Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modal identification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Application of physical parameter identification to finite element models

A time domain technique for matching response predictions of a structural dynamic model to test measurements is developed. Significance is attached to prior estimates of physical model parameters and to experimental data. The Bayesian estimation procedure allows confidence levels in predicted physical and modal parameters to be obtained. Structural optimization procedures are employed to minimize an error functional with physical model parameters describing the finite element model as design variables. The number of complete FEM analyses are reduced using approximation concepts, including the recently developed convoluted Taylor series approach. The error function is represented in closed form by converting free decay test data to a time series model using Prony' method. The technique is demonstrated on simulated response of a simple truss structure.

Bronowicki, Allen J.↗

Vibration control experiment design for the 15-m hoop/column antenna

A test program is designed for a ground-based vibration control experiment utilizing as the test article the 15-M Hoop/Column Antenna. Overall objectives of the designed ground-based test program include: (1) the validation of large space structure (LSS) control systemm techniques; (2) the validation of LSS parameter identification techniques: (3) the evaluation of actuator of actuator and sensor placement methodology; and (3) the validation of LSS computer models. Critical concerns in LSS Controls and Dynamics are: low frequency vibrational modes, close modal spacing, parameter uncertainties, controller software limitations, nonlinearities and coupling of modes through damping. Analytical results are presented which include compensator designs for varying compensator order.

Ham, F. M.↗

Aeroservoelastic Uncertainty Model Identification from Flight Data

Uncertainty modeling is a critical element in the estimation of robust stability margins for stability boundary prediction and robust flight control system development. There has been a serious deficiency to date in aeroservoelastic data analysis with attention to uncertainty modeling. Uncertainty can be estimated from flight data using both parametric and nonparametric identification techniques. The model validation problem addressed in this paper is to identify aeroservoelastic models with associated uncertainty structures from a limited amount of controlled excitation inputs over an extensive flight envelope. The challenge to this problem is to update analytical models from flight data estimates while also deriving non-conservative uncertainty descriptions consistent with the flight data. Multisine control surface command inputs and control system feedbacks are used as signals in a wavelet-based modal parameter estimation procedure for model updates. Transfer function estimates are incorporated in a robust minimax estimation scheme to get input-output parameters and error bounds consistent with the data and model structure. Uncertainty estimates derived from the data in this manner provide an appropriate and relevant representation for model development and robust stability analysis. This model-plus-uncertainty identification procedure is applied to aeroservoelastic flight data from the NASA Dryden Flight Research Center F-18 Systems Research Aircraft.

Brenner, Martin J.↗

Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

Sargsyan, Ashot E.↗

Integrating N -glycan and CODEX imaging reveal cell-specific protein glycosylation in healthy human lung

Identifying cell-specific glycan structures in human lungs is critical for understanding the chemistry and mechanisms that guide cell–cell and cell–matrix interactions and determining nuanced functions of specific glycosylation. Our dual-modality omics platform, which uses matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) to profile glycan chemistry at 50 μm × 50 μm scale, combined with co-detection by indexing (CODEX) to provide cell identification from the exact same tissue section, is a significant step in this direction. It enabled us to detect, differentiate, and reveal chemical properties of N-glycans in the various cell types of a human lung, suggesting the cell-specific function of distinct carbohydrate moieties. This innovative technological combination bridges the gap between the specific protein glycosylation and their cellular origin, paving the way for targeted studies in the lungs and many other human tissues where glycans mediate cell–cell recognition events.

Veličković, Dušan [Pacific Northwest National Labo↗

Dynamics of the McDonnell-Douglas Large Scale Dynamic Rig and dynamic calibration of the rotor balance

A shake test was performed on the Large Scale Dynamic Rig in the 40- by 80-Foot Wind Tunnel in support of the McDonnell Douglas Advanced Rotor Technology (MDART) Test Program. The shake test identifies the hub modes and the dynamic calibration matrix of the rotor balance. For hub mode identification, three configurations were tested: wind tunnel scale unlocked with dampers engaged and disengaged, and wind tunnel scale locked. Test data were analyzed with a multi-degree-of-freedom time domain algorithm to identify the modal properties of the hub modes. The damping of the low frequency hub modes (ground resonance modes) increases significantly with the wind tunnel dampers engaged. For dynamic calibration of the rotor balance, the shake test was performed only with the wind tunnel dampers engaged. The dynamic calibration matrix, computed from the shake test data using a least squares error method, is used to correct the five-per-rev vibratory balance readings. The corrections are large for the side force, moderate for the axial force and inplane hub moments, and small for the normal force.

Nguyen, Khanh↗

Second Harmonic Imaging improves Echocardiograph Quality on board the International Space Station

Ultrasound (US) capabilities have been part of the Human Research Facility (HRF) on board the International Space Station (ISS) since 2001. The US equipment on board the ISS includes a first-generation Tissue Harmonic Imaging (THI) option. Harmonic imaging (HI) is the second harmonic response of the tissue to the ultrasound beam and produces robust tissue detail and signal. Since this is a first-generation THI, there are inherent limitations in tissue penetration. As a breakthrough technology, HI extensively advanced the field of ultrasound. In cardiac applications, it drastically improves endocardial border detection and has become a common imaging modality. U.S. images were captured and stored as JPEG stills from the ISS video downlink. US images with and without harmonic imaging option were randomized and provided to volunteers without medical education or US skills for identification of endocardial border. The results were processed and analyzed using applicable statistical calculations. The measurements in US images using HI improved measurement consistency and reproducibility among observers when compared to fundamental imaging. HI has been embraced by the imaging community at large as it improves the quality and data validity of US studies, especially in difficult-to-image cases. Even with the limitations of the first generation THI, HI improved the quality and measurability of many of the downlinked images from the ISS and should be an option utilized with cardiac imaging on board the ISS in all future space missions.

Garcia, Kathleen↗

Methods for rapid identification of anomalous layers in laser powder bed fusion

In situ process monitoring is a key requirement for increased industry acceptance of powder bed Additive Manufacturing. As sensing technologies increase in maturity, attention must also be given to effective data exploration techniques. These data are often high-resolution and multi-modal, with each build consisting of thousands of layers. Here, in this paper, the authors propose two methods enabling users to rapidly identify layers of interest within a build. Both methods leverage results from deep learning based segmentations of in situ powder bed images. The first method is an unsupervised “reverse layer search” algorithm while the second method uses supervised machine learning.

36 MATERIALS SCIENCE↗

Single point random modal test technology application to failure detection

Frequency response function data, normally acquired as a data base for use in development of empirically based mode shapes, has additional utility. Comparison and analysis of frequency response function data sets obtained prior to and after environmental tests of an Orbiter body flap have enabled identification of structural damage that was not detected by conventional visual, X-ray, and ultrasonic inspections. The analyses and conclusions reported demonstrate that specific damaged areas within a relatively complex structure identified on a timely basis.

West, W. M., Jr.↗

The application of TSIM software to act design and analysis on flexible aircraft

The TSIM software is described. This is a package which uses an interactive FORTRAN-like simulation language for the simulation on nonlinear dynamic systems and offers facilities which include: mixed continuous and discrete time systems, time response calculations, numerical optimization, automatic trimming of nonlinear aircraft systems, and linearization of nonlinear equations for eigenvalues, frequency responses and power spectral response evaluation. Details are given of the application of TSIM to the analysis of aeroelastic systems under the RAE Farborough extension FLEX-SIM. The aerodynamic and structural data for the equations of motion of a flexible aircraft are prepared by a preprocessor program for incorporation in TSIM simulations. Within the simulation, the flexible aircraft model may then be selected interactively for different flight conditions and modal reduction techniques applied. The use of FLEX-SIM is demonstrated by an example of the flutter prediction for a simple aeroelastic model. By utilizing the numerical optimization facility of TSIM, it is possible to undertake identification of required parameters in the TSIM model within the simulation.

Kaynes, Ian W.↗

Multimodality instrument for tissue characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration. The use of this system will make surgical procedures safer, more accurate, and more efficient. Other applications of this system include the detection, prognosis and treatment of breast cancer, prostate cancer, spinal diseases, and use in general exploratory surgery.

Mah, Robert W.↗

Multimodality Instrument for Tissue Characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip is discussed. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network, program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration.

Mah, Robert W.↗

Experimental results of active control on a large structure to suppress vibration

Three design methods, Linear Quadratic Gaussian with Loop Transfer Recovery (LQG/LTR), H-infinity, and mu-synthesis, are used to obtain compensators for suppressing the vibrations of a 10-bay vertical truss structure, a component typical of what may be used to build a large space structure. For the design process the plant dynamic characteristics of the structure were determined experimentally using an identification method. The resulting compensators were implemented on a digital computer and tested for their ability to suppress the first bending mode response of the 10-bay vertical truss. Time histories of the measured motion are presented, and modal damping obtained during the experiments are compared with analytical predictions. The advantages and disadvantages of using the various design methods are discussed.

Dunn, H. J.↗

Identification and characterization of structural nonlinearities in the Space Shuttle Main Engine

Structural nonlinearities should be considered in the analysis and modeling of mechanical systems for accuracy in predicting dynamic behavior. Moreover, checks for nonlinearity should address the type and class of nonlinearity in the structure and identify the probable cause. A series of experimental modal survey tests were carried out to determine and characterize the structural nonlinearities of the Space Shuttle Main Engine main injector. Different excitation regimes at various amplitudes were utilized to induce vibration and strain, and acceleration measurements were taken at judiciously selected locations. The test results indicated that both stiffness and damping nonlinearities were present.

Panossian, H. V.↗

Mode Projection Method for Target Mode Identification

A method for projecting flight configuration eigenvectors onto the vector space of the test configuration eigenvectors is proposed. The underlying concept of the proposed method is that any flight configuration eigenvectors (that can be replicated by a linear combination of test configuration eigenvectors) is correlated if the constituent test eigenvectors are themselves correlated. Therefore, the modal test target mode shapes should be those test modes that combine to form the important modes of the flight configurations. This approach also recognizes that it is the deformed shapes that dictate what sections of the structure are “highly strained” (in a relative sense, within each mode shape), and that these “highly strained” sections require an accurate stiffness representation to achieve an accurate model correlation.

Jeffrey A Peck↗

Identifying approximate linear models for simple nonlinear systems

This paper addresses the identification (realization) of approximate linear models from response data for certain nonlinear dynamic systems. Response characteristics for several typical nonlinear joints are analyzed mathematically and represented by series expansions. The parameters of the series expansion are then compared with the modal parameters of a linear model identified by the Eigensystem Realization Algorithm. The agreement of the identified model and the analytically derived representation is excellent for the cases studied. Also laboratory data from a model which exhibited stiffening behavior was analyzed using the Eigensystem Realization algorithm and Fast Fourier Transform. The laboratory experiment demonstrated the ability of the technique to recover the model characteristics using real data.

Horta, L. G.↗

Hyperspectral Fluorescence and Reflectance Imaging Instrument

The system is a single hyperspectral imaging instrument that has the unique capability to acquire both fluorescence and reflectance high-spatial-resolution data that is inherently spatially and spectrally registered. Potential uses of this instrument include plant stress monitoring, counterfeit document detection, biomedical imaging, forensic imaging, and general materials identification. Until now, reflectance and fluorescence spectral imaging have been performed by separate instruments. Neither a reflectance spectral image nor a fluorescence spectral image alone yields as much information about a target surface as does a combination of the two modalities. Before this system was developed, to benefit from this combination, analysts needed to perform time-consuming post-processing efforts to co-register the reflective and fluorescence information. With this instrument, the inherent spatial and spectral registration of the reflectance and fluorescence images minimizes the need for this post-processing step. The main challenge for this technology is to detect the fluorescence signal in the presence of a much stronger reflectance signal. To meet this challenge, the instrument modulates artificial light sources from ultraviolet through the visible to the near-infrared part of the spectrum; in this way, both the reflective and fluorescence signals can be measured through differencing processes to optimize fluorescence and reflectance spectra as needed. The main functional components of the instrument are a hyperspectral imager, an illumination system, and an image-plane scanner. The hyperspectral imager is a one-dimensional (line) imaging spectrometer that includes a spectrally dispersive element and a two-dimensional focal plane detector array. The spectral range of the current imaging spectrometer is between 400 to 1,000 nm, and the wavelength resolution is approximately 3 nm. The illumination system consists of narrowband blue, ultraviolet, and other discrete wavelength light-emitting-diode (LED) sources and white-light LED sources designed to produce consistently spatially stable light. White LEDs provide illumination for the measurement of reflectance spectra, while narrowband blue and UV LEDs are used to excite fluorescence. Each spectral type of LED can be turned on or off depending on the specific remote-sensing process being performed. Uniformity of illumination is achieved by using an array of LEDs and/or an integrating sphere or other diffusing surface. The image plane scanner uses a fore optic with a field of view large enough to provide an entire scan line on the image plane. It builds up a two-dimensional image in pushbroom fashion as the target is scanned across the image plane either by moving the object or moving the fore optic. For fluorescence detection, spectral filtering of a narrowband light illumination source is sometimes necessary to minimize the interference of the source spectrum wings with the fluorescence signal. Spectral filtering is achieved with optical interference filters and absorption glasses. This dual spectral imaging capability will enable the optimization of reflective, fluorescence, and fused datasets as well as a cost-effective design for multispectral imaging solutions. This system has been used in plant stress detection studies and in currency analysis.

Ryan, Robert E.↗

Identification of XV-15 aeroelastic modes using frequency sweeps

The XV-15 tilt-rotor wing has six major aeroelastic modes that are close in frequency. To precisely excite individual modes during flight test, dual flaperon exciters with automatic frequency-sweep controls were installed. The resulting structural data were analyzed in the frequency domain (Fourier-transformed). Modal frequencies and damping were determined by performing curve fits to frequency-response magnitude and phase data. Results are given for the XV-15 with its original metal rotor blades. Frequency and damping values are also compared with predictions by two different programs, CAMRAD and ASAP.

Acree, C. W., Jr.↗