle tracks by representing them as tracking graphs and using topological events – merging and splitting, to disambiguate the tracks. Using this analysis, we infer a lower bound on the count of particles as they cluster and create conditional distributions of diffusion speeds before and after merge and split events. Using thousands of time‐steps of simulated and in‐vitro SPT data, we demonstrate the efficacy of our method, as it offers the biologists a new, detailed look into the relationship between KRAS clustering and diffusion speeds.

McDonald, T.↗

A Method to Represent a Well in a Three‐Dimensional Discrete Fracture Network Model

Abstract In discrete fracture network (DFN) modeling, fractures are randomly generated and placed in the model domain. The rock matrix is considered impermeable. Small fractures and isolated fractures are often ignored to reduce computational expense. As a result, the rock matrix between fractures could be large and intersections may not be found between a well introduced in the model and the hydraulically connected fracture networks (fracture backbones). To overcome this issue, this study developed a method to conceptualize a well in a three‐dimensional (3D) DFN using two orthogonal rectangular fractures oriented along the well's axis. Six parameters were introduced to parameterize the well screen and skin zone, and to control the connectivity between the well and the fracture backbones. The two orthogonal fractures were discretized using a high‐resolution mesh to improve the quality of flow and transport simulations around and along the well. The method was successfully implemented within dfnWorks 2.0 (Hyman et al. 2015) to incorporate a well in a 3D DFN and to track particles leaving an injection well and migrating to a pumping well. Verification of the method against MODFLOW/MODPATH found a perfect match in simulated hydraulic head and particle tracking. Using three examples, the study showed that the method ensured the connectivity between wells and fracture backbones, and honored the physical processes of flow and transport along and around wells in DFNs. Recommendations are given for estimating the values of the six introduced well parameters in a real‐world case study.

Pham, Hai (ORCID:0000000310164394)↗

SU-E-T-141: Effect of a Single Gold Nanoparticle with Different Sizes Inside a Small Water Phantom

Purpose: This study is to investigate the effects of the gold nanoparticles (GNP), a series of micrometre scale simulations have been constructed with Geant4 to track particles and simulate the effects of those particles as they pass through water phantom. Methods: The simulations were used to calculate the number of secondary electrons which are emitted from the particle tracks and the amount of energy which is deposited in the cell tissue. More electrons means that more water molecules can undergo hydrolysis and create potentially dangerous free radical molecules, therefore breaking up DNA and killing off cells or causing damaging mutations. Results: For the 20nm GNP, all three proton energies saw a small increase of electrons above the control, while the X-rays nearly tripled the number of electrons in the phantom. For the 50 nm GNP, the 3 and 2 MeV protons saw a small increase again, however the 1 MeV protons saw a decrease in electrons, the X-rays saw a large increase of nearly 4 times the number of electrons. For the 110nm GNP, all three proton energies saw a decrease in the total number of electrons in the phantom, while the X-rays saw an increase of 8 times as many electrons. Conclusion: From the range of GNP sizes used, it was found that the X-rays have a larger dose enhancement effect as the GNP size increases, the relation between electron emissions and GNP size was linear. This is because the majority of the dose from the X-rays is delivered to the cell tissue through the initial high energy secondary electrons, any dose lost from the Augerelectrons being trapped inside the GNP volume is small compared to the dose that escapes with the high energy electrons.

60 APPLIED LIFE SCIENCES↗

Laser calibration system at ProtoDUNE-HD

The Deep Underground Neutrino Experiment (DUNE) is a full experiment consisting of multiple detectors separated by a near and far site. DUNE will study long-baseline neutrino oscillations, which will provide insight into CP-violation, neutrino mass ordering, and the matter/antimatter asymmetry. Additionally, DUNE will search for nucleon decay and observe neutrinos from supernovae. DUNE relies on liquid argon time projection chambers (LAr TPCs), an excellent technology for tracking particles and reconstructing their interactions with high precision. To achieve its goals, DUNE is supported by the ProtoDUNE experiments at CERN, which serve as large-scale prototypes to validate detector technologies and calibration systems. The precise calibration of the electric field within the detector is vital for accurate 3D reconstruction of particle tracks, particularly in maintaining the consistency of charge measurements along the drift path. This work presents the development and implementation of a laser calibration system designed for ProtoDUNE-II. This poster involved the physical installation and commissioning of the laser system. The commissioning process included extensive testing to ensure alignment and operational efficiency, such as rotating the laser to observe behavior of tracks. The groundwork established during these steps is crucial for future data analysis, aiming to measure the electron lifetime (in the active volume) and map the electric field inside the detector with high precision.

Campanelli, Wallison [LIP]↗

A Kuiper Belt Source for Solar Flare Track-Rich Interplanetary Dust Particles

The presence of solar flare particle tracks in mineral grains within interplanetary dust particles (IDPs) has long been accepted as proof of their extraterrestrial origin [e.g. 1]. The 10-20 micrometers diameter IDPs released by dust producing objects in the solar system (mainly comets and asteroids) spiral in towards the Sun under the influence of Poynting-Robertson (PR) drag forces [2] and accumulate solar flare energetic particle tracks during their journey. The number of IDPs with well-constrained track density measurements is small, owing to the difficulty in the measurements and the lack of appropriatelysized crystals in which to image them. In order to use track densities as a chronometer of space exposure, the track production rate must be known. All previous work relied on track production rates determined by chemical etching techniques [e.g. 3], but tracks in IDPs are measured using TEM imaging. Here we report measurements of track densities in IDPs from both the anhydrous and hydrated IDP groups. Using the track production calibration determined from TEM observations of anorthite and olivine in lunar rock 64455 [4] we estimate space exposure times for these IDPs to constrain their parent body sources.

Keller, L. P.↗

Tracking single particle rotation: Probing dynamics in four dimensions

Direct visualization and tracking of small particles at high spatial and temporal resolution provides a powerful approach to probing complex dynamics and interactions in chemical and biological processes. Analysis of the rotational dynamics of particles adds a new dimension of information that is otherwise impossible to obtain with conventional 3-D particle tracking. In this review, we survey recent advances in single-particle rotational tracking, with highlights on the rotational tracking of optically anisotropic Janus particles. Furthermore, strengths and weaknesses of the various particle tracking methods, and their applications are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma electron hole kinematics. II. Hole tracking Particle-In-Cell simulation

The kinematics of a 1-D electron hole is studied using a novel Particle-In-Cell simulation code. A hole tracking technique enables us to follow the trajectory of a fast-moving solitary hole and study quantitatively hole acceleration and coupling to ions. We observe a transient at the initial stage of hole formation when the hole accelerates to several times the cold-ion sound speed. Artificially imposing slow ion speed changes on a fully formed hole causes its velocity to change even when the ion stream speed in the hole frame greatly exceeds the ion thermal speed, so there are no reflected ions. The behavior that we observe in numerical simulations agrees very well with our analytic theory of hole momentum conservation and the effects of “jetting.”.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positron emission tracking of individual particles in particle-laden rimming flow

The motion of a single tracer particle in particle-laden rimming flows is investigated experimentally by means of Positron Emission Particle Tracking (PEPT). Semi-dilute suspensions, with a volume fraction of 8% of heavy particles are considered. The trajectory of the tracer particle is monitored for several thousand cylinder revolutions and related to the optically recorded drift of the large-scale granular segregation bands developing in the cylinder. Results of the data analysis provide first insights into the relation between behaviour of individual particles and the spatiotemporal dynamics displayed by the macroscopic particle-segregation patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Particle displacement tracking for PIV

A new Particle Imaging Velocimetry (PIV) data acquisition and analysis system, which is an order of magnitude faster than any previously proposed system has been constructed and tested. The new Particle Displacement Tracing (PDT) system is an all electronic technique employing a video camera and a large memory buffer frame-grabber board. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine velocity vectors. Application of the PDT technique to a counter-rotating vortex flow produced over 1100 velocity vectors in 110 seconds when processed on an 80386 PC.

Wernet, Mark P.↗

On bias of kinetic temperature measurements in complex plasmas

The kinetic temperature in complex plasmas is often measured using particle tracking velocimetry. Here, we introduce a criterion which minimizes the probability of faulty tracking of particles with normally distributed random displacements in consecutive frames. Faulty particle tracking results in a measurement bias of the deduced velocity distribution function and hence the deduced kinetic temperature. For particles with a normal velocity distribution function, mistracking biases the obtained velocity distribution function towards small velocities at the expense of large velocities, i.e., the inferred velocity distribution is more peaked and its tail is less pronounced. The kinetic temperature is therefore systematically underestimated in measurements. We give a prescription to mitigate this type of error.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Software manual for operating particle displacement tracking data acquisition and reduction system

The software manual is presented. The necessary steps required to record, analyze, and reduce Particle Image Velocimetry (PIV) data using the Particle Displacement Tracking (PDT) technique are described. The new PDT system is an all electronic technique employing a CCD video camera and a large memory buffer frame-grabber board to record low velocity (less than or equal to 20 cm/s) flows. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine 2-D velocity vectors. All the PDT data acquisition, analysis, and data reduction software is written to run on an 80386 PC.

Wernet, Mark P.↗