Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “micro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Temperature-Dependent Constrained Diffusion of Micro-Confined Alkylimidazolium Chloride Ionic Liquids

Alkylimidazolium chloride ionic liquids (ILs) have many uses in a variety of separation systems, including micro-confined separation systems. To understand the separation mechanism in these systems, the diffusion properties of analytes in ILs under relevant operating conditions, including micro-confinement dimension and temperature, should be known. For example, separation efficiencies for various IL-based microextraction techniques are dependent on the sample volume and temperature. Temperature-dependent (20–100 °C) fluorescence recovery after photobleaching (FRAP) was utilized to determine the diffusion properties of a zwitterionic, hydrophilic dye, ATTO 647, in alkylimidazolium chloride ILs in micro-confined geometries. These micro-confined geometries were generated by sandwiching the IL between glass substrates that were separated by ~1 to 100 μm. From the measured temperature-dependent FRAP data, we note alkyl chain length-, thickness-, and temperature-dependent diffusion coefficients, with values ranging from 0.021 to 46 μm 2 /s. Deviations from Brownian diffusion are observed at lower temperatures and increasingly less so at elevated temperatures; the differences are attributed to alterations in intermolecular interactions that reduce temperature-dependent nanoscale structural heterogeneities. Furthermore, the temperature- and thickness-dependent data provide a useful foundation for efficient design of micro-confined IL separation systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Prediction and Simulation for the Mechanical Properties of Ceramic-Based Composites Reinforced with Nano-Micro Particles

The global-local homogenization method with precise period boundary conditions is applied to predict and simulate the mechanical properties of ceramic composites reinforced by spherical nano-micro particles with enwrapping and nesting arrays. The numerical simulation is performed with different size ratios of nano-micro particles, and different configurations for representative volume element. The results show that the low radius ratios of nano-micro particles produce a larger effective Young's modulus for its more uniform dispersion, and the hexagon RVE with nesting array can make an overestimation for effective elastic modulus of ceramic composites, and the interfacial damage between nano-microscopic particles and matrix degenerates the effective elastic modulus. It shows in this paper that it is significant to improve the mechanical properties of ceramic materials by mixing some nano- and micro-particles into the matrix with good designed array methods from the viewpoints of nano-microscopic crystal structure, and a rational interfacial damage model should be further proposed to investigate the toughening mechanism of ceramic-composites reinforced with nano-micro particles.

36 MATERIALS SCIENCE↗

Spontaneous decoration of Au nanoparticles on micro-patterned reduced graphene oxide shaped by focused laser beam

We report a facile, two-step method for the micro-landscaping of Au nanoparticles(NPs) on reduced graphene oxide (rGO) film en route to micro-patterned Au(NPs)-rGO hybrid functional materials. This method employs a focused laser beam to first locally convert GO to rGO before immersing the micro-patterned GO-rGO film into HAuCl{sub 4} solution. The rGO micro-pattern, shaped by the focused laser beam, serves as nucleation sites for the reduction of Au ions. The reduction mechanism that governs the decoration of Au NPs on rGO films is akin to electroless deposition process. In this instance, surface charges that are formed during laser reduction of GO to rGO provide active nucleation sites for Au{sup 3+} ions to form Au NPs when HAuCl{sub 4} solution is introduced. The number density, the size, and size distribution of the Au NPs can thus be directly tuned and preferentially anchored onto the rGO micro-pattern by varying the incident laser power, the scanning speed of the laser, or the concentration of HAuCl{sub 4}. The resulting hybrid materials can be used as a substrate for Surface Enhanced Raman Spectroscopy (SERS). Using Rhodamine 6G as the test subject, we found an improvement of SERS enhancement over bare rGO of up to four times, depending on the size of the Au NPs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Synchrotron x-ray diffraction study of micro-patterns obtained by spatially selective hydrogenation of GaAsN

We report a comparative synchrotron radiation x-ray diffraction study of GaAs{sub 1−y}N{sub y} micro-structures obtained by two different patterning methods: spatially selective H incorporation achieved by using H-opaque masks and spatially selective H removal attained by laser writing. These methods are emerging as original routes for fabrication of micro- and nano-structures with in-plane modulation of the bandgap energy. By measuring the out-of-plane and in-plane lattice parameters, we find that for both patterning approaches the largest part of the micro-structure volume remains tensile-strained and pseudomorphic to the substrate, regardless of the compressive-strained hydrogenated barriers. However, a larger lattice disorder is probed in the laser-written micro-structures and attributed to partial removal of H and/or strain changes at the micro-structure boundaries. This larger lattice disorder is confirmed by photoluminescence studies.

36 MATERIALS SCIENCE↗

High-pressure generation using double stage micro-paired diamond anvils shaped by focused ion beam

Micron-sized diamond anvils with a 3 μm culet were successfully processed using a focused ion beam (FIB) system and the generation of high pressures was confirmed using the double stage diamond anvil cell technique. The difficulty of aligning two second-stage micro-anvils was solved via the paired micro-anvil method. Micro-manufacturing using a FIB system enables us to control anvil shape, process any materials, including nano-polycrystalline diamond and single crystal diamond, and assemble the sample exactly in a very small space between the second-stage anvils. This method is highly reproducible. High pressures over 300 GPa were achieved, and the pressure distribution around the micro-anvil culet was evaluated by using a well-focused synchrotron micro-X-ray beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Window-assisted nanosphere lithography for vacuum micro-nano-electronics

Development of vacuum micro-nano-electronics is quite important for combining the advantages of vacuum tubes and solid-state devices but limited by the prevailing fabricating techniques which are expensive, time consuming and low-throughput. In this work, window-assisted nanosphere lithography (NSL) technique was proposed and enabled the low-cost and high-efficiency fabrication of nanostructures for vacuum micro-nano-electronic devices, thus allowing potential applications in many areas. As a demonstration, we fabricated high-density field emitter arrays which can be used as cold cathodes in vacuum micro-nano-electronic devices by using the window-assisted NSL technique. The details of the fabricating process have been investigated. This work provided a new and feasible idea for fabricating nanostructure arrays for vacuum micro-nano-electronic devices, which would spawn the development of vacuum micro-nano-electronics.

36 MATERIALS SCIENCE↗

Origin of reduced efficiency in GaN-based micro-LEDs studied by scanning near-field optical microscopy

The quantum efficiency of micro-light emitting diodes (micro-LEDs) is lower than that of large area LEDs. This efficiency reduction is typically attributed to the nonradiative Shockley–Read–Hall recombination at the surface defects and current leakage through the sidewall region without a clear distinction between these effects. In this work, we attempt to find out which of these phenomena is most critical for the reduced efficiency of micro-LEDs. This has been done by mapping electroluminescence (EL) and photoluminescence (PL) and measuring PL dynamics in blue GaN micro-LEDs fabricated by dry etching. It has been found that in the as-etched device, the EL intensity is much lower than in devices with KOH etching and atomic layer deposition of SiO 2 . This effect is especially pronounced close to the sidewalls. On the other hand, PL decay times are similar in as-etched and passivated devices, both in their center and at the sidewalls. This allows concluding that the main mechanism of the reduced efficiency of micro-LEDs fabricated by dry etching is the current leakage in the sidewall region and not the nonradiative recombination. The KOH etching has been found to be the most efficient means to eliminate the current leakage.

36 MATERIALS SCIENCE↗

Micro-structuration effects on local magneto-transport in [Co/Pd]IrMn thin films

We measured the local magneto-transport (MT) signal with an out-of-plane magnetic field, including magneto-resistance (MR) and Extraordinary Hall effect (EHE), in exchange-biased [Co/Pd]IrMn thin multilayers that are micro-structured with a 100 μm window. We found that when measured locally around the window, the MT signal deviate from the expected behavior. We studied possible causes, including film micro-structuration, electrical contact geometry as well as magnetic field angular tilt. We found that tilting the magnetic field direction with respect to the normal direction does not significantly affect the MT signal, whereas the positioning and geometry of the contacts seem to highly affect the MT signal. For comparison purposes, we carried these MT measurements using the Van-der-Pauw method on a set of four microscopic contacts directly surrounding the window, and on another set of micro-contacts located outside the window, as well as a set of four contacts positioned several millimeters away of each other at the corners of the wafer. If the contacts are sufficiently far apart, the EHE and MR signals have the expected shape and are not significantly affected by the presence of the window. If, on the other hand, the contacts are micro-positioned, the shape of the EHE signal is drastically deformed, and may be modeled as a mix of the standard EHE and MR signals measured on the outer contacts. Furthermore, if the micro-contacts are located directly around the window, the deformation is amplified, and the weight of the MR signal in the mix is further increased by about 40 %. This suggests that the electron path in the Hall geometry is disturbed by both the proximity of the electrodes and by the presence of the window, which both contribute to the deformation for about two-third and one third, respectively.

36 MATERIALS SCIENCE↗

Monte Carlo N-Particle Tracking of Ultrafine Particle Flow in Bent Micro-Tubes

The problem of large pressure-differential driven laminar convective-diffusive ultrafine aerosol flow through bent micro-tubes is of interest in several contemporary research areas including; release of contents from pressurized containment vessels, aerosol sampling equipment, advanced scientific instruments, gas-phase micro-heat exchangers, and microfluidic devices. In each of these areas, the predominant problem is the determination of the fraction of particles entering the micro-tube that is deposited within the tube and the fraction that is transmitted through. Due to the extensive parameter restrictions of this class of problems, a Lagrangian particle tracking method making use of the coupling of the analytical stream line solutions of Dean and the simplified Langevin equation is quite a useful tool in problem characterization. This method is a direct analog to the Monte Carlo N-Particle method of particle transport extensively used in nuclear physics and engineering. In this work, 10 nm diameter particles with a density of 1 g/cm3 are tracked within micro-tubes with toroidal bends with pressure differentials ranging between 0.2175 and 0.87 atmospheres. The tubes have radii of 25 microns and 50 microns and the radius of curvature is between 1 m and 0.3183 cm. The carrier gas is helium, and temperatures of 298 K and 558 K are considered. Numerical convergence is considered as a function of time step size and of the number of particles per simulation. Particle transmission rates and deposition patterns within the bent micro-tubes are calculated.

Casella, Andrew M.↗

Guest editorial: Special issue micro-and nanomachines.

The articles in this special section focus on the technologies and applications supported by micro- and nanomachines. The world of artificial micro- and nanomachines has greatly expanded over the last few years to include a range of disciplines from chemistry, physics, biology, to micro/nanoengineering, robotics, and theoretical physics. The dream of engineering nanomachines involves fabricating devices that mimic the mechanical action of biological motors that operate over multiple length scales: from molecular-scale enzymes and motors such as kinesins to the micro-scale biomachinery responsible for the motility of tiny organisms such as the flagella motors of E. coli. However, the design and fabrication of artificial nano- and micromachines with comparable performance as their biological counterparts is not a straightforward task. It requires a detailed understanding of the basic principles of the operation of biomotors and mechanisms that couple the dissipation of energy to mechanical motion. Furthermore, micro engineering and microfabrication knowledge is required in order to design efficient, small and even smart micro- and nanomachines.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray

Purpose: Carbon nanotube (CNT) based field emission x-ray source technology has recently been investigated for diagnostic imaging applications because of its attractive characteristics including electronic programmability, fast switching, distributed source, and multiplexing. The purpose of this article is to demonstrate the potential of this technology for high-resolution prospective-gated cardiac micro-CT imaging. Methods: A dynamic cone-beam micro-CT scanner was constructed using a rotating gantry, a stationary mouse bed, a flat-panel detector, and a sealed CNT based microfocus x-ray source. The compact single-beam CNT x-ray source was operated at 50 KVp and 2 mA anode current with 100 {mu}mx100 {mu}m effective focal spot size. Using an intravenously administered iodinated blood-pool contrast agent, prospective cardiac and respiratory-gated micro-CT images of beating mouse hearts were obtained from ten anesthetized free-breathing mice in their natural position. Four-dimensional cardiac images were also obtained by gating the image acquisition to different phases in the cardiac cycle. Results: High-resolution CT images of beating mouse hearts were obtained at 15 ms temporal resolution and 6.2 lp/mm spatial resolution at 10% of system MTF. The images were reconstructed at 76 {mu}m isotropic voxel size. The data acquisition time for two cardiac phases was 44{+-}9 min. The CT values observed within the ventricles and the ventricle wall were 455{+-}49 and 120{+-}48 HU, respectively. The entrance dose for the acquisition of a single phase of the cardiac cycle was 0.10 Gy. Conclusions: A high-resolution dynamic micro-CT scanner was developed from a compact CNT microfocus x-ray source and its feasibility for prospective-gated cardiac micro-CT imaging of free-breathing mice under their natural position was demonstrated.

60 APPLIED LIFE SCIENCES↗

Traceable micro-CT scaling accuracy phantom for applications requiring exact measurement of distances or volumes

Purpose: Volumetric x-ray microcomputed tomography (CT) can be employed in a variety of quantitative research applications such as image-guided interventions or characterization of medical devices. To ensure the highest geometric fidelity of images for these applications, a phantom and image processing algorithm have been developed to calibrate the scaling accuracy of micro-CT scanners to a traceable standard and provide corrections to image voxel sizing. Methods: The calibration phantom contains six borosilicate beads whose separations have been measured to a traceable standard. An image processing algorithm compares the known separations of the beads to their separations in micro-CT images. A least-squares solution is used to determine linear scaling correction factors along each of the three scanner axes to minimize errors in the bead separations within the images by correcting the image voxel size. The correction factors were applied to images of a similar phantom with beads at different positions to evaluate the ability of the correction factors to reduce errors at points independent of the fiducial locations in the calibration phantom. The calibration phantom was used to evaluate the scaling accuracy of five different micro-CT scanners representing four different scanner models. Results: In two of the five scanners evaluated, the correction factors significantly reduced the mean error in bead separations in the images from 0.17% to 0.05% and from 0.37% to 0.07% of the actual bead separations, respectively. Scanners yielding similar voxel sizes possessed comparable geometric errors after correction using the phantom. Conclusions: Although the magnitude of the corrections is small, such corrections can be important for demanding micro-CT applications. Even if no voxel size correction is required, the phantom provides an easily implemented method to verify the geometric fidelity of micro-CT scanners to a traceable standard of measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

The “Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System” program is focused on developing innovative concepts for residential photovoltaic (PV) systems with the following objectives: to create an Innovative micro-inverter topology that reduces the cost from the best in class micro-inverter and provides high efficiency (>96% CEC - California Energy Commission), and 25+ year warranty, as well as reactive power support; integrate micro-inverter and PV module to reduce system price by at least $0.25/W through a) accentuating dual use of the module metal frame as a large area heat spreader reducing operating temperature, and b) eliminating redundant wiring and connectors; and create micro-inverter controller handles smart grid and safety functions to simplify implementation and reduce cost.

14 SOLAR ENERGY↗

Comparative Study of Techno-Economics of Lithium-Ion and Lead-Acid Batteries in Micro-Grids in Sub-Saharan Africa

Microgrids stand to play an important role in expanding electricity access in Sub-Saharan Africa. Batteries, which are often a core element of micro-grids, represent a substantial portion of the capital cost and are therefore an important component of developing sustainable business models for micro-grid deployment. As a result, understanding key considerations for selecting a battery type and operating it effectively are foundational for taking micro-grid growth to scale across the sub-continent. While batteries have been deployed in many systems worldwide over the past few decades, unanswered questions remain on how best to apply them to the context of off-grid micro-grids in Sub-Saharan Africa. Building on analytical work with developers in Sub-Saharan Africa and tools at NREL, this report investigates battery techno-economics and optimal operation in micro-grids, including evaluating criteria to decide between deploying lead acid or lithium-ion batteries, discussing key design considerations for the enclosures that house the batteries, and how to effectively condition the enclosure.

25 ENERGY STORAGE↗

Micro Reactor Simulation Using the PROTEUS Suite in FY19

Two micro reactor cores were simulated using the MOC solver of PROTEUS: MegaPower for a heat pipe micro reactor and Holos-Quad for a high-temperature gas-cooled micro reactor. Verification of PROTEUS standalone was performed by simulating 2D and 3D core benchmark problems developed based on MegaPower and Holos-Quad. Simulation results indicated that PROTEUS successfully modelled 2D and 3D cores of the MegaPower and Holos-Quad micro reactors and PROTEUS eigenvalues agreed well with the SERPENT Monte Carlo solutions. For a heat pipe cooled micro reactor, multiphysics simulations were performed using PROTEUS / FLUENT / ANLHTP. The coupling system of the three codes were developed using Python-based drivers, which exchange the data (power, temperature, and heat rate) required for the coupling and control the boundary conditions of FLUENT and ANLHTP. The coupled system was qualitatively verified using a 3D unit assembly problem composed of six fuel rods and seven heat pipes, which was developed based on the MegaPower compositions. The steady-state problem was solved using FLUENT / ANLHTP with given asymmetric fuel powers, demonstrating the reasonable convergence of temperatures of 7 heat pipes. Transient simulations were also performed by making one out of 7 heat pipes fail. For the transient, the coupled system of PROTEUS / FLUENT / ANLHTP demonstrated reasonable changes of total power and heat pipe temperatures with time, accounting for temperature feedback effects. In this simulation, no effect of structural change was accounted for, which will be performed using ANSYS-mechanical in future along with further verification with larger or whole-core 3D problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Key Regulatory Issues in Nuclear Micro-Reactor Transport and Siting

Inherent and passively safe nuclear micro reactors are being developed that feature mobility and autonomous operations much different than the current fleet. Numerous commercial, industrial, and military applications exist for this emerging technology. Challenges in licensing such flexible systems are foreseen, especially in areas related to siting and transport. New assessment approaches will be needed if micro reactors are to realize their full commercial potential while still preserving public safety. This report offers an initial examination of some key regulatory concerns related to micro reactor transport and siting in the continental U.S. Three deployment scenarios were developed to support a regulatory needs analysis concerning the appropriate regulatory structure for the technology, treatment of fueled and unfueled micro reactor modules during transport, and the means by which siting independence can be enhanced. With the exception of certain ultra mobile Department of Defense (DOD) applications, existing statutes suggest the Nuclear Regulatory Commission (NRC) is the appropriate regulatory agency to regulate a domestic commercial micro reactor fleet.

42 ENGINEERING↗

Pushing the Limits of Micro battery Capacity and Energy

Micro battery with higher energy density will extend the service life of the miniature sensors so that the scientists and engineers could be able to collect more data along with the time in ecological and environmental vectors, such as animal tracking. Within this project, a completely new cell design (Gen2) for micro batteries to further increase their cell capacity and energy is developed. The new cell design directly packages the active material in a hard aluminum case, decreasing the percentage of non-active components. The manufacturing process to improve wetting ability is studied and the trial run is finally given to evaluate the feasibility of the proposed technology. It’s found that both the capacity and energy with same battery size could be increased by 30% comparing with Gen1 micro battery technology previously developed by PNNL. The yield of Gen2 micro batteries is still lower due to the high degree of manual operation, especially for drilling process where more precise position control is needed. More effort is still required to improve the capability of automatic manufacturing processes. The new battery technology will support the development of smaller and lighter miniature sensors at PNNL and could potentially contribute to the large-scale manufacturing capabilities of micro batteries in US with reliable performances and long-term shelf life.

25 ENERGY STORAGE↗

Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology

Refrigerator technology has advanced significantly over the last couple of decades. Today’s refrigerators use only about 25% of the energy that was required to power models built in 1975. Even as they continually improve efficiency to meet standards, refrigerators have increased in size by almost 20%, added energy-consuming features such as through-the-door ice, and provide more benefits than ever before. However, a few challenges and technology gaps are preventing further improvement of the demand responsiveness and efficiency of the refrigerators. One of the major technology gaps in existing refrigerators is their outdated de-icing process. When the evaporator generates frost, an old-fashioned resistive heating element melts the ice. Most refrigerators have a timed defrost cycle, rather than an active system that could monitor the state of the frost. In these systems, not only is the precious electricity used at its least efficient form of conversion (direct conversion of electricity to heat), but also all the latent heat associated with the ice is wasted during the melting process. On top of that, the refrigerator needs to work harder to pull the temperature down after defrosting, and, last but not least, the food quality is severely impacted by the temperature swings during the defrost cycle. According to a study, the EU alone wastes 89 million tons of food in the supply chain every year. Any temperature swing during defrosting (about 6F according to Emerson for low-temperature cases) can negatively impact the shelf life of meat and other products for multiple days. All these issues can happen during the peak demand time of the electric grid. Unlike the conventional systems, the proposed novel advanced micro-vibrational deicing process uses no heat for defrosting. Instead, it uses the micro vibrations generated by a piezoelectric or vibration-generating module to mechanically break ice from the heat exchanger almost instantaneously. The project titled “Higher Efficiency, Demand Flexible Refrigerator with On-Demand Micro-Vibrational De-icing Technology, performed by Ultrasonic Technology Solutions, LLC (UTS) of Knoxville, TN, in collaboration with Emerson (now Copeland), represents the final phase of a multi-year effort funded under the U.S. Department of Energy’s Building Technologies Office (BTO) BENEFIT FOA 2020. Initiated on October 1, 2021, and completed after a nine-month no-cost extension ending September 30, 2025, this project aimed to develop and validate a novel micro-vibrational mechanical defrosting system, achieving more than 25% improvement in defrosting energy efficiency over conventional baseline defrosting technologies. Over sixteen quarters, the project advanced from fundamental ice-mechanical characterization and prototype development to full-scale system integration and validation. Initial efforts established project management infrastructure and characterized ice adhesion properties, followed by the design and fabrication of early aluminum-based prototypes for resonance frequency testing. Subsequent quarters saw rapid technical progression, including the identification of optimal piezoelectric and motor-based vibration mechanisms, the demonstration of effective de-icing over 6x6-inch aluminum surfaces. The team achieved its Go/No-Go milestone by exceeding the 25% energy-efficiency improvement target—reaching up to 3,340% under optimized conditions—and later confirmed that motor-driven systems offered superior performance and energy efficiency compared to piezoelectric alternatives. Continued refinement led to the development of amplifier systems on printed circuit boards, improved control and instrumentation hardware, and integration into full-scale heat exchanger (HX) prototypes at both UTS and Copeland facilities. Multiple vibration-mounting studies and frost-growth experiments guided mechanical optimization and noise-mitigation strategies, achieving a 17.5 dB reduction in sound pressure level and verifying robust mechanical performance. Advanced analyses, including modal and harmonic simulations, established a quantitative understanding of vibrational behavior and de-icing efficiency across >1000 cm² systems. The final project phase successfully demonstrated scalable integration within reach-in and chest freezer prototypes, confirmed >25% efficiency improvements in large-area systems, and completed a comprehensive business model and scale-up strategy identifying electric defrost systems as the primary beachhead market. The culmination of this DOE-supported effort establishes micro-vibrational defrosting as a viable, high-efficiency, low-noise, and demand-flexible de-icing technology, paving the way for commercial deployment and broader application in next-generation refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗