Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlated characterization of 20 Ne-implanted targets using nuclear reaction analysis, Rutherford backscattering spectrometry, and ion transport modeling

In this article, we present the preparation and characterization of a large sample of implanted noble gas targets for use in precision nuclear astrophysics measurements with intense proton beams. Tantalum and titanium backings were prepared using wet-acid etching, outgassed via resistive heating, and implanted with 20 Ne + beams from differing ion sources. These experimental targets were investigated using both nuclear reaction analysis techniques on the 1169-keV resonance in 20 Ne(p, $\gamma$) 21 Na and Rutherford backscattering spectrometry analysis with 2-MeV α-particle beams. Results from these analyses reveal small target-to-target variations in stoichiometry, while exhibiting excellent agreement independent of ion-beam analysis method. We also present a self-consistent validation of the nuclear reaction analysis results using ion transport simulations in TRIM-2013 that rely on input parameters from SIMNRA scattering-yield fits to Rutherford backscattering spectra. In addition to a complete description of the implantation profile, this analysis method provides an alternate solution for characterizing a large sample of implanted targets when no suitable resonances are available for nuclear reaction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SoW: Energy-Dependent Fission Product Yields

The purpose of this LLNL subcontract is to capitalize on our already established long-term relationship with Duke University and Triangle Universities Nuclear Laboratory (TUNL) to study fission observables like Fission Product Yields (FPY), fission cross-section and other data relevant to our programmatic needs. LLNL with Duke university partnership, wants to further develop new experimental capabilities to measure critical nuclear data important for LLNL stakeholders. The new FPY data will provide important benchmarks for nuclear theory and evaluation currently developed by the nuclear data and theory group. The improved FPY data is of interest to many major laboratory programs, including nuclear chemistry, nuclear forensics, safeguard, and nonproliferation communities. The impact of new FPY data, obtained by a graduate student from Duke (Aitor Bracho), will result in the U.S. Nuclear Data Program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnetostrictive Ultrasonic Waveguide Transducer for In-Pile Thermometry

Real-time and reliable temperature measurement on nuclear fuels is crucial for the safe operation of existing pressurized-water reactors and future advanced nuclear reactors. Magnetostrictive materials deform when subjected to a magnetic field or exhibit magnetization variation when stressed. Here, based on these properties, this study prototyped an ultrasonic thermometer (UT) consisting of a magnetostrictive waveguide, a dc coil providing appropriate magnetic biasing, and an ac coil generating an acoustic impulse and detecting the resulting acoustic echoes. By tracking the time of flight between the excitation pulse and the echoes, the UT can potentially detect nuclear fuel cladding temperature from a long distance. In this study, magnetostrictive iron–gallium alloys, or Galfenol, were selected as the waveguide due to their large magnetostriction, superior temperature survivability, excellent radiation resilience, and high mechanical robustness. A multiphysics finite-element model considering electrical, magnetic, and mechanical dynamics in the magnetostrictive UT was then developed. The model exhibited an error of 0.24% in time-of-flight simulation and, therefore, enabled computer-aided design and guided signal processing. Between room temperature and 120 °C, the new Galfenol-based UT exhibits a linear sensitivity of 162.8×10 ₋6 °C ₋1 , which is 51.7% higher than a previous magnetostrictive UT based on iron–cobalt–vanadium alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MUSIC Critical Benchmark and Nuclear Data

The Measurement of Uranium Subcritical and Critical (MUSIC) experiment was a series of measurements of critical and subcritical configurations of bare highly enriched uranium. The goal was to compare measurement methods, analysis techniques, and simulation methods across regimes of criticality and to provide high-quality validation of 235 U nuclear data. A benchmark evaluation of the two critical configurations of the MUSIC experiments will soon be published in the release of the International Criticality Safety Benchmark Evaluation Project Handbook. The recent execution of the experiment aids in proper quantification of model simplifications and all uncertainties associated with the experiment. Historical benchmark evaluations are heavily relied on for uranium nuclear data validation despite the fact that the same level of documentation and comparable uncertainty analysis may not be present. The MUSIC evaluation is less likely to include “unknown unknowns” that could impede accurately modeling the system. Presented are both highly detailed and very simplified models, which represent the experimental configurations accurately, aiding the users of the benchmark for nuclear data or transport code validation. The sensitivities of k eff to nuclear data and nuclear data–related uncertainties are very similar between this experiment and previous bare uranium sphere experiments. In addition, the nuclear data uncertainties to any nuclides other than 235 U are small. For all these reasons, the recently evaluated MUSIC benchmark critical configurations could prove very useful for 235 U nuclear data validation. Currently, major libraries have good agreement with the experimental results, within 200 pcm for all nuclear data libraries, and within one standard deviation of the experimental result for most. Suggested nuclear data adjustments based on MUSIC and Lady Godiva are also presented, with posterior improvements to both the agreement in k eff and the uncertainty associated with the nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

International Radiological/Nuclear Training for Emergency Response - Major Public Events Virtual Workshop: Nuclear Security Planning and Operations (Day 3) [Slides]

This module will provide a basic overview of radiological/nuclear search operations, including the application of radiological detection instrumentation and best practices for operational tactics, techniques and procedures. This module will introduce basic radiological/nuclear search operations and include the following: (1) A review of the principles of optimizing detection, (2) An understanding of radiation hazards and alarms, and (3) An examination of nuclear security measures best practices for buildings and stadium complexes, large areas, roadways and parking areas, and pedestrian and vehicle entrance portals.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental Investigation of Subcritical Neutron and Gamma Noise Methods at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by the Lawrence Livermore National Laboratory (LLNL), with key participants from the Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and the Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements was planned and executed. The primary aim of this article was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work, we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods. Our results agree well with independent experimental measurements and simulations performed by LLNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Safeguards Technical Objectives for Thorium Molten Salt Reactor Fuel Cycles

China, Denmark, France, India, Indonesia, the United Kingdom, and the United States, among others, are exploring commercial thorium fuel cycles for domestic power production and/or international export. For any thorium fuel cycle facilities built and/or operated in a non-nuclear weapon State with a comprehensive safeguards agreement, those facilities and any associated nuclear material would be subject to international nuclear safeguards by the International Atomic Energy Agency (IAEA). Thorium fuel cycle facilities offered for the application of safeguards under a voluntary offer agreement by a nuclear weapon State would also be subject to safeguards, if selected by the IAEA. Compared to uranium/plutonium fuel cycle facilities, thorium fuel cycle facilities are comparatively diverse from an inspection and accounting perspective, differing greatly in material type, form, and design from uranium/plutonium fuel cycle facilities and also from each other. Of these, the most complex thorium fuel cycles – and therefore likely the most challenging to the implementation of international nuclear safeguards – are those that include thorium molten salt reactors. With thorium fuel cycles approaching near-term commercial deployment timelines, it is imperative that the international nuclear safeguards community begins to think about how to adapt existing international nuclear safeguards concepts and approaches to thorium fuel cycles, as well as mitigate any gaps that may exist. This paper focuses on the development of recommended safeguards technical objectives for efficient and effective application of international nuclear safeguards measures (e.g., containment / surveillance, non-destructive assay, destructive assay, environmental sampling) to thorium molten salt reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Subcritical Neutron and Gamma Noise Measurements at the Seven Percent Critical Experiment (7uPCX)

As part of a collaborative international effort organized by Lawrence Livermore National Laboratory (LLNL), with key participants from L’Institut de radioprotection et de sûreté nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Sandia National Laboratories (SNL), a series of high-multiplication subcritical neutron and gamma noise measurements were planned and executed. The primary aim of this research was to advance detector technology, assess the validity of gamma noise for subcriticality measurements, and nuclear criticality safety, focusing on collecting list-mode or time-series data from various reactor configurations with multiplication values ranging from 20 to 310. This comprehensive dataset enabled a detailed comparative analysis of multiple detector systems and the results of both neutron and gamma noise measurements. In this work we focus on experimentally comparing the results from neutron and gamma noise measurements. We note good agreement between estimations of the prompt neutron decay constant and demonstrate the effects of changing reactor geometry on the efficiency of the differing methods.

Criticality↗

On the constancy of solar particle fluxes from track, thermoluminescence and solar wind measurements in lunar rocks

Evidence contained within lunar rocks concerning possible variations in solar activity over the last 1 to 2 million years is reviewed. The effects of solar wind particles, which are implanted at shallow depths, solar flare protons, which produce thermoluminescence as well as stable and radionuclides, and solar flare heavy nuclei, which produce tracks, are considered, and the quality and limitations of nuclear tracks measurements as indicators of solar flare flux histories are discussed. Methods used for the determination of the solar flare track production rate, which must be known in order to measure lunar rock surface exposure times, are compared, and it is concluded that most of the evidence favors the rate obtained by Blanford et al. (1975). Information on the constancy of the solar flare particle flux obtained by comparison of the effects of different surface phenomena with solar particle effects is then illustrated for the cases of comparisons between solar flare tracks and microcrater densities, solar flare particle fluxes measured over different periods, and comparisons of the solar flare track production rate with the solar wind flux and microcratering rate. It is noted that these studies provide no evidence for a change in solar particle flux by more than a factor of two over the last 10,000 to 1 million years, or for a change in the solar flare Fe/H ratio in the last 2 million years.

Zinner, E.↗

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Scattering Calorimeter FY24 Deliverable Report

A simulation-based method has been developed to prototype new detector designs for nuclear data measurements utilizing neutron scattering. This method uses representative physics inputs for signal and background generation, full detector resolution smearing benchmarked by experimental data, and a neutron beam timing simulation to produce analyzable output like a physical measurement. A test case has been studied using a hybrid time-of-flight calorimeter detector for scattering cross-section measurements on 239 Pu with 1-5 MeV incident monoenergetic neutrons. Data analysis methods have been developed to perform event-level particle reconstruction and reaction channel discrimination. This analysis has been used to estimate the capability of the test detector to perform simultaneous scattering and fission cross section measurements, as well as its ability to provide neutron spectra and particle angular information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.

Porter, Frederick S.↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Measurements of Irradiated Low Enriched Fuel with a Gamma-Ray Scanning System (ANIMMA 2023 Conference Presentation)

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This article documents the modeling, benchmarking measurements, and the calculated number of fissions per gram in the SERTTA-A rodlet which was previously irradiated at TREAT.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear X-Ray Activity in Low-surface-brightness Galaxies: Prospects for Constraining the Local Black Hole Occupation Fraction with a Chandra Successor Mission

About half of nearby galaxies have a central surface brightness>1 mag below that of the sky. The overall properties of these low-surface-brightness galaxies(LSBGs)remain understudied, and in particular we know very little about their massive black hole population. This gap must be closed to determine the frequency of massive black holes at z=0 as well as to understand their role in regulating galaxy evolution. Here we investigate the incidence and intensity of nuclear, accretion-powered X-ray emission in a sample of 32 nearby LSBGs with the Chandra X-ray Observatory. A nuclear X-ray source is detected in four galaxies(12.5%). Based on an X-ray binary contamination assessment technique developed for normal galaxies, we conclude that the detected X-ray nuclei indicate low-level accretion from massive black holes. The active fraction is consistent with that expected from the stellar mass distribution of the LSBGs, but not their total baryonic mass, when using a scaling relation from an unbiased X-ray survey of normal galaxies. This suggests that their black holes co-evolved with their stellar population. In addition, the apparent agreement nearly doubles the number of galaxies available within∼100 Mpc for which a measurement of nuclear activity can efficiently constrain the frequency of black holes as a function of stellar mass. We conclude by discussing the feasibility of measuring this occupation fraction to a few percent precision below ≲ 10^10 M(ʘ) with high-resolution, wide-field X-ray missions currently under consideration.

Edmund J. Hodges-Kluck↗

Plasma stopping-power measurements reveal transition from non-degenerate to degenerate plasmas

Physically realized electron gas systems usually reside in either the quantum non-degenerate or fully degenerate limit, where the average de Broglie wavelength of the thermal electrons becomes comparable with the interparticle distance between electrons. A few systems, such as young brown dwarfs and the cold dense fuels created in imploded cryogenic capsules at the National Ignition Facility, lie between these two limits and are partially degenerate. The National Ignition Facility has the unique capability of varying the electron quantum degeneracy by adjusting the laser drive used to implode the capsules. This allows experimental studies of the effects of the degeneracy level on plasma transport properties. By measuring rare nuclear reactions in these cold dense fuels, we show that the electron stopping power, which is the rate of energy loss per unit distance travelled by a charged particle, changes with increasing electron density. We observe a quantum-induced shift in the peak of the stopping power using diagnostics that measure above and below this peak. The observed changes in the stopping power are shown to be unique to the transition region between non-degenerate and degenerate plasmas. Furthermore, our results support the screening models applied to partially degenerate astrophysical systems such as young brown dwarfs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Varying Quantum Degeneracy in Plasmas Created at the National Ignition Facility [Slides]

Physically realized electron gas systems usually reside in either the quantum non-degenerate or fully degenerate limit, where the average de Broglie wavelength of the thermal electrons becomes comparable with the interparticle distance between electrons. A few systems, such as young brown dwarfs and the cold dense fuels created in imploded cryogenic capsules at the National Ignition Facility, lie between these two limits and are partially degenerate. The National Ignition Facility has the unique capability of varying the electron quantum degeneracy by adjusting the laser drive used to implode the capsules. This allows experimental studies of the effects of the degeneracy level on plasma transport properties. By measuring rare nuclear reactions in these cold dense fuels, we show that the electron stopping power, which is the rate of energy loss per unit distance travelled by a charged particle, changes with increasing electron density. We observe a quantum-induced shift in the peak of the stopping power using diagnostics that measure above and below this peak. The observed changes in the stopping power are shown to be unique to the transition region between non-degenerate and degenerate plasmas. Our results support the screening models applied to partially degenerate astrophysical systems such as young brown dwarfs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗